Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2003-347
TOWN OF QUEENSBURY j742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20030347 Date Issued: Wednesday,:August 20, 2003 This is to.certify-.that work requested to be done as shown by Permit Number P20030347 has been completed..' Tax Map Number: = _ 523400-239-020-0001-007=000-0000 Location: 2966 STATE ROUTE 9L Owner: JOSEPH & CYNTHIA DIDIO Applicant: JOSEPH'& CYNTHIA DIDIO This structure may be occupied as a: By Order of Town Board Deck TOWN OF QUEENSBURY 44P1 Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20030347 Application Number: A20030347 Tax Map No: 523400-239-020-0001-007-000-0000 Permission is hereby granted to: JOSEPH& CYNTHIA DTDTO For property located at: 2966 STATE ROUTE 9L in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JOSEPH& CYNTHIA DIDIO 120 OAK St Deck $10,000.00 Total Value $10,000.00 HUDSON FALLS,NY 12839-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2003-347 441 SQ FT LOWER DECK AND 184 SQ FT UPPER DECK AS PER PLOT PLAN SPECIFICATIONS $62.50 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,June 04,2004 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To ueensb ; W dnesday,June 04,2003 SIGNED BY C/..)41Yf(�r for the Town of Queensbury. Director of Building ode ZIti forcement Por:ch,:.Deck, Dock, or Boathouse Permit Application - • _ Town of Queensbury-Dept of Community Development, 742 Bay Road, Queerisbury,NY (518)761=8256 A permit must be obtained before beginning construction. No Permit File No. '- Irt7 inspection will be made until applicant has received a valid Fee Paid $ • building permit. All applicants'spaces on this application must be Reviewed By: 1 �' completed and must appear on the application form. j� j/ Applicant: ``�%�c5��h-l C((c.) Owner: Y4 4f e. Address: 296 gr79- i2— ' L Address: 647c �jr�o2Gf /1 //Z r Phone#(S-/b-) (ram lam- 96797 Phone#( ) - Email Address: ✓bec i co dek v-c-i4o4e / Email Address: kii Person Responsible for Supervision of Work as Regards to Building Codes: Name �W/M �co v,.a Address: ;F}riG/ 1J 80, Phone 792--76707 Property Location: Lot Number; / House Number (29Wrl �L Subdivision Name: - Tax Map Number: oZ 39,a 6-/-7 Estimated Market Value of Construction: $ /0 --(2 00 0 ❑ Porch Deck ❑ Dock ❑ Boathouse SAY 2 9 200 u Other work(describe cj'c// cowe,g.' TOW NG AND CODE Size of structure to be built square feet /8L1(//✓p6v1— /?>:t�r e nveti%ai= �j�is77' `' Submit along with this application: • 1. Two plot plans drawn to scale,preferably using a survey map. Indicate proposed structure showing setback dimensions from all property lines. Show location of water supply and location and configuration of septic disposal area. 2. Two sets of structural drawings.. Indicate size of posts or studs, floor joists, decking or flooring material to be used. Show how the porch or deck will be fastened to the building. If a roof will be constructed, indicate the size of posts or studs,roof rafter spacing and span. Indicate type of roof: sloped,flat,shed,or other. Indicate the type of material being used for the roof. Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,-are a true and complete statement of all proposed work to be done on the described premises and that all provisions . .o- •'t +•de;the Zoning Ordinance and all other laws pertaining to the propose' work shall be om•Ff: - th,/ ether specified or noted,and that such work is authorized by the owner. A licant s si ature: - /r Date: Z( 0-3PP A L:4SueHemingway`Building.Permit.FORMS'Porch.Porch,Permit.doc 8/13/02 revised per DH 17/ Residential Final Inspection • . Office No. (518)761-8256 Date.Inspecti n request received: • . Queensbury Building&Code Enforcement Arrive: SW am/„), Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: .NAME: !cam►Ci PERMIT#: T LOCATION: DATE: 3 TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof, Roof Complete , Guard 30 in. or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing . Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches _ 3 hour fire door/door closer Garage fireproofing Duct work Sealed properly Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq.ft.-150 sq. ft.vents Building No./Address visible from road Final Electrical . Site Plan /Variance required • Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification,if required Okay to issue C/C(Cert.Of Compliance) Okay to issue Temporary C/0(Cert.Of Occupancy) Okay to issue Permanent C/0(Cert. Of Occupancy) L:\SueHemingway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc'edited January 28,2003 Residential Final Inspection . Office No. (518)761-8256 Date Inspeption request received: Queensbury Building&Code Enforcement Arrive: /1 26 am/pm Depart: am/pm 742 Bay Rd., Queensbury,NY 12404 Inspector's Initials: ( �1,� • NAME: PERMIT#: CX0 3-- 59-7 LOCATION: c DATE: TYPE OF STRUCTURE: �� Comments Y N N/A • Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake Re QkCjc 3 inch Plumb Vent through roof Roof Complete Guard 30 in. or more @ stairs,decks,patios Guard at stairwell at 34 in.or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. ,..),Coe �`�wze� wdJ° Platform at all exterior doors Interior Handrails stairs 2 or more risers • (Ci/ Cat Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall Y if 8 inch clearance to sill plate • Gas Valve shut-off exposed/regulator 18"above grade • Gas Furnace shut-off within 30.ft. or within.line of site • Oil Furnace shut-off at entrance to furnace area • Furnace/Hot Water Heater operating •Low water shut-off boiler • . Relief Valve(s)installed .• Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing • Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping fmished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches _ %hour fire door/door closer Garage fireproofing Duct work Sealed properly Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq. ft.-150 sq.ft.vents Building No./Address visible from road Final Electrical . • Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification,if required Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C/0(Cert. Of Occupancy) Okay to issue Permanent C/0(Cert. Of Occupancy) L:\SueHemingway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003 ._----� Residential Final Inspection • 4 3 1,/ . Office No. (518) 761-8256 Date Inspection request received: �6 a Queensbury Building&Code Enforcement Arrive: „lam am/pm Depart: am/pm 742 Bay Rd aueensbury,NY 12804 Inspector's Initials: NAME: 410•'L L b PERMIT#: ca2 737 LOCATION -a L® DATE: b 3 TYPE OF S 'UCTURE: 964S.- - Columents Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake ` r !J"r 1L 4 544— 3 inch PlumbtVent through roof d`� Roof Complete Guard 30 in. or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete / Interior/Exterior Railings 34 in.to 38 in. ' , a,If' iv4- 3 d/� ,4- (Pt--- Platform at all exterior doors Interior Handrails stairs 2 or more risers Nee ace /0 Grade away from foundation 6 in.with 10 ft. /� Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site • Oil Furnace shut-off at entrance to furnace area • Furnace/Hot Water Heater operating Low water shut-off boiler • Relief Valve(s)installed • Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing • Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping fmished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches . 3/4 hour fire door/door closer Garage fireproofing . Duct work Sealed properly Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq.ft.-150 sq.ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker • Flood Plain Certification, if required Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C/0(Cert. Of Occupancy) Okay to issue Permanent C/0(Cert. Of Occupancy) L:\SueHemingway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003 Residential Final Inspection \ ' D 6 Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: /O y(am/ Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: : Q \ PERMIT#: 3 _3q 7 LOCATION: a (b�p SZ�� __ DATE: TYPE OF STRUCTURE: Comments x N N/A Chimney Ht./"B"Vent/Direct Vent Location Lod / � i�weioe41 Fresh Air Intake L 3 inch Plumb Vent through roof Roof Complete Guard 30 in.or more @stairs,decks,patios ,4// Secs 6... rrJ Guard at stairwell at 34 in.or moreAl If at deck,porches 36 in. or more '� I3�v�� �� ®re V Exterior Finish Complete // / Interior/Exterior Railings 34 in.to 38 in. /� ��`� n���f �� 8�z�it�� Platform at all exterior doors �/ * H �,Live /e�Us Interior Handrails stairs 2 or more risers 3 c-/•—3J b Grade away from foundation 6 in. with 10 ft. �f Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade as LIMP- AT," Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area "ue Furnace/Hot Water Heater operating •Low water shut-off boiler // •Relief Valve(s)installed • r �� er �4" q tea Interior privacy/trim/doors/main entrance 36 in. `°� G� sty• Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping fmished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches 3/4 hour fire door I door closer Garage fireproofing • Duct work Sealed proper Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area • Crawl Spaces 18"x 24"access, 1 sq,ft.-150 sq.ft.vents Building No./Address visible from road Final Electrical • Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification,if required Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C/0(Cert. Of Occupancy) Okay to issue Permanent C/0(Cert. Of Occupancy) L:\SueHemingway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003 Foundation Inspection Report Office No. (51E)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: (L-id am/ Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector s Initials: �r NAME: � (� ,�(J�-/ PERMIT#: LOCATION: - C ( ?� �� T J INSPECT Old. /--� -- TYPE OF STRUOZ , f Comments N N/A ootings drr(�1.11 Piers .4„em,),, pier- ',G✓ "' • Monolithic Slab Reinforcement in Place an cp cr,ss5 -Seev64., . The contractor is responsible for • providing protection from freezing • for 48 hours following the placement of the concrete. Materials for this purpose on site. • Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab • Bacicfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 `20t 2003 12:26 5167478239 BOLSTER LAND SURVEYcR627.3 .:64.7 . .PAGE 02 41:64.. ,#,* AVID J. BOLSTER se vc - LICENSED LAND SURVEYOR 51:8•747.8747 FAX 518.747.8239 • Mr Joe Didio . t it/ t ji Lake George, N. Y. 12845 . t 00 p 0Py • R;., average tut vlidti; Dear-Joe . Oas :d on the information furnished to us mainly a reap entitled "t'lot Plan made for Gilbert O. & Wilma C.. .Boehm" dated November 22, 1977 and-prepared by John L . Va.nDusen, LS, the average lot Kndlii of v ur parcel of land located'between the easterly shore of Lake George and Rt. 9L. is 40.17 feet. fhe'-- C-drStance`tif 971-71eet]s a computed_distance_that_is— p lietriar.to-vt:iritortit and sctut!i 1!e.'The north tool _.. ti__.-----, south lines are parallel lines. If you have any questions please feel free to call us. _ Sin• rely 1t l •• gpi,f- . l d.�LC .. DAVJI . OLSTER, IS • • 342 MAIN STREET, IIt1I)SON FALLS, N.Y. 12839 • • - W1� .1�� 1 , 1 . will 1. . . A PQt1 *,0 .. ift, • . . • _ -_ -- . -,!-- :,---,-/.- ' ,m. ,.‘. \k . . �, . fr , ,,,J. alas 21 y '4:, r . /�/ 1 ��a+ s 2t�\ti ► 1 v . . \ . , ,ji J�"03, �, \ \ . �. �-.- 6 , --)1616° (Y."- - ) _ . „) 7)01Ati . . . l '60 facvq __. Z.,172----E.'0 . . , . . i _............... 1,... ...... . . . • . l • !.. . 11/ c•4 t• ; . • -, , ."\ . 1) IF ( 441 • I c://41 f,,,,, ,,.' : :: I j1 -�I c•, ► LA 1 C illaii......5 I N • 5', 1 _ _ - N ty • 0 yj��i;ppia�e,p, aA�- t -fig� 9GadWm, I . Y_], _ - , //�� �e �y ,+• ilii_._._, ., . ...i. \ �5llll�_^"1 '.R!6Ce •6 f i_� • ; w Ta d, � ' ( / 7 M 7 ,i VI �6. 9t .,r_ , aF- A ;S./,,,1..,......:14*.... .:.‘:,. ..,. ..: ' '..2.,ii. . ‘1 11 . ''''.....''... =-''''''' .. -t4ir 4- il, ,,, 6...., . .,_,‘,.-4,- .,......„, , . E 0 4 Nii 1 1 , , • ,t,Z •59 . 0 ,1 i ' Gi .. I . t t SR P DecY, Pu1135 FLOOR PLAN / •G-O / . 1 i 1 j I lG . a . F - . I ' I.. , c{ • 1 , I • 2 X G RAP_ CAP . . I i 1 H + II � 4X4PO5TLINDER \ ' - ! , + - FON- START T :.1.0 1O -�� START POINT'' ' 2 - 6' DECK 5CAR75 ' I !ACM TREAD _ 6.-0. 4, 4.-0' I I G.-0. 12 X 1G DECK PLAN SCALE. 1/4' = 1'-0' - STEP #1 FOUNDATION PLAN STEP #2 FLOOR FRAME -DctmRle b2CYN \ ick.Y1S . 16--0' / / ,�\�\\\��\\\\\�\� \,x,s,,'�G SIALDNG\\��\\�\\\\ (\\\\\\\\\\\\\�\\\` S;tvG BLNLDING\\\\\\\\\\�\\\\ \ 13+ — x I I; • iIs x - ( ( !i I r I 2 X 8 P.T. SPACER 4- LINE OF DECK ABOVE ? II\ BLOCK 4 1/2' LONG © !I a N _ AT 16' O.G_ iI ?l x PREDRILL FOR 2 - 2X1OP.T. n aI ° I i; ' �: N LAG BOLTS O BULD UP GRDER In II %BELOW I ;� ° 1 2 - 2 X 30 P.T_ O 1 N ! `� BUILT UP GRDER ° 1 O a ?� I BELOW 1 4 X 4 P.T. POST 1 GI I $ 4 ON 8'11 CONCRETE III a I# I I Z X 8 P.T. FE_LED SONO TUBES j� x + I SPACER BLOCK nl a I! I III ALL - PURPOSE • .32-I., n .-. 1 Gs--\ in 11 r-TI__' _) `I HANGERS `-� ( i'� II I I I 4X4P.T. POST 1 ( I. 1? i Co I 1 I II c mo_ x'' ! 11 �; !t _oi 1 --. \ 1', II II I START PONT t FCONCR.ETE O �Y © it _ IG \ - START PONT IPAD 1I 3 - 2 X 1 P.1. 11 II U/ STREiG_RS �i .1 -A - 25 JOIST O\ • \ l$ L _ _ 3' HANGERS i 1 t 31 5' -4' 4"-0 �-- / 5'-6' il, 5"-0' 4, 5"-6" 16' -O', q / . 12 X 1G DECK FOUNDATION PLAN 12 X 1G DECK FRAMING PL AN SCALE. 1/4' = 1'-0' SCALE. 1/4- T-O- Or • STEP #5 STAIRS EXISTING EXTERIOR--- ` 6' Sr.EATr�Ic !� P 2 X 6 —� /. t TT. GAP 6 RAL SIDyG G EXTERIOR I! RAR. GAP II K EXISTING K-- 2 X 4 I III I INSULATION 2 X 4 4 2 X 2 BALUSTER I IJJG `! I '4X4 ! (` AT 6' O_G. FLA !� PARTION F �J 1 2 X 2 i9 'TER 1 2X10PT. i I AT 65 0.C. LAC BOLT I EXISTIIG HEADER • 2' l = PREDRILL ' i 6- DEGi�IG EXISTIIc • I f1 II I I 1 I . i LOORAIG 2 X 4 I I ill C.1-- I f E -2X4 ,� 111 li • •_ �_ J ! � _ 2 X 8 P.T. r I I : }� STLHG JOIST I I�� • I ;� II I 2 X 8 PS_JOIST 16' O_ . EX STAG 6" DECKING W O !/ Lr. --ALL PURPOSE HANGER _� yillj C2� 2 X 6 INSTALL W/ • SPACE OF 10P 2 X 8 P.T. S SLL NAIL BETWEEN JOIST < N METAL JOIST �� METAL JGST EAGM HOARD PURPOSE > / MANGERS A - 2 !!1 , rIANG S A - 25 AL - , METAL JOIST JOIST MANGERS is, / MANGER �'�I cTc 2 X H PS.MANGERS A - 25 , 2 - 2 X 10 -� SPACER HLOGKI cc 5ULT 'I 4 1/2' LONG SEC I ION B 4 --..\ > F4 P.T. POSANGLT r r � ,�� .� - 2 X 10 P.T. 4 X 4 P.T. POST I LAG BOLTS R SCALE. 3/4'y1"-0" STeZL^IG_R • r POST ANG'iOR I I , 1 y OUNDATICN -- ~_-^ �,�� �,��� I I `� GALVAhLZE7 METAL�''//\\//�//� • GRADE `aI 4 :_3 -'r' = \\,\�/� ; GUSSET AT SPLICES \///\�/\'/.I \j�s� � lam`:... _ :?,;/ ALL rURPOSE ANGLE- / OVER POSTS C Nd� \% a %\\/\\. ---M: r.^ /�� AND lSiG`tOR BOLT 4.1 Q 4 ca 0 /\�z — CONC. PAD TO ca O 3 u Wit- ?y H=LOW FROST 8" CONCRETE - - v O LINE FILED 5CN0 TUNE -' JO __: a p . / Is 4T AT 12' VARIES 3'-0' I 4'-O' I G - SECTION A SCALE. 3/4'=1'-0"