Loading...
2006-023 7z7(-1.1r-- TOWN OF QUEENSBURY 742 Ba Road ueensb NY 12804-5902 518 761-8201 Y ,Q �Y, � ) Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20060023 Date Issued: Monday, July 01, 2013 This is to certify that work requested to be done as shown by Permit Number P20060023 has been completed. Location: 131 SEELYE Rd Tax Map Number: 523400-227-017-0001-054-000-0000 Owner: . YVONNE M KONIOWKA Applicant: YVONNE KONIOWKA This structure may be occupied as a: Residential Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property 4 owner of the responsibility for compliance with Site Plan,Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. 1 TOWN OF QUEENSBURY RIE C 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 ola-,0 0-3 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: P20060023 Application Number: A20060023 Tax Map No: 523400-227-017-0001-054-000-0000 Permission is hereby granted to: YVONNE KONIOWKA For property located at 131 SEELYE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: YVONNE M KONIOWKA Residential Alteration $50,000.00 EDWARD KONIOWKA'KIMBERLY Total Value 7670 SHELDON Rd $50,000.00 WHITEMORE MI 48189-0000 Contractor or Builder's Name/Address Electrical Inspection Agency 101) Plans&Specifications 2006-023 Paid$100 to renew permit for 2 years(pd. on Jan 23, 2012) Residential Alteration: 100 sq. ft. first floor stair addition, finish basement 1,040 sq. ft. $114.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,February 06,2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town Qf j-ee sbury Monday,February 06,2006 df SIGNED BY at" 47 K r for the Town of Queensbury. Director of Building&Code Enforcement • • • • • OFFICE USE ONLY RECEIVED' • • TAX MAP NO. a'-)U17_(^ 5-11 PERMIT NO. 0j� ,—O)-3 BAN 2 0 FEES: PERMIT l 1 '' RECREATION ENGINEERING TOWN �oo6 I • i' (If applicable) Ul G%#R CrOoDE PRINCIPAL STRUCTURE: • APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED-BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FORA CONSTRUCTION. • APPLICANT/BUILDER: P2' .. die E%3MAOWNER: SAM 4 ADDRESS:,&N/112-I LLr 3_,I}+f 1(2J )? ADDRESS: PHONE NOS. sd 4 447 I 1425 PHONE NOS. CONTACT PERSON'FOR BUILDING & CODES COMPLIANCE: -463647) ' LOCATION OF PROPERTY: ) I Lam/ gp,y SUBDIVISION NAME: - PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT APPLY TO YOUR z 0 C3 . d wo i • PROJECT g00 ' O • 0 I— LLI o w � w � LL w ¢ a,, U ,Z < < - co NQ) 0uu o � • O oa SINGLE FAMILY a7• KIbatp— V V {2tI' t,040' Ie urdT f7f- TWO-FAMILY /Ho S e • MULTI-FAMILY (NO.of UNITS ) • • • TOWNHOUSE BUSINESS OFFICE • RETAIL- MERCANTILE FACTORY OR INDUSTRIAL • .ATTACHED • - GARAGE(1,2,3) j OTHER IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: O Please complete a separate Application r for''Fuel Burning Appliances&Chimneys' HOW MANY FIREPLACE(S): �� .AND/OR WOODSTOVES(S): availabl in our office ZONING CATEGORY: 1VR- I ARE THERE WETLANDS ON THIS SITE? f40 IS THIS A HISTORIC SITE? L10 - rr/� PROPOSED USE OF BUILDING OR ADDITION: BUhit-4 4`l4. p,•a- B 3-LGL 11-05 .Town of Queenshury• Community Development Office • 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? No ARE THERE EASEMENTS ON PROPERTY? / Z) I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes,local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior-to occupying the facilities proposed, I or my agents_will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built surveyy a licensed land_.surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have rea agr to tr a abov . Signe7. Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule,an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: • BUILDIN CO S APPROVAL ZONING APPROVAL • • DAT , DATE QUESTIONS? CALL 761-8256 OR EMAIL codesftueensbury.net VISIT OUR WEBSITE FOR MORE INFORMATION www.queensburv.net :?tti 7A Towrt of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 OFFICE USE ONLY , ', , ECEI WED • `da7•1-7-1-Sit- PERMIT NO 4"'(Y) PERMIT FEE ; 'r • • JAN ." 1006 , TAX MAP NO. , O , APPROVALS: ZONING TOWN CLERK ; tOWN OF QUttN6BURY APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT.OWNER: Mike�1 ' ' ' ,./A ,INSTALLER: ADDRESS: AN/ P 124 L Wie44 J4Y/24 DDRESS: • PHONE NOS. PHONE NOS. LOCATION OF INSTALLATION: , L ,1 .., Kt)) (/fir)I—ZV le...:1> '� IA - RESIDENCE INFORMATION: NO.OF i = 1 TOTAL DAILY FLOW YEAR BUILT I X I COMPUTATION= BEDROOMS ; GARBAGE GRINDER 1980 or older 1 X 150 gallon per bedroom i - INSTALLED? 1981 -1991 I X 130 gallon per bedroom ? = SPA OR HOT TUB I 1992-present 1 X 110 gallon per bedroom i = INSTALLED? p ��•; PARCEL INFORMATION: 1CA.JTL> Fa L T71 I I4J4�_ ✓ TOPOGRAPHY: FLAT ROLLING STEEP SLOPE %SLOPE ✓ SOIL NATURE: SAND LOAM CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? BEDROCK/IMPERVIOUS MAT -F L`AT_ WHAT DEPTH? ;'-'7 Aolot rill C. ✓ DOMESTIC WATER SUPLY: MUNICIPAL WELL • (IF WELL:WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS FT. ) g I- ✓ PERCOLATION TEST: RATE IS PER MIINUTEP-R INCH (TEST TO BE OCP � COMPLETED BY A LICENSED PROFESSIONAL ENGINEEP t\ITECT) PROPOSED SYSTEM FOR NEW CONSTRUCTi rsal systems must'be designed by a licensed professional engineer or architectJi- {ivy" ; \approved subdivision).Add 250 gallons tb the size of the septic tank an-"� // t^ 5 '; i1 whirlpool tub. ✓ SEPTIC TANK: vl !/_ D: EACH TRENCHFT. a\A\ . ✓ TOTAL SYSTEM LENGTF \ W �,', - Y? • ,� 1 ✓ SIZE OF EACH Fl, jJjj-1AsiC \L\f- \() e)0411\r\ 1 ✓ SIZE OF STONE TO BE USE \k(7. WO ✓ BED SYSTEM SIZE: k(/1\A ,' , ✓ ALTERNATIVE SYSTEM: \\.!\' �\ \\N.kJ \ -� ✓ HOLDING TANK SYSTEM:(If req\ � �O EACH ✓ GALLONS.!TOTAL CAPACITY:_ f\, , NOTE: ALARM SYSTEM AND ASSOCIATi _L:CCTRICAL WORK MUST BE INSPECTED BY A TOWN :l :I APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. II For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. , I have read the regulations with respect to this application and. agree . -bide by these and all requirements'of the Town of QUESTIONS? CALL 761-8256 OR EMAIL Et.eensbu Sa ewage D:=po.al Ordin-nce. codes@queensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION r 6www:queensburv.net Sig attire-of Person Responsible D. e -Ore j Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection re uest received: Queensbury Building & Code Enforcement Arrive: t( f am/pm pepart: am/p 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: ]�/ (O 1Z) NAME: -Mot-) PERMIT #: 6 ' 72 5 LOCATION: ` Gy6� INSPECT ON: ' TYPE OF STRUCTURE: \ Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum C eanout every 100 feet/ change of direction ressure Test Drain ent Air ea. 5 F.S.I. or :0 ft. above highest connection for 15 minutes Press est / /Water Supply Piping / ,, / PelilDi Air/ Head v �(/ey 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check Proper Vent, Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape - COMMENTS: L:\Pam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 . _ Co - Foundation Inspection Report Office No.(518).761-8256 Date Ins cii s• v•r es received: Queensbury Building&Code Enforcement Arrive" 1 / .m/ _ _ Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: ./O/1/ /� PERMIT#: (0' ' 3 LOCATION: /3/ y rrLre A . INSPECT ON: 9S^ O4, TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing - for 48 hours following the placement of the concrete. . Materials for this purpose on site. • Foundation/Wallpour Reinforcement in Place Foundation Dampproofmg Foundation/Waterproofing Type of Dampproofmg/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 .1 poly for wet areas under slab B ckfill Approval '_umbing Under Slab PVC Cast/Copper 4 h n / r • oundation Insulation Interior/E tenor R- Irough Grade 6 inch drop within 10 ft. /#1,-*/Ge6i 7/ � — r ( i ) Foundation Inspection Report Office No. (518)761-8256 Date In tior1)equest received: Queensbury Building&Code Enforcement Arrive:, am/p.m, Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector s Initials: �v�/ NAME: +\(Jo\(-$1\ Ni u,--\ PERMIT#: Sly r O'93 LOCATION: 1 S c4. Q C�INSPECT ON: TYPE OF STRUCTURE: l � 6-0��� Comments Y N N/A ootings — Piers !!! Monolithic Slab Reinforcement in Place 2, The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval • Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM • Framing/ Firestopping Inspection Report Office No.(518)761-8256 Date Ins do lequest received: Queensbury Building&Code Enforcement Arrive p art: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: �%' `" • NAME: SNsapA()\-- r\ 1 rM PERMIT#: 3 LOCATION: ) ' INSPECT ON: -__ TYPE OF STRUCTURE: Y N/A COMMENTS ramrng ele��' " Attic Access 22"x 30"minimum Jack Studs/Headers O`—1 Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. • Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 Y2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2,3 hour i Fire wall 2, 3,4 hour / o P ng 17LC 1 Penetration seale --p s—r -4-d 16 inch insulation in cavity min. 4estc.- ---r-r A-re&I-5 Garage Fire Separation House side Y2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms ) 24 in. (H) °(< f d /A3SV I..— 20 in. (W) 5.7 sf above/below grade 5.0 sf grade r v/fiZ 9 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: ani/p �'epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials_ NAME: `C Ck- \ k j0. c\ PERMIT #: )0n( -O3 LOCATION: 13-1 ,\ � E INSPECT ON: ©S--c 2 —0 TYPE OF STRUCTURE: Y N N/A /' 6 0/ PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm, Plumbing Vent I Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head Air Supply Test rain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial I Cooper,CPVC,Pex One and Two-Family l Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 thdA 1c-=1-z• Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspect'gn 'AA-quest received: Queensbury Building & Code Enforcement Arrive: • 1I am/p a art: am/pm 742 Bay Road, Queensbury, NY 12804 Inspectors I itials: NAME: D/d4 PERMIT #: LOCATION: ��G j"C �� INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping 1i6-/ Head 0 P.S.I for 15 minutes su n f l esidential Check/ Commercial Check Proper Vent, Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace uct work sealed properly / No duct tape COMMENTS: L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 rk-iiimr__, ,,, s . Queensbury Builds ` & Code Enforcement - Residential Final Inspection Office o. (518)761-8256 Arrive: us- am/pm . Depart: am/pm Date Inspection request received: Inspector's Initials: C - NAME: foil_t i . L� k r• PERMIT#: Oi —02 3 LOCATION: � _ DATE: TYPE OF STRUCTURE: _ ` w Comments:1 Yes No NIA 4" Building Number Address visible from road ,_ • Cp 2 —6 /0 Chimney Height I"B"Vent/Direct Vent Location ---rl�"� l Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade ■ Guard at stairwell at 34 inches or more Guard at deck,porches 36 Inches or more ■ ■ Handrail Termination at Newell Post or Wall- Interior/Exterior Railings 34 inches to 38 inches , all x-Derm,IL ' q4 _- Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet s I A /J x6 inch clearance to sill plate /ti,, ie, Gas Valve shut-off exposed/re,ulator 18 inches above •rade IIIII� Interior privacy 1 trim I doors/main entrance 36 inches f416( Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors I Carbon Monoxide Detectors —(6 i•e4Every level: Every Bedroom: (j c C���[ Outside every bedroom area: • ,, ,�, Inter Connected: _ Battery backup: ___ • 5-c l�eitJ/- /6 151e` /— Attic access 30 inches x 22 inches x 30 inches hei•ht in accessible area Crawl Spaces 18 inch x 24 inch access, I sq.ft:150 sq.ft.vents III ■ , r.M/'1 Bathroom Fans,if no window ilia Plumbing fixtures II Foundation insulation/Insulation Certification G i (Aza Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler MN Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%"GypsumI Basement stairs closed rise>4 inches Garage Floor Pitched 1111� Garage fireproofing/3/4 hour fire door/door.closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical MN Final Survey Plot Plan Ii Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System I Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required WARM Okay to issue C I C or C/0[Temporary/Permanent] 1 L:\Building&Codes FormstBuilding&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08 5 . kk--tiC" Queensbury Build! ' .& Code Enforcement - Residential Final Inspection Office NO (518) 761-8256 Arrive: 9S am/pm . Depart: am/pm Date Inspection request re4ceived: Inspector's Initials: - NAME: _6j 0 I.,, !�� PERMIT#: 06\ -023 LOCATION: _ DATE: TYPE OF STRUCTURE: Aor��j ,r • Comments: Yes No N/A � 4" Building Number Address visible from road 2 _6 / Chimney Height/"Jr Vent/Direct Vent Location ` Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall - Interior/Exterior Railings 34 inches to 38 inches ,� `rrl P - Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet. /� % 6 inch clearance to sill plate t' A,d -) ply Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy I trim/doors/main entrance 36 inches if Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazi Interior Smoke Detectors I Carbon Monoxide Detectors �0 cat Every level' Every Bedroom: Outside every bedroom area: • Inter Connected: Battery backup: • SC,I ®a/4— Attic access 30 inches x 22 inches x 30 inches(height'in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft:150 sq.ft.vents. I prM71 Bathroom Fans,if no window - r p44 Plumbing fixtures Foundation insulation I Insulation Certification - 4'j U+✓'o,frf Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade ' Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'"Gypsum Basement stairs closed rise>4 inches . Garage Floor Pitched Garage fireproofing/%hour fire door/door.closer Duct work Sealed proper Gas Logs in Sealed or Glass Enclosure Final Electrical . Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required - Okay to issue C I C or C I 0[Temporary/Permanent] L:\Building&Codes Formsleuilding&Codes\lnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08 J . Queensbury Building.& Code Enforcement - Residential Final Inspection • Office No. (518)761-8256 Arrive: am/p Depart: am/pm Date Inspection request received: Inspector's Initials: _�� f NAME: KOYI ��➢ �� PERMIT#: LOCATION: DATE: TYPE OF STRUCTURE: _ Comments: Xpil No NIA 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location y s� r Fresh Air Intake 4 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers r r� Guards at stairs,decks,patios more than 30 inches above grade w ! ,he sefrd. Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim 1 doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: _ • Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation I Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/.hour fire door/door.doser ► Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/SewerDept. Inspection Sticker Site Plan I Variance required Flood Plain Certification,if required Okay to issue C I C or C I 0[Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc;Revised January 7,2008;Revised 6/26/08 \,: Queensbury Building & Code Enforcement - Residential Final Inspection Office No. 518 ( )761-8256 Arrive: ?r' am/1; D�e ,art: am/pm Date Inspection request received: Inspector's Initials: • NAME: LJ/��'� C?/� 1 OP l/J k0 -- PERMIT#: — O2� LOCATION: /3 J 02/ DATE: % / p)7 TYPE OF STRUCTURE: / rThe Al Comments Yes No N/A Z Building Number/Address visible from road k7 Chimney Height/"B"Vent/Direct Vent Location �� Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade /J�� Guard at stairwell at 34 inches or more £'ok k°12-filt i lle Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails a@ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches 6,0te— ('�F F !O Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing 011/a .G—�kL!/ etP Interior Smoke Detectors: Every level: Every Bedroom: L�j�C�� �1� Outside every bedroom area: ; j/0 it) 1-6CC..c 5-- Inter Connected: Battery backup: , v r Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30.inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''/2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent] L:1Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc Queensbury Building & Code Enforcement - Residential Final Innspe�o`r /� Office No. (518)761-8256 Arrive: am/p Depart: l s 3 /pm Date Inspection request received: Inspector's Initials: NAME: /'<4 n f i Cil(C PERMIT#: ) `' 3 LOCATION: c i Reli DATE: TYPE OF STRUCTURE: rs s -¢ ]—�-- Comments: Yes No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inchea.or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors!main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors!Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/hour fire door/door closer in led or Glass Enclosure inal Electrica• nergy Saving Light Bulbs 50% -Fina73urvey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required / Flood Plain Certification, if required Okay to issue C/C or C/O[Temporary/Permanent] L:\Building&Codes Forms1Building&Codeslinspection Forms1Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12/22/10,Revised 04/13/11 is it tus o a�. Queensbury-Building & Code Enforcement.- Residential Final inspec ion Once No. (518)761-8256 Arrive: am/p ; De•art:".) am/pm Date Inspection request received: Inspector's Initials: NAME: `Nbitine Xi? rx) OLOK PERMIT#: 0(0-C� 3 LOCATION: 1 S � e. fl G✓ Pci DATE: TYPE OF STRUCTURE: Comments: Yes No NIA 4" Building Number Address visible from road • �\M t7q 1-o€a Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches ^3 � ',w Roof Complete/Exterior Finish Complete / R� p�� `"f�\r U Platform at all exterior doors Handrail 4 or more risers (,.,a0(J Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall / • Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-offexposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight • Safety glazing/Window in stairwells safet r_glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access,1 sq.ft:150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 • Enclosed Stairs Sheetrock Underside minimum%:"Gypsum Basement stairs closed rise>4 inches rrL Garage Floor Pitched Garage fireproofing/a/4 hour fire door/door closer 72-4 0 Gas Logs in Sealed or Glass Enclosure Final Electrical; /o -- .;\31 3_- Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof.Receptacles Flex Gas Pipe Bonding As BuiltSeptic System/Sewer Dept. Inspection Sticker ���` � Site Plan /Variance required Flood Plain Certification,if required Okay to issue Cl C or Cl 0[Temporary 1 Permanent] L:\Building&Codes Forms1Building&Codesllnspection Fomts\Residential Final Inspection Form revised_100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12/22/10,Revised 04/13/11 • Q`Vr l � FRibAkle - —06 / Framing/ Firestoppin Ins ection Report Office No.(518)761-8256 Date -ction request received: Queensbury Building&Code Enforcement Arrive / am/ epart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspect '§ni ials:.�� NAME: bEDIA ,J , PERMIT#: LOCATION: /3( � rz_ �f�► INSPECT ON: �p TYPE OF STRUCTURE: Y N N/A Framing COMMENTS s 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams • Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed i. 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) . . 20 in.(W) 5.7 sf above/below grade . 5.0 sf grade Foundation Inspection Report Office No.(518)761-8256 Date Inspection -a .- �y'v • 0 Queensbury Building&Code Enforcement Arrive: r ,:.- 1p s „doll- .art: pm 742 Bay Rd.,Queensbury,.NY 12804 Inspector's Iniflj NAME: 1 D h tRMIT#: 6 -6- 3 LOCATION: 3/ INSPECT ON: TYPE OF STRUCTURE: 696\-- Comments Y N N/A Footings Piers Monolithic Slab "fr(P1°F(/' Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: ✓ jy-� ' �� 12 inch width 6 inches above footing 6 mil of for wet areas under slab -11ackfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation 19sulation Interior xteri R- 1-b' k\I),"�DA Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Reportdoc Last printed 12/20/2005 9:24:00 AM Foundation Iln Report Office No.(518)761-8256 Dgtio quest received: Ct/ S i° Queensbury Building&Code Enforcement Are min b Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 In Initials: UV-it./ �Z NAME: )I ") PERMIT#: 0 / (/` -J LOCATION: 13 ( <e p / e 0 MKT_ INSPECT ON: _- M TYPE OF STRUCTURE: Comments Y j N/A ` /Footings �� Piers Monolithic Slab (1 Reinforcement in Place f The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. _ Materials for this purpose on site. Foundation/Wallpour enforcement in Place / , Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Fts\Foundation Inspection Report•doc Last printed 12/20/2005 9:24:00 AM fr„-r ,, • _ _ - ' • • ‘•. .. . . . • • • • • • Framing/ Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: 3!(v am/pm Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: � hJ- NAME: /0i PERMIT#: °+� LOCATION: /,3 j C &- INSPECT ON: TYPE OF STRUCTURE: Y N /N/A Framing COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers ' Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. _ Je Su i'"-T � Headroom 6 ft. 8 in. • Stairwells 36 in. or more Fiec/s C�.4-1J J Headroom 6 ft. 8 in. d co •is � Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate � �/ .cr6yp r"ijll 1 '/ (w) 16 gauge(8) 16D nails each side , _ Draft stopping 1,000 sq.ft. floor trusses !.3 L6sdW Anchor Bolts"6 ft. or less on center Ice and water shield 24 inches from wall " Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. is Garage Fire Separation House side 'A inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade • • r A rl' pp Community Development Office -�� 1 . SPA . • JAN 17:14 ozorr of Queensburi/ • 742 Bari Road • QtreensburV, New Fork •1280 , E. . _'tlarils/n Ryba, Executive Director• Dar.ld Hatin, Director of Building& Codes TOWN OF QUttN�BUR • Craig Brown, Zoning Administrator BUII DING AND CODE • • BUILDING PERMIT CALCULATION SHEET: • . NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS . REQUIRED .ACTUAL • • ACTUAL LIGHT REQUIRED. SQUARE FOOT • HABITABLE ROOM AREA OF ROOM IN LIGHT SQUARE VENTILATION-4°i° VENTILATION 'OPENING FOR REMARKS SQUARE FEET 8"•OF ROOM AREA • FOOTAGE OF_ROOMAREA SQUARE EGRESS FOOTAGE A91 Ro,k)We-X. - 12�� IS ' .11-.94) 3, '5. . 742, 7 I Ills rSE r.2 14dc 11,20 . J, 5_ S,6 6, 6, 75 . 1 4t N 4* tGA Yrr e _ QUESTIONS? CALL 761-8256 OR EMAIL - ' • ti codes(a QueensburV.net • VISIT OUR WEBSITE FOR MORE INFORMATION www.gGensburv.net - B 10-LTR 11-20 4r Community Development Office ,. r4s own of Queensbury • 742 Bay Road • Queensbury, New York •12804 Marilyn Ryba, Executive Director• David Hatin, Director of Building&Codes Craig Brown,Zoning Administrator WINDOW SCHEDULE JOB SITE/ADDRESS: 1 l gA 1./Leyr.. ATE: OWNER: M A{ l=, ,o, 4 e APPLICATION NO.: UNIT OR CLEAR WINDOW- CLEAR WINDOW STOCK ROUGH ROUGH SQ.FT. OPENING NO.OR WINDOW SQ.FT. OPENING SPECIAL HARDWARE OR MANUFACTURER NUMBER OPENING OPENING EGRESS/CLEAR HEIGHT LETTER MODEL/TYPE VENT WIDTH IN INSTRUCTIONS ON PLAN NAME CALL WIDTH HEIGHT OPENING INCHES IN SIZE INCHES 1-4,oNtlt 20444, 2e0116 56 74, 5;1 S 74 24).4 lexANN c'sazsch-1 tr-1 1.4.m 61...2 •31"12' Ya 0 0 0 76.\\ x4) 1 4,Ltr›E2 AG3 72" 2ci 7e. ' • A la Sod C u r›E. C 45 On e..e)u 7.6z —7, 6,zZp g 3Z L {t 1 .. & 401 2.14 Z.4- j3tib I ( / i 400 c„_O a.3 Permit# Permit Date Generated by REScheck-Web Software Compliance Certificate Report Date:01/21/06 Energy Code: New York State Energy Conservation Construction Code ' Location: Washington County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 9% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: Coriipli-ance?Passes - Maximum UA:71 . " Your Home UA:64-->9.9%Better Than Code(UA) Gross Cavity Cont. Glazing UA Assembly Area or R-Value R-Value or Door Perimeter U-Factor Cathedral at entry stair:Cathedral: 104 19.0 0.0 5 Wall 1:Wood Frame,16in.o.c.: 420 19.0 8.0 16 Window 1:Wood Frame,2 Pane w/Low-E: 38 0.330 13 Door 1:Solid: 20 0.400 8 Floorl:Unheated Slab-On-Grade:,Insulation Depth:3.0' 30 8.0 22 Furnace 1:Forced Hot Air(Non-Electric):78 AFUE The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Builder/Designer Company Name Date Project Notes: Stair enclosure/entry addition to existing residence 131 Seelye Road Cleverdale,NY Page 1 of 4 . i . ._ .. . . . . . . , . . . .. . , . . . . . . , . , . ,. .' . . . - .. • . . ."', . - . . ., . • . . . .. . . . . , . . . . . . , . . . . - . . . . . . • . . . . . . .i' . . , . . . . „„ .. , , ., . . . , • . - .. I . . . • , • . . . . • ,.. . . . , , , • . . .'•". . - . _ . . - ... . ,, ..• .." , , , . • . . . . . . . - ..... ., , .,. . . ,. . . . ., . . • , ., ... , .. ,, , ..... ..T.. . . .. . . . . .... . . . . ., . • .. . . . . . , , Generated by RESchec%Web Software Inspection Checklist Date:01/21/06 Ceilings: - ❑ Cathedral at entry stair:Cathedral,R-19.0 cavity insulation Comments: Above-Grade Walls: - ❑Wall 1:Wood Frame,16in.o,c.,R-19.0 cavity+R-8.0 continuous insulation Comments: Windows: ❑ Window 1:Wood Frame,2 Pane w/Low-E,U-factor:0.330 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: - Doors: ❑ Door 1:Solid,U-factor:0.400 Comments: Floors: ❑ Flood:Unheated Slab-On-Grade,3.0'Insulation depth,R-8.0 continuous insulation Comments: Slab insulation to extend down from the top of the slab to at least 3.0 ft.OR down to at least the bottom of the slab then horizontally fora total distance of 3.0 ft. Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade) insulation and extends at least 6 in.below grade. Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from Insulation. Vapor Retarder: - Required on the warm-in-winter side of all non-vented framed ceilings,walls,and-floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturers installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-11. ❑ Return ducts in unconditioned attics or outside the building must be Insulated to R-6. ❑ Supply ducts in unconditioned spaces must be insulated to R-11. ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. .Insulation is not required on return ducts in basements. Duct Construction: Page2of4 a .. i_ .. _ . ._ ..,�r • • .. :c • ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels In Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. • • • Page 3 of 4 O .y C Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness In Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) • Page 4 of 4