Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2004-882
' TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Pernut Number. P20040882 Date Issued: Monday, August 27, 2007 This is to certify that work requested to be done as shown by Permit Number P20040882 has been completed. Tax Map Number. 523400-308-018-0001-058-000-0000 Location: 52 NORTH CHURCH Ln Owner. MALCOLM & GLORIA O'HARA Applicant: MALCOLM & GLORIA O'HARA This structure maybe occupied as a: Deck By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: P20040882 Application Number: A20040882 Tax Map No: 523400-308-018-0001-058-000-0000 Permission is hereby granted to: MAI,(;OLM& C'LORIA O'HARA For property located at: 52 NORTH CHURCH Ln in the Town of Queensbury, to construct or'place ' at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. � Tvne of Construction Value Owner Address: MALCOLM& GLORIA O`HARA Deck $6,000.00 52 NORTH CHURCH Ln Total Value $6,000.00 QUEENSBURY, NY 12804 Contractor or Builder's Name/Addressii Electrical Inspection Agency BARNES CONSTRUCTION 236A DIXON Rd OITEENSBITRY_ NY 12804-0000 Plans&Specifications 2004-882 432 SQ FT DECK $43.20 PERMIT FEE PAID -THIS PERMIT EXPIRES: Saturday, November 05, 2005 (If a longer period is required,an application for an extension must be made to the'code Enforcement Officer of the Town of Queensbury before the expiration date.); i Dated at the own f Quee b Fr`day,November 05;2004 A SIGNED BY �'� ' for the Town of Queensbury. Director,of Building&'Coe Enforcement Torch, Deck, Dock, or Boathouse Permit Application Town of Queensbury—Dept of Community Development, 742 Bay Road, Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. No Permit File No. inspection will be made until applicant has received a valid Fee Paid $ building permit. All applicants'spaces on this application must be completed and must appear on the application form. Reviewed B Applicant: a Owner: `M1,6 e Address: Z, �r x�N Address: �Z iV ��i Gry Veers o K931 ZSO Av 2 c /V l 2 SO f Phone#(4U2)7�- Phone#(W)IV-_4-4L49 Email Address: Email Address: Person Responsible for Supervision of Work as Regards to Building Codes: Name SAILAVC-S Address: 2-30A D 1 xa N VJ Phone S1$ - 761-01{z3 eeNSti3L�u,, Property Location: Lot Number: / House Number S Z / N. CAuU k LAive 4 uUe-<tsgc l Subdivision Name: •�n.RD C 10SP-- Tax Map Number: 3 6 Estimated Market Value of Construction: $ 4 (1 7, ' ❑ Porch '� V`t 1 uo k Ido V. 0 3 2004 ❑ Boathouse - ❑ Other work(describe ony Size of structure to be built q5 2 square feet Submit along with this application: 1 l. Two plot plans drawn to scale,preferably using a survey map. Indicate proposed structure showing setback dimensions from all property lines. Show location of water supply and location and configuration of septic disposal area. 2. Two sets of structural drawings. Indicate size of posts or studs, floor j oists, decking or flooring material to be used. Show how the porch or deck will be fastened to the building. If a roof will be constructed, indicate the size of posts or studs,roof rafter spacing and span. Indicate type of roof: sloped, flat, shed, or other. Indicate the type of material being used for the roof. Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and; specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the propose ork shall be complied with,whether specified or noted,and that such work is authorized by the owner. Applicant's signature: Date: ZS ®x L:\.SueHemingway\Building.Permit.FORMS\Porch.Porch.PermiGdoc 8/13/02 revised per DH �fKV7i^(�., QueensburY Building & bode Enforcement - Residential Final Inspection 1kate e No.(518)761-8256 _ Arrive: p am/pm Inspection request received: Ins ecto s itialam: p .—. NAME: PERMIT#: LOCATION: Z� - TYPE OF STRUCTURE: _ Comments Yes No rd/A BuildingNumber/Address visible from road ChimneyHeight/"B"Vent/Direct Vent 'Location pe - Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete [Aer 01111 . ! �— Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade V Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Pt Interior/Exterior Railings 34 inches to 38 inches % �,® a Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 14--<� f K"S 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches ©6 Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety lain Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Batterybackup: - Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window G Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Tern 110 Enclosed Stairs Sheetrock Underside minimum/:"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/a hour fire door/door closer Duct work Sealed propeft Gas Log s in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept..Inspection Sticker Site Plan /Variance required ` Flood Plain Certification,if required [-0kay to issue C/C or C/® [Temporary/Permanent L:\Building&Codes FormslBuilding&Codes\inspection Forms\Residential Final Inspection Form—revised-1 00405.doc Septic Inspection Reen rt Office No.(518) 761-8256 Date Ins ectiQueensbury Building&Code Enforcement Arrive: 742 Bay Rd., Queensbury,NY 12804 Inspector's In NAME: ��(2��R� F i 1 QC��-��I�LOCATION: — ,7, - Cn RECHECK: c�j F PT�C� f� hTEm F I.�auc) i�OD1�10 Comments and/or diagram Soil Typ . Sand LLoam/Clay Type of Wate .-MunicipaQ Well Water Waterline separation istance Well separation distance ft. Other wells: ft. Absorption Field: Total length / ft. Length of each trench ft. Depth of trenches ft. — Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank 1AI &AA LID Tank to Distribution Box I% Pit 1AUAy l� Opening Sealed: Y/N/Partia End Caps Location/Separations Foundation to tank ft. Foundation to absorption Separation of Pits C er Plot Pl Y Engineer Report s-Built Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: pproved Partial Approved and needs to be re-inspected, please call the Building& Codes Office Disapproved Last revised 1/6/05 Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection re est eiv d: Queensbury Building&Code Enforcement Arrive: =O� Depart: 742 Bay Road, Queensbury,NY 12804 Inspector's Initia i NAME: 1-�(—,C F_R�h (��`�. PERM # 7-0 D '4 _'r?,q� LOCATION: C;Q R l O [�D DAT —1, COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq. ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/2 doors > 10%> 1000 s .ft. 3/4 Hour Corridor Doors &Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 s . ft. Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible —Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in. Beyond Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification, if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20' wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc Inspection for Permit to Occupy Fire Marshal's Office Request Rec'd Permit No. Town of Queensbury 742 Bay Road ,. Queensbury,NY 12804 Scheduled Inspection Date: !% Time: Phone: (518) 761-8206 Business Name- 5c?le- Fax: (518) 745-4437 Location: Z£ Type of Inspection N/A Yes No EXITS: Exit Access COMMENTS Exit Enclosure Exit Discharge AISLES: Main Aisle Width Secondary Aisle Width EXIT SIGNAGE Sign-normal Sign-battery TRUSS ID SIGNAGE EMERGENCY LIGHTING FIRE EXTINGUISHER: Hun Inspection of extinguisher Hydro extinguisher FIRE ALARM SYSTEM Fan Shutdown Fire Sp rinkler System Fire Suppression-kitchen Fire Suppression-Gas Island Hood Installation Interior Finishes Storage Compressed Gas Clearance to Sprinklers Clearance to Electrical Electric Wiring Enclosed Combustible Waste Vehicle Impact Protection Fire Lane F.D.Si na e-Utility Rooms No Smoking Si ns Maximum Occupancy Sign Emergency Evacuation Plan pproved (If no other approvals apply,the B&C Office will issue the Certificate of Occupancy) ❑ Denied o Call for Recheck _ Inspected y:. Y L:\Sue Hemingway\Fire Marshals Office Inpsection 08.17.2005.doc General Notes LANDING EXISITNG SIDE WALK (2) 200 �� CARRIER BEAMS —— —— DN 8"o \� SONOL TUBES — 2x6 DECKING (2) 2x10 ` CARRIER BEAMS ao 200 JOIST WITH HANGERS (TYP) 16" O.C. ,4 \� 8"0 SONOL TUBES (2) 2x10 CARRIER BEAMS r. DN \ 171 24' TOP DE�-C-K VIEW a CALE: 1/2"=1'-0'1 ^ 44 POST TOP OF RAIL 0 ISSUED FOR REVIEW 10/1w + No. Revision/Issue Date Copy I Firm Name and Address M -Kv 2x6 DECKING ;n 200 JOIST 6" O.C. ; BARNES CONSTRUCTION j 6x6 POST $ - U�LD �� 22S A Dlxan Ad Cq REVIEWED GRADE I el UATr~ Nov 0 , Project Name and Addressm I I I 1 1 I i I I I �'c • , D T I I I I I I I i �l.•��I'i�Jt-�,v .� ;n,i� `3'.i rt ° ,r� ''' I I Bases , �a f, If ' ��� � �• 52 NORTH CHURCH LN. x I I I I I I I I 00 com �ance u�� J L nat �nrar , �� v� e Q U E E N S B U RY 1 r' Sans spe-afitac.-�s erg �� li I I I I I I I I —i L——————� L-——— I I ;anr :°�i;n ks; E�ii�a.•�Ct�� NEW YORK 1' 5'-6" 5'-6" 5'-6" 5'-6" 1' Project Sheet 12' 12' 062 Dote 24' 10/19/2004 Scale 1/2"=0'-1' FRONT ELEVATION VIEW SCALE: 1/2"=1'-0" U General Notes <r73tj A 1 7 1 o tM f I� I MIMw: IOwi IV 1 _ E 7 t n uww oww es II II f II II II I II II II II II II o ISSUED FOR REVIEW low II (I No. Revision/Issue Date II II Firm Name and Address BARNES CONSTRUCTION w236 A Dixon Rd \� QueensbuM NY 12804 Project Name and Address OHARA DECK 52 NORTH CHURCH LN. QUEENSBURY NEW YORK Project Sheet 062 �i 3n r-1 d�� oat 10/19/2004 2 scow EXISITING STRUCTURE PLANS 3/1 S"-l'--O* SCALE: 3/16"=1'—0' > r.