Signed Inspection Report (05-12-2021) (4).pdf Rough, Plu' Ong / Insul tlon spsotlon' Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Coda Enforcement Ahive:�arn/pm Depart: pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initial% T�
NAME: d P1 PERMIT :
LOCATION: INSPECT ON: L —C�
TYPE OF STRUCTURE: o
Y N N/A
Rough Plumbing./Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout eve 100 feet I change of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above hi hest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ ad
S.] fbr,15 minutes
Insulation/R sidential Check/Commercial Check
ilar Exterior Sealant }
Proper Vent, Attie Vent
Door/Window Sealed No Insulation
Duct,/-'Hot Water Piping Insulation
If r 'uired'unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
rz
7/
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection reqr#:
Queensbury Building &�Code Enforcement Arrive: 1 :, a 742 Bay Road, Queensbury, NY 12804 Inspector's Initial :NAME: A� , - MI
LOCATION: t �,���� n Q, 1, INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing/Nail Plates
Plumbing Vent/Vents in Place
1 Y2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
F0W .er Supply Piping
Head
S.I for 15 minutes
Insulation / Residential Check/Commercial Check
V Tyv6k or Similar Exterior Sealant p -
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing 9 Firestopping Inspection Report-
Office No. (518)761-8256 Date Ins"pection u r
Queensbury Building &Code Enforcement Arrive: m part:
742 Bay Road, Queensbury, NY 12804 Inspector's Initials
NAME: RMIT M l ��
LOCATION: NSPECT ON:
EFramin
STRUCTURE:
Y td NIA COMMENTS:
ss 220 x 30° minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
aft stopping 1,000 sq. ft. floor trusses
lt�chor Bolts 6 ft. or less on center
Ice and water ield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cav' min.
Garage Fire Separation
House side%inch or 518 inch Type X
Garage side 518 inch Type X
Ceilingfwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-OLD113uilding&CodesUnspection FonnsTraming Firestopping Inspection ReporLdoc Revised January 7,2008
Foundation Inspection Report
Office No.(518)7.61-8256 Date Iris%ectiong' reQueensbury Building&Code Enforcement Arrive: Depart: _ : ! a742 Bay Rd.,Queensbury,NY 12804 Inspecto
NAME: A elAeA4 PE #: O ! --
LOCATION:
TYPE OF STRUCTURE:
commgm
Y N; N/A
Piers
-Mcffo-lithic Slab
Reinforcement in Place
The contractor is responsible for t
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfrll Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Buildiing&Codes\Inspection Form0oundation"Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Ins ection e e °
Queensbury Building&Code Enforcement Arrive: Depart: am1�
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial
NAME: — S P RMIT#: bc� —
LOCATION: I A INSPECT ON: -1���Z�
TYPE OF STRUCTURE:
Comments
Y N/AFootings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Fonns\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM