Signed Inspection Report (05-18-2021) (5).pdfINSPECTION WORKSHEET (FDTN-010466-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0507-2020 Case Module:Permit
Inspection Date:Tue May 18, 2021 Inspection Status:Passed
Inspector:Dyer, Charles Inspection Type:Building Foundation
Job Address:Parcel Number:323 LUZERNE RD
Queensbury, NY, 12804
308.12-2-58
Contact Type Company Name Name
Framing Contractor Top Notch Builders
Granted Permission Bell, Marie
Granted Permission Bell, Jamie
Roofing Contractor Apex Solar Power
Primary Owner Bell, Marie
Applicant Bell, Jamie
Contractor Precision Contruction Plus
Architect G. Peter Jensen Architect
Concrete Contractor Ottens Concrete
Siding Contractor LaRose, Mike
Checklist Item Status
Permit Card Visible From Road Passed
At windows right of front entry
Building Inspector Notes Passed
OK to backfill at garage area. Plans call for damp proofing at front porch walls ?
May 18, 2021 Page (1)
INSPECTION WORKSHEET (FDTN-010466-2021)
Checklist Item Status
Footings Passed
Approved 4/27/21
Reinforcement in Place Passed
With 3 rows #4 continuous
Foundation / Wallpour Passed
approved 4/29/21
Reinforcement in Place Passed
With 2 rows #4 horizontally
Footing Dowels or Keyway in place Passed
Foundation Dampproofing Passed
Provide damp proofing at porch walls
Footing Drain Daylight or Sump NA
Footing Drain Stone - 12 inch width NA
Footing Drain Stone - 6 inches above footing NA
Footing Drain stone - 6 mil poly NA
Backfill Approval Passed
At garage area only 4/30/21
Plumbing Under Slab NA
May 18, 2021 Page (2)
INSPECTION WORKSHEET (FDTN-010466-2021)
Checklist Item Status
Foundation Insulation Interior / Exterior NA
Rough Grade 6 inch drop within 10 ft.Failed
Poly Under Slab Passed
Verified 5/18/21
May 18, 2021 Page (3)
Dyer, Charles