Signed Inspection Report (Tue May 4, 2021 at 1034 AM)INSPECTION WORKSHEET (COMFIN-009999-2021) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0058-2021 Case Module:Permit Inspection Date:Tue May 4, 2021 Inspection Status:Failed Inspector:O'Brien, John Inspection Type:Commercial Final Inspection Job Address:Parcel Number:1444 State Rte 9 Lake George, NY, 12845 288.12-1-22 Contact Type Company Name Name Granted Permission Eddie Bauer Contractor Catone Construction Applicant Kohls, Laura Primary Owner ADK Factory Outlet Mall Checklist Item Status Blower Door Test Certification Failed Building Inspector Notes Failed 5/4/21 Commercial Final Inspection Not Approved Remaining Items: - Install mirror over sink. Bottom of mirror 40" max from finished floor. - Verify hot water - Close up all remaining electrical work and verify final electrical. - Install handicapped bathroom and dressing room signage on wall latch side of door 60" to center of sign from finished floor. - Install door threshold and door sweep at exterior door of stock room. - Install store suite number on exterior window and mall interior entrance window. - Complete all Fire Marshal's Items. Chimney / B Vent / Direct Vent Location Passed May 04, 2021 Page (1) INSPECTION WORKSHEET (COMFIN-009999-2021) Checklist Item Status Chimney Rain Cap Installed Failed Plumbing Vent Through Roof/Roof complete Passed Lllllllllllllllllllllllllllllll Llll Ext Finish /Grade Complete/6 in 10ft or Equivalent Passed Lll Ll Wood deck: 2'+ from grade dia bracing required - H/C ramp compliant Failed Int/Ext Guardrails 42 inch Platform Decks Failed May 04, 2021 Page (2) INSPECTION WORKSHEET (COMFIN-009999-2021) Checklist Item Status Int/Ext Balusters 4 inch Spacing Platform Decks Failed ÿþ Failed 12" beyond top & bottom Failed Step risers: riser 7" & treads 11"Failed Vestibules for Exit doors greater than 3000 sq. ft Failed Doors 36 inch wLever Hand Panic Hardware, if req Passed Exits At Grade Or Platform 36 (w) x 44 (l)Failed - Install door threshold and door sweep at exterior door of stock room. Gas Shut-off Exposed & Regulator (18) Above Grade Failed Floor Bathroom Watertight Other Floors Okay Passed Backflow Preventors where required Failed Relief Valve ,Heat Trap/Water Temp 110 deg or less Failed - Verify hot water May 04, 2021 Page (3) INSPECTION WORKSHEET (COMFIN-009999-2021) Checklist Item Status Outside Spigots have Air Gap Failed Jack posts in basement lagged at top and bottom Failed Boiler/Furnace Enclosurer Fire Ext System Failed Low Water Shut Off for Boilers Failed Gas Furnace Shut Off Failed HVAC Vent Terminal 10' from Lot Line & Openings Failed Oil Furnace Shut-Off at Entrance to Furnace Area Failed Propane Tank: Proper Setback from Prop Line/Struct Failed Stockroom /Storage/Receiving/Shipping Room Failed ¾ Hour Corridor Doors & Closers Failed Firewalls, 2 Hr, 3 Hr / Fire Dampers / Fire Doors Failed Ceiling Fire Stopping, 3,000 sq. ft. Wood Frame Failed May 04, 2021 Page (4) INSPECTION WORKSHEET (COMFIN-009999-2021) Checklist Item Status Attic Access 30 x 20 x 30 (h)Failed Attic Access Gasketed Failed Attic Access Insulation = Attic R- Value Failed Foam in basement/attics covered w/thermal barrier Failed Smoke Vents Or Fan, if required Failed Hydraulic Elevators: Non-comb. Plumbing REQUIRED Failed Hydraulic Elevators: Oil Seperator REQUIRED Failed Elevator Operation and Signage Shaft Sealed Failed H/C toilet flush handle on open side Passed H/C side & rear grab bars 36" above floor Passed H/C grab bar: 42" side, 12" from center Passed May 04, 2021 Page (5) INSPECTION WORKSHEET (COMFIN-009999-2021) Checklist Item Status H/C 18" minimum vertical grab bar Passed H/C vertical grab bar 39" from floor and corner Passed H/C rear grab bar 36" with 24" to open side Passed H/C mirrors 40" above floor Failed - Install mirror over sink. Bottom of mirror 40" max from finished floor. H/C sinks 34" above floor Passed Handicapped Bath/Parking Lot Signage Failed - Install handicapped bathroom and dressing room signage on wall latch side of door 60" to center of sign from finished floor. Low flow toilet 1.3 gal/flushing cycle - showerhead/faucet Passed Universal Symbol of Access displayed - on all H/C signs Failed - Install handicapped bathroom and dressing room signage on wall latch side of door 60" to center of sign from finished floor. Public Toilet Room Handicapped Accessible Failed Handicapped Service Counters 34 inch Passed Handicapped Ramps Failed May 04, 2021 Page (6) INSPECTION WORKSHEET (COMFIN-009999-2021) Checklist Item Status Ramps: 6" or more need handrails Failed Ramps: 4" toe kick each side of ramp Failed Ramps: 12" extension top & bottom Failed Handicapped Units Failed Individual storage units 5% of each type Failed Active Listening System and Signage Assembly Space Failed Bollard Protection:4' on ctr/3' abv grd, gas meter Failed Bollard Protection: 15" footings & 3' below grade Failed Final Electrical / Flex Gas Piping Bonded Failed - Close up all remaining electrical work and verify final electrical. Occupancy sensor lighting control Passed Bldg Num or Tenant Address on Bld or Drive Failed - Install store suite number on exterior window and mall interior entrance window. Bldg Access All Sides 20ft Drivable Surface Passed May 04, 2021 Page (7) INSPECTION WORKSHEET (COMFIN-009999-2021) Checklist Item Status OK to Issue Temporary C/O Failed OK to Issue C/O Failed May 04, 2021 Page (8) O'Brien, John