Signed Inspection Report (Tue Apr 27, 2021 at 1141 AM)INSPECTION WORKSHEET (FDTN-009897-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0507-2020 Case Module:Permit
Inspection Date:Tue Apr 27, 2021 Inspection Status:Partial Pass
Inspector:Dyer, Charles Inspection Type:Building Foundation
Job Address:Parcel Number:323 LUZERNE RD
Queensbury, NY, 12804
308.12-2-58
Contact Type Company Name Name
Architect G. Peter Jensen Architect
Primary Owner Bell, Marie
Roofing Contractor Apex Solar Power
Siding Contractor LaRose, Mike
Applicant Bell, Jamie
Granted Permission Bell, Jamie
Concrete Contractor Ottens Concrete
Granted Permission Bell, Marie
Framing Contractor Top Notch Builders
Contractor Precision Contruction Plus
Checklist Item Status
Permit Card Visible From Road Passed
At windows right of front entry
Building Inspector Notes Failed
Footings Passed
Apr 27, 2021 Page (1)
INSPECTION WORKSHEET (FDTN-009897-2021)
Checklist Item Status
Approved 4/27/21
Piers Failed
Reinforcement in Place Passed
With 3 rows #4 continuous
Foundation / Wallpour Failed
Reinforcement in Place Failed
Masonry Wall Failed
Reinforcement in Place Failed
Footing Dowels or Keyway in place Failed
Foundation Dampproofing Failed
Foundation Waterproofing Failed
Footing Drain Daylight or Sump Failed
Footing Drain Stone - 12 inch width Failed
Apr 27, 2021 Page (2)
INSPECTION WORKSHEET (FDTN-009897-2021)
Checklist Item Status
Footing Drain Stone - 6 inches above footing Failed
Footing Drain stone - 6 mil poly Failed
Backfill Approval Failed
Plumbing Under Slab Failed
PVC / Cast / Copper Failed
Foundation Insulation Interior / Exterior Failed
Rough Grade 6 inch drop within 10 ft.Failed
Poly Under Slab Failed
Apr 27, 2021 Page (3)
Dyer, Charles