Loading...
SEP-0482-2021 SEPTIC DISPOSAL PERMIT office use Only 4t APPLICATION Permit#: �'0 2' 2 'Z-1 Town ofQueensbury Permit Fee:$ _ Invoice#: � It 2__ 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.gueensbury.net Flood Zone? Y No Reviewed By_-j� Project Location: 28 STEPHANIE LANE D 0 W E. Tax Map #: 308.12-2-66 JUN 24 2021 -TOWN OF-QUEENSBURY RESIDENCE INFORMATION: BUILDING&CODES Year Built Gallons #of bedrooms: X gallons per =total daily flow per day bedroom Garbage Grinder Yes No 1980 or older 150 Installed? (choose one) X 1981-1991 130 Spa or Hot Tub Yes -No 1992-Present 110 4 110 440 Installed? (choose one) X PARCEL INFORMATION: Topography _ �/ Flat Rolling Steep Slope % Slope Soil Nature Sand` : Loam Clay Y Other;-explain: Groundwater At what depth? GREATER THAN 6 FT Bedrock/Impervious material At,what depth? GREATER THAN 6-FT Domestic Water Supply Municipal Well Lake (if well or lake, water supply from any septic system absorption is Percolation Test Rate: 9-5MIN per minute per inch (test to be completed by a licensed engineer/architect) PROPOSED SYSTEM INFORMATION: Tank size 1250 . gallons (min. size 1,000 gallons, add 250 gallons.for each garbage cylinder or spa/hot tub EXISTING 1250 GAL CONCRETE System Absorption field w/#2 stone -Total length ft.; EachJrench ft. Seepage Pit`w/#3 stone How many: Size: Alternative System Bed or other type:20 FT X 30 FT Holding Tank System Total required capacity? ; tank size ; # of tanks Septic Application Revised January 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s):JOHN BEAUDETTE Mailing Address, C/S/Z: 28 STEPHANIE LANE. QUEENSBURY,NY 12804 Cell Phone: Land Line:. Email: • Primary Owner(s): Name(s): SAME AS APPLICANT Mailing Address, C/S/Z: Cell Phone: Land Line: Email: Check if all work will be performed by property owner only - - -- - - • Contractor: Contact Name(s):SANITARY SEWER SERVICES Contractor Trade: Mailing Address, C/S/Z:LUZERNE RE), QUEENSBURY Cell Phone: Land Line:-518-796-3760 - Email: "Workers' Comp documentation must be submitted with this application" • Eneineer(s)• Name(s),-'CENTER PROJECT SERVICES Mailing Address, C/S/Z:73 SHERIDAN STREET, GLENS FALLS NY 12801 Cell Phone: Land Line: Email: Contact Person for Compliance in regards to this project:GEORGE DRELLOS Cell Phone: Land Line: 518-796-37601. Email: NOTES:I..Alarm-system-and-associated electrical work must be inspected by a Town approved electrical inspection agency; 2. We will no longer allow systems to be covered until such time as an as-built plan is received and approved.The installed system must match the septic layout on file—no exceptions. 3. As- built drawings must be submitted prior to the inspection, if there has been a change to-the submitted plans. 4. If, for any reason, the building permit application is withdrawn, 30% of the fee is retained by the Town of Queensbury. After 1 year from the initial application date, 100%of the fee is retained. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and a ree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinan PRINT NAME:GEORGE DRELL SIGNATURE: DATE: Lfj� � Septic Application Revised January 2021 TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY. 12804-5902 Septic System Checklist tV Plan to scale 1--Received Deep hole perc test results from engineer/Architect if applicable(Town Approved Engineers and Architects;June 30 to April 15 Town Engineer for unapproved Engineers and Architects) Ab All wells on property and adjacent properties shown tqLWater line shown Municipal or well 10'separation to any part of system Setback to property lines show 10'or more for any part of system ASeptic tank and pump stations 10'from foundation 50'from any well/lake/wetland 10'from any waterline MA-Septic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank for 0',Separation required (field verification required) VI�Septic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each -` K Leech Field 20.'from foundation 100'from any well 10'from water line NIASeepage pit 150'from well 50'from septic tank tIASeepage Pits 3-times diameter apart �Iq Septic tank and pump stations over 30 gallons 50'from watercourse or wetland 14A- distance from bottom of trench or system 24"to bedrock or mottling 36"within 1000'of Lake George IALeech field 100'from watercourse or wetland r'UT Toe of mound or bottom of retaining wall 10'from property line 100'from well 20'from Foundation MProvide Engineer/Architect stamp for bed or design systems Department of Health Approval for all mobile home park new systems Flood Plain requirements kk 'vy 2' above established flood elevation to bottom of system WAll tanks anchored or 2' above flood elevation CENTER PROJECT , SERVICES 73 Sheridan Street, Glens Falls,NY 12801 Phone-518-796-2515 TOWN OF QUEENSBURY June 22,2021 BUILDING Based on our limited DEPARTMENTexamination,compliance Project#346 with our comments shall not be construed as George Drellos indicating the plans and specifications are in SanitarySewer Service full compliance with the Building Codes of ' New York State. Queensbury,NY 12804 Re: Proposed Replacement Septic 28 Stephanie Lane, Queensbury,NY Dear George: At your request, we have reviewed your proposed replacement septic system design of the existing 4-bedroom house at 28 Stephanie Lane in Queensbury. As per our conversation the residence has an existing failed septic system. We have reviewed the proposed replacement septic system design and we agree that a standard absorption bed is acceptable. Based upon a design flow rate of 440 GPD and a percolation rate of 1 to 5 minutes, you will need a minimum of 488 sf of absorption area. We recommend using 20 ft wide by 30 ft long absorption bed with 4 —25 ft long laterals. The absorption system can be constructed with the existing 1,250-gallon septic tank,new distribution box, and 4-inch diameter perforated pipe and stone. Please feel free to contact me at 796-2515 if you have any questions and that you for your assistance with this request. Sincerel , TOWN OF QUEENSBURY BUILDING & COWEPT. Reviewed Date. Thomas R. Center Jr, P.E. EEE E021 NSBURYODES 308.12-2-66 SEP-0482-2021 Beaudette, John 28 Stephanie Ln Residential Septic Alteration JUN 2 4 2021 TOWN OF GUirL-NSBURY BUILDING CODES � aid ,..,....�..- �3 �..- �a�-^�...^""<^•�- � Cam" I V..-��. � ECE VE � Zs, JUL 08 2021 S WN OF UEENSBV s ...., ,._. BUILDING&CODES t �