Signed Inspection Report (Mon Jul 26, 2021 at 218 PM)INSPECTION WORKSHEET (FRM-012279-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0261-2020 Case Module:Permit
Inspection Date:Mon Jul 26, 2021 Inspection Status:Partial Pass
Inspector:Smith, Mark Inspection Type:Building Framing
Job Address:Parcel Number:12 SHORE ACRES RD
Queensbury, NY, 12804
227.17-1-11
Contact Type Company Name Name
Contractor J. Clarke Construction
Applicant Frazier, Daniel
Applicant Frazier, Meghan
Primary Owner Frazier, Daniel
Granted Permission J. Clarke Construction
Architect Phinney Design Group
Primary Owner Frazier, Meghan
Checklist Item Status
Jul 26, 2021 Page (1)
INSPECTION WORKSHEET (FRM-012279-2021)
Checklist Item Status
Building Inspector Notes Failed
6/25/21 Building Framing Partial Approval
Items discussed and need to be addressed:
- Check roof rafters to verify all hurricane clips are in place.
- Provide detail on 18" micro-lams sistered to floor trusses in basement at rec room due to fireplace above.
- Provide Firestopping at lowered ceilings, soffits, tops of utility chases and dead spaces.
- Anchor bolts missing at basement bathrooms 1 & 2 exterior walls.
- Discussed 1 hour drop ceiling in both mechanical rooms. Submit documentation.
- Does the 5-1/4"x5-1/4" PSL Bearing Posts require a bracket at 5-1/4" x 14" LVL Ridge Beam in bonus room
above garage.
- Scott your fastener page S002 shows basically nailing requirements. John stating quite a bit of fastening was
done with structural screws(Timber Tech
Screws). Please provide a letter stating these screws are an acceptable alternative for fastening.
7/12/21 ice and water shield verified at east side of garage only
7/19/21 ice and water shield verified at upper dormer on garage, street side, first two rows on lower roof lake side
garage.
7/26/21 ice and water shield at garage breeze way and gable at south end front side main house verified
Framing Passed
6/25/21 Building Framing Partial Approval
Items discussed and need to be addressed:
- Check roof rafters to verify all hurricane clips are in place.
- Provide detail on 18" micro-lams sistered to floor trusses in basement at rec room due to fireplace above.
- Provide Firestopping at lowered ceilings, soffits, tops of utility chases and dead spaces.
- Anchor bolts missing at basement bathrooms 1 & 2 exterior walls.
- Discussed 1 hour drop ceiling in both mechanical rooms. Submit documentation.
- Does the 5-1/4"x5-1/4" PSL Bearing Posts require a bracket at 5-1/4" x 14" LVL Ridge Beam in bonus room
above garage.
- Scott your fastener page S002 shows basically nailing requirements. John stating quite a bit of fastening was
done with structural screws(Timber Tech
Screws). Please provide a letter stating these screws are an acceptable alternative for fastening.
Attic Access 22 x 30 minimum Failed
Cont Hdrs/Strapping/Nailing Grid for Garage Door Failed
Jul 26, 2021 Page (2)
INSPECTION WORKSHEET (FRM-012279-2021)
Checklist Item Status
Truss Specification Provided Failed
Bracing Bridging Failed
Hurricane Clips/Uplift Screws/Nail Holes Filled Failed
Air Seal all Plates and Sills Failed
Air Seal All Registers at Floor Failed
Air Sealing all Joints Before Insulation Failed
Joist hangers Failed
Jack Posts Main Beams Failed
Deck (post beam connections hex head bolts)Failed
Exterior sheeting nailed properly Failed
12 O.C.Failed
Headroom 6 ft. 8 in.Failed
Jul 26, 2021 Page (3)
INSPECTION WORKSHEET (FRM-012279-2021)
Checklist Item Status
Notches Holes Bearing Walls Failed
Metal Strapping for Notches Top Plate Failed
Draft stopping 1,000 sq. ft. floor trusses Failed
>1000 s.f. then firestop must be installed Failed
Anchor Bolts 6 ft. or less on center Failed
Ice and water shield 24 inches from wall Passed
7/12/21 ice and water shield verified at east side of garage only.
7/19/21 ice and water shield verified at upper dormer on garage, street side, first two rows on lower roof lake side
garage.
<4:12 pitch double layer of ice/snow underlayment - over lapped 19"Failed
Soffits-Insulation Baffel Failed
Windows Habitable Space Bedrooms Failed
24 in. (H)Failed
20 in. (W)Failed
Jul 26, 2021 Page (4)
INSPECTION WORKSHEET (FRM-012279-2021)
Checklist Item Status
5.7 sf above below grade Failed
5.0 sf grade Failed
Design Professional Sign-off, if required Failed
Jul 26, 2021 Page (5)
Smith, Mark