inspections Rough, Plumbing / Insulation spectson Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depart: - /pm
742 Bay Road, Queensbury, NY 12804 Irispector's Initials• �.
r
NAME: PERMIT : 0 -/
LOCATION: lbadk.14 INSPECT ON: -�
TYPE OF STRUCTURE:
Y N NIA
Rough Plumbing]Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout eve 100 feet/change of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air LHead
—td-RSJ-1bk 15 minutes
Insulation /R sidential Check/Commercial Check
filar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct Hot Water Piping Insulation
If r 'wired'unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
7i
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection requ e
Queensbury Building &Code Enforcement Arrive: a m : J, -a m
742 Bay Road, Queensbury, NY 12804 Inspector's Initial
NAME: MIT#: -
LOCATION: f c)c��V)u� 1ti�n INSPECT ON:
TYPE OF STRUCTURE:
Y N NIA
Rough Plumbing /Nail Plates
Plumbing Vent J Vents in Place
1 Y2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/ Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
W er Supply Piping
/Head
0 P.S.I for 15 minutes
Insulation/Residential Check/Commercial Check
Tyvek or Similar Exterior Sealant Pam'
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct J Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Report revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firestopping Inspection Report ,
Office No. (518) 761-8256 Date Inspection u re
Queensbury Building &Code Enforcement Arrive: - aM m part:
742 Bay Road, Queensbury, NY 12804 Inspector's Initials
i
NAME: 4 - RMIT#: l XI
LOCATION: NSPECT ON:
g?F4raming
STRUCTURE:
Y N NIA COMMENTS:
k:ess 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C. .
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
aft stopping 1,000 sq. ft. floor trusses
Anchor Bob 6 ft. or less on center
Ice and water field 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 518 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. OM
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-OLMuilding&CodesNinspedion FornisTraming Firestopping Inspection Report.doc Revised January 7,2008
/D� z
Foundation Inspection Report
Office No.(518)7.61-8256 Date his ection re v J
Queensbury Building&Code Enforcement Arrive: e. Depart:
742 Bay Rd.,Queensbury,NY 12804 h�spector's ti
NAME: 4be&A4 PE
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
C®mmggk
Y Ns N/A
f
Piers l .
-McColthic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Fo"s\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Ins ection r e ce e
Queensbury Building&Code Enforcement Arrive: Depart: am1
742 Bay Rd.,Queensb ,NY 12804 Ins actor's Initial .
NAME: —� . S P RMIT#: C
LOCATION: i�C�(�O l tJn Ate-\ INSPEC T ON: y
TYPE OF STRUCTURE:
Commenu
Y N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM