Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2004-807
TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes ,(518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20040807 Date Issued: Monday, July 25, 2005 This is to certify that work requested to be done as shown by Permit Number P20040807 has been completed. Tax Map Number: 523400-301-018-0002-024-000-0000 Location: 5 TIMMONS Ln Owner: JOHN &LYNN SCHULZ Applicant: JOHN & LYNN SCHULZ This structure may be occupied as a: Residential Addition By order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040807 Application Number. A20040807 Tax Map No: 523400-301-018-0002-024-000-0000 Permission is hereby granted to: JOHN & LYNN SC;Hi LZ For property located at: 5 TIM 40NS Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tempe of Construction Value Owner Address: JOHN &LYNN SCHULZ 5 TIMMONS Ln Residential Addition $19,000.00 Total Value $19,000.00 QUEENSBURY,NY 12804-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2004-807 600 SQ FT RESIDENTIAL ADDITION (MASTER BEDROOM) $75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday,November 02,2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T4 of eens u�fy;�J �e a ovember 02, 2004 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement `A Building Per it'Application Town of Queensbury—Dept of Community Development,742 Bay Road,Quedasbury,NY (518�761.8256 A permit must be obtained before beginning construction. Permit File No. 011—c4117 No ispection will be made until applicant has received a Fqe paid $ valid building permit. All applicants' spaces on this Ree.Fee Paid application mustbe completed and must appear on the Reviewed By: applidation form. Applicant: 7010 7"Mv Owner: So H N S cat k Z \` Address: F K, r mArz Address: r M NOW UJ�/h l� q0�ZKJCtect,ft/ /0✓ Phone#(6`2 '6/ -,-e=i,. Phone#( ) HIECEIVEI Property 1.,00ntiow. Lot Number:, , / House Number,�/ ovU 61� ((;Qua OCT 0 8 20 04 SubdivisionNsme: Tax Map Number: -30 1,1 r a �N OF QUEENSPUR UiLDIfdO AND CODE o New Building: residence /commercial 'Estimated Market Value of Construction: $ C °U Addition: residence/ commercial If an Addition,w t''11 us of riCW addition be? o Alteration: residence/ commercial [SAS i���e�Jt�, I,*'% C No change to exterior size: residence/com'1 o Otherwark(describe ) Check pccupancyTnformation 1 Floor 2 Floor Ot Moor Total 13010w sq.ft, sq.ft, aq.ft. ,nn quare Feet Sin e farrlil dwelling ) " o Two famil dwelling / o Towmouse o Multifk=4 dwellin #of units o Office /� - o Mer =dle i I A) . o Msaufhaivtiit o l oar ddached e 0 2 oar detached ffaso 0 3 oat detached garage o l car attached M90 a 2 car attached 8=20 0 3 ear attached garage e a Storage building- U oommemial © Storage building• ' residential o Other What is the proposed height of the structure, feet inches Will any s000nd-head or ungraded lumber be used? Tf so,for what?_ L2 — Typo of Heating System: electric/ oil / gas/wood (forced hot air/ baseboard/other: ,_,,,,_ Number of Flreulaces to be in tailed Number of FSS&t=to be installed a�L List below the person(s)responsible for supervision of work as regards to building codes: Name Address - — Photo Number BttildC'S; O ltji%. �1�j1� .,1 ri i- ,07TR 3_ L/ -01��'1 �.. Plumber Mason Blectriciat Dgg1 Qu: please sign below after you have carofally read the statement: To the best of my lmawledga the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be doao on the described premises and that all provisions of the Building Code,the Zoning ordinanco and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Ilwe shall submit,prior to a Cvrtittcate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an s Ug jU d'a=by a licensed surveyor;drawn to scale,showing actual location of all now construction. i•s ! `yet; ( Signature; �cr� ovr:aax,owner s agent,architect,contractor U Queensbury Building & Code Enforcement - Residential Final Inspection ,� a / �-� d ///�-x.� Office No.(518)761-8256 Arrive: ar�/ De rt: _ ?arr3/pm t_ Date Inspection request received: -7 Inspector's Initia NAME: S-C GtL� I PERMIT#: LOCATION: Md�-, o DATE: OtI _ S TYPE OF STRUCTURE: pry-- / -- Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs, decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %Z" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tern 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom I Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Batter backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/'/<hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in,x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"acces , 1 s . f3.-150 s .ft. vents Building No./Addres visib frg d Final Electrical Site Plan /Varianc re ui ed Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Pennit No........................................Cert. 85462 Cut-in Card No............................2 Owner.................... 0�!.xk...........15.c2- ................................................................................................ Location........... ........�►.Ym.m o n_5........k.Y.. ....................................................................................... Installation Consisting of.......l 12..Qx.r Q a. ... ...... ...... .L 2. g'.5;f...... �.Q...S. j....... .!-5�....... .. 7?. Y.......4A..�cades.... s ...................................... .................................................................................................................................................................................... InstalledBy......._Vd.rnJ�.............................................................Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making inspections at any time, and if its rules are violated,the Company shall have the right to revoke this certificate. Date.......... INSPECTOR... .......................................................................... Member N.F.P.A.,I.A.E.I. Rough Plumbing / Insulation Inspection Report Office No. (51 8) 761-8256 Date Inspection request received: v p Queensbury Building& Code Enforcement Arrive: am/p{{�� Depart:y • am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:zyze NAME: PERMIT #: r / LOCATION: INSPECT O TYPE OF STRUCTURE: Y N N/A PVC: R-1, R-2, R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. �1 Plumbing Vent/Vents in Place / Rough Plumbing/Nail Plates 1 % inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest C C ) L-1/`r kit connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping 4C00JR&Commercial o er, CPVC,Pex One and Two-Fa sulation/Residential Check/Comm cial Check VIA Pr o er Vent,,Attic Vent Duct/Hot Water Piping Insulation If required unheated s aces Combustion Air Supply for Furn ce Duct work sealed properly/No Ouct tape COMMENTS: L:\SueHemingway\Building.Codes.hispection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Mar) , . Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: r Queensbury Building& Code Enforcement Arrive: a �pepz rt pm [ ; 742 Bay Road, Queensbury, NY 12804 Inspector's Initial L� NAME: (' PERMIT#: w - ��� LOCATION: m INSPECT ON: TYPE OF STRUCTURE: Y lv iv/a COMMENTS <raming - Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour !"Frestopping / G Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade I 'jtia!nuary z5�. LASueHemin,wa \Buildino.Codes.Ins Inspection. Firesto ing In Y � P S pp c Inspection Report.d 9_30� Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release 1 Data filename:C:\Program Files\Check\REScheck\91404 CATONE-TIMMONS ROAD,QUE Y,Lk TITLE:PLAN NO.91404 . OCT ® B 2004 TOWN OF QUEENSBURY COUNTY: Warren BUILDING AND CODE STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE:09/24/04 DATE OF PLANS: SEPTEMBER 24,2004 PROJECT INFORMATION: TONY CATONE TIMMONS ROAD QUEENSBURY,NEW YORK 12804 COMPANY INFORMATION: WILLIAMS&WILLIAMS DESIGNERS 509 GLEN STREET GLENS FALLS,NEW YORK 12801 COMPLIANCE:Passes Maximum UA= 151 Your Home UA=l l7 22,5%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 704 38.0 0.0 21 Wall 1:Wood Frame, 16"o.c. 664 19.0 0.0 35 Window 1:Wood Frame:Double Pane with Low-E 48 0.320 15 Door 1:Glass 40 0.330 13 Floor 1:All-Wood JoisbTruss:Over Unconditioned Space 704 19.0 0.0 33 Furnace 1:Forced Hot Air,92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Builderoesii;gne Date REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release 1 DATE:09/24/04 TITLE:PLAN NO.91404 Bldg. Dept. { Use Ceilings: [ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R 38.0 cavity insulation Comments: { Above-Grade Walls: [ ] 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: { 1 Windows• [ ] { 1. Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.320 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: Doors: Door 1:Glass,U-factor:0.330 Comments: Floors: [ ] 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-19.0 cavity insulation Comments: ( Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,92 AFUE or higher Make and Model Number Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating { equipment must be provided. [ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ J Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: { ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: { ) All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation`Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts _Temperature(F) Up to P Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Pipin System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 . 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)