Loading...
JB201133.0141.Fireproofing Thickness.2021-04-09.Rpt.0141Dente Group A Terracon Company 30 Corporate Circle, Albany, NY 12203 Phone: 518-266-0310 Fax: 518-805-6001 FIREPROOFING THICKNESS DATA - HSS MEMBERS Project: Fowler Square Mixed Use Bldg.Client: Project No.: JB201133 Report No.: JB201133.0141.1 Date: 04/09/21 Inspected By: J Canonico Location: HSS Columns supporting 2nd Floor. Remarks: SFRM: Carboline Southwest Type 7GP. UL Y725, 1HR. Test locations for measuring thickness of fire resistive material on HSS members Location 1 2 3 4 Average Spec. K-5 8x8x3/8 0.69 0.77 0.69 0.77 0.73 0.52 1' adjacent 0.69 0.77 0.77 0.69 0.73 0.52 R-5 8x8x3/8 0.77 0.75 0.69 0.77 0.75 0.52 1' adjacent 0.77 0.77 0.77 0.77 0.77 0.52 R-6 8x8x3/8 0.77 0.75 0.63 0.77 0.73 0.52 1' adjacent 0.75 0.77 0.56 0.77 0.71 0.52 R-12 8x8x3/8 0.77 0.75 0.77 0.69 0.75 0.52 1' adjacent 0.69 0.63 0.77 0.69 0.70 0.52 R-13 8x8x3/8 0.77 0.75 0.77 0.77 0.77 0.52 1' adjacent 0.75 0.69 0.77 0.75 0.74 0.52 R-16 8x8x3/8 0.77 0.77 0.77 0.77 0.77 0.52 1' adjacent 0.77 0.77 0.75 0.77 0.77 0.52 R-17 8x8x1/2 0.64 0.64 0.64 0.64 0.64 0.39 1' adjacent 0.64 0.64 0.64 0.64 0.64 0.39 Dente Group A Terracon Company 30 Corporate Circle, Suite 201 Albany, NY 12203 Ph. 518-266-0310 Fax 518-805-6001 FIREPROOFING THICKNESS DATA - COLUMNS (FULL TIP) PROJECT: Fowler Square Mixed Use Bldg.PROJECT NO: JB201133 CLIENT:REPORT NO: JB201133.0141.2 DATE: 04/09/21 CONTRACTOR: BBL/FJ Ryan LOCATION: Columns supporting 2nd Floor. 12 NOTES: SFRM: SW Type 7GP 11 I 1 UL X771, 1HR. 10 2 9 3 8 4 7 5 6 Location 1 2 3 4 5 6 7 8 9 10 11 12 Avg.Spec. T-5 W10x33 0.50 0.75 0.81 0.88 0.88 0.69 0.44 0.75 0.63 0.63 0.50 0.75 0.68 0.63 1' adjacent 0.69 0.88 0.75 0.88 0.81 0.75 0.44 0.69 0.63 0.69 0.56 0.88 0.72 0.63 T-6 W10x33 0.63 0.88 0.81 0.88 0.56 0.63 0.63 0.63 0.69 0.63 0.50 0.88 0.70 0.63 1' adjacent 0.56 0.63 0.81 0.88 0.63 0.50 0.63 0.69 0.69 0.63 0.50 0.88 0.67 0.63 G-17 W10x33 0.56 0.88 0.88 0.88 0.88 0.63 0.88 0.63 0.88 0.69 0.56 0.63 0.75 0.63 1' adjacent 0.56 0.88 0.88 0.88 0.88 0.56 0.88 0.56 0.75 0.81 0.56 0.50 0.73 0.63 G-16 W10x33 0.63 0.81 0.88 0.88 0.81 0.63 0.50 0.81 0.88 0.88 0.50 0.81 0.75 0.63 1' adjacent 0.63 0.75 0.88 0.88 0.69 0.56 0.44 0.88 0.88 0.88 0.69 0.63 0.73 0.63 S-14 W10x33 0.56 0.81 0.81 0.69 0.69 0.81 0.56 0.81 0.69 0.88 0.56 0.81 0.72 0.63 1' adjacent 0.63 0.88 0.88 0.63 0.63 0.88 0.63 0.81 0.63 0.63 0.56 0.75 0.71 0.63 Inspected By: J Canonico Dente Group A Terracon Company 30 Corporate Circle, Albany, NY 12203 Phone: 518-266-0310 Fax: 518-805-6001 4 FIREPROOFING THICKNESS DATA - BEAMS PROJECT: Fowler Square Mixed Use Bldg.JOB NO: JB201133 CLIENT: REPORT NO: JB201133.0141.3 DATE: 04/09/21 CONTRACTOR: BBL/FJ Ryan LOCATION: Beams supporting 2nd Floor. NOTES: SFRM: Carboline Southwest Type 7GP.IUL N791, 1HR. 1 9 2 8 3 7 4 6 5 Location 1 2 3 4 5 6 7 8 9 Avg.Spec 5/R-T W21x44 0.63 0.63 0.64 0.44 0.63 0.44 0.44 0.50 0.56 0.55 0.39 1' adjacent 0.56 0.63 0.64 0.44 0.64 0.44 0.64 0.50 0.63 0.57 0.39 R/2-5 W12x14 0.78 0.50 0.78 0.44 0.78 0.78 0.56 0.78 0.78 0.69 0.53 1' adjacent 0.78 0.63 0.78 0.44 0.78 0.44 0.75 0.78 0.78 0.68 0.53 K/3-5 W12x14 0.78 0.56 0.69 0.44 0.75 0.56 0.78 0.69 0.78 0.67 0.53 1' adjacent 0.78 0.56 0.78 0.56 0.78 0.44 0.78 0.69 0.78 0.68 0.53 F/3-5 W12x14 0.78 0.78 0.78 0.50 0.78 0.38 0.78 0.63 0.78 0.69 0.53 1' adjacent 0.78 0.69 0.78 0.44 0.78 0.38 0.78 0.69 0.78 0.68 0.53 F/5-6 W24x55 0.62 0.56 0.62 0.44 0.62 0.44 0.62 0.62 0.62 0.57 0.37 1' adjacent 0.62 0.62 0.62 0.44 0.62 0.50 0.62 0.62 0.62 0.59 0.37 6/F-K W24x68 0.59 0.56 0.56 0.59 0.56 0.44 0.59 0.56 0.59 0.56 0.34 1' adjacent 0.59 0.50 0.56 0.50 0.59 0.38 0.59 0.59 0.59 0.54 0.34 INSPECTED BY: J Canonico Dente Group A Terracon Company 30 Corporate Circle, Albany, NY 12203 Phone: 518-266-0310 Fax: 518-805-6001 4 FIREPROOFING THICKNESS DATA - BEAMS PROJECT: Fowler Square Mixed Use Bldg.JOB NO: JB201133 CLIENT: REPORT NO: JB201133.0141.4 DATE: 04/09/21 CONTRACTOR: BBL/FJ Ryan LOCATION: Beams supporting 2nd Floor. NOTES: SFRM: Carboline Southwest Type 7GP.IUL N791, 1HR. 1 9 2 8 3 7 4 6 5 Location 1 2 3 4 5 6 7 8 9 Avg.Spec K/5-6 W16x31 0.67 0.50 0.67 0.44 0.67 0.44 0.67 0.67 0.67 0.60 0.42 1' adjacent 0.67 0.44 0.67 0.38 0.67 0.44 0.67 0.67 0.67 0.59 0.42 R/5-6 W12x14 0.78 0.56 0.69 0.50 0.78 0.63 0.78 0.78 0.78 0.70 0.53 1' adjacent 0.78 0.63 0.75 0.44 0.78 0.38 0.78 0.78 0.78 0.68 0.53 T/5-6 W12x19 0.71 0.56 0.71 0.38 0.71 0.38 0.71 0.71 0.71 0.62 0.46 1' adjacent 0.71 0.56 0.71 0.38 0.71 0.31 0.71 0.71 0.71 0.61 0.46 F/6-12 W21x44 0.64 0.64 0.64 0.44 0.63 0.64 0.64 0.64 0.64 0.62 0.39 1' adjacent 0.64 0.64 0.64 0.50 0.64 0.64 0.64 0.64 0.64 0.62 0.39 K/6-12 W18x35 0.67 0.67 0.67 0.44 0.67 0.44 0.67 0.67 0.67 0.62 0.42 1' adjacent 0.67 0.67 0.67 0.50 0.67 0.44 0.67 0.67 0.67 0.63 0.42 R/6-12 W16x26 0.71 0.69 0.71 0.44 0.71 0.50 0.71 0.71 0.71 0.65 0.46 1' adjacent 0.71 0.63 0.71 0.50 0.71 0.38 0.71 0.56 0.71 0.62 0.46 INSPECTED BY: J Canonico Dente Group A Terracon Company 30 Corporate Circle, Albany, NY 12203 Phone: 518-266-0310 Fax: 518-805-6001 4 FIREPROOFING THICKNESS DATA - BEAMS PROJECT: Fowler Square Mixed Use Bldg.JOB NO: JB201133 CLIENT: REPORT NO: JB201133.0141.5 DATE: 04/09/21 CONTRACTOR: BBL/FJ Ryan LOCATION: Beams supporting 2nd Floor. NOTES: SFRM: Carboline Southwest Type 7GP.IUL N791, 1HR. 1 9 N/A = Not applicable, perimeter with fire rated board/2 8 blanket. 3 7 4 6 5 Location 1 2 3 4 5 6 7 8 9 Avg.Spec 12/K-R W27x94 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.30 1' adjacent 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.30 S/12-13 W16x26 0.71 0.56 0.71 0.31 0.71 0.31 0.71 0.71 0.71 0.60 0.46 1' adjacent 0.71 0.71 0.71 0.38 0.71 0.44 0.71 0.71 0.71 0.64 0.46 R/12-13 W16x26 0.71 0.50 0.71 0.31 0.56 0.44 0.71 0.71 0.71 0.60 0.46 1' adjacent 0.71 0.63 0.71 0.31 0.63 0.44 0.71 0.71 0.71 0.62 0.46 K/12-13 W16x26 0.71 0.69 0.71 0.38 0.71 0.38 0.71 0.50 0.71 0.61 0.46 1' adjacent 0.71 0.71 0.71 0.44 0.71 0.50 0.71 0.63 0.71 0.65 0.46 F/12-13 W16x26 0.71 0.56 0.71 0.38 0.71 N/A N/A N/A N/A 0.61 0.46 1' adjacent 0.71 0.56 0.71 0.31 0.71 N/A N/A N/A N/A 0.60 0.46 13/R-S W24x68 0.59 0.59 0.59 0.56 0.59 0.44 0.59 0.56 0.59 0.57 0.34 1' adjacent 0.59 0.59 0.59 0.56 0.59 0.44 0.56 0.59 0.59 0.57 0.34 INSPECTED BY: J Canonico Dente Group A Terracon Company 30 Corporate Circle, Albany, NY 12203 Phone: 518-266-0310 Fax: 518-805-6001 4 FIREPROOFING THICKNESS DATA - BEAMS PROJECT: Fowler Square Mixed Use Bldg.JOB NO: JB201133 CLIENT: REPORT NO: JB201133.0141. DATE: 04/09/21 CONTRACTOR: BBL/FJ Ryan LOCATION: Beams supporting 2nd Floor. NOTES: SFRM: Carboline Southwest Type 7GP.IUL N791, 1HR. 1 9 2 8 3 7 4 6 5 Location 1 2 3 4 5 6 7 8 9 Avg.Spec S/13-14 W16x26 0.71 0.50 0.71 0.25 0.71 0.25 0.71 0.63 0.71 0.58 0.46 1' adjacent 0.71 0.56 0.71 0.25 0.71 0.25 0.71 0.63 0.71 0.58 0.46 R/13-14 W16x26 0.71 0.71 0.71 0.44 0.71 0.44 0.71 0.71 0.71 0.65 0.46 1' adjacent 0.71 0.71 0.71 0.50 0.71 0.44 0.71 0.71 0.71 0.66 0.46 K/13-13 W21x44 0.64 0.64 0.64 0.44 0.64 0.56 0.56 0.64 0.64 0.60 0.39 1' adjacent 0.64 0.64 0.64 0.38 0.64 0.38 0.56 0.64 0.64 0.57 0.39 F/13-15 W24x68 0.59 0.56 0.59 0.44 0.59 0.56 0.59 0.59 0.59 0.57 0.34 1' adjacent 0.59 0.59 0.59 0.44 0.59 0.56 0.59 0.59 0.59 0.57 0.34 13.8/F-K W21x44 0.64 0.64 0.64 0.38 0.64 0.38 0.56 0.64 0.64 0.57 0.39 1' adjacent 0.64 0.64 0.64 0.38 0.64 0.31 0.56 0.64 0.64 0.57 0.39 14/R-S W24x68 0.59 0.59 0.56 0.50 0.59 0.44 0.59 0.59 0.59 0.56 0.34 1' adjacent 0.59 0.59 0.56 0.59 0.59 0.50 0.59 0.59 0.59 0.58 0.34 INSPECTED BY: J Canonico Dente Group A Terracon Company 30 Corporate Circle, Albany, NY 12203 Phone: 518-266-0310 Fax: 518-805-6001 4 FIREPROOFING THICKNESS DATA - BEAMS PROJECT: Fowler Square Mixed Use Bldg.JOB NO: JB201133 CLIENT: REPORT NO: JB201133.0141.7 DATE: 04/09/21 CONTRACTOR: BBL/FJ Ryan LOCATION: Beams supporting 2nd Floor. NOTES: SFRM: Carboline Southwest Type 7GP.IUL N791, 1HR. 1 9 2 8 3 7 4 6 5 Location 1 2 3 4 5 6 7 8 9 Avg.Spec S/14-16 W12x19 0.71 0.69 0.71 0.38 0.71 0.31 0.71 0.63 0.71 0.62 0.46 1' adjacent 0.71 0.63 0.71 0.38 0.71 0.38 0.71 0.69 0.71 0.63 0.46 R/14-16 W12x14 0.78 0.78 0.78 0.38 0.79 0.31 0.79 0.75 0.78 0.68 0.53 1' adjacent 0.78 0.69 0.78 0.44 0.78 0.31 0.78 0.75 0.78 0.68 0.53 K/14x16 W12x19 0.71 0.56 0.69 0.25 0.71 0.44 0.71 0.71 0.71 0.61 0.46 1' adjacent 0.71 0.56 0.69 0.25 0.71 0.71 0.71 0.71 0.71 0.64 0.46 16/K-R W27x84 0.57 0.57 0.57 0.50 0.57 0.50 0.57 0.57 0.57 0.55 0.32 1' adjacent 0.57 0.57 0.57 0.50 0.57 0.50 0.57 0.57 0.57 0.55 0.32 S/16-17 W16x31 0.67 0.67 0.67 0.56 0.67 0.44 0.67 0.63 0.67 0.63 0.42 1' adjacent 0.67 0.67 0.67 0.44 0.67 0.44 0.67 0.67 0.67 0.62 0.42 R/16-17 W16x26 0.69 0.69 0.69 0.31 0.71 0.31 0.63 0.69 0.71 0.60 0.46 1' adjacent 0.71 0.56 0.71 0.50 0.71 0.44 0.63 0.56 0.71 0.61 0.46 INSPECTED BY: J Canonico Dente Group A Terracon Company 30 Corporate Circle, Albany, NY 12203 Phone: 518-266-0310 Fax: 518-805-6001 4 FIREPROOFING THICKNESS DATA - BEAMS PROJECT: Fowler Square Mixed Use Bldg.JOB NO: JB201133 CLIENT: REPORT NO: JB201133.0141.8 DATE: 04/09/21 CONTRACTOR: BBL/FJ Ryan LOCATION: Beams supporting 2nd Floor. NOTES: SFRM: Carboline Southwest Type 7GP.IUL N791, 1HR. 1 9 2 8 3 7 4 6 5 Location 1 2 3 4 5 6 7 8 9 Avg.Spec K/16-17 W16x26 0.71 0.56 0.56 0.31 0.56 0.38 0.69 0.69 0.71 0.57 0.46 1' adjacent 0.71 0.56 0.50 0.31 0.69 0.38 0.50 0.50 0.71 0.54 0.46 17/K-G W24x68 0.59 0.59 0.59 0.50 0.59 0.56 0.59 0.59 0.59 0.58 0.34 1' adjacent 0.59 0.59 0.59 0.50 0.59 0.44 0.59 0.59 0.59 0.56 0.34 G/16-17 W16x26 0.71 0.63 0.69 0.31 0.71 0.38 0.63 0.71 0.71 0.61 0.46 1' adjacent 0.71 0.63 0.71 0.31 0.71 0.56 0.69 0.71 0.71 0.64 0.46 G/17-18 W16x26 0.71 0.69 0.69 0.31 0.71 0.31 0.71 0.71 0.71 0.62 0.46 1' adjacent 0.71 0.71 71.00 0.50 0.71 0.31 0.71 0.71 0.71 8.45 0.46 K/17-18 W16x26 0.71 0.71 0.63 0.44 0.69 0.50 0.71 0.71 0.71 0.65 0.46 1' adjacent 0.71 0.71 0.69 0.50 0.71 0.44 0.71 0.71 0.71 0.65 0.46 R/17-18 W16x26 0.71 0.71 0.71 0.38 0.63 0.31 0.69 0.69 0.71 0.62 0.46 1' adjacent 0.71 0.71 0.71 0.44 0.71 0.38 0.71 0.63 0.71 0.63 0.46 INSPECTED BY: J Canonico Dente Group A Terracon Company 30 Corporate Circle, Albany, NY 12203 Phone: 518-266-0310 Fax: 518-805-6001 4 FIREPROOFING THICKNESS DATA - BEAMS PROJECT: Fowler Square Mixed Use Bldg.JOB NO: JB201133 CLIENT: REPORT NO: JB201133.0141.9 DATE: 04/09/21 CONTRACTOR: BBL/FJ Ryan LOCATION: Beams supporting 2nd Floor. NOTES: SFRM: Carboline Southwest Type 7GP.IUL N791, 1HR. 1 9 2 8 3 7 4 6 5 Location 1 2 3 4 5 6 7 8 9 Avg.Spec S/17-18 W16x26 0.71 0.69 0.71 0.38 0.71 0.38 0.71 0.71 0.71 0.63 0.46 1' adjacent 0.71 0.56 0.71 0.38 0.71 0.31 0.71 0.71 0.71 0.61 0.46 K.5/17-18 W21X50 0.62 0.62 0.62 0.31 0.62 0.44 0.62 0.62 0.62 0.57 0.37 1' adjacent 0.62 0.62 0.62 0.38 0.62 0.38 0.62 0.62 0.62 0.57 0.37 K.5/16-17 W21x50 0.62 0.62 0.62 0.50 0.62 0.31 0.50 0.50 0.62 0.55 0.37 1' adjacent 0.62 0.62 0.62 0.44 0.62 0.38 0.56 0.50 0.62 0.55 0.37 K.5/14-16 W16x26 0.71 0.69 0.71 0.44 0.71 0.38 0.71 0.63 0.71 0.63 0.46 1' adjacent 0.71 0.71 0.71 0.50 0.71 0.56 0.69 0.56 0.71 0.65 0.46 K.5/13-14 W21x50 0.62 0.62 0.62 0.50 0.62 0.56 0.62 0.62 0.62 0.60 0.37 1' adjacent 0.62 0.62 0.62 0.44 0.62 0.50 0.62 0.62 0.62 0.59 0.37 INSPECTED BY: J Canonico