Signed Inspection Report (Thu Apr 29, 2021 at 330 PM)INSPECTION WORKSHEET (RESFINAL-010035-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0544-2020 Case Module:Permit
Inspection Date:Thu Apr 29, 2021 Inspection Status:Passed
Inspector:Dyer, Charles Inspection Type:Residential Final Inspection
Job Address:Parcel Number:26 ALESSIA DR
Queensbury, NY, 12804
315.10-1-43
Contact Type Company Name Name
Architect Vision Engineering
Applicant CERRONE BUILDERS, INC.
Granted Permission CERRONE BUILDERS, INC.
Contractor CERRONE BUILDERS, INC.
Primary Owner CERRONE BUILDERS, INC.
Checklist Item Status
General Comments Passed
4 inch Building Number Address visible from road Passed
Chimney Height / B Vent / Direct Vent Location Passed
Fresh Air Intake Passed
Fresh air supply 3' from grade Passed
Apr 29, 2021 Page (1)
INSPECTION WORKSHEET (RESFINAL-010035-2021)
Checklist Item Status
3" Plumbing Vent through roof minimum 18 inch Passed
Outside Spigots have Air Gap Passed
Roof Complete / Exterior Finish Complete Passed
Platform at all exterior doors Passed
Handrail 4 or more risers Passed
Guards at stairs,decks,patios 30" + above grade Passed
Guard at stairwell at 34" or more Passed
Window guards req:<2' above floor/6' above grade - quick release installed Passed
Guard at deck, porches 36" or more Passed
Handrail Termination at Newell Post or Wall Passed
Interior/Exterior Railings 34 to 38 Passed
Wood deck: 2'+ from grade dia bracing required - H/C ramp compliant Passed
Apr 29, 2021 Page (2)
INSPECTION WORKSHEET (RESFINAL-010035-2021)
Checklist Item Status
4+ Deck Joist Ledger Connections-24" From Ends Passed
Deck Ledger-Bolted per Code Passed
Grade away from foundation: 6" down, 10' out Passed
6" clearance to sill plate Passed
Gas Shut-off Exposed & Regulator (18) Above Grade Passed
Interior privacy/trim/doors/main entrance 36 Passed
Bathroom / Kitchen Watertight Passed
Low flow toilet 1.3 gal/flushing cycle - showerhead/faucet Passed
Safety glazing: w/in 5' of tub/shower - stairwell win/adj to drs Passed
Smoke Detectors:Passed
Smoke Detectors 3' from Kitchens & Baths R314 Passed
Apr 29, 2021 Page (3)
INSPECTION WORKSHEET (RESFINAL-010035-2021)
Checklist Item Status
Every level, Every bedroom Passed
Outside every bedroom area Passed
Battery backup: _____Passed
Inter Connected Passed
Carbon Monoxide Detectors:Passed
CO Detectors within 10' of all sleeping areas Passed
Attic Access 22 x 30 minimum Passed
Attic Access Insulation = Attic R- Value Passed
Attic Access Gasketed Passed
Foam in basement/attics covered w/thermal barrier Passed
At rim joist area
Bathroom Fans, if no window Passed
Plumbing fixtures Passed
Apr 29, 2021 Page (4)
INSPECTION WORKSHEET (RESFINAL-010035-2021)
Checklist Item Status
Backflow Preventors where required Passed
Foundation insulation to floor Passed
Energy Sticker on Elec. Panel:R-Val. & Heating Sys Passed
All Hot Water Systems: 3/4" or larger piping R-3 Passed
Duct work sealed properly Passed
Intake Openings Passed
Range Hood 400+ cfm-Fresh Air REQUIRED Passed
Blower Door Test Certification Passed
Received
HRV or ERV Installed per Bedroom Requirements Passed
Emergency egress below grade Passed
Furnace shut-off w/in 30 ft. or w/in line of site Passed
Apr 29, 2021 Page (5)
INSPECTION WORKSHEET (RESFINAL-010035-2021)
Checklist Item Status
Furnace/Hot Water Heater operating Passed
Relief Valve ,Heat Trap/Water Temp 110 deg or less Passed
1/2" Gypsum or House Wall and Gable Passed
20 Minute Fire Door/Self-Closing Hardware Passed
Seals on Garage Doors, esp. Wood Passed
Basement stairs closed rise greater than 4 inches Passed
Basement Egress: 5s.f. window w/sill or Bilco door Passed
Walkout
Jack posts in basement lagged at top and bottom Passed
Garage Floor Pitched Passed
Gas Log In Sealed or Glass Enclosure Passed
Fin Elect; Energy Saving Light Bulbs 50 Percent Passed
Final Survey Plot Plan Passed
Apr 29, 2021 Page (6)
INSPECTION WORKSHEET (RESFINAL-010035-2021)
Checklist Item Status
Received
Arc Fault Breaker Habitable Spaces Passed
Flex Gas Pipe Bonding Passed
As Built Septic System Passed
Received
Flood Plain Certification, if required Passed
No
Fuel Tanks above flood plain elevation Passed
No
Buried Fuel Tanks anchored in flood zone Passed
No
Truss ID Signage Installed at Electrical Meter Passed
OK to Issue C/O Passed
Provide blower door test
Final survey
Asbuilt for septic
All items received 4/29/21
Apr 29, 2021 Page (7)
Dyer, Charles