Signed Inspection Report (07-22-2021) (26).pdfINSPECTION WORKSHEET (POOL-012221-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:POOL-0387-2020 Case Module:Permit
Inspection Date:Thu Jul 22, 2021 Inspection Status:Partial Pass
Inspector:Dyer, Charles Inspection Type:Pool
Job Address:Parcel Number:36 COTTAGE HILL RD
Queensbury, NY, 12804
301.12-3-3
Contact Type Company Name Name
Applicant JACKSON, TRISH
Granted Permission JACKSON, TRISH
Primary Owner JACKSON, TRISH
Checklist Item Status
Building Inspector Notes Failed
Pool must be inspected by TOQ code enforcement
Please call 518-761-8207 to confirm.
The above ground pool must be inspected by TOQ code enforcement, please call 518-761-8207 to set time and
date, please comply within 5 days of this notice, avoid court summons. 7/22/21
While in vehicle printing out report, homeowner came out and we proceeded to go over pool inspection.
Everything was verified with the exception of motion alarm. Trish hopes to have in place by 7/23/21 and will call
when it's in place for verification. 7/22/21
ÿþ NA
Pool enclosure around pool or yard Passed
Above ground pool at 54"+
4 feet above grade Passed
2 inch max to grade from underside of fence NA
Jul 22, 2021 Page (1)
INSPECTION WORKSHEET (POOL-012221-2021)
Checklist Item Status
4 inch maximum clearance in fence pickets NA
Maximum spacing of wire fence 1 3/4"NA
Self closing device or alarms (30 sec Alarm time)NA
Pool Surface Motion Alarm Failed
Must provide
Ladder secured in place and latched Passed
Gate less than 56 to latch ½ max spac in openings NA
Gate opens outward, self closing NA
Padlock provided on gates or ladder Passed
Must provide
Timer on pool pump (no plug in timer allowed)Passed
Must provide
At panel box in house
Bottom pool drain vacuum relief system-REQUIRED Passed
Final Electrical Passed
Jul 22, 2021 Page (2)
INSPECTION WORKSHEET (POOL-012221-2021)
Checklist Item Status
Must provide
Vehicle access gate closed & locked NA
Ok to issue CC Failed
Provide pool motion alarm
Jul 22, 2021 Page (3)
Dyer, Charles