2000-405 TOWN OF QUEENSBURY. woo^Ai
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development.-Building & Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
C/C Number: 0000405 C/C Date: Thursday, August 24, 2000
Application Number:2000405
Permit Number: 2000405
This is to certify that work requested to be done as shown by Permit Number 2000405
has been completed.
This structure may be used as a Sept a-Alteration
Tax Map Number: 523400-018-000-0001-020-000-0000
Location: 147 PILOT KNOB Rd
Owner: ROBERT &DONNA PHILLIPS
By Order f Town Board
TOW OF Q ENS RY
zi
Director of Building&Code Enforcement
BUILDING PERMIT
Town of Queensbury, 742 Bay Road, Queensbury,NY 12804
County of Warren (518) 761-8256
VALUE $ 0 Building Permit No. 2000405
TAX MAP NO. :18 . -1-20
PHILLIPS, ROBERT & DONNA
Permission is hereby granted to
147 PILOT KNOB RD.
Owner of property located at
in the Town of Queensbury,to construct or place a SEPTIC ALTERATION
at the above location in accorcianrP to application together with plot plans and other information hereto filed and
approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance.
Owner's Address:
P .O. BOX 188
KATTSKILL BAY, NY 12844
Contractor or Builder's Name:
Contractor or Builder's Address:
Electrical Inspection Agency:
Type of Construction:
SEPTIC
Plans and Specifications:
SEPTIC ALTERATION AS PER PLOT PLAN SPECIFICATIONS
•
Proposed Use:
SEPTIC ALTERATION
25 - June 14 . . 2002.
$ PERMIT FEE PAID—THIS PERMIT EXPIRES
(If a longer period is required,an application for an extension must be made to the Code Enforcement
Officer of the Town of Queensbury before the expiration date.)
14 June 2000
Dated at the T wn of Queensbury this Day of
SIGNED BY for the Town of Queensbury
Code Enforcement Officer .
Application for Permit—Septic Disposal System
Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256
1. OWNER INFORMATION:
Office Use ,
Location of installation: 1(0?h',3 /e0 k-D
File Permit No4�
Tax Map No. 48 / l / 45.2 •
Owner's Name: 0O�ex j F Adti�� �N i ✓�� j Fee Paid J v =
Address: 1' ) 4r k,c14 ' 4D,!?BY /V)/( . 1e+T7U/ /- ,4��9r /28¢1)
2. INSTALLER'S NAME : PHONE NO. P 'rzb
3. RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply# of k---tzivetj
bedrooms with applicable gallons per bedroom to equal total daily flow` N 0 9 2000
Ow�.�Ofi
Year of House: No. of Bedrooms x Computation = Total Daily Flo Bv11.piNG JIySBu�y
AliDcoo .
1980 or older x 150 gal/bdrm =
1980— 1991 x 130 gal/bdrm =
1991 —present S' x 110 gal/bdrm = 5-5-0
Gip
Garbage Grinder Installed yes / no �/
Spa or Whirlpool Installed yes / no V
4. PARCEL INFORMATION: (circle applicable information&indicate measurements)
Topography Soil Nature Ground Water Bedrock or Impervious Material Domestic Water Supply
Flat sand at w t depth at what depth ynlcnlGrE,al
Rolling loam h// feet //4,2/ feet -we1l-
Steep slope clay
� � �0 ,4�70� if well; water supply
slopeother er from any septic-system
depth: absorption is?/4, ft.
other
Percolation Test: (To be completed by licensed professional engineer or architect)
Rate: /2. minute per inch
5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed
professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size
of the septic tank and leach field for each Garbage Grinder, Spa or Whirlpool Tub.
Septic Tank: /S'OD gallon (min. size 1,000 gal)
Tile Field: each trench f? Total System Length: ft.
Seepage Pit(s): number of size of each: ft. by ft.
Size of Stone to be used: # / depth or thickness feet
Bed System Size: x
Alternative System: '4 /4/ length and/or size o
6. HOLDING TANK SYSTEM: (if required)
Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons
Note: Alarm System and associated electrical work must be inspected by a Town approved
electrical inspection agency.
7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read)
For your protection,please note that pursuant to Section 136-29 of the Code of the Town
of Queensbury, any permit or approval granted which is based upon or is granted in
reliance upon any material misrepresentation or failure to make a material fact or
circumstance known by or on behalf of an applicant, shall be void.
I have read the regulations with respect to this application and agree to abide by these and all
requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance.
CV/r,&e.404,4 , 5'4 /t. .
Signature of responsible person Date
v
TOWN OF QUEENSBURY
BUILDING & CODE ENFORCEMENT /69)
742 Bay Road
Queensbury NY 12804
(518) 761-8256
SEPTIC DISPOSAL SYSTEM INSPECTION
Name ?kQL0
Location ITT � �s' �� Vl�/ (-0-)
11 I
Date , , 1//lAArmi t #�� 0—
r4
SOIL, TYPE: Sand-Loam-Clay-
Results of Percolation Test-
(if apOicable) Rate-Minute/Inch
TYPE OF 'SYSTEM: t�,� 1
ABSORPTION\FIELD: Total Len,g nth 6 G Cc-jC.ti
Length of each trench ►'h.��`t 5`{s
Depth of trenches j8 \
Size of steno `a, A"30\
SEEPAGE PITS: Number- \
Size - ft.\x \ ft.
Stone size
PIPING: Sire Type.
Bldg. to Tank
Tank to Dist. Box V /
Dist. Box to Field/ i , u N
Openings Sealed? Yes No Partial
LOCATION1/SEPARATION •
Foundation to Tank ,..feet
Foundation to Absorption . kfe.et . .
Separation of Pits et
Conforms as pe ' . . . es No
LOCATION OF STEM ON Y.
(circle one) . &iM ' ItXE-
Front - Rear Left Side Rii , t Side
Middle Front - - Re.
COMMENTS: .
•
;\ISYSTEM.USE APPROVED: YES NO
Arrived: _r_o<
Departed:
Building Inspector
NOTE "IN— DRAIN " AD50RFTI0N 5Y5TEM EK051DN CONTROL, — HAY DALE
THE 51TE PLAN BELOW 15 AN INSET OF THE TOP06RAPHIG
MAP ATTAGHED TO THESE PLANS. IT AND II.TO RAISE THE GRADE WITH4 DE NEGEc25ARY TO EMODENSE SANDY OAM RIAT 5 ALL EROSION CONTROL MEASURES SHALL CONFORM TO NEW YORK STATE GUIDELINES FOR URBAN
15 E55ENTIAL. TO GOMPAGT EMDANKMENT MATERIAL TO ITS EROSION and SEDIMENT CONTROL."
NEW WATER WELL NOTE MAXIMUM PRACTICAL DENSITY TO AVOID SETTLEMENT. BEFORE ANY CLEARING OR GRUBBING OF THE CONSTRUCTION SITE IS BEGUN. AND DURING THE
'IN-DRAIN' UNITS ARE LAID IN 5TRAIC-IHT ROWS ON DEAD LEVEL EARTHWORK PHASES. EFFECTIVE SEDIMENT TRAPS SHALL BE CONSTRUCTED.
PLEASE TAKE NOTE THAT A PROPDSED NEW WATER WELL CONCRETE SAND AS SHOWN ON SHEET 2. THERE SHALL BE
MU5T DE A MINIMUM OF 100 FEET DISTANT FROM ANY PART NOT LE55 THAN 24' OF DENSE SANIDY LOAM ABOVE ROCK OR SEDIMENT TRAPS SHALL CONSIST OF HAY BALES PLACED SO AS TO FORM A PERVIOUS BARRIER TO
OF THE WASTEWATER ABSORPTIDN SYSTEM. THE WELL IMPERVIOUS STRATUM OR GROUNDWATER. 'IN-DRAIN UNITS SHALL THE MOVEMENT OF SEDIMENTS DURING CONSTRUCTION.
MUST DE SITUATED GENERALLY AS SHOWN ON THE SURVEY DE INSTALLED IN AGGORD WITH MANUFAGTURER'5 DIREGTION5. AT LEAST TWO WOODEN OR METAL SPIKES SHALL BE DRIVEN THROUGH EACH BALE TO ANCHOR IT
MAP. IN PLACE. CONVENTIONAL SNOW FENCING MAY BE USED IN LIEU OF STAKES TO STABILIZE HAY-BALE
I � FAt3 (�IG — CMDST IM�'OI� TANT ! ) SEDIMENT TRAPS.
A D J A G E N T LOT WATER W E L L � F LT E ALL BARE-EARTH AREAS SHALL BE SEEDED AND MULCHED AS SOON AS PRACTICABLE TO PREVENT
THERE EX15T NO WATER WELLS WITHIN 100 FEET OF THE IT IS CRITICAL TO LAY FILTER FADRIIG BETWEEN SOIL LAYERS EROSION AND THE TRANSPORT OF SEDIMENTS TO THE LAKE.
ABSORPTION 5Y5TEM. TO PREVENT MIGRATION OF 5011, PAF:TIGLE5 FROM ONE LAYER
TO ANOTHER. 51 L T F E N G E
FILTER FADRIG MU5T BE PLAGED ON THE UPGRADE 51DE OF THE
PROPOSED STONE WALL TO PRECLUDE 5UD51DENGE OF EMBANKMENT
501L.5 DUE TO WATER SEEPAGE.
51LT FENGING MAY DE U5E0 IN GONJUNGTION WITH HAY DALE5 A5 A 5EGONDARY
DARKIER TO THE MOVEMENT DOWNGRADIENT OF SOIL PARTIGLE5. SILT FENGING
SHOULD DE EREGTED DOWNSLOPE FROM HAY BALES A5 MAY DE NEGE55AKY.
THE IMPORTANT ODJEGTIVE 15 TO KEEP 501L5 FROM GETTING INTO THE LAKE BEFORE
THE ESTADLI5HMENT OF GRASS VEGETATION.
o
0
SILT DARRIER
A5 MAY DE "�-- 10,
I_ 5'- 0' _I FIN 6RADE
REQUIRED _` GEOTEXTILE
4' - V TOP1501L
FILTER FADRIG 4' MIN TOP501L .. Y • Y ' ' �'Y;� ' :'�' '�'�
SEED TO 6RA55 M1, .' ',':::
/ GRANULAR !, �'
/./FIN
FIN 6RADE DAGKFILL GRADE S LOPE 6 :... ...... ...... 20' 4' PERFORATED
342.E ...... LOAMY DAGKFILL --� 6EOTEXTILE PVC PIPE
TED DANDIN6 5TRAPh UNIT
...... .. 4' IN-DRAIN
I co GLEAN SAND PERFORATED
'4— I PVG PIPE
31' MAX
/. . . . . . ... raw . . . .
/
TD :41 6 MIN —
j GLEAN MED-GOARSE
(iMhON'h) SAND
52 Lwi V 24'
30" ,Y MIN TO GWT, ROCK
STUMP OR IMPERVIOUS 5TRATUM
EMDANKMENT SOIL PERG RATE - 12 MIN / IN >2' 12'
GIN Ila
14' PVC ,
• I . :-. �. ... .. a DECK '• ,
2i MIN ., SECTION
1 I
45 �•. SINGLE IN - [)FAIN UNIT
.I FIN GRAD ''•�342.E ' —
•••,,, " 5
L005E LAID IN DRAIN ADc,) OFFTION BED NT
STONE WALL
W. H 0 U � NTh OF C�UEBNSBURY
N TOWN
101
BUILDING ~ D EP'T.
. EXPOSED REV161NGC 8Y ....�•
0 Q LEDGE [)ATE
O
24" -~ c ,�
N S TUMP 70 TOWN O. QUEEN,,W BMW DEr,fRTMEItiT
. � 4 PVG � �our on out knited e�nents snail
o ESGHED 4o HYDFAULIG ELEVATIONc,) nat�C L _
p
-SEPTIC I G TANK ..' in ful
plans and sped at ions are
.... �� compliance with the cede
TANK � I1/EC)
5EPTIG TANK INV IN 342.55 5ET DEAD LEVEL JUN 14 2000
TOw�
5EPTIG TANK INV OUT 342.30 ON 12, GR, KOGK BJILplti�` EEf4SSURY
Q 'aNC�CO►)E 2000405 18 . ,1-20
PHILLIPS ROB R
� T & DONNA
015T 60X INV IN 341.60 DITTO ABOVE 147 PILOT KNOB RD.
SEPTIC ALTERATION
v 0 D15T DOX INV OUT 341.35 ALLOW 3' DROP
LEDGE
(0 'IN-DRAIN' LAT INV 341.10 LAY DEAD LEVEL
ROBERT and DONNA PHILLIPS
14
WASTEWATER DISPOSAL SYSTEM
MAPLE '
o LA 147 PILOT KNOB ROAD P.O. KATTSKILL BAY 12844
l l
QUEENSBURY, NEW YORK 12$04
TAX MAP # 18-1-20
S I T E FLAN • • • •
���•. SCALE: AS SHOWN DATE: JUNE 2000
5GALE. 1 10 . w.
SCUDDER ASSOCIATES
: P.O. BOX 792
GLENS FALLS, NY 12801
GHARLE5 H. hGUDDER TEL 518 / 793-1473 FAX 518 / 798-3747
FE 40904
email: cscudeeglobal2000.net
SHEET 1
'IN-DRAIN' A155 SYSTEM
LOWER STAIR
10 0' S E T B A C K 100' SETBACK TREAD EDGE DECK
350 'IN-DRAIN'
QUEENSBURY ORDINANCE
5Y5TEM THE QUEEN515URY SANITARY 5EWA6E D151`05AL ORDINANCE GOVERNS
................... .
348
'""" "" "'"" " ..."""" " DESIGN AND GON5TRUGTION OF THE PROP05ED WASTEWATER 5Y5TEM.
348
344 ........ ... ................. ................. ................. 4� ......I............ ...........I...... .... ...... .................. ..... .......I. .................. ................... ..........I......
3
344 344
PIPING, FADKIG and FILL- MATERIALS
........... ..................................................... .. ........ ........... .....I.... ...............I... ...................
342 FIN GR 342.6 342 FIN GR 346,6. 015TRIBUTION LATERAL5 5HAL.L BE 4 DIAMETER PERFORATED PVC WITH
.. ® EXI TING GRA E ® EXISTIN GRADE MINIMUM 3,000-POUND CRUSHING STRENGTH.
...............................
.... . .......
340 340 BUILDING DRAIN5 TO 5EPTIG TANKS, AND EFFLUENT LINES TO D15T. BOX
................... .......... ....... ... ..... .... ................... ................... ................... ......I.,.......... ................ ... ......... ........ ................... ................... ..........I........ .
SHALL BE 5GHEDUI-E 40 PVG WITH TIGHT JOINTS.
338 338 WALL
""'"....... "" """".""""" ""'""" ........."""""' """""""""' """""'"."'.. CONCRETE SAND MEETING NY5DOT 5PEGIFIGATION 703-07 SHALL BE
336
................... ................... .................. ................. ................. ................... .................. 336
.................
................... .....••.•... ...... ..... ... ........ ..................• ................... .......... ........ ................... PLAGED BELOW AND AROUND 'IN-DRAIN' UNITS A5 5HOWN IN THE DETAILS.
EMBANKMENT 501L 5HAL - BE SANDY-LOAM WITH AN AB50RPTRION RATE,
334 334
AFTER COMPACTION, OF APPROXIMATELY 12 MINUTE5 PER INCH.
.............. ....... . ..... ................. ..... ....... ........... ........... .. ................. ................. ................. .............. ....... ................. ................. ................. GEOTEXTILE SHALL BE SOE 'MIR '
................... ................... .................. ................. ................. .............I... ................. ... ...I............. ................. ................. AFI 140N WOVEN FABRIG.
332 332
................... ................... ................... ................... ................... ................... ................... ................... ................... ................... ................... ................... ................... ................... ................... ...................
330 330
DE516N 1)15GHAR6AE
O 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
DESIGN DI5GHAR6E (5-BR HOME- POST lggl FIXTURES) 15 550 GPO,
5 E G T I O N A - A '�E G T I O N D-D PROVIDE 24 'IN-DRAIN' UNITS - q6 LF.
H 1' - 10'
H 1' - 51
V 1' - 5'
V 1' -
EL-GEN 'IN-DRAIN' SYSTEM
.2EPTIG T 15 5 AL ENTRANCE THE 'IN-DRAIN' ELJEN 5Y5TEM, NOW APPROVED BY NY5DOH, 15
TANK AT 5. WALL HOUSE PRORIETARY. INSTALL ACCORDING TO MANUFACTURER'S DIRECTIONS.
'IN-DRAIN' AB5 SYSTEM 'IN-DRAIN' EXPOSED
AB5 5Y5TEM LEDGE ELGEN TYPE-D UNITS MEASURE 36' x 48' x 7'. CONNECT 5Y5TEM
100' 5ETBAGK UNITS IN ACCORD WITH DIREGTION5 OF ELJEN CORP., 15 WE5TWOOD
EXIST ROAD, 5TORR5, GT 06268.
EDGE DECK 100' SETBAGK MIN DECK BLDG
HEIGHT SEWER
348 ................. ................. .... ....... ........ ...... ................. .............. ................. ................. 348 ................. ................. ......... ....... .... ..... ...... .... .......... ........ ..... .................
SEPTIC TANKS 4 D15TR18UTION 80X
3,44 ............... I.................. . ..... ....... ........ ...... ................. ............... ................. ................. .................
344 344 .... FIN GR 342.6 344
ONE 1,000-6AL, AND ONE 500-GAL 5EPTIG TANK ARE REQUIRED.
.... TOP 342.E
LOGATE 5EPTIG TANKS ACCORDING TO 51TE GONDITION5 AND
342 EXISTING GRADE 342 S.T. INV OUT 342.3 - `` .... . OWNER'S REQUIREMENTS. AN AL-TE41ZNATE 15 5HOWN ON THE PLAN.
..WALL.......... ........... ....... ® ® ................... ................... ................... ................... ..... DIST LAT INV 341.1
34
"" IT 15 PERMISSIBLE TO PLAGE TANKS UNDER THE DECK 51NGE NO
--�" "" ••••• i500 GALLON FOUNDATION WALL EXISTS.
340 340 .............. ...... 5EPTIG TANK
= NOTE THAT 5EPTIG TANK ODORS GAN BE A CONTINUING NUI5ANGE.
338 338 �(/QLL 338................................... "................. ADEQUATE VENTING AND VENTILATION MUST BE INCORPORATED IN
THE PLAGEMENT AND PIPING OF THE ENTIRE 5Y5TEM. CONTRACTOR
................... ....... ........... . . ..... ........ ................... ................... ................... ...................
'IN-DRAIN' BEYOND - SHALL COORDINATE WITH OWNER AND ENGINEER REGARDING ODOR
336 336 GONTROL AND 5Y5TEM VENTING AND VENTILATION.
334 334
SET 5EPTIG TANK UNITS LEVEL ON A 12' BED OF GRU5HED ROCK.
EXISTING GRADE
............... ................... ................... ................... ................... ................... ................... ................... PROVIDE ADJUSTABLE OUTLETS ON THE D15TKIBUTION BOX.
................... ................... ................... ................... ................... ................... ................... ................... ................... ................... ................... ................... ................... ................... ................... ...................
332 ................... ................... ................... ................... ................... ................... ................... ................... 332
.................. ................... ................... ................... ................... ................... ................... ................... PROVIDE A DISTRIBUTION BOX WITH FOUR OUTLETS ON ONE SIDE.
.............. ................... ................... ................... ................... ................... ................... ................... ................... ................... ................... ................... ...................
330 330 1 1 1 APPROVED FIBERGLA5 5EPTIG -TANKS MAY BE 5UB5TITUTED FOR
PREGAST CONCRETE GA5TIN65 AT OWNER'S D15GRETION AFTER
GON51)LTATION WITH CONTRACTOR AND DESIGN ENGINEER,
O 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
SEGTION G - G SEGTION D -D
H 1' - 10' H 1' - 10'
V 1' - 5' V 1' - 5'
INDI6ENOU5 �$ FILL_ 501L.5
STABILIZED PERGOLATION TEST RATE - 12 MIN/INGH.
SOIL TE5T5 PERFORMED BY GHARLE5 H. 5GUDDER, PE,
50IL5 IN THE ABSORPTION AREA WILL BE DENSE 5ANDY/LOAM.
4 'Z 6 24 ,
NOTE
PARTIGULAR 51TE GONDITION5 MAY 5UG6E5T 50ME MINOR
CHANGE OR ADJUSTMENT IN SYSTEM GOMPONENT5.
� l
�- ANY 516NIFIGANT DEPARTURES FROM THE APPROVED PLANS
N MUST BE AGGEPTABLE TO THE TOWN OF QUEEN5BURY, THE
OWNER AND THE ENGINEER. ROBERT and DONNA PHILLIPS
Or
WASTEWATER DISPOSAL SYSTEM
26, 26 '
147 PILOT KNOB ROAD P.O. KATTSKILL BAY 12844
QUEENSBURY, NEW YORK 12804
TYPICAL 3' x 4' x 7' 'IN-DRAIN' UNIT
24 UNITS REQUIRED TAX MAP # 18-1-20
SCALE. AS SHOWN DATE. JUNE 2000
LAYOUT .•''� •. '
SCUDDER ASSOCIATES
°IN - DRAIN " AD50KTI0N SYSTEM P.O. sax 792
NT15 �. 40904 '�' GLENS FALLS, NY 12801
•'' �wh TSL 518 / 793-1475 FAX 518 / 798-3747
GHARLE5 H. 5GUDDER
PE 40904 email: cscnds0global2000.net
SHEET 2