Signed Inspection Report (06-29-2021) (9).pdfINSPECTION WORKSHEET (POOL-011616-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:POOL-0175-2020 Case Module:Permit
Inspection Date:Tue Jun 29, 2021 Inspection Status:Passed
Inspector:Dyer, Charles Inspection Type:Pool
Job Address:Parcel Number:39 NORTHWOOD DR
Lake George, NY, 12845
288.16-1-5.1
Contact Type Company Name Name
Applicant Haverly, Colleen
Contractor Concord Pools and Spas
Primary Owner Haverly, Colleen
Granted Permission Haverly, Colleen
Checklist Item Status
Building Inspector Notes Passed
10/27/20 observed pool is covered for winter season, permanent fence installed. Pool must be inspected by TOQ
code enforcement prior to use. Please call 518-761-8207 to verify you have received this notice and possibly set
time and date prior to 2021 use of pool. 5/14/21 reminder that pool must be inspected prior to use by TOQ code
enforcement. Please call number listed to set time and date. Thank you
Pool inspected 6/21/21
ÿþ NA
Pool enclosure around pool or yard Passed
4 feet above grade Passed
2 inch max to grade from underside of fence Passed
Jun 29, 2021 Page (1)
INSPECTION WORKSHEET (POOL-011616-2021)
Checklist Item Status
Self closing device or alarms (30 sec Alarm time)Passed
Provide alarm on door
Verified 6/29/21
Pool Surface Motion Alarm Passed
Ladder secured in place and latched Passed
In ground
Gate opens outward, self closing Passed
Padlock provided on gates or ladder Passed
Timer on pool pump (no plug in timer allowed)Passed
Suction outlt must be protected agst user entrpmnt - (eff 5/12/2020)Passed
Bottom pool drain vacuum relief system-REQUIRED Passed
Final Electrical Passed
Ok to issue CC Passed
Jun 29, 2021 Page (2)
Dyer, Charles