Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
blower door report
Testing Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:17 Alessia Address:17 Alessia Dr Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.277340 Longitude: -73.722744 Timestamp: 2021-04-29 08:49:02 Customer Information: Name:Cerrone Builders Address: Measured Leakage:940.0 CFM50 Test ID:17 Alesia Purpose of Test:RESNET Multi-Pt Env. Leakage Measured ACH50:2.15 (+/- 2.5%)Effective Leakage Area: 50.6 in² Building Volume:26,250.0 ft³Enclosure Surface Area: 3,000.0 ft² Coefficient (C):71.5 (+/- 11.4%)Exponent (n): 0.658 (+/- 0.033) Correlation Coefficient:0.99963 Test Standard:RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 63 °F Altitude: 412.0 ft Outdoor Temp: 49 °F Time Average Period: 10 seconds Test Date and Time:2021-04-29 08:59:24 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -0.3 -60.0 -60.0 -59.7 -34.7 1,071.2 Ring A -48.0 -48.0 -47.7 -26.2 934.2 Ring A -35.0 -34.2 -34.0 -164.4 760.2 Ring B -23.0 -24.3 -24.0 -101.8 599.5 Ring B -10.0 -11.9 -11.6 -37.6 366.0 Ring B Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3173 Custom Calibration Date: 2021-02-10 Pressure Gauge:DG1000 Serial #: 5193 Calibration Date: 2020-01-16 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.7.3 (91), © 2020 The Energy Conservatory, Inc.