Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
fowler_square_mixed_use_bldg-submittal#016-rev-0-fire_stopping-202104192122
BBL Construction Services, LLC 302 Washington Ave Extension Albany, New York 12203 Phone: (518) 452-8200 Project: 201039 - FOWLER SQUARE MIXED USE BLDG 719 BAY ROAD QUEENSBURY, New York 12804 Distribution Summary Distributed on 04/19/2021 by Ryan Etue (BBL Construction Services, LLC) To:Eric Weatherwax (BBL Construction Services, LLC), Adam Rosen (AE Rosen Electric) , Bobby Chatterton (BBL Construction Services, LLC) Message:Adam, Please see the attached submittal, Fire Stopping, marked Approved and submitted For Record Only. Thank You, Ryan Etue Additional Attachments: NAME RESPONSE ATTACHMENTS COMMENT Eric Weatherwax (BBL Construction Services, LLC) For Record Only 16050-016.0 - Electrical FireStopping Mediawebserver - For Approval.pdf The attached submittal is uploaded and submitted For Record Only. Fire Stopping REVISION: 0 SUBMITTAL MANAGER:Ryan Etue (BBL Construction Services, LLC) STATUS: Closed DATE CREATED: 04/15/2021 ISSUE DATE: SPEC SECTION: 16050 - Electrical RESPONSIBLE CONTRACTOR: AE Rosen Electric RECEIVED FROM:Adam Rosen RECEIVED DATE: SUBMIT BY: FINAL DUE DATE:04/21/2021 LOCATION: SUB JOB:COST CODE: TYPE: Product Data APPROVERS:Eric Weatherwax (BBL Construction Services, LLC) Building #: BALL IN COURT: DISTRIBUTION: Eric Weatherwax (BBL Construction Services, LLC), Bobby Chatterton (BBL Construction Services, LLC) DESCRIPTION: SUBMITTAL WORKFLOW NAME SENT DATE DUE DATE RETURNED DATE RESPONSE ATTACHMENTS COMMENTS Adam Rosen 04/15/2021 04/15/2021 04/19/2021 Submitted 16050-016.0 - Electrical FireStopping Mediawebserver - For Approval.pdf Eric Weatherwax 04/19/2021 04/21/2021 04/19/2021 For Record Only 16050-016.0 - Electrical FireStopping Mediawebserver - For Approval.pdf (Current) The attached submittal is uploaded and submitted For Record Only. BY DATE COPIES TO BBL Construction Services, LLC Page 1 of 1 Printed On: 04/19/2021 05:22 PM Submittal #016.0 16050 - Electrical 3M™ Fire Barrier Sealant CP 25WB+ Product Data Sheet 1. Product Description 3M™ Fire Barrier Sealant CP 25WB+ is a high-performance, ready-to-use, gun-grade, latex-based, intumescent sealant that dries to form a monolithic firestop seal that also acts as a barrier to airborne sound transmission. 3M™ Fire Barrier Sealant CP 25WB+ helps control the spread of fire, smoke and noxious gasses before, during and after exposure to a fire when installed in accordance with a listed through penetration or fire-resistive joint assembly system. 3M™ Fire Barrier Sealant CP 25WB+ firestops blank openings and penetrations passing through fire-rated floor, floor/ceiling or wall assemblies and other fire-rated interior building construction. The unique intumescent property of this material allows 3M™ Fire Barrier Sealant CP 25WB+ to expand and help maintain a firestop penetration seal for up to 4 hours as penetrants are exposed to fire. 3M™ Fire Barrier Sealant CP 25WB+ exhibits excellent adhesion to a full range of construction substrates and penetrants. No mixing is required. 2. Applications High-performance 3M™ Fire Barrier Sealant CP 25WB+ is ideal for sealing single or multiple through penetrations in fire-rated construction. 3M™ Fire Barrier Sealant CP 25WB+ is typically used in mechanical, electrical and plumbing applications to firestop openings created by the following penetrations in fire-rated floors, floor/ceilings or walls: metallic pipe, plastic pipe (excluding CPVC), conduit, power and communication cable, cable trays, busways, combos, insulated pipe and HVAC duct penetrations 3M™ Fire Barrier Sealant CP 25WB+ is also used to firestop blank openings and static construction joints. For technical support relating to 3M™ Fire Protection Products and Systems, call: 1-800-328-1687 For more information on 3M™ Fire Protection Products, visit: www.3M.com/firestop 3. Specifications 3M™ Fire Barrier Sealant CP 25WB+ shall be a one component, ready-to-use, gun-grade, latex-based, intumescent firestop sealant capable of expanding a minimum of three times its dried volume when exposed to temperatures above 1000°F (538°C). The material shall be thixotropic and shall be applicable to overhead, vertical and horizontal firestops. The sealant shall be listed by independent test agencies such as UL, Intertek or FM. 3M™ Fire Barrier Sealant CP 25WB+ shall be tested to and pass the criteria of ASTM E 814 (UL 1479) Standard Test Method for Fire Tests of Penetration Firestop Systems, ASTM E 1966 (UL 2079) Standard Test Method for Fire Resistive Joint Systems and CAN/ULC S115 Standard Method of Fire Tests of Firestop Systems. 3M™ Fire Barrier Sealant CP 25WB+ meets the requirements of the IBC, IRC, IFC, IPC, IMC, NFPA 5000, NEC (NFPA 70) and NFPA 101. Typically Specified Division Division 7 Section 07 84 00 – Firestopping Related Sections Section 07 84 16 – Annular Space Protection Section 07 84 43 – Fire-Resistant Joint Sealants Section 07 86 00 – Smoke Seals Section 07 87 00 – Smoke Containment Barriers Section 07 27 00 – Air Barriers Section 21 00 00 – Fire Suppression Section 22 00 00 – Plumbing Section 26 00 00 – Electrical High-performance firestop sealant that also helps minimize sound transfer Product Color: Red Product Features • Firestop tested up to 4 hours in accordance with ASTM E 814 (UL 1479) & CAN/ULC S115 • Fire Resistance tested for static construction joint systems in accordance with ASTM E 1966 (UL 2079) • Re-enterable / repairable • Meets UL 1479 aging requirements • Helps minimize sound transfer* • Applied with conventional caulking equipment (excellent caulk rate) • Extensive listed systems • Sag-resistant • Halogen-free • Excellent adhesion • Paintable • Water clean up * Minimizes noise transfer — STC-Rating of 54 when tested in STC 54-rated wall assembly. Meets the intent of LEED® VOC regulations — helps reduce the quantity of indoor air contaminants that may be odorous, irritating and harmful to the comfort and well-being of the installers and occupants. <250 g/L VOC contents (less H2O and exempt solvents). 7. Maintenance No maintenance should be required when installed in accordance with the applicable UL, Intertek, FM or other third-party listed system. Once installed, if any section of the 3M™ Fire Barrier Sealant CP 25WB+ is damaged, the following procedure will apply: remove and reinstall the damaged section in accordance with the applicable listed system, with a minimum 1/2 in. (12.7mm) overlap onto the adjacent material. 3M Industrial Adhesives and Tapes Division 3M Center, Building 225-3S-06 St. Paul, MN 55144-1000 USA 1-800-362-3550 www.3M.com/IATD Color:Red Application Temperature Range (ASTM C 1299):40° to 122°F (4° to 50°C) Service Temperature Range:-20° to 180°F (-28° to 82°C) STC (ASTM E 90 and ASTM E 413):54 when tested in STC 54-rated wall assembly Surface Burning (ASTM E 84): Flame Spread 0, Smoke Development 0 Hardness (ASTM D 2240 Shore A):45 Tensile Strength:85 psi (0.59 MPa) Volume Shrinkage (ASTM C 1241):28% VOC Less H2O and Exempt Solvents:< 1g/L Dry: Under typical conditions of 75°F (23°C) and 50% relative humidity, sealant becomes tack-free in about ten minutes and dry-to-touch in 30–60 minutes. Full dry depends upon ambient conditions and volume of sealant. Typical dry rate is approximately 1/8-inch (3mm) per day. 4. Physical Properties Unit Volume: 10.1 fl. oz. tube (298.7mL, 18.2 in.3), 20 fl. oz. sausage (591.5mL, 36.1 in.3), 27 fl. oz tube (798.5mL, 48.7 in.3), 2 gallon pail (7.57L, 462 in.3), 5 gallon pail (18.9L, 1155 in.3) 5. Packaging, Storage, Shelf Life Packaging: Product packaged in cartridge or pail is enclosed in HDPE plastic containers, sausage is packaged in aluminum foil wrap. Storage: 3M™ Fire Barrier Sealant CP 25WB+ should be stored indoors in dry conditions between 40°F and 90°F (4°C and 32°C) in the original unopened package. Avoid repeated freeze / thaw exposures of the 3M™ Fire Barrier Sealant CP 25WB+ prior to installation. Shelf Life: 3M™ Fire Barrier Sealant CP 25WB+ shelf life is 12 months in original unopened containers from date of packaging when stored above 68°F (20°C). Lot numbering (e.g. 8183AS): First digit = Last digit of year manufactured, Second to fourth digit = Julian Date, Letters = Random to distinguish between lot numbers 9. Safe Handling Information Consult product Material Safety Data Sheet (MSDS) prior to handling and disposal. 8. Availability 3M™ Fire Barrier Sealant CP 25WB+ is available from 3M Authorized Fire Protection Products Distributors and Dealers. 3M™ Fire Barrier Sealant CP 25WB+ is available in 10.1 fl. oz. cartridges (12/case), 20.0 fl. oz. sausages (10/case), 27.0 fl. oz. cartridges (6/case), 2 gallon pails (1/case) and 5 gallon pails (1/case). For additional technical and purchasing information regarding this and other 3M™ Fire Protection Products, please call: 1-800-328-1687 or visit www.3M.com/firestop. 6. Installation Techniques Preparatory Work: The surface of the opening and any penetrating items should be cleaned to allow for the proper adhesion of the 3M™ Fire Barrier Sealant CP 25WB+. Ensure that the surface of the substrates are not wet and are frost free. Sealant can be installed with a standard caulking gun, pneumatic pumping equipment or it can be easily applied with a putty knife or trowel. Installation Details: Install the applicable depth of backing material, if required, as detailed within the applicable UL, Intertek, FM or other third-party listed system. Cut the end of the 3M™ Fire Barrier Sealant CP 25WB+ tube spout to achieve the desired bead width when applying. Install the applicable depth of 3M™ Fire Barrier Sealant CP 25WB+ into the opening flush with the surface of the substrate, or as detailed within the applicable listed system, at the depth for the assembly and rating that is required. Tool within five minutes. Clean all tools immediately after use with water. Limitations: Do not apply 3M™ Fire Barrier Sealant CP 25WB+ when surrounding temperature is less than 40°F (4°C) and in conditions where seals may be exposed to rain or water spray within 18 hours of application. Do not apply 3M™ Fire Barrier Sealant CP 25WB+ to building materials that bleed oil, plasticizers or solvent (e.g. impregnated wood, oil-based sealants, or green or partially vulcanized rubber). Do not apply 3M™ Fire Barrier Sealant CP 25WB+ to wet or frost-coated surfaces or to areas that are continuously damp or immersed in water. NOTICE: This product is not acceptable for use with chlorinated polyvinylchloride (CPVC) pipes. Consult a 3M Authorized Fire Protection Products Distributor / Dealer or Sales Representative for Applicable UL, Intertek or other third-party drawings and system details. Important Notice to User: Technical Information: The technical information, recommendations and other statements contained in this document are based upon tests or experience that 3M believes are reliable, but the accuracy or completeness of such information is not guaranteed. Product Use: Many factors beyond 3M’s control and uniquely within user’s knowledge and control can affect the use and performance of a 3M product in a particular application. Given the variety of factors that can affect the use and performance of a 3M product, user is solely responsible for evaluating the 3M product and determining whether it is fit for a particular purpose and suitable for user’s method of application. Warranty and Limited Remedy: 3M warrants that each 3M Fire Protection Product will be free from defects in material and manufacture for 90 days from the date of purchase from 3M’s authorized distributor. 3M MAKES NO OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If a 3M product does not conform to this warranty, the sole and exclusive remedy is, at 3M’s option, replacement of the 3M product or refund of the purchase price. Limitation of Liability: Except where prohibited by law, 3M will not be liable for any loss or damage arising from the 3M product, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted. Please Recycle. Printed in U.S.A. © 3M 2016. All rights reserved. Literature Order Info: 98-0400-5012-6 3M is a trademark of 3M Company. All other trademarks are the property of their respective owners. June 2015 Installation Guide 3M™ Fire Barrier Sealant CP 25WB+ 1 Cartridge: Cut off tip of nozzle to desired size. Sausage Pack: Cut off tip of nozzle to desired size, cut and remove foil crimp on one end of sausage pack. Pail: Remove lid. 3 When applicable, install mineral wool to required depth per system specifications. 2 Cartridge: Insert cartridge into cartridge applicator. Sausage Pack: Insert sausage pack into sausage pack applicator, place nozzle on end of applicator tube, secure with screw-on collar. Pail: Install proper follower plate and use with bulk loading applicator, or trowel directly from pail. 4 Apply sealant to required depth in annular space per system specifications. Completely fill annular space with sealant. 5 Tool sealant to be flush with substrate. For technical support relating to 3M™ Fire Protection Products and Systems, call: 1-800-328-1687 For more information on 3M™ Fire Protection Products, visit: www.3M.com/firestop Installation Guide This installation guide highlights requirements for 3M™ Fire Barrier Sealant CP 25WB+ for firestopping general through-penetration and construction joint applications (excluding CPVC). This guide is intended only to highlight general steps or methods and is not intended to describe all details and requirements. System specifications should comply with local and federal regulations. Examples of system specifiers include UL, Intertek, and European Technical Approvals and Assessments. Installer should confirm that the field conditions (such as opening size, pipe size and material, insulation type and thickness, and annular space) comply with the system specifications. Repair Procedure in Case of Damage Damaged seals shall be removed and replaced. Precautionary Information Refer to product label and Safety Data Sheet for health and safety information before using the product. For information please contact your local 3M Office. www.3M.com/SDS 3M Industrial Adhesives and Tapes Division 3M Center, Building 225-3S-06 St. Paul, MN 55144-1000 1-800-328-1687 www.3M.com/firestop 3M is a trademark of 3M Company. © 3M 2015. All rights reserved. Important Notice to User: Technical Information: The technical information, recommendations and other statements contained in this document are based upon tests or experience that 3M believes are reliable, but the accuracy or completeness of such information is not guaranteed. Product Use: Many factors beyond 3M’s control and uniquely within user’s knowledge and control can affect the use and performance of a 3M product in a particular application. Given the variety of factors that can affect the use and performance of a 3M product, user is solely responsible for evaluating the 3M product and determining whether it is fit for a particular purpose and suitable for user’s method of application. Warranty and Limited Remedy: 3M warrants that each 3M Fire Protection Product will be free from defects in material and manufacture for 90 days from the date of purchase from 3M’s authorized distributor. 3M MAKES NO OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If a 3M product does not conform to this warranty, the sole and exclusive remedy is, at 3M’s option, replacement of the 3M product or refund of the purchase price. Limitation of Liability: Except where prohibited by law, 3M will not be liable for any loss or damage arising from the 3M product, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted. 3M Brand Fire Barrier CP-25WB+ 02/25/21 __________________________________________________________________________________________ Page 1 of 12 Safety Data Sheet Copyright,2021, 3M Company. All rights reserved. Copying and/or downloading of this information for the purpose of properly utilizing 3M products is allowed provided that: (1) the information is copied in full with no changes unless prior written agreement is obtained from 3M, and (2) neither the copy nor the original is resold or otherwise distributed with the intention of earning a profit thereon. Document Group:09-5451-1 Version Number:26.08 Issue Date:02/25/21 Supercedes Date:03/20/20 SECTION 1: Identification 1.1. Product identifier 3M Brand Fire Barrier CP-25WB+ Product Identification Numbers ID Number UPC ID Number UPC 42-0016-4710-8 42-0016-4715-7 42-0016-4716-5 98-0400-5380-7 00-51115-11639-1 98-0400-5381-5 00-51115-11640-7 98-0400-5382-3 00-51115-11641-4 98-0400-5383-1 00-51115-11642-1 98-0400-5406-0 00-51115-16515-3 98-0400-5456-5 98-0400-5562-0 000-51115-11642-1 98-0400-5573-7 000-51115-16515-3 98-0400-5610-7 98-0400-5629-7 7100006311, 7000006379, 7000059394, 7000145569, 7100025518, 7000006383, 7010353050, 7100137423 1.2. Recommended use and restrictions on use Recommended use Fire Protection, Industrial use 1.3. Supplier’s details MANUFACTURER:3M DIVISION:Industrial Adhesives and Tapes Division ADDRESS:3M Center, St. Paul, MN 55144-1000, USA Telephone:1-888-3M HELPS (1-888-364-3577) 1.4. Emergency telephone number 1-800-364-3577 or (651) 737-6501 (24 hours) SECTION 2: Hazard identification 2.1. Hazard classification Serious Eye Damage/Irritation: Category 2A. Reproductive Toxicity: Category 2. 2.2. Label elements Signal word Warning 3M Brand Fire Barrier CP-25WB+ 02/25/21 __________________________________________________________________________________________ Page 2 of 12 Symbols Exclamation mark | Health Hazard | Pictograms Hazard Statements Causes serious eye irritation. Suspected of damaging fertility or the unborn child. Precautionary Statements General: Keep out of reach of children. Prevention: Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Wear protective gloves and eye/face protection. Wash thoroughly after handling. Response: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention. IF exposed or concerned: Get medical advice/attention. Storage: Store locked up. Disposal: Dispose of contents/container in accordance with applicable local/regional/national/international regulations. SECTION 3: Composition/information on ingredients Ingredient C.A.S. No.% by Wt Water 7732-18-5 10 - 30 Trade Secret * Zinc Borate 2335 138265-88-0 10 - 30 Trade Secret * Polymer (NJTS Reg. No. 04499600-7270)Trade Secret* 10 - 30 Trade Secret * Sodium Silicate 1344-09-8 10 - 19 Trade Secret * Ethylhexyldiphenyl Phosphate 1241-94-7 3 - 7 Trade Secret * Iron Oxide 1309-37-1 1 - 5 Trade Secret * Oxide glass chemicals 65997-17-3 1 - 5 Trade Secret * Polyethylene Glycol 25322-68-3 1 - 5 Trade Secret * Di-2-ethylhexlphenyl Phosphate 16368-97-1 < 1 Trade Secret * Quartz Silica 14808-60-7 < 1 Trade Secret * Triphenyl Phosphate 115-86-6 < 1 Trade Secret * NJTS or NJTSRN: New Jersey Trade Secret Registry Number. 3M Brand Fire Barrier CP-25WB+ 02/25/21 __________________________________________________________________________________________ Page 3 of 12 *The specific chemical identity and/or exact percentage (concentration) of this composition has been withheld as a trade secret. SECTION 4: First aid measures 4.1. Description of first aid measures Inhalation: Remove person to fresh air. If you feel unwell, get medical attention. Skin Contact: Wash with soap and water. If signs/symptoms develop, get medical attention. Eye Contact: Immediately flush with large amounts of water. Remove contact lenses if easy to do. Continue rinsing. Get medical attention. If Swallowed: Rinse mouth. If you feel unwell, get medical attention. 4.2. Most important symptoms and effects, both acute and delayed No critical symptoms or effects. See Section 11.1, information on toxicological effects. 4.3. Indication of any immediate medical attention and special treatment required Not applicable SECTION 5: Fire-fighting measures 5.1. Suitable extinguishing media Non-combustible. Use a fire fighting agent suitable for surrounding fire. 5.2. Special hazards arising from the substance or mixture None inherent in this product. Hazardous Decomposition or By-Products Substance Condition Carbon monoxide During Combustion Carbon dioxide During Combustion Oxides of Phosphorus During Combustion 5.3. Special protective actions for fire-fighters Wear full protective clothing, including helmet, self-contained, positive pressure or pressure demand breathing apparatus, bunker coat and pants, bands around arms, waist and legs, face mask, and protective covering for exposed areas of the head. SECTION 6: Accidental release measures 6.1. Personal precautions, protective equipment and emergency procedures Evacuate area. Ventilate the area with fresh air. Refer to other sections of this SDS for information regarding physical and health hazards, respiratory protection, ventilation, and personal protective equipment. 6.2. Environmental precautions Avoid release to the environment. 6.3. Methods and material for containment and cleaning up Collect as much of the spilled material as possible. Place in a closed container approved for transportation by appropriate authorities. Clean up residue. Seal the container. Dispose of collected material as soon as possible in accordance with applicable local/regional/national/international regulations. 3M Brand Fire Barrier CP-25WB+ 02/25/21 __________________________________________________________________________________________ Page 4 of 12 SECTION 7: Handling and storage 7.1. Precautions for safe handling Keep out of reach of children. Do not handle until all safety precautions have been read and understood. Avoid breathing dust/fume/gas/mist/vapors/spray. Do not get in eyes, on skin, or on clothing. Do not eat, drink or smoke when using this product. Wash thoroughly after handling. Avoid release to the environment. Use personal protective equipment (gloves, respirators, etc.) as required. 7.2. Conditions for safe storage including any incompatibilities Keep cool. Store away from heat. Store away from areas where product may come into contact with food or pharmaceuticals. Store in a dry place. SECTION 8: Exposure controls/personal protection 8.1. Control parameters Occupational exposure limits If a component is disclosed in section 3 but does not appear in the table below, an occupational exposure limit is not available for the component. Ingredient C.A.S. No.Agency Limit type Additional Comments Triphenyl Phosphate 115-86-6 ACGIH TWA:3 mg/m3 A4: Not class. as human carcin Triphenyl Phosphate 115-86-6 OSHA TWA:3 mg/m3 Iron Oxide 1309-37-1 ACGIH TWA(respirable fraction):5 mg/m3 A4: Not class. as human carcin Iron Oxide 1309-37-1 OSHA TWA(as fume):10 mg/m3 Quartz Silica 14808-60-7 ACGIH TWA(respirable fraction):0.025 mg/m3 A2: Suspected human carcin. Quartz Silica 14808-60-7 OSHA TWA Table Z- 1(respirable):0.05 mg/m3;TWA Table Z- 3(respirable):0.1 mg/m3 Polyethylene Glycol 25322-68-3 AIHA TWA(as aerosol):10 mg/m3 Oxide glass chemicals 65997-17-3 Manufacturer determined TWA(as non-fibrous, respirable)(8 hours):3 mg/m3;TWA(as non-fibrous, inhalable fraction)(8 hours):10 mg/m3 ACGIH : American Conference of Governmental Industrial Hygienists AIHA : American Industrial Hygiene Association CMRG : Chemical Manufacturer's Recommended Guidelines OSHA : United States Department of Labor - Occupational Safety and Health Administration TWA: Time-Weighted-Average STEL: Short Term Exposure Limit CEIL: Ceiling 8.2. Exposure controls 8.2.1. Engineering controls Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure Limits and/or control dust/fume/gas/mist/vapors/spray. If ventilation is not adequate, use respiratory protection equipment. 8.2.2. Personal protective equipment (PPE) 3M Brand Fire Barrier CP-25WB+ 02/25/21 __________________________________________________________________________________________ Page 5 of 12 Eye/face protection Select and use eye/face protection to prevent contact based on the results of an exposure assessment. The following eye/face protection(s) are recommended: Indirect Vented Goggles Skin/hand protection Select and use gloves and/or protective clothing approved to relevant local standards to prevent skin contact based on the results of an exposure assessment. Selection should be based on use factors such as exposure levels, concentration of the substance or mixture, frequency and duration, physical challenges such as temperature extremes, and other use conditions. Consult with your glove and/or protective clothing manufacturer for selection of appropriate compatible gloves/protective clothing. Gloves made from the following material(s) are recommended: Butyl Rubber Neoprene Nitrile Rubber Respiratory protection An exposure assessment may be needed to decide if a respirator is required. If a respirator is needed, use respirators as part of a full respiratory protection program. Based on the results of the exposure assessment, select from the following respirator type(s) to reduce inhalation exposure: Half facepiece or full facepiece air-purifying respirator suitable for organic vapors and particulates For questions about suitability for a specific application, consult with your respirator manufacturer. SECTION 9: Physical and chemical properties 9.1. Information on basic physical and chemical properties Appearance Physical state Color Solid Red Specific Physical Form: Paste Odor Odorless Odor threshold No Data Available pH 7.5 - 8 Melting point No Data Available Boiling Point 100 ºC Flash Point No flash point Evaporation rate 0.33 [Ref Std:BUOAC=1] Flammability (solid, gas)Not Classified Flammable Limits(LEL)Not Applicable Flammable Limits(UEL)Not Applicable Vapor Pressure 17.5 mmHg [@ 20 ºC] Vapor Density No Data Available Density No Data Available Specific Gravity 1.35 [Ref Std:WATER=1] Solubility in Water Complete Solubility- non-water No Data Available Partition coefficient: n-octanol/ water No Data Available Autoignition temperature Not Applicable Decomposition temperature No Data Available Viscosity No Data Available Molecular weight No Data Available Volatile Organic Compounds <=0.5 % weight [Test Method:tested per EPA method 24] 3M Brand Fire Barrier CP-25WB+ 02/25/21 __________________________________________________________________________________________ Page 6 of 12 VOC Less H2O & Exempt Solvents <=6 g/l [Test Method:tested per EPA method 24] SECTION 10: Stability and reactivity 10.1. Reactivity This material is considered to be non reactive under normal use conditions. 10.2. Chemical stability Stable. 10.3. Possibility of hazardous reactions Hazardous polymerization will not occur. 10.4. Conditions to avoid None known. 10.5. Incompatible materials None known. 10.6. Hazardous decomposition products Substance Condition None known. Refer to section 5.2 for hazardous decomposition products during combustion. SECTION 11: Toxicological information The information below may not be consistent with the material classification in Section 2 if specific ingredient classifications are mandated by a competent authority. In addition, toxicological data on ingredients may not be reflected in the material classification and/or the signs and symptoms of exposure, because an ingredient may be present below the threshold for labeling, an ingredient may not be available for exposure, or the data may not be relevant to the material as a whole. 11.1. Information on Toxicological effects Signs and Symptoms of Exposure Based on test data and/or information on the components, this material may produce the following health effects: Inhalation: Respiratory Tract Irritation: Signs/symptoms may include cough, sneezing, nasal discharge, headache, hoarseness, and nose and throat pain. Skin Contact: Mild Skin Irritation: Signs/symptoms may include localized redness, swelling, itching, and dryness. Eye Contact: Severe Eye Irritation: Signs/symptoms may include significant redness, swelling, pain, tearing, cloudy appearance of the cornea, and impaired vision. Ingestion: May be harmful if swallowed. Gastrointestinal Irritation: Signs/symptoms may include abdominal pain, stomach upset, nausea, vomiting and diarrhea. 3M Brand Fire Barrier CP-25WB+ 02/25/21 __________________________________________________________________________________________ Page 7 of 12 May cause additional health effects (see below). Additional Health Effects: Reproductive/Developmental Toxicity: Contains a chemical or chemicals which can cause birth defects or other reproductive harm. Carcinogenicity: Ingredient CAS No.Class Description Regulation SILICA, CRYS AIRRESP 14808-60-7 Known human carcinogen National Toxicology Program Carcinogens Quartz Silica 14808-60-7 Grp. 1: Carcinogenic to humans International Agency for Research on Cancer Toxicological Data If a component is disclosed in section 3 but does not appear in a table below, either no data are available for that endpoint or the data are not sufficient for classification. Acute Toxicity Name Route Species Value Overall product Dermal No data available; calculated ATE >5,000 mg/kg Overall product Ingestion No data available; calculated ATE2,000 - 5,000 mg/kg Zinc Borate 2335 Dermal Rabbit LD50 > 10,000 mg/kg Zinc Borate 2335 Inhalation- Dust/Mist Rat LC50 > 4.95 mg/l Zinc Borate 2335 Ingestion Rat LD50 > 10,000 mg/kg Polymer (NJTS Reg. No. 04499600-7270)Dermal LD50 estimated to be > 5,000 mg/kg Polymer (NJTS Reg. No. 04499600-7270)Ingestion Rat LD50 > 2,000 mg/kg Sodium Silicate Dermal Rabbit LD50 > 4,640 mg/kg Sodium Silicate Ingestion Rat LD50 500 mg/kg Ethylhexyldiphenyl Phosphate Dermal Rabbit LD50 > 7,940 mg/kg Ethylhexyldiphenyl Phosphate Ingestion Rat LD50 > 24,000 mg/kg Iron Oxide Dermal Not available LD50 3,100 mg/kg Iron Oxide Ingestion Not available LD50 3,700 mg/kg Polyethylene Glycol Dermal Rabbit LD50 > 20,000 mg/kg Polyethylene Glycol Ingestion Rat LD50 32,770 mg/kg Oxide glass chemicals Dermal LD50 estimated to be > 5,000 mg/kg Oxide glass chemicals Ingestion LD50 estimated to be 2,000 - 5,000 mg/kg Triphenyl Phosphate Dermal Rabbit LD50 > 7,900 mg/kg Triphenyl Phosphate Inhalation- Dust/Mist (4 hours) Rat LC50 > 50 mg/l Triphenyl Phosphate Ingestion Rat LD50 > 3,000 mg/kg Quartz Silica Dermal LD50 estimated to be > 5,000 mg/kg Quartz Silica Ingestion LD50 estimated to be > 5,000 mg/kg ATE = acute toxicity estimate Skin Corrosion/Irritation Name Species Value Zinc Borate 2335 Rabbit No significant irritation Polymer (NJTS Reg. No. 04499600-7270)Rabbit Minimal irritation Sodium Silicate Rabbit Corrosive Iron Oxide Rabbit No significant irritation Polyethylene Glycol Rabbit Minimal irritation Oxide glass chemicals Professio nal judgeme nt No significant irritation 3M Brand Fire Barrier CP-25WB+ 02/25/21 __________________________________________________________________________________________ Page 8 of 12 Quartz Silica Professio nal judgeme nt No significant irritation Serious Eye Damage/Irritation Name Species Value Zinc Borate 2335 Rabbit Severe irritant Polymer (NJTS Reg. No. 04499600-7270)Professio nal judgeme nt Mild irritant Sodium Silicate Rabbit Corrosive Iron Oxide Rabbit No significant irritation Polyethylene Glycol Rabbit Mild irritant Oxide glass chemicals Professio nal judgeme nt No significant irritation Skin Sensitization Name Species Value Zinc Borate 2335 Guinea pig Not classified Sodium Silicate Mouse Not classified Iron Oxide Human Not classified Polyethylene Glycol Guinea pig Not classified Respiratory Sensitization For the component/components, either no data are currently available or the data are not sufficient for classification. Germ Cell Mutagenicity Name Route Value Zinc Borate 2335 In Vitro Some positive data exist, but the data are not sufficient for classification Sodium Silicate In Vitro Not mutagenic Sodium Silicate In vivo Not mutagenic Iron Oxide In Vitro Not mutagenic Polyethylene Glycol In Vitro Not mutagenic Polyethylene Glycol In vivo Not mutagenic Oxide glass chemicals In Vitro Some positive data exist, but the data are not sufficient for classification Quartz Silica In Vitro Some positive data exist, but the data are not sufficient for classification Quartz Silica In vivo Some positive data exist, but the data are not sufficient for classification Carcinogenicity Name Route Species Value Iron Oxide Inhalation Human Some positive data exist, but the data are not sufficient for classification Polyethylene Glycol Ingestion Rat Not carcinogenic Oxide glass chemicals Inhalation Multiple animal species Some positive data exist, but the data are not sufficient for classification Quartz Silica Inhalation Human and animal Carcinogenic Reproductive Toxicity 3M Brand Fire Barrier CP-25WB+ 02/25/21 __________________________________________________________________________________________ Page 9 of 12 Reproductive and/or Developmental Effects Name Route Value Species Test Result Exposure Duration Zinc Borate 2335 Ingestion Toxic to male reproduction Rat NOAEL 100 mg/kg/day 92 days Zinc Borate 2335 Ingestion Toxic to development Rat LOAEL 100 mg/kg/day during gestation Sodium Silicate Ingestion Not classified for development Mouse NOAEL 200 mg/kg/day during gestation Polyethylene Glycol Ingestion Not classified for female reproduction Rat NOAEL 1,125 mg/kg/day during gestation Polyethylene Glycol Ingestion Not classified for male reproduction Rat NOAEL 5699 +/- 1341 mg/kg/day 5 days Polyethylene Glycol Not Specified Not classified for reproduction and/or development NOEL N/A Polyethylene Glycol Ingestion Not classified for development Mouse NOAEL 562 mg/animal/da y during gestation Target Organ(s) Specific Target Organ Toxicity - single exposure Name Route Target Organ(s)Value Species Test Result Exposure Duration Zinc Borate 2335 Inhalation respiratory irritation Some positive data exist, but the data are not sufficient for classification similar health hazards NOAEL Not available Sodium Silicate Inhalation respiratory irritation May cause respiratory irritation official classifica tion NOAEL Not available Polyethylene Glycol Inhalation respiratory irritation Not classified Rat NOAEL 1.008 mg/l 2 weeks Specific Target Organ Toxicity - repeated exposure Name Route Target Organ(s)Value Species Test Result Exposure Duration Zinc Borate 2335 Inhalation immune system | respiratory system | heart | endocrine system | hematopoietic system | liver | nervous system | kidney and/or bladder Not classified Rat NOAEL 0.15 mg/l 2 weeks Zinc Borate 2335 Ingestion endocrine system | liver | kidney and/or bladder | heart | skin | bone, teeth, nails, and/or hair | hematopoietic system | immune system | nervous system | eyes | respiratory system | vascular system Not classified Rat NOAEL 375 mg/kg/day 92 days Sodium Silicate Ingestion kidney and/or bladder Some positive data exist, but the data are not sufficient for classification Dog LOAEL 2,400 mg/kg/day 4 weeks Sodium Silicate Ingestion endocrine system | blood Not classified Rat NOAEL 804 mg/kg/day 3 months Sodium Silicate Ingestion heart | liver Not classified Rat NOAEL 1,259 mg/kg/day 8 weeks 3M Brand Fire Barrier CP-25WB+ 02/25/21 __________________________________________________________________________________________ Page 10 of 12 Iron Oxide Inhalation pulmonary fibrosis | pneumoconiosis Not classified Human NOAEL Not available occupational exposure Polyethylene Glycol Inhalation respiratory system Not classified Rat NOAEL 1.008 mg/l 2 weeks Polyethylene Glycol Ingestion kidney and/or bladder | heart | endocrine system | hematopoietic system | liver | nervous system Not classified Rat NOAEL 5,640 mg/kg/day 13 weeks Oxide glass chemicals Inhalation respiratory system Not classified Human NOAEL not available occupational exposure Quartz Silica Inhalation silicosis Causes damage to organs through prolonged or repeated exposure Human NOAEL Not available occupational exposure Aspiration Hazard For the component/components, either no data are currently available or the data are not sufficient for classification. Please contact the address or phone number listed on the first page of the SDS for additional toxicological information on this material and/or its components. SECTION 12: Ecological information Ecotoxicological information Test Organism Test Type Result Water flea, Daphnia magna 48 hours Aquatic Toxicity - Acute 27 mg/l Green algae, Pseudokirchneriella subcapitata 72 hours Aquatic Toxicity - Chronic 2.6 mg/l Please contact the address or phone number listed on the first page of the SDS for additional ecotoxicological information on this material and/or its components. Chemical fate information Please contact the address or phone number listed on the first page of the SDS for additional chemical fate information on this material and/or its components. SECTION 13: Disposal considerations 13.1. Disposal methods Dispose of contents/ container in accordance with the local/regional/national/international regulations. Dispose of waste product in a permitted industrial waste facility. As a disposal alternative, incinerate in a permitted waste incineration facility. Proper destruction may require the use of additional fuel during incineration processes. Empty drums/barrels/containers used for transporting and handling hazardous chemicals (chemical substances/mixtures/preparations classified as Hazardous as per applicable regulations) shall be considered, stored, treated & disposed of as hazardous wastes unless otherwise defined by applicable waste regulations. Consult with the respective regulating authorities to determine the available treatment and disposal facilities. SECTION 14: Transport Information For Transport Information, please visit http://3M.com/Transportinfo or call 1-800-364-3577 or 651-737-6501. SECTION 15: Regulatory information 15.1. US Federal Regulations Contact 3M for more information. 3M Brand Fire Barrier CP-25WB+ 02/25/21 __________________________________________________________________________________________ Page 11 of 12 EPCRA 311/312 Hazard Classifications: Physical Hazards Not applicable Health Hazards Reproductive toxicity Serious eye damage or eye irritation This material contains a chemical which requires export notification under TSCA Section 12[b]: Ingredient (Category if applicable)C.A.S. No Regulation Status Triphenyl Phosphate 115-86-6 Toxic Substances Control Act (TSCA) 4 Test Rule Chemicals Applicable 15.2. State Regulations 15.3. Chemical Inventories The components of this material are in compliance with the provisions of Australia National Industrial Chemical Notification and Assessment Scheme (NICNAS). Certain restrictions may apply. Contact the selling division for additional information. The components of this product are in compliance with the new substance notification requirements of CEPA. The components of this material are in compliance with the China "Measures on Environmental Management of New Chemical Substance". Certain restrictions may apply. Contact the selling division for additional information. The components of this material are in compliance with the provisions of the Korean Toxic Chemical Control Law. Certain restrictions may apply. Contact the selling division for additional information. The components of this product are in compliance with the chemical notification requirements of TSCA. All required components of this product are listed on the active portion of the TSCA Inventory. 15.4. International Regulations This SDS has been prepared to meet the U.S. OSHA Hazard Communication Standard, 29 CFR 1910.1200. SECTION 16: Other information NFPA Hazard Classification Health: 2 Flammability: 1 Instability: 0 Special Hazards: None National Fire Protection Association (NFPA) hazard ratings are designed for use by emergency response personnel to address the hazards that are presented by short-term, acute exposure to a material under conditions of fire, spill, or similar emergencies. Hazard ratings are primarily based on the inherent physical and toxic properties of the material but also include the toxic properties of combustion or decomposition products that are known to be generated in significant quantities. Document Group:09-5451-1 Version Number:26.08 Issue Date:02/25/21 Supercedes Date:03/20/20 DISCLAIMER: The information in this Safety Data Sheet (SDS) is believed to be correct as of the date issued. 3M MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR COURSE OF PERFORMANCE OR 3M Brand Fire Barrier CP-25WB+ 02/25/21 __________________________________________________________________________________________ Page 12 of 12 USAGE OF TRADE. User is responsible for determining whether the 3M product is fit for a particular purpose and suitable for user's method of use or application. Given the variety of factors that can affect the use and application of a 3M product, some of which are uniquely within the user's knowledge and control, it is essential that the user evaluate the 3M product to determine whether it is fit for a particular purpose and suitable for user's method of use or application. 3M provides information in electronic form as a service to its customers. Due to the remote possibility that electronic transfer may have resulted in errors, omissions or alterations in this information, 3M makes no representations as to its completeness or accuracy. In addition, information obtained from a database may not be as current as the information in the SDS available directly from 3M. 3M USA SDSs are available at www.3M.com