Loading...
Signed Inspection Report (Tue Apr 27, 2021 at 1148 AM)INSPECTION WORKSHEET (FDTN-009928-2021) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0148-2021 Case Module:Permit Inspection Date:Tue Apr 27, 2021 Inspection Status:Partial Pass Inspector:Dyer, Charles Inspection Type:Building Foundation Job Address:Parcel Number:32 Petrie LN Queensbury, NY, 12804 308.6-1-61 Contact Type Company Name Name Granted Permission WAHNON, SAMUEL Contractor Glens Falls M & M, Inc. Applicant WAHNON, SAMUEL Primary Owner Queensbury Village Checklist Item Status Permit Card Visible From Road Failed Building Inspector Notes Failed Permit has not been issued for placement of manufactured home due to no manufactured home serial numbers or model numbers, please provide data Footings Failed Piers Failed Monolithic Slab Passed Apr 27, 2021 Page (1) INSPECTION WORKSHEET (FDTN-009928-2021) Checklist Item Status Reinforcement in Place Failed Foundation / Wallpour Failed Reinforcement in Place Failed Masonry Wall Failed Reinforcement in Place Failed Footing Dowels or Keyway in place Failed Foundation Dampproofing Failed Foundation Waterproofing Failed Footing Drain Daylight or Sump Failed Footing Drain Stone - 12 inch width Failed Footing Drain Stone - 6 inches above footing Failed Footing Drain stone - 6 mil poly Failed Apr 27, 2021 Page (2) INSPECTION WORKSHEET (FDTN-009928-2021) Checklist Item Status Backfill Approval Failed Plumbing Under Slab Failed PVC / Cast / Copper Failed Foundation Insulation Interior / Exterior Failed Rough Grade 6 inch drop within 10 ft.Failed Poly Under Slab Failed Apr 27, 2021 Page (3) Dyer, Charles