Signed Inspection Report (Mon Jul 26, 2021 at 218 PM)INSPECTION WORKSHEET (FRM-012279-2021) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0261-2020 Case Module:Permit Inspection Date:Mon Jul 26, 2021 Inspection Status:Partial Pass Inspector:Smith, Mark Inspection Type:Building Framing Job Address:Parcel Number:12 SHORE ACRES RD Queensbury, NY, 12804 227.17-1-11 Contact Type Company Name Name Contractor J. Clarke Construction Applicant Frazier, Daniel Applicant Frazier, Meghan Primary Owner Frazier, Daniel Granted Permission J. Clarke Construction Architect Phinney Design Group Primary Owner Frazier, Meghan Checklist Item Status Jul 26, 2021 Page (1) INSPECTION WORKSHEET (FRM-012279-2021) Checklist Item Status Building Inspector Notes Failed 6/25/21 Building Framing Partial Approval Items discussed and need to be addressed: - Check roof rafters to verify all hurricane clips are in place. - Provide detail on 18" micro-lams sistered to floor trusses in basement at rec room due to fireplace above. - Provide Firestopping at lowered ceilings, soffits, tops of utility chases and dead spaces. - Anchor bolts missing at basement bathrooms 1 & 2 exterior walls. - Discussed 1 hour drop ceiling in both mechanical rooms. Submit documentation. - Does the 5-1/4"x5-1/4" PSL Bearing Posts require a bracket at 5-1/4" x 14" LVL Ridge Beam in bonus room above garage. - Scott your fastener page S002 shows basically nailing requirements. John stating quite a bit of fastening was done with structural screws(Timber Tech Screws). Please provide a letter stating these screws are an acceptable alternative for fastening. 7/12/21 ice and water shield verified at east side of garage only 7/19/21 ice and water shield verified at upper dormer on garage, street side, first two rows on lower roof lake side garage. 7/26/21 ice and water shield at garage breeze way and gable at south end front side main house verified Framing Passed 6/25/21 Building Framing Partial Approval Items discussed and need to be addressed: - Check roof rafters to verify all hurricane clips are in place. - Provide detail on 18" micro-lams sistered to floor trusses in basement at rec room due to fireplace above. - Provide Firestopping at lowered ceilings, soffits, tops of utility chases and dead spaces. - Anchor bolts missing at basement bathrooms 1 & 2 exterior walls. - Discussed 1 hour drop ceiling in both mechanical rooms. Submit documentation. - Does the 5-1/4"x5-1/4" PSL Bearing Posts require a bracket at 5-1/4" x 14" LVL Ridge Beam in bonus room above garage. - Scott your fastener page S002 shows basically nailing requirements. John stating quite a bit of fastening was done with structural screws(Timber Tech Screws). Please provide a letter stating these screws are an acceptable alternative for fastening. Attic Access 22 x 30 minimum Failed Cont Hdrs/Strapping/Nailing Grid for Garage Door Failed Jul 26, 2021 Page (2) INSPECTION WORKSHEET (FRM-012279-2021) Checklist Item Status Truss Specification Provided Failed Bracing Bridging Failed Hurricane Clips/Uplift Screws/Nail Holes Filled Failed Air Seal all Plates and Sills Failed Air Seal All Registers at Floor Failed Air Sealing all Joints Before Insulation Failed Joist hangers Failed Jack Posts Main Beams Failed Deck (post beam connections hex head bolts)Failed Exterior sheeting nailed properly Failed 12 O.C.Failed Headroom 6 ft. 8 in.Failed Jul 26, 2021 Page (3) INSPECTION WORKSHEET (FRM-012279-2021) Checklist Item Status Notches Holes Bearing Walls Failed Metal Strapping for Notches Top Plate Failed Draft stopping 1,000 sq. ft. floor trusses Failed >1000 s.f. then firestop must be installed Failed Anchor Bolts 6 ft. or less on center Failed Ice and water shield 24 inches from wall Passed 7/12/21 ice and water shield verified at east side of garage only. 7/19/21 ice and water shield verified at upper dormer on garage, street side, first two rows on lower roof lake side garage. <4:12 pitch double layer of ice/snow underlayment - over lapped 19"Failed Soffits-Insulation Baffel Failed Windows Habitable Space Bedrooms Failed 24 in. (H)Failed 20 in. (W)Failed Jul 26, 2021 Page (4) INSPECTION WORKSHEET (FRM-012279-2021) Checklist Item Status 5.7 sf above below grade Failed 5.0 sf grade Failed Design Professional Sign-off, if required Failed Jul 26, 2021 Page (5) Smith, Mark