Loading...
ResCheck 'Generated by REScheck-Web Software C�J( Compliance Certificate 4�OE NEt^�yG �'CQ PERT V D�9 'pjr . Project 147 Hudson Pointe Blvd Energy Code: 2018 IECC o 0s603A Location: Warren County, New York pRoFESS1oNP� Construction Type: Single-family Project Type: Addition Robert Mann PE Climate zone: 6 (8499 HDD)Permit Date: ®��� ��� 2020.12.18 17:50:29 -05'00 � �`'� ��® f� Permit Number: _ a V r` Construction Site: �� 0� �er/Agent: Designer/Contractor: 147 Hudson Pointe Blvd Bob &Tish O'Mara Robert Mann PE Queensbury, NY 12804 F 147 Hudson Pointe Blvd Consultant Engineering Service Queensbury, NY 12804 PLLC 5 Park Drive Troy, NY 12180 robertmannpe@gmail.com Compliance: Passes using UA trade-off Compliance: 3.26/6 Better Than Code Maximum UA: 93 Your UA: 90 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope.Assemblies Gross Area Cavity Cont. Perimeter Ceiling: Flat Ceiling or Scissor Truss 365 49.0 0.0 0.026 9 Wall: Wood Frame, 24"o.c. 569 21.0 6.0 0.040 20 Door 2: Glass Door(over 50%glazing) -i _ 22 0.300 7 p ( ',oral ! 244DH2O40:Vinyl Frame U,<�d ! 5 0.290 1 244DH2O40 Tempered:Vinyl Frame ! p ! i 5 0.300 1 �I C-) 244DH2849:Vinyl Frame r�j�, r-1, `: J 'f 9 0.290 2 244DH2O49-2:Vinyl Frame gg '-5i 12 0.290 3 244DH2849-2:Vinyl Frame C�F N i ., g 17 0.290 5 Floor: Slab-On-Grade (Unheated) 78 10.0 0.360 28 Insulation depth: 0.5' 4 Crawl: Solid Concrete or Masonry ��- -- 365 0.0 15.0 0.057 14 Wall height: 6.0' Depth below grade: 4.0' Insulation depth: 6.0' FILE COPY 315.7-2-94 RC-0725-2020 O'Mara, Robert 147 Hudson Pointe Blvd Residential Add/Septic 360 s.f. Project Title: 147 Hudson Pointe Blvd Report date: 12/18/20 Data filename: Page 1 of 2 r Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signatun Date CO 9of NEW;,, �at v Ag QF CFO 09603a <t�� A�o�SStoN�� Robert Mann PE 2020.12.18 17:50:43 -05'00 Project Title: 147 Hudson Pointe Blvd Report date: 12/18/20 Data filename: Page 2 of 2 2018 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 27.00 Below-Grade Wall 15.00 Floor 10.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass& Door Rating U-Factor SHGC Window 0.29 Door 0.30 CoolingHeating & Heating System: -Cooling System: Water Heater: Name: Date: Comments nrFa e��v y. 0 Ui 09603A RO ss�o�'� Robert Mann PE 2020.12.18 17:51:00 -05'00