Signed Inspection Report (07-20-2021) (8).pdfINSPECTION WORKSHEET (RESFINAL-012070-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0255-2020 Case Module:Permit
Inspection Date:Tue Jul 20, 2021 Inspection Status:Partial Pass
Inspector:Dyer, Charles Inspection Type:Residential Final Inspection
Job Address:Parcel Number:12 HALL RD EXT
Queensbury, NY, 12804
289.11-1-17
Contact Type Company Name Name
Applicant Leonardo, Adam
Engineer VanDeLoo, Walter
Granted Permission Rosewood Home Builders
Contractor Rosewood Home Builders
Applicant Leonardo, Rebecca
Primary Owner Leonardo, Adam
Primary Owner Leonardo, Rebecca
Checklist Item Status
General Comments Failed
CO in Bedrooms w/Gas NA
4 inch Building Number Address visible from road Failed
Chimney Height / B Vent / Direct Vent Location Failed
Jul 20, 2021 Page (1)
INSPECTION WORKSHEET (RESFINAL-012070-2021)
Checklist Item Status
Chimney Rain Cap Installed Failed
Fresh Air Intake Passed
Fresh air supply 3' from grade Passed
3" Plumbing Vent through roof minimum 18 inch Passed
Outside Spigots have Air Gap Passed
Roof Complete / Exterior Finish Complete Passed
Platform at all exterior doors Passed
Handrail 4 or more risers Passed
Guards at stairs,decks,patios 30" + above grade Passed
Guard at stairwell at 34" or more Passed
Window guards req:<2' above floor/6' above grade - quick release installed Passed
Guard at deck, porches 36" or more Passed
Jul 20, 2021 Page (2)
INSPECTION WORKSHEET (RESFINAL-012070-2021)
Checklist Item Status
Handrail Termination at Newell Post or Wall Passed
Interior/Exterior Railings 34 to 38 Passed
Wood deck: 2'+ from grade dia bracing required - H/C ramp compliant Passed
4+ Deck Joist Ledger Connections-24" From Ends Passed
Deck Ledger-Bolted per Code Failed
Grade away from foundation: 6" down, 10' out Passed
6" clearance to sill plate Passed
Gas Shut-off Exposed & Regulator (18) Above Grade Failed
HVAC Vent Terminal 10' from Lot Line & Openings Failed
Dryer Duct Max Length 35', Labeled Over 35'Failed
Interior privacy/trim/doors/main entrance 36 Passed
Jul 20, 2021 Page (3)
INSPECTION WORKSHEET (RESFINAL-012070-2021)
Checklist Item Status
Bathroom / Kitchen Watertight Passed
Low flow toilet 1.3 gal/flushing cycle - showerhead/faucet Passed
Safety glazing: w/in 5' of tub/shower - stairwell win/adj to drs NA
Smoke Detectors:Passed
CO in Bedrooms w/Gas Failed
Smoke Detectors 3' from Kitchens & Baths R314 Passed
Every level, Every bedroom Passed
Outside every bedroom area Passed
Battery backup: _____Passed
Inter Connected Passed
Carbon Monoxide Detectors:Passed
CO Detectors within 10' of all sleeping areas Passed
Jul 20, 2021 Page (4)
INSPECTION WORKSHEET (RESFINAL-012070-2021)
Checklist Item Status
Attic Access 22 x 30 minimum NA
Attic Access Insulation = Attic R- Value NA
Attic Access Gasketed NA
Foam in basement/attics covered w/thermal barrier Passed
Crawl Space Access 18 x 24 Failed
Bathroom Fans, if no window Passed
Plumbing fixtures Passed
Backflow Preventors where required Passed
Foundation insulation to floor Passed
Energy Sticker on Elec. Panel:R-Val. & Heating Sys Passed
All Hot Water Systems: 3/4" or larger piping R-3 Passed
Jul 20, 2021 Page (5)
INSPECTION WORKSHEET (RESFINAL-012070-2021)
Checklist Item Status
Duct work sealed properly Passed
Intake Openings Passed
Range Hood 400+ cfm-Fresh Air REQUIRED Failed
Blower Door Test Certification Passed
HRV or ERV Installed per Bedroom Requirements Passed
Floor truss, draft stop- fin base 1,000 sq. ft.Failed
Emergency egress below grade Passed
Furnace shut-off w/in 30 ft. or w/in line of site Passed
Oil Furnace Shut-Off at Entrance to Furnace Area Failed
Propane Tank: Proper Setback from Prop Line/Struct Passed
Furnace/Hot Water Heater operating Passed
Low water shut-off boiler Failed
Jul 20, 2021 Page (6)
INSPECTION WORKSHEET (RESFINAL-012070-2021)
Checklist Item Status
Relief Valve ,Heat Trap/Water Temp 110 deg or less Failed
Provide relief valve
Encl. Stairs Sheetrock Underside minimum ½ Gypsum Failed
1/2" Gypsum or House Wall and Gable Failed
5/8" Type X with Living Space Above Failed
20 Minute Fire Door/Self-Closing Hardware Failed
Seals on Garage Doors, esp. Wood Failed
Basement stairs closed rise greater than 4 inches Passed
Basement Egress: 5s.f. window w/sill or Bilco door Passed
Basement ceiling covered 2x8 fl joist or less Failed
Jack posts in basement lagged at top and bottom Passed
Fireblocking at fl joist 80 s.f. or less Failed
Jul 20, 2021 Page (7)
INSPECTION WORKSHEET (RESFINAL-012070-2021)
Checklist Item Status
Garage Floor Pitched Failed
1/2" Gypsum-Bsmt Ceiling<2x10 Frame/TJI/Fl. Truss Failed
Gas Log In Sealed or Glass Enclosure Passed
Fin Elect; Energy Saving Light Bulbs 50 Percent Failed
Provide final electrical
CSST/other piping in conduit if buried,if required Failed
Final Survey Plot Plan Passed
Arc Fault Breaker Habitable Spaces Passed
Flex Gas Pipe Bonding Failed
As Built Septic System Passed
Sewer Dept. Inspection Sticker Failed
Site Plan / Variance required Passed
Flood Plain Certification, if required NA
Jul 20, 2021 Page (8)
INSPECTION WORKSHEET (RESFINAL-012070-2021)
Checklist Item Status
Fuel Tanks above flood plain elevation NA
Truss ID Signage Installed at Electrical Meter NA
Stick frame
OK to Issue C/O Passed
Jul 20, 2021 Page (9)
Dyer, Charles