Loading...
SEP-0445-2021 SEPTIC DISPOSAL PERMIT office Use Only ft, -- APPLICATION Permit#: �z-&- QZA4 5-&21 Town ofQoeensbury Permit Fee:$ �rD Invoice#: 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 vrtvvr.queensbury.net Flood Zone? Y N Reviewed By. Project Location: 11 LUPINE LANE Tax Map M 302.17-1-16 RESIDENCE INFORMATION: Year Built Gallons #of bedrooms: X gallons per =total daily flow per day bedroom Garbage Grinder Yes No 1980 or older 150 Installed? (choose one) X 1991-1991 130 Spa or Not Tub Yes No 1992-Present 110 4 110 440 Installed? (choose one) X PARCEL INFORMATION: Topography ✓ Flat Rolling Steep Slope % Slope Soil Nature Sand Loam Clay Other,�explain: Groundwater At what depth? GREATER THAN 6 FT Bedrock/Impervious material At what depth? GREATER THAN 6 FT Domestic Water Supply . : :: Municipal Well Lake (if well or lake, water supply from any septic system absorption is ft.) Percolation Test Rate: 1-sMIN per minute per inch (test to be completed by a licensed engineer/architect) PROPOSED SYSTEM INFORMATION: Tank size 1250 gallons (min. size 1,000 gallons, add 250.gallons.fo.r each garbage cylinder or spa/hot tub EXISTING 1000 GAL CONCRETE System Absorption field w/#2 stone Total length ft.; Each Trench ft. Seepage Pit w/#3 stone How many: ; Size: Alternative System Bed or other type:20 FT X 30 FT Holding Tank System Total required capacity? ; tank size ; #of tanks Septic Application Revised January.2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN ENTAIL • Applicant: Name(s): HANK BROWN Mailing Address, C/S/Z: 11 LUPINE LANE. QUEENSBURY,NY 12804 Cell Phone: Land Line: Email: • Primary Owner(s): Name(s): SAME AS APPLICANT Mailing Address, C/S/Z: Cell Phone: Land Line: Email: Check if all work will be performed by property owner only • Contractor: Contact Name(s):SANITARY SEWER SERVICES Contractor Trade: Mailing Address, C/S/Z:LUZERNE RD, QUEENSBURY Cell Phone: Land Line:518-796-3760 Email: "Workers' Comp documentation must be submitted with this application* • Eneineer(s): Name(s): CENTER PROJECT SERVICES Mailing Address, C/S/Z:73 SHERIDAN STREET, GLENS FALLS NY 12801 D l, C E 0 V E Cell Phone: Land Line: Email: JUN 0 9 2021 Contact Person for Compliance in regards to this project:GEORGE DRELL S TOWN OF QUEENSBURY Cell Phone: Land Line: 518-796-3760 BUILDING &CODES Email: !VOTES: 1. Alarm system and associated electrical work roust be inspected by a Town approved electrical inspection agency; 2. We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. 3. As- built drawings must be submitted prior to the inspection, if there has been a change to the submitted plans.4. If, for any reason,the building permit application is withdrawn, 30% of the fee is retained by the Town of Queensbury. After 1 year from the initial application date, 100% of the fee is retained. Declaration: Any permit or approval granted which is based upon or is.granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Dispo*00rdii e. PRINT NAME:GEORGE SIGNATURE: DATE: Septic Application Revised January 2021 e TOWN OF QUEENSBURY � BUILDING DEPARTMENT Based on our limited examination,compliance with our comments shall not be conshf4 as o indicating the plans and specifications a„0 full compliance with the Building Codes of New York State. TTOWN OF . QUEENSBU�y .BUILDING & CODES_ ODES QE� s d Reviewed y; �' i ► Date: N 1 L y � t a t a: a Lcn co W o H G 4 0c� MmH �' co Oo FILE cop y CD 73 Sheridan Street, Glens Falls,NY 12801 Phone-518-796-2515 June 8,2021 Project#343 George Drellos Sanitary Sewer Service ITOWN C EpEQueensbury,NY 12804Re: Proposed Replacement Septic JUN 0 9 2021 11 Lupine Lane, Queensbury,NY OF QUEENSBURYLDING&CODES Dear George: At your request, we have reviewed your proposed replacement septic system design of the existing 4-bedroom house at 11 Lupine Lane in Queensbury. As per our conversation the residence has an existing failed septic system. We have reviewed the proposed replacement septic system design and we agree that a standard absorption bed is acceptable.Based upon a design flow rate of 440 GPD and a percolation rate.of 1 to 5 minutes,you will need a minimum of 489 sf of absorption area. We recommend using 20 ft wide by 30 ft long absorption bed with 4 —25 ft long laterals. The absorption system can be constructed with the new 1,250-gallon septic tank, new distribution box, and 4-inch diameter perforated pipe and stone. Please feel free to contact me at 796-2515 if you have any questions and that you for your assistance with this request. Sincerely, Thomas R. Center Jr.P.E. ` 57 of • E C � V E 172 021 i JUN O TO�U1 DI G&-�OD`=S Vol =------ ` ` E .-- ,��" AS BUILT L12s 9 f, . L ii 1 i