Loading...
2004-864 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building & Codes (518) 761-8256 MPLIANCE k_—erniitNumber __ -p-20040864 = _. j_Date Issued:: Friday, January 13, 2006 This is to certify that work requested to:bewdone as shown by Permit Number P20040864 has been completed. Tax Map Number: - 523400-308-019-0001-034-000-0000 - Location: _. - 40 OGDEN Rd Owner:_._ THOMAS & JOAN WELCH --- .:Applicant: - THOMAS & JOAN WELCH This structure may be occupied as a: Garage - 1 Car Detached By Order'of Town Board _ TOWN OF QUEENSBURY Issuance-of this Certificate of Compliance DOES NOT relieve the property owner-of the responsibility for compliance with Site Plan, �Q( Variance,-or other-issues-and conditions as a-result-ofapprovals-by the- —- ... Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&•Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040864 Application Number: A20040864 Tax Map No: 523400-308-019-0001-034-000-0000 Permission is hereby granted to: THC)MASI& T0AN WF1,C;H For property located at: 40 OGDEN Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. 1 Tyne of Construction Value Owner Address: THOMAS & JOAN WELCH PO BOX 23 Garage- 1 Car Detached $4,500.00 Total Value $4,500.00 GLENS FALLS, NY 12801 , f Contractor or Builder's Name Address Electrical Inspection Agency 1 qi i f i r Plans&Specifications 2004-0864 312 SQ FT 1-CAR ATTACHED GARAGE; i $31.20 PERMIT FEE PAID-THIS PERMIT IiXPIRES: Saturday, October 29, 2005 i (If a longer period is required,an application for an'extension'm st be made to.the code Enforcement Officer of the Town of Queensbury before the expiration date) 1 � Dated at the Town eensbu Friday, Octo,be`r 29, 2004 , 1 SIGNED BY r ! for the Town of Queensbury. Director of Building& de En •rcement. " - I Building Permit Application Town of Queensbury—Dept of Community Developmcnt,742 Bay Road,Queensbury,NY (518)761-8256- I A permit must be obtained before beginning construction. Permit File No. No inspection will-be made until applicant has received a Fee Paid valid building permit. All applicants' spaces on this Ree.Fee Paid $ application must be completed and must appear on the Reviewed By: application form. Applicant: Owner: Address: Address: I 6 � Phone Phone# Property Location: Lot Number: / House Number / lSubdivision Name• Tax Map Number: 0 New Building: residence /commercial 'Estimated Market Value of Construction: $ 0 . a Addition: residence/ commercial If an Addition,what will use of new addition be? a Alteration: residence/ commercial a No change to exterior size: residence/com'1 a Other work(describe } Check Occuponeylnformation 1` Floor 2° Floor Other floor Total Below sq.ft, sq.ft, sq.ft. Square Feet o Single findly dwelling a Two famil dwellin a Townhouse a Multifamily dwelling #of units a Office a Mercantile a :Manufacturing 0 1 car detached garage a 2 oar detached prage a 3 car detached 9=90 a 1 oar Washed garage a a 2 oar attached garage a 3 car attached garage a Storage building- commercial a . Storage building- residential a Other What is the proposed height of the structure feet inches Will any second-hand or ungraded lumber be used? If so,for what? Type of Heating System: electric/ oil / gas/wood /forced hot air/ baseboard/other: N ber of FIrenlaces to be installed Number of hoc Bey to be installed L below the person(s)responsible for supervision of work as regards to building codes: Name Address- Phone Number Builder Plumber IMason i l ;Electrician 1);ecl=6= please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Uwe shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an As Built t Survev by a licensed surveyor,drawn to scale,showing actual location of all new construction. Signature: owner,owner's agent,architect,contractor Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: sX >L �am/pm Depart:, l,'J am/pm Date Inspection request received: Inspector's Initials: �t NAME: PERMIT#: V 0 q � V � LOCATION: DATE: — TYPE OF STRUCT RE: Comments Yes N® N/A �.,1 1 � Building Number/Address visible from road s Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall 1 Interior/Exterior Railings 34 inches to 38 inches v Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backu : Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure / Final Electrical V Final SurveyPlot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certiftcation,if required Okay to issue C/qor C/® F Temporary/Permanent] L:\Building&Codes Forms\Building&Codes inspection Forms\Residential Final Inspection Form—revised—I 00405.doc L W%QF LIVAOVAug r� N0. L. CM �a f cz M M '"7 412 40 40 JR 41 " ' 'a .