Loading...
2004-921 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20040921 Date Issued: Tuesday, March 11, 2008 This is to certify that work requested to be done as shown by Permit Number P20040921 has been completed. Location: 273 STATE ROUTE 149 Tax Map Number: 523400-278-000-0001-008-002-0000 Owner: J H LAND DEVELOPMENT LLC Applicant: JOHN HUGHES This structure may be occupied as a: Garage - 2 Cars Attached By Order of Town Board Single Family Dwelling TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040921 Application Number: A20040921 Tax Map No: 523400-278-000-0001-008-000-0000 Permission is hereby granted to: JOHN Hi TCTHF,S For property located at: STATE ROUTE 149 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value- Owner Address: JOHN HUGHES 1 ROCKLAND Dr Garage-2 Cars Attached LAKE GEORGE, NY 12845 Single Fanuly Dwelling $75,000.00 Total Value $75,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency JOHN H[7GHES 38 LEDGEVIEW Dr LAKE CTEORCTE_ NY 12845-0000 Plans&Specifications 2004-921 273 STATE ROUTE 149 JOHN HUGHES SINGLE FAMILY DWELLING $218.40 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday, December 20, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the;FTmq Que bu7yy; , December 20, 2004 ,; SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement i Building Permit Application Town of Queensbury—Dept of Community Development,742 Bay Road,Quemsbury,NY (518)761-8256 i A permit must be obtained before beginning construction. Permit File No. 1— . No inspection will be made until applicant has received a Foo Paid $ qc� valid building permit. All applicants' spaces on this Rec.Foe Paid application must be completed and must appear on the Reviewed By application form. Applicant: ?„�N,�1�. �/, ;�i�s eo Owner: G N Address: Address: I /ZorkAly i, DR I v-C l a kIP a e-op a c Phone#(Ste),7� - 0` Phono#(s/D -1,?A- Property Location: Lot Number: a'7 / House Numbers i?T. / �1' 4 T J��• Subdivision Name: Tax Map Number: 0-7 New Building. esid /commercial 'Estimate`-d My iketYV ll-i-of•Construction: M Addition: residence/ commercial If an C Alteration: residence,/ commercial Addition,what will use of new addition be? 0 No ehaage to exterior size: residence/com'1 a Other work(describe ) Check OccupancyWormation ill Floor 2° Floor Other floor Total 13e10w sq.it, sq.ft. sq.It. Square Feet s/ Sin a Anii1y dwelling / /q (D o Two P!Sk dwelling o Townhouse o Multifamily dwelling s #of units o Offico o _ Mercantile a Maalufactutin 0 1 car detached SaMp 0 2 oar detached gego a 3 car detached prage v 1 oar attached prage a]/ 2 car attached garage v 0 3 car attached gamgo o Storage building- commercial o Storage building- residential o Other What is the proposed height of the structure feet inches Will any second-band or ungraded I=ber be used? If so,for �what? -, 14 c? Type of Heating Systom: electric/ oil / gas/wood / / baseboard/other: Number of Mr-enlaces to be installed „L y Number of Woodstoves to be installed,1—,2,,)_, List below the persons)responsible for supervision of work as regards to building codes: Name Address- Phone Number Builder W i9 Plumber Mason :.v 1Electrician toqRpR,j 49�3 -16 6 o D'eelaration; please sign below after you have carefully read the statement: To the best of my lmowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described promises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Vwe shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an js By Survey by a licensed surveyor;drawn to scale,showing actual location of all new construction. SignaturC: n OwneT,omen's agent,ardbitect,contractor Check Residential Plan Review: One&Two Family Dwellings Y/N/N/A V (2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans:90 Wind Floor Loads 40 psf _--_� 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: ` Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. 1 Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height above floor / Residential Check Paperwork Compliance and Inspectors Checklist: OK t� Dampproofing./Waterproofing Materials On Plans. Foundation Drainage On Plans,if required 'jZ 6"Drop in 10'Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where uired Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise Winder Run and Rise Spiral Not Allowed From 2nd Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance v Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/_Closed Risers More Than 4"in Ht. } Safety Glazing Notes For Required Areas UGarage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30" Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results,if required p Septic To Well Or Water Line Separation Paperwork Signed Project Name: r/ /� BP# Address: ,27 3 Building Pemut Submission SFD Qwcklist 2-Family All items belowmust be checked either yes,no ornot applicable prior to submission of anybudding. permit to the Town of QueensburyBuildingDepartrnent_ If anyof the belowite=are laclring,the permit-, wM not be accepted until such time as the application is deemed complete for submssim 1. Building Pemnt Application Completed ...............................Y. .. Oyes ❑no ❑rr/a 2. EneWForm or CheckMate Energy Code Compliance Forms Complete.. ❑yes []no []n/a (2 copies) 3. Energy Code Inspector's Report from CheckMate Program................ ❑yes ❑no ❑n/a (2 copies). 4. Septic application completelyfilled out(f applicable)........................ Oyes ❑no ❑n/a 5. Solid Fuel B or Gas Appliance Form_..- App ......... .........................0Yrs Ono Eln/a 6. Electrical Inspection Form....................:............................... .. Dyes []no 6n/a 7. Two(2)complete sets of st vam-al drawings... _H5 Ono (]n/a ....................... a) floor plan;b)foundation plan;c)cross sections:d)elevations; e)window and door schedule 8. Two(2)site plans showing location of'the structure to be bunt,............ g ono '[]n/a location of well or water lines,location of septic system or sewer line. 9. Sethado from pmpentylines to new structure................................ []no []n/a 10. Setbacks to neighboring wells and septic systems,including oasite well__ - [lyes Qno En/a and septic systems(if applicable) 11. DrivewayPemut.................. ... ...... ................... . ..... ........... Elle'lJno Ejn/a Date: 6 i Staff Inival _ __ _ -_^^_.�..� - ... �.•_�__ i.,.-....-..tee '7M4 Application for Permit=Septic Disposal SYstem Town of Queensbury 742 Bay Road Queensbury,NY 12804 (51 8) 761-8256 1. OWNER INFORMATION: ..................................................................,.,..................... ....,,,..,,,........,-...,..... .. � Office Use Location of installatio�:��ST Rf l�-r• �G•� �t1�:_•_ ���-� File Permit No. Tax Map No.��/ � /.� ' �o�iu � �Uc / �� C o.v / Feo Paid Owners Name: !�, 5'` Address: EIL) 2. INSTALLER'S NAME : PHONE NO. 3. RESIDENCE INFORMATION: (circle year of dwelling,indicate#i bedroom(s) and multi�13 2004 bedrooms with applicable gallons per bedroom to equal td�"i WILDING AND CODE BedroomYear Of H-quSe" Ng of ��E 1980 or older x 150 gallbdrm - 1980—1991 x 130 gal/bdrm 1991—present x 110 gal/bdrm = 2 U Garbage Grinder Installed yes l no Spa or Hot Tub Installed yes ! no �G 4: PARCEL INFORMATION: (circle applicable information&indieato measurements) Tobouranhv Soil Nature Ground Water Bedrock or Impervious Material Domestic Water Smply .Flat sand at what depth at what depth municipal Rolling loam feet feet well Steep slope clay we ; water supply !%slope other 9��'�U� from any septic-system depth, absorption is 1 n 0 other Percolation Test: (To be completed by.licensed professional engineer or architect) Rate: minute per inch 5. PROPOSED SYSTEM: Eor New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septio Tank: /10()() gallon(min.size 1,000 gat) Tile Field: each trench ft; Total System Length: d-0 U Seepage Pit(s): number of size of each: ft. by ft; Size Stone to be used: # / depth or thickness feet Bed,System Size: S�'-0 x 0 Alternative System: length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons i TOTAL Capacity: gallons Note: Alarm Sy_stem.and.associated-electrical-worlcmust lie inspec o&by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. � D Signature of espon .i perso Date 1 1 ,71 • , M ' � r'1'aw''tr �c�f ��Liuc;tr�I�Ltr•y • �5ci�vc::•:t :t»cl �ic:wti�;c; I)i,���t�Kstl t:trs;tsi�•t• 1�I��rc;itch x t: � • c • SEPARATION "S 1'Itk ABM •�� _ ......,r ...._,_.--_...... .... ,._._R. powb l � trtis�n• • �twr�rc v��►t� r ' N I•• . 'I',,I , 10 i Sc���1G • lj,� 'r 1rit•tY.' ..•....•.. 1 �� y x'�LSCtI:.t111rt t FrititL� � • w ' 1•..••�'"'� ROAD 1 M NO .I r � • 7. SIC�T�i�P►."I.'t &",I�IgORt�rZ,ATi4�I'�Qk�lfi�k't�i*E��xss��r:�v:��+„r,��.•.••••,•, • y Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: arn/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: �`.,���— �� l _ . �J PERMIT#: � ��jL LOCATION: -9-23 / INSPECT ON: AZ TYPE OF STRUCTURE: Framing N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity.min. Garage Fire Separation House side %2 inch or 5/,8 inch Type X Garage side 5/8 inch.Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Queensbury Building & Code (Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: i ' am Depart: ant/pm Date Inspection request received: Inspector's Initials: NAME: PERMIT#: LOCATION: DATE: !-1 TYPE OF STRUCTURE: ' i I Comments: Yes No NIA 4" Building Number Address visible from road Chimney Height/°B'Vent/Direct Vent Location Fresh Air Intake / �lJ� 3 inch PlumbingVent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers 7 Guards at stairs,decks,patios more than 30 inches above grade �2 ©�� 7�/O T Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Brawn /Handigapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/ ulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: _ Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches i ht in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft:150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'A"Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct worts Sealed property Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certficatio ed Okay to issue C/C Of C/® m ra /Permanent LABuilding&Codes FormslBuilding&CodesXlnspecdon FormslResidential Final Inspection Form_revised_100405.doc;Revised January 7,2008 Queensbury Building & Code Enforcement - Residential Final Inspection'✓(' Office No.(518)761-8256 Arrive: �o am/pm ,Depart: am/pm / Date Inspection request received: _�/0]r Inspector's Initials: �, [ A+� NAME: V 7 PERMIT#: / y LOCATION: jqqDATE: TYPE OF STRUCTURE: _ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more a)stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete `� Interior/Exterior Railings 34 in.to 38 in. e,l e C r� Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18" above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Dete ors: Every level: / Every Boom: Outside every bedroomgea: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fire roofin,&/3/<hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, I s . ft.-150 s . ft. vents Building No./Address visible from roads Final Electrical /✓t�.r hG; Site Plan /Variance required n� Final Surve Plot Plan / A` / JJ�✓�� As Built Sept c System/Sewer Dept.Inspection Sticker lood Plain Certification, if required ka to issue C/C or C/0 f Temporar / er vent _ L:\PamW\Building&Codes\Inspection Forms\Res. Final Inso. form 2.docLast printed 2/12/04 n n �1 v i Act -so 00Y i AA Queensbury Building & Code Enforcement - Residential Final Inspection Y / --3 N) Office No.(8)761-8256 Arrive: j am/ m Depart: am/pmL P _ P_ Date Inspection request received: _ Inspector's Initials: NAME: Cr, _ PERMIT#: c=� ' LOCATION: DATE: TYPE OF STRUCTURE: ` Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake / 3 y, 3 inch Plumb Vent through roof minimum 6" i/«ilJ� c��/ G+ s41ri�3 Roof Complete/Exterior Finish Complete Guard 30 in,or more @ stairs,decks,patios r T� Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %2" Gypsum _ Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above rade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: n I f Every level: Lam/ Every Bedrgom: Outside every bedroom area: ✓ ✓ /A C Inter Connected: ✓/ Batter backup: d'` Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area CLe�1S Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents / Building No./Address visible from road jk J 4&�s r Final Electrical '/ Site Plan /Variance required Final Survey Plot Plan �i As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building &Codes\Inspection Forms\Res. Final Insv. form 2.docLast printed 2/12/04 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INCO Main Office 176 I<oe Run R,pad-Manheim,PA 17545 MUNICIPAL CERTIFICATi - ELECTRICAL APPROVAL Permit No........�.....``......,...,,...,...�Cert. ® 90117 Cut-in Card No.......................... Owner............ ............... ......1..`................................................................................... ....... PP Location............. . .....`..;�!... . j.....��' .....................................`"'z....�:� ............. Installation Consisting o .?�.V `� 7-C� g�:p z'l�j�I . ....... fur... r f.................... .......�a.Y- .r.S�,....��f.. ....... ........................................................................................... .......... ............................................................... Installed B AU, -P a- , l �............ Lic.No................................................... y.................................. ........................................ The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have.the privilege,of makin inspections at any time, and if its rules are violated,the Co any shall have the right to r o4tsc�ificateDate....... .`..�...................... INSPECTOR............... ...�................................................... Memher N.EP_A..I.A.E.1. Septic Inspection Report p Office No. (518)761-8256 Date Inspection r ues rec v d: Queensbury Building&Code Enforcement Arrive: am/ eparI am/ 742 Bay Rd., Queensbury,NY 12804 Inspector's Initi NAME: , RMIT NO.: — LOCATION: SPECT ON: - - RECHECK: _ I L�� Comments and/or diagram , Soil Type: Sand/Loam/Clay Type of Water: Municipal ell Water Waterline separation dista ft. Well separation distance _ �ft.-Ir' Other wells: ! ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Pi in- Size Type Building to tank Li,\ 13CANI- Tank to Distribution Box L41 t CIA Distribution Box to ield/Pit u L�F � - Opening Seale artial End Caps Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits Conforms as per Plot P Y Engineer Report a As-Built `Y v14 (s— Location of System on Property: Front Rear Left Side kight Side� - Middle Fro t Middle Rear System Use Stat s: Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved Last revised 1/6/05 z - ' 1 r Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection reque cei �� a Queensbury Building & Code Enforcement Arrive: /pmDepart: 742 Bay Road, Queensbury, NY 12804 Inspector's Initi is: NAME: � PEA IT �: -,7 14 - 7_ LOCATION: -73 !k 1'44 env ` '( -INSPECT ON: • S TYPE OF STRUCTURE: y N N/A ou h Plu bi Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Ai Head ' 5_P.51-br 10 ft. above highest connection for 15 minutes Pressure Test / Water Supply Piping Air/ Head f0 P.S.I for 15 minutes —6YAInsulation esidential Check / Commercial Check r . Proper Vent Attic Vent Duct / Hot Water Piping Insulation If.re uired unheated spaces Combustion Air Supply for Furnace _ Duct work sealed properly / No duct tape COMMENTtz- ` V-L/V��6L L:\Pam Whiting\Building&Codes\Inspection Forms\Rougb Plumbing Insulation Report.revised Nov 17 2003.d6c Revised February 15,2005 Framing / Firestopping Inspection Report l0 Office No. (518) 761-8256 Date Inspection r es re ive . Queensbury Building& Code Enforcement Arrive: arn/p D art: j a, m 742 Bay Road, Queensbury, NY 12804 Inspector's In' ials- NAME: ✓ PERMIT#' L — / 9 LOCATION: INSPECT ON',, — TYPE OF STRUCTURE: \ Y N r /A Framing h,C ` COMMENTS Jack Studs/Headers iJ C,\ Bracing/Bridging �j�, i�l� Joist hangers , Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. AF Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses F Anchor Bolts 6 ft. or less on center ' d sn shield 24 hes from wall Fire separation 1, 2, 3 hour ' Fire wall 2, 3, 4 hour Aw Firestopping 41 Penetration sealed k"`. 16 inch insulation in cavity in. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch�Type X Ceiling/wall Windows Habitable ., ce/Bedrooms 24 in. (H) j' 20 in. (W) AIV,-, 5.7 sf above p'low grade 5.0 sf grade/,jjjV LASueHemingway\Building.Codes.Inspection.FORM STraming Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection ques re e' ed: Z' Queensbury Building &Code Enforcement Arrive: am/ Depart: al a 742 Bay Rd., Queensbury, NY 12804 Inspector's Ini NAME: �.� RMIT#: 1- — LOCATION: j� Pc �_ �t� � INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A otings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproof-ing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Bui]ding.Codes.InspectionTORMSToundation Inspection Report.doc Januaiy 28,2003 Foundation Inspection Report Office No. 518 761-8256( ) Date Inspects r st r ce ed: _ Queensbury Building &Code Enforcement Arrive: a Depart: 9 an ` - 742 Bay Rd., Queensbury,NY 12804 Inspector's Ini NAME: PE IT LOCATION: �t")IN PECT ON: 10 TYPE OF STRUCTURE: Y N N/A Comments q r� Footings � c. Piers UU q Monolithic Slab Reinforcement in-Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing n ype of Dampproofing/Waterproofing V Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width k6 inches above footing ,61�rnil poly for wet areas under slab -'gackfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. I:1SueHemingway\Buii ding.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection requ s r e- Queensbury Building &Code Enforcement Arrive: m LIZ / Depart: ` a`m/p742 Bay Rd., Queensbury, NY 12804 Inspector's Initi NAME: RMIT#: LOCATION: INSPECT ON: � TYPE OF STRUCTURE: C�- Comments Y N N/A xootings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/ Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab _ Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingwaylBuilding.Codes,InspectionTORMSWoundation Inspection Report.doe January 28,2003 ti Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/p epart: am/pm Date Inspection request received: Inspector's Initials: 1 NAME: -T H �v_.a� �J�! me PERMIT#: ��� �/12 LOCATION:, ; 2 DATE: TYPE OF STRUCTURE: Comments Yes N® N/A BuildingNumber/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter'Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, I s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Tern 110 Enclosed Stairs Sheetrock Underside minimum''/s"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Los in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan � ,� �,�, As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc 51 .7 ^ �� e it u ber REScheck Compliance Certificate Checked By/13 e 2000 IECC REScheckSoftware Version 3.6 Release 1 Data filename:Untitled.rck PROJECT TITLE: State Route 149 House CITY: Glens Falls STATE:New York HDD: 7635 CONSTRUCTION TYPE: Single Family WINDOW/WALL RATIO: 0.15 DATE: 12/13/04 RECI V E® DATE OF PLANS: 11/18/04 DEC 132004 PROJECT DESCRIPTION: TOWN OF QUEENSBURY Single Family Dwelling:Ranch Style BUILDING AND CODE DESIGNER/CONTRACTOR: John Hughes Construction COMPLIANCE:Passes Maximum UA=263 Your Home UA= 182 30.8%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 1092 38.0 0.0 33 Wall 1:Wood Frame, 16"o.c. 994 19.0 0.0 50 Window 1:Vinyl Frame:Double Pane with Low-E 129 0.350 45 Door 1: Solid 17 0.230 4 Door 2: Glass 18 0.230 4 Crawl 1: Solid Concrete or Masonry 700 0.0 11.0 46 Wall height: 5.0' Depth below grade:4.0' Insulation depth: 5.0' Furnace 1:Forced Hot Air,90 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.6 Release 1 (formerly MECchecl and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer" - REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.6 Release 1 DATE: 12/13/04 PROJECT TITLE: State Route 149 House Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Windows: [ ] 1. Window 1:Vinyl Frame:Double Pane with Low-E,U-factor: 0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: Doors: [ ] 1. Door 1: Solid,U-factor: 0.230 Comments: [ ] 2. Door 2: Glass,U-factor: 0.230 Comments: Crawl Space Walls: [ ] 1. Crawl 1: Solid Concrete or Masonry,5.0'ht14.0'bg/5.0'insul, R-11.0 continuous insulation Comments: Applies to walls of unventilated crawl spaces. Exteridr insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,90 AFUE or higher Make and Model Number Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type'IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g. (500 Pa). [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105°F or chilled fluids below 55 T must be insulated to the levels in Table 2. Table]: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HIVACPipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System ypes Range F 2"Runouts l" and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) i I have seen.or observed, or believe I saw evidence of, all objects such-as-Th-uses, wells, trees, fences etc,,, �' t SETT �r1c=�r; i this document, l a so represent that leave personally measured the distances'set forth on the diagram." 1 NA .c ON i sy�9 I.F.F 5:.M6S O J 0 o t)' r 0 0 j I/1 1NGLE Stto�r ropes P��.� 9. 'Fovpo iv R+, $2 Row fouvo S�1'11 � /� �M a Z23.11" s-r.wEs LESI�rc Tar-fCESA 0 'd' �•4-8 A- A- l � DtM\Glt W KA1tL M ' 0 NOE2Sd�s • , J.zG�A-! f tQ �oH� �ENpa�c a oc•r. 21 154-7 Z57-4SIJ i Jo P,4,,- AF F KE`( o �vuF 15 1548 -.. . i 2G S-46S $o.cA�►Es Zt. Ac L.T Zau e V1 Roo ! / S 3v•w oo' 2• :; • u •2 vim.• ,; �c- ^,J° 5.85'z8•`'' S.BZ'-3'3'..._..- `=---•-' _ __ .. �� �; _ cTO A� s. 191.