Loading...
2004-957 1, TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20040957 Date Issued: Tuesday, September 27, 2005 This is to certify that work requested to be done as shown by Permit Number P20040957 has been completed. Tax Map Number. 523400-301-005-0001-065-000-0000 Location: 46 NOBLE Way Owner: WILLIAM KILBURN Applicant: PROVIDENT DESIGN &BUILD LLC This structure maybe occupied as a: " Fireplace By Order of Town Board Garage - 2 Cars Attached TOWN OF QUEENSBURY Single Family Dwelling Issuance of this Certificate of Occupancy DOES NOT relieve the / property owner of the responsibility for compliance with Site Plan, �[ Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040957 Application Number: A20040957 Tax Map No: 523400-301-005-0001-065-000-0000 Permission is hereby granted to: PROVTDFNT DF,STCTN&BT TfT,D T,T,C For property located at: 46 NOBLE Way in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: THE BH GROUP, INC 467 ALBANY-SHAKER Rd GaragFireplace . LOUDONVILLE NY 12211-0000 Single Family d -2 Cars Attached Single $200,000.00 Total Value $200,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency PROVIDENT DESIGN&BUILD LLC 3 TALLOWWOOD Dr CLTFTON PARK_ NY 12065-0000 Plans&Specifications 2004-957 LOT 14 House No. 46 NOBLE WAY 2676 SQ FT SINGLE FAMILY DWELLING $368.62 PERMIT FEE PAID -THIS PERMIT EXPIRES: Tuesday, February 07, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at tl o of Qu e sb ry; onday, February 07, 2005 SIGNED BY 1 for the Town of Queensbury. IV- Director of Building&Code Enforcement Building Permit Application. RECE Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury,NY (518)761.8256 DEC 1 0 2004 i A permit must be obtained before beginning construction. Permit File No. RVV E QUE NSB URY �+zvING AN No inspection will be made until applicant has received a Foo p�d $ CODE valid building permit. All applicants' spaces on this Roc.Fee Paid $r application must be completed and must appear on the Reviewed By: -►� O�' o� application form. Applicant: vs �S�' A Owner: Address: W�o �? Address: Phone#(�) - q7// Phone 0(-177) --?R- q 7/I Property Location': Lot Number: / House Number , Subdivision Name: Tax Map Number. 30t, V New Building: residence /commercial 'Estimated Market Value of Construction: S id °- o Addition: residence/ commercial if an Addition,what will use of new addition be? i C Alteration: residence/ commercial :a No change to exterior size: residence/com'1 ;o Otherwbrk(describe ) Check OccuponcyWormation 1 Floor 2° Floor Other floor Total Below, sq.ft. sq.ft. sq.ft, Square Feet Single fizily dwellin 2 Z o Two family dwellin o Townhouse o Multifamily dwelling #of units o Office o Mercantile o Maaufactutia O 1 oar detached ge a 2 car detached Rme 0 3 car detached garage _ O 1 car attached garago I o 2 car aMahed Sarago 7 7 O 3 car ached g2mge o Storage building- commercial v Storage building- residential o Other What its the proposed height of the structure feet inches Will any second-hand or ungraded lumber be used? If so,for what? /1 Type of Heating System: electric/ oil J 94' /wood forced hot air/ 'aseboard/other: Number of Firenlages to be installed Number of Woodstoves to be installed Listbelow the person(s)responsible for supervision of work as regards to building codes: Name -`- :---..�Address, -- Phone Number Builder z / k► dJ d Z/7L Plumber Ip 2 i iMason (Electrician t4claration; please'sign below after you have carefully read the statement: To the best of my lmowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Vwo shall submit,prior to a Certificate of Occupancy or rtlficate of Compliance being issued,as requestedby the Zoning Administrator or e 'r of 6 din and Lot., s Bradt Survey by a licensed surveyor;drawn to scale,showing actual location of all no Signature: ilowner,owner's agent,architect,contractor Check Residential Plan Review: One&Two Family Dwellings Y/N/N/A VT�Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans:90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofing/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6"Drop in 10'Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where "e uired Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise ' Winder Run and Rise t' Spiral Not Allowed From 2d Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results,if required Septic To Well Or Water Line Separation All Paperwork Signed Project Name: /1 Adl- _`C C� ZP� � - / � Addres rI(.�'� bZ1//C EC EIVED .Building Pemut Subinission SFD DEC 1 0 2004 Checklist 2-Fam4 TOWN OF QUEENSBUR BUILDING AND CODE Y - All iterm belowrnust be checked either yes,no ornot applicable prior to submission of any budding. permit to the Town of QueeAsburyBw7dingDepaitment If anyof the below items are hchig,the per mit- wM not be accepted until such rice as the application is deemed complete for subnvssion. 1. Budding Permit Application Completed ..................................... ❑no ❑n/a 2� EneWFomn or CheckMate EnexgyCode Compliance Form Complete.. C Eyes ❑no (2 copies) ❑ Energy Code Lupector's Report from C�reckMate Program..... tVJ)� no ❑n/a - (2 copies) 4_ Septic application complewlyf"out(if applicable)........................ dyes 0 no ❑n/a S. Solid Fuel Burning or Gas Appliance Form_.. 15.................................. yes Ono n/a 6. Electrical Inspection Form....................................................... Eg3 Ono On/a 7. Two(2)complete sets of structural drawings....................................dyes Ono On/a a) floor plan;b)foundation plan;c)cross sections:d)elevations; e)window and door schedule &. Two(2)site plans showing location of'the structure to be built,_........... ayes Ono fjt fa location of well or water lines,location of septic system or sewer line. 9. Setbacks frompropertylines to new structure........................... ..... [ Yes Ono ❑n/a 10. Setbacks to neighboring wells and septic system,including onsite well_... [ yes Ono On/a and septic system(if applicable) 11. DrivewayPemut..................... ......................... . ................. Ulm Ono On/a Date: Staff InitiaL- Job Site Address: t' Date: Owner:��e �i,S�� �; � ��<<< Application No. QL��-r'15 File 1 w Building Permit — Calculation. Sheet DEC 1 0 2004 Natural Light, Ventilation & Emergency Egress RequirernWgLDIN�AND CODE . Habitable Area of Req.Light Actual. Req.Vent .Actual Sq.Ft. Remarks Room Room 8%of Room Light 4%of Room Vent Opening for in Area Square Area Square Egress Square Footage Footage Feet 914, -7 6 ve2 70 13 7, 36 yd S. 7a ,� 5z hod I � 3i .s� ld. s`z � .�' L:\SueHemingway\Building.Permit.FORMS\Nat.Light.V entil.Galculation.Sheet.doe WINDOW SCHE,DUL l o ld �� Job Site/Addres � . Date: /� / �� f� .. Owner: 12.�.�., 4 %�ar ZL'C Application No. .:2o Window Window Window Unit or Rough Rough SQ.FT. SQ.FT SQ.FT. Clear Clear Special Hardware Number or Manufaturor Model/Type Stock Openin Opening Glass/Vis Egress/Cle Opening Opening or Instructions Letter on Name jd54 Numbe g Height ible Vent ar Width In Height Plan Call Width Light Opening Inches In Inches J/ -f Size / 3!?'7 11�erS'ei 31�7 �cS� 31011 % C"1/� Sr��" ljy �� Z. $�i S: 33 C7�� �/�fSLti .3 0 '5�0 ,je�77 3i0 �f �r0 ` �1� = �� �El lQ `3 t� -72. SU' `ls'U ►G�,s� 2-v56 rD,r 747 yes V. 5�;- 5'61- 7,> Sc)_?6" Dt'z.5'�C� 30 ��F' �-u� �'fj r r 3;� it r D � � r -rSz�► 7.6r� � b � 6 ! � af.gz 24 .33 314 .73 (nr/ �� 7� /a. h�aGJ Example Entry A Andersen Narroline 3062 3' 2 6'5 '/z 15.30 8.36 6.01 34 24 15/35" Tempered Double 1/3" 11/16 Glazing Hun RO'ECEIVED CADocuments and Settings\.Sue\L.ocal Settings\Temp\Window Schedule.doc DEC 1 0 2004 TOWN OF QUEENSBURY BUILDING AND CODE l F ` c) ENERGY CODE COMPLIANCE APPLICATION TOWN OF QUEENSBURY, WARREN COUNTY 9000 HEATING DEGREE DAYS Der Tb�(A, 1 0 2004 Compliance Methods:Part 5 -Acceptable llings(only) Part 6*-Thermal Rating tlCoce mponent trade Family ff&2 Family Dwelling; U�����GQp�SeUR Multi-Family Dwellings(3 Stories or less) Part 4*-Design by Component Performance,Commercial Buildings-Hi Rise Residential *Requires submission of worksheets APPLICANT'S NAME: PROPERTY LOCATION: PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE: 1. Gross Floor Area 2� 7 square feet ' Gas 2. Type of heat- Electric Other c - 3. Is building mechanically cooled? yes No 4. Percentage of area of windows and doors Over 17% Under 17% 5. R-VALUES FORMULATION GIVEN BELOW MUST CORRESPOND TO&VALUES AS. , SHOWN ON PLANS SUBMITTED: a: Roof R3� b. Exterior walls R C. Glazed areas R`G�� d. Exterior doors R e. Floors over unheated spaces R. f. Edge of slab on grade(heated building) R g. Basement/collar walls(above grade) R /f h. Basement/collar walls(below grade) R i. Heating/cooling-ducts-piping in unheated space R ®� 6. Service(domestic)hot water heating device Conforms to minimum efficiency per code Yes No TEMPERATURE CONTROL MAXIMUM SETTING 140—WILL NOT BE EXEEDED Ap 1' ant' gna a Dat Phone Number INSPECTOR'S REMARKS: t Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY (518)761-8205 Application for Fuel Burning Appliances & Chimneys applicable to solid fuel & vented gas appliances Date �/ , 20 d ` Permit No. i Application is hereby made to the Building do Codes Office for the issuance of a B n •l Permit pursuant to the New York State Fire Prevention and Building Code. The applicant or owner V ED agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are, cttoof these requirements and also will allow all inspectors to enter prernises to pe,form required inspe . rows Qu NOTE to applicant: Rough-in and Final Inspections are re _ A,vp�oQE y Applicant Information Fuel Burning Appliance Information (circle appropriate words) Name:/ n�����+ 7� �r'r4 Utc ��� C Stove: wood coal pellet 7n� Fireplace insert Address: 3 !�. 1/0��w,X Jr Fireplace, factory-built: wood �/j' l2�,�S Fireplace, masonry: wood gas Furnace: wood gas oil Phone: 3 97 1 1 If non-masonary applicance, please provide Owner: Manufacturer Name: ZZO-f-,41- Address: ��� °a� P�,� .Model Number: 75 a S�- C/,� Chimney Information Phone: ' 8 ` S(7 (circle appropriate words) Masonry block brick stone Flue the st p size: CjP inches Exact Address: � �6/c �f� • of onstrucd n or insl llation Factory-Built L ��/ t- Manufacturer naive: Model Number:75�03L Note:. G 1" Listed By: Number: Construction/Installation must conform to NYS Fire Prevention &Building Indicate(circle)chimney material: Code. Consult available Town of Queensbury =irect Handouts regarding required inspections. Do,zz�/ Triple wall / Insulated Chimney Liner C7a.racl:fer',�r�3ep�x�m�t—To�rsat o.P Que�a,e�bz�*y, ,ZV'e�r Yorl� Fire Marshal Code# $Collected $Refunded Received from(refunded to): . Vl�� ` C� address; A 173 3389 (190) Public Safety J A 233 2655 (230)Min r Sa s DATE: White(Applicant) / Green(Fire Marshal) / Yellow(Bldg.Dept.) / Pink&Goldenrod(Cashier's Dept.) Fire Marshal's Office Town of Queensbwy,742 Bay Road,Queensbury,NY (518)761-8205 Application for Fuel Burning Appliances & Chimneys applicable to solid fuel & vented gas appliances Date �'1 20 U Y 'Permit No. �S Application is hereby made to the Building_& Codes Of face.for the issuance of a Building and Use Permit pursuant to the New York State Fire Prevention and Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to per form required inspections. NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information ' ' § °°°� Fuel Burning Appliance Information (circle appropriate words) Name: f t"t� t' r� r A( ;'�e�1 � � `Stove:: 47,� ,, Wbad, coal pellet �'gcrs Fireplace insert Address: .a !cl� (/0 e'wVa If :a"/ i t'111F repllace, factory-built wood g r l lr.kFireplace, masonry: wood gas Furnace:`' ir'J wood gas oil Phone: 13 a v `ifnonzmasonary applicance,please provide Owner: V,�k Manufacturer Name: / r � ' Address: ? l` t� w� '°�'°®a `- Model Number: Chimney Information Phone: 3 0 t,Y 7 l (circle appropriate words) Masonry block brick stone Flue tile('steel' size: inches Exact Address: `�' /'� ✓� of construction or.ir sta'llation Factory-Built (l Manufacturer name: w� -���-' �/� ` � Model Number:, o Z.. Note Listed By: Number: Construction/Installation must conform to NYS Fire Prevention &Building fndicate(circle) chimney material: Code. Consult available Town of Queensbury � Handouts regarding required inspections. �Double_wall`% Triple wall / lasulated / Dh ect venlrng= Chimney Liner- Casrlatfex-',or pxLrtzM®jxt—Z'e»rs2. of Qaxaen,Wbzzxy, 1V"4--xW W,46-r-A Fire Marshal Code# $ Collected S Refunded Received front (refunded to):T;, 7� address: A 173 3389 (190) Public Safety C � _ A 233 2655 (230)Minor Sales _ Ir' i•. � DATE: jf !tP White(Applicant) / Green(Fire Marshal) / Yellow(Bldg,Dept.) . / Rink&:Goldenrod(Cashier's Dept.)- Application for Permit;-S.Optic Disposal System Town of Queenmbur y 742 Bay Road Queensbury,NY 12SO4 (518) 761-82S6 1. OWNER INFORMATION- -., ........................................:.........- ....,,.,..,...........................,....-...... ��// / ! Office Use Location of in lallatlon: �d File Permit No. 9 �. Fee Paid Owner's Name: �r�U '�e�. �- r�S �{ ��� -.-.-............................. ,...,..,,.., Address: 2. INSTALLER'S NAME : PHONE NO.3, RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply #of bedrooms with applicable gallons per bedroom to equal total daily flow) EC 1 0 2004 Year of House: No. of Bedrooms _N Qmy to gn = Total Dgily Flow TOWN OF sUIWIN�U FENSBURY 1980 or older x 150 gal/bdrm = ND CODE 1980—1991 x 130 gal/bdrm = _ 91— es x 110 gal/bdrm Garbage Grinder Installed yes_, / no Spa or Hot Tub Installed yes_ ./ no 4: PARCEL INFORMATION: (circle applicable information&indicate measurements) Soil Nature Ground Water Bedro;kMaterial la and at w . depth at what th munieipa oiling loam a eet feet Steep slope clay tf well;water supply !%slope other t c.cv'� ec�'` $'� from any septic-system depth, absorption Is ft. other PercolationTest: (To be completed by.licensed professional engineer or architect) Rate: n c'sw-minute per inch S. PROPOSED SYSTEM: For Now Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision), Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank- /� �© gallon(min. size 1,000 gal;) Tile Field: each trench C) ft. Total System Length: Seepage Pit(s): number of size of each. eft. by fit; Size of Stone to be used: # — / depth or thickness feet Bed/System Size: U / x © t Alternative System: length andlor size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons -- - - -- Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of th of u bu tary Sewage Disposal Ordinance, Signature of responsible person Date 11• A • 5rtvc:r:t 1111ZI Sawil e i>-Aposal tiirtioto. Nm t ' SI:I'11Ii.1�,'I'xtl)�l_ t�Ir4Zt•J'(ItTrl�]t�Il�l•'1`:► . r , POND b'l�.u. tH trhtf'�• .: Gt u•nre . WX • •tlt�itY CliS`I+ll'� x Cz• wry r� X • "ell • � � � j r' ' , Sc t►t tG I� �.....�. ` �,,w' ��� 4 �yt1!►itttJ:s111�•t t • • 1+Zy�RO't11c.1 i irilit� � ' r , r 7• SIC#1�IA."I.~t3 &ngroRIYSA'J.°Yoli vor,'mr6ioxour� r:�w�•;��+,�r •,•••,•••:;" '' ' •t' r Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: —am/p epart: P Date Inspection request received: _ _ Inspector's Initials: NAME: PROUf�_ /11 /' 12- 16A) PERMIT#: © — 4 LOCATION: ,h1,,Y !��! DATE: TYPE OF STRUCTURE �— Comments V N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more a7,stairs, decks patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %Z" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tern 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window M Plumbing fixtures Foundation insulation 7 Floor truss,draft stopping finished basement 1,000 sf �C(�(,.b bt1 S CJ Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft. vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan 07 As Built Septic System/Sewer Dept.Inspection Sticker N Flood Plain Certification, if required 7Z— Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 i Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ art: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: q 6-7 NAME: o(�11eil PERMIT NO.: 0 1 LOCATION: 6 6 1,4 INSPECT ON: RECHECK: Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: $. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/Pit Opening Sealed: Y/N/Partial End Caps Location/Separations Foundation to tank Foundation to absorption ft. Separation of Pits Conforms as per Plot Plan — N Engineer Report and As-Built Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Statu �ef� proved artial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved Last revised 116105 BOSWELLENGINEERING ENGINEERS■SURVEYORS■PLANNERS■SCIENTISTS EST. 1924 799 Madison Avenue•Albany,N.Y. 12208•(518)436-6310•Fax(518)436-0859 TOWN OF QyEENSEURY COMMUNITY DEVELOPMENT VIA FACSIMILE RECEIVED (518) 745-4437 SEP 8..2005 F A R E September 27, 200�&C ZONING_ FM PLANNIN Town of Queensbury Building Department EXEC.DIR._�_ 742 Bay Road Queensbury,NY 12804 Re: Septic System Installation Lot 14 Noble Way Kings Court Subdivision T/O Queensbury, Warren County,NY Our File No.: A02-008-05 To Whom It May Concern: 04"- Y �) Based upon a visual inspection conducted by our office on September 26, 2005, we hereby attest to the,fact that the septic system has been installed for Lot 14 —Noble Way. The septic system appears to have been installed in the relative location shown on the approved plans and appears to be installed in general conformance with the NYSDOH approved plans (plans entitled `Kings Court Subdivision - Final Plans', dated October 15, 2003; last revised: April 7, 2004, with a NYSDOH approval date of May 17, 2004). Should you have any questions, or require any additional information, please feel free to contact our office at(518) 436-6310. Very t 91W Yo B G 9 Br '° P� cc: Ms. Anita Gabalski,NYSDOH, 77 Mohican 8f.,'Glens Falls NY 12801 BDB/EJH/ejh X:\WEST MOUNTAIN\BLDG DEPT SEPTIC CERT LETTER 092705 LOT 14 NOBLE WAY.DOC Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: 9 1 Z �ietsUCG,i�iv NAME: f/ LOCATION: a`i" �`1 NDW Uj PERMIT#: Zd� _ 5� Final Survey Plot Plan Approved Denied The attached final survey has been received by the Dept. of Community Development. Upon review the survey has been• Craig Brown, oning Administrator Notes: LASueHemingwayTuilding.Codes.Inspection.FORMSTinal Survey Zoning Administrator.doc Y a p W r^ F-. V, p ►') W -I-, O Z W li m • Gr'Npz pN _ p, J z �- • • Q Z kty LI_ V.) D oo p O N - r- 7 Z W"w 21.0' p Z ZOZOp y.. W 'm F- b 21.2' w -1p0ln� J m� w / 11.8' N a�W Y to �6Z ; _I^ / O W J W Q U)W 2 V/ / W W pmJU: N O I ��W norm a �o m< R,275 00 N�3 29 23 E _ M O N � Q o z O Z o .5� 53.11' No= " �o �omU< v� `n �O 5� ND p�wWf- N�Z ilk.1 cz,i w Lri 0:W- ¢ -aZ m7la� 3 Z 26.5' moo W Wzw�1 � Y II o 0 12.5' ►Wi.WOa= d O < I LIJ Lri 15.0' c W a i--O F 0 3 4p (J moa ?" L6 m Q o /(Q iW c / m z O \ /Q N = o a M H to to 2 STORY /" ! WOOD FRAMES �N HOUSE o` / ram. 00 r W H-d #.9.y/ p (= t z Y tL Z N = O O Ow Q OD NSa� f•- OQ �_- Q Z } S � O /� / J o � 0OooZ az � Q< a ~ Nz� vzoiOQiaW-i wn w � (J/ W U ^ NO a00 Plw Li z Q X Lr F-•� \\ � V / o-.W3Nz >- oa awWD >-m - oaF- -' ocno w '* \� 0z O p \ �Q / NzmU � O Ir 5 Ln Z m > OOQ WW W z�. ZQ -� cc��Q \ �- -{� / /M � U = O � Q ENO o NO � � wincnx ' O . F�--1 m •9n \ 0 � N 0 � '- way oa } V)im� 0L)iCo w'zMZnz Q+ = Q s \ Q O J Z O /l O // i� Qa �v� °NOD zNZ 7: ioaJ=z -j as � a N } � � mw < oo� `` o0 pwV zOaZ02co z Y z cp � ,\ / a w3aaoQ Qwc, �``'o aa � in~ `'' � � oN Iw�.�r.Io i[5,] 0 O � m In = SU > o a > U �_ Ncn -,QZoa � c� W y r o oo.('t� 0 z Er W d' ~ VI W O N (� V) w z 0 0 W j a (+- O W Z F�-ii O `J \ \ w z N a w o Z z U z O z o 0 m O a a z a 0 z z Ov O �i z O Of / ^ 3N�1N0( \ z � a wa: p � w � � avo-i wa ¢ waJw � cn �� o a rn rrSer/g.� Oby� �� s3� 1 �\ � m � No dU� Fin � � > � _' = awooJ3zw F � rr0 �S OZ N3W cr Y O (A0 � r Ztn Woo wN U_ Wt,. J QS F U (A o amwo > �tnm � � o oawo = w � pOt~if Qwc JYYQ 3a � w � v_' Qazcn � w � Za � a �'itL)� � Z c�wa c� w Q zw � � F z aU_ 4 O cn3Uc3N , Nf NNN / ~ O U1 m� OOOw Ot` NJO W J Z O > Woo NJ LLJJtA Z H !- H / O r-- Z O 0 uj J Qtn NUI. F- QNU) Oa ^ D zw Q > n Q Q =FOZ O Z000 ZZ J F- ¢ U � = ~w Qw � UrxxOZ � t� � Umo U � W�- cep www Q Q Q 0U } W � M. = WwF' z0 C✓ QWL_ tn w � = � Zp Z DOD Q <M tri wNvwi � Um } Qau3 �Ozo-� NOQ � o ~ `' Z ¢ F" U In tLln w DOQ aZ W W Q zz � OW = 0E- w = 0 0 F- (nzwzm0 :50mNJOQtoUUHUWU3 !- Z- C9WQ N M O Z N M d tri to - Wd Cb 0 L g00ZI0U6'6Mpleuybtxol 800 ZOe\sdeyy lol!eul:j1800-ZOw00Z1Z r� I_ Town of Queensbury Fire Marshal 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace/Stove 11isiDectioU Re])ort Notice.New York State requires that all UL Listed,factory built appliances be installed according to th0an /and specifications contained in the:Installation Manual accompanying the appliance.No deviation from theacturer's instructions or sped cations is allowed. Permit# L� Schedule Inspection (�� �ZYme_________am pm anytime Inspector Name PRO U-G ' T (o Address /Vo 16Z— �OA'f Rough In Final Appliance Manufacturer Model# Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated -� Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chianney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-(off Valve Combustion Air Hearth Extension (if any) Mantel eight above f/p opening Witness Operation Tank Placement(if LP) White—BaildingDept. —^ ___ Yellow Coat er Mk—Fire Marshal Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/p epa l'�am/pm Date Inspection re q eceived: Inspector's Initials: _ L �— NAME: U ^_ t PERMIT#: LOCATION: DATE: TYPE OF STRUCTURE: COMMOINS Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Com lete Guard 30 in.or more cry stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. ,Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area.- Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/3/<hour fire door/door closer Duct work Seated properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in,x 30 in.(ht.)In accessible area yawl Spaces 18"x 24"access, 1 sq, ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Ago ��P n6U��Final Surve Plot PlanK As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent W L:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. form 2,docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/ m art: jbj/Danilpm P Date Inspection request received: _ Inspector's Initials: _� NAME: 11R, . -�it! r a. PERMIT#: LOCATION: DATE: TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %2" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18" above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tern 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fire roofin,/3�4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft,-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:1PamW\Building&Codes\Inst)ection FormslRes. Final Inst). form 2.docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection No.(518)761-8256 Arrive: am/pm Depart: pm --- e Inspection reques ived: Inspector's Initials: _ FME: 1 (� PERMIT#: 0 q 5,7_ .LOCATION: -p DATE: TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location. Fresh Air Intake 14, 3 inch Plumb Vent through roof minimum 6" 1/7 Roof Complete/Exterior Finish Com lete Guard 30 in,or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior.Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum ''/z" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above rade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater o eratin Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior rivac /trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safe glazing/Window in stairwells safetylzin AI(,e� , '���c-tc� 6c* 5 ,/ K Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window ol Plumbing fixtures p<< _ �jiN�C /,,16 %c�W4-T(f Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fire rooftnc,/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft,150 s . ft.vents Building No./Address isi le from road �i2od/r✓� �od5� ry� Final Electrical Q L� Site Plan /Varianc re red Final SurveyPlot Plant��i�i2�G As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O [Temporary/Permanent L:\PamW\Building&Codes\Inspection Forrns\Res, Final Insp, form 2.docLast printed 2/12/04 Town of Queensbury Fire Marshal 742 Day Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Facto Built Gas Fireplace/Stove fnmection HeRort Notice: New York State requires that all UL Listed,factory built appliances be installed according to the in ructio s and specifications contained in the Installation Manual accompanying the appliance.No deviation from the ma ufa urer°s instructions or specifications is allowed. Permit -Ci Schedule Inspection - Time_ _,_,_area pm anytime lnspec r Name 1 ��C� Address Rough In ]N�nal d V Appliance Manufacturer Model# Direct dent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated T Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension (if any) Mantel Height above f/p opening ,",^� / Witness Operation V�U X P A-V Ab Tanis Placement(if LP) White—Building Dept, — ��-� 'Yellow test er Pink—Fire Marshal ( b —1-2- Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: ` � am/p,' 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: 2 NAME: ,Q�U1/i� p e---S'i gl1I PERMIT #: L�— LOCATION: UI (a yrs-L-c INSPECT ON: S TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head 50 P.S.I for 15 minutes ulation / Residential Check/ Commercial Check "'Proper Vent Attic Vent Duct / Hot Water Piping Insulation Cam ` If required unheated spaces Combustion Air Supply for Furnace _ Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Septic Inspection Deport Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: "� _ Lpm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: 7 NAME: G -4 — PERMIT N .: LOCATION: /..! f, ®� �J CC,f� INSPECT ON: — RECHECK: `" Comments and/or diagram Soil Type• and � Loam/Clay Type of Water: ici a' Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box t ield/Pit Opening Sealed: / /Partial End Caps Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y N Engineer Report and As-Built i Y N Location of System on Property: rout Rear Left Side Right Side VFront Rear S stem Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved Last revised 1/6/05 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart. arr/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: L ' ` NAME: PERMIT#: LOCATION: INSPECT ON: _ TYPE OF STRUCTURE: ng :�Y N N/A COMMENTS tg�,Q fy"', mi Attic Access 2"x A"minimum Jack Studs/Headers / Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 I/2 w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above I below grade 5.0 sf grade #y a S; '9.', Rough Plumbing / Insulation Inspection Report` Office No. (518) 761-8256 Date Inspection request received: 036-10 5 Queensbury Building & Code Enforcement Arrive: am/pm art: 1 m m 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: �nv1 r '� � ?�� PERMIT #: LOCATION: /lb-bl'e INSPECT ON: ? r 05 ,� TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head r 5 P.S.I. or 10 ft. above hi Kest connection for 15 minutes Pressure Test / Water Supply Piping Air/ Head 5DLP-5...Lfor 15 minutes Insulation esidential Check / Commercial Check er Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report-revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart:�0- 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: �' J NAME: PERMIT #: u �S7 LOCATION: L C �_(°��,�n1-e L Da�, INSPECT ON: 5 TYPE OF STRUCTURE: Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping �� w Air/ Head 50,1P.S.I for 15 minutes 'vIrisulation / Residential Check/ Commercial Check Proper Vent Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&CodesUnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: z� as Queensbury Building&Code Enforcement Arrive: am/ &epart: n/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: JPT c1y i G�� I>� �GJ� PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS * raining',. Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour ire"stopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 0 sf grade Framing Firestopping Inspection Report Iq 9 / - request received: `"l Office No. (518) 761 8256 Date Inspection q / Queensbury Building&Code Enforcement Arrive: am/p epart: am/pm _ 77 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: \ o, NAME: C7 V\ 1 Qlj JL)e,5j CN—,--, PERMIT#: LOCATION: INSPECT ON: -- TYPE OF STRUCTURE: i Y N N/A COMMENTS raming Attic Access 22"x 30"minimum � �r1�LLy�/�LC Jack Studs/Headers b ►k&00 A-L b3c_js Bracing/Bridging _ ! �jQ��� Joist hangers O W— (Z U 4 zi Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %a(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall.2, 3,4 hour restopping. Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 'V2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade W- 6tgh Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: �IIAP� Queensbury Building &Code Enforcement Arrive: am/ply .Depart• / am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: 1 NAME: '�q 1�T ► PERMIT #: Ov — ��? LOCATION: 4(0 ovs L-- Lk)n2:2-- INSPECT ON: 22-7- b TYPE OF STRUCTURE: Cum Y N N/A Rough Plumbing Nail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum CI out every 100 feet/ change of direction "Pressure Test 1=Lte Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam WhitinglBuilding&CodesVnspeetion Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: _arn/p D part: J�_am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's InitialsA r1 NAME: PC,b V"ICJG! C-, ((v f PERMIT#: qr LOCATION: INSPECT ON: TYPE OF STRUCTU y Y N N/A F am,i„g _ C®1VIIm'IEhiTS Jack Studs/Headers ' Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate Q 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour /"Fire wall 2, 3, 4 hour c Fi es ppung _�. Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doe January 28,2003 9 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: - = Queensbury Building &Code Enforcement Arrive: am/ 0apart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: 5 NAME: 9-y ON ' e PERMIT #: ' LOCATION: N INSPECT ON: i TYPE OF STRUCTURE: Y N /A ao hFPlumbin" / Nail Plates `Piumbin 'Vent/ Vents in Place / VG�II 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction ressure.Test Drain / Vent Air/ Head 5_P.S.I. or 10 ft. above highest connection for 15 minutes Pr ss&6 lest Wat ply Piping Air/ 50 P. r 15 minutes Insulation Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly No duct tape COMMENTS: LAPam Whiting\Building&Codes\hWeetion Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005 Town of Queensbury Fire Marshal 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 F Ice/Stove Inspection Re nort Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. ' Permit# �-9 S.(-7 Schedule Inspection d-c��U Time ���pin anytime lnspecta; ` LName�j�S� Address_ ��n (��r��� ��-� � g Appliance Mantearer ��r�(f l �� Model# -D V �402A"a �� 0 53 1 M Direct Vent Flue Size Double Wall Triple Wall Insulated Yes No N/A) Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet alcove roof penetration;2 feet above any combustible construction within 10 feet Gals Shut-Off Valve Combustion Air Hearth Extension (if any) Mantel Height above f/p opening 'Fitness Operation Tank Placement(if LP) White—Building Dept. _----� 'Yellow CU-t er Phrk—Fire Marshal Framing / Firestopping Inspection Report ✓(� Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ LpWart: 0 am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials. NAME: r "A PERMIT#: .� LOCATION: INSPECT ON: TYPE OF STRUCTURE. zFr' n g Y N N/A COMMENT' pp Attic Access 22"x 30"minimum P/`D l/ (ff � Jack Studs/Headers Bracing/Bridging !7P Joist hangersj��✓—�'(1` Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z(w) 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour ,F oppmg �GL Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side ''/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/ f Depart: am/prrl 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: ( NAME: f�. - ' ' j�� PERMIT #: D LOCATION: Acc- a INSPECT ON: 6, b, 5 TYPE OF STRUCTURE: Y N N/A 1 Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size /Washing Machine Drain 2 inch minimum /Cleanout every 100 feet / change of direction Pressure Test JDrain / Vent Air / Head l 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping I Air / Head 50 P.S.I for 15 minutes Insulation / Residential Check / Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: _ Queensbury Building&Code Enforcement Arrive: am/p Depart: 1. ' am/ m 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: � � ��/v PERMIT#: LOCATION: INSPECT ON: j l ' 6 TYPE OF STRUCT RE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging i Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall ' Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.In spec tion.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: C- {3 dbJ Queensbury Building&Code Enforcement Arrive: arn/pr Depart: I!�' a pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: r NAME: s1 C=V►A PERMIT#: Zoo 4-q5 7 LOCATION: )Ito J 06Lr- LU w-In_ INSPECT ON: S & TYPE OF STRUCTURE: ' 11 Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. 4b� Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center / 1 ce and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report / Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/ Dep rt: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: 1�b _ PERMIT#: LOCATIO INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Ma ialsfor-tits^pu Boa e on site. oundation/Wallpour enforcement in Place Foundation Damp-proofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab _ ' Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. I:ASueHemingway\Building.Codes.InspcctionTORMSToundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/ Depart: nv`pm 742 Bay Rd., Queensbury, NY 12804 Nbl-e—� Inspector's Initials. NAME: !�'f f Cif[�G� PERMIT#: +�C ( � LOCATION: U ` INSPECT ON: f 5 TYPE OF STRUCTURE: t tL `�/� 5 ��✓7 C:�` � ommeuts Y IN NT/A cJ//� l 1 Footings FY5' (/� Monolithic Slab Reinforcement in Place The contractor is responbl or providing protection from freezi for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Bui]ding.Codes.Inspection.FURMSToundation Inspection Report.doc January 28,2003 An t oz/ Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoflware Version 3.5 Release Ic Data filename:C:\Program Files\Check\UScheck\Westminster.rck TITLE:The"Westminster",#14 Noble Way,Town of Queensbury RECEIVE 1,/ � -DEC 10 2004 COUNTY:warren `�' �!`� STATE:New York TOWN OF QUEENSBURY HDD:7635 �' BUILDING AND CODE CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE: 11/08/04 DATE OF PLANS:November 8,2004 PROJECT INFORMATION: The"Westminster",#14 Noble Way,Town of Queensbury COMPANY INFORMATION: Provident Design&Build,LLC COMPLIANCE:Passes Maximum UA=640 Your Home UA=503 21.4%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 1603 30.0 0.0 56 Wall 1:Wood Frame, 16"o.c. 3326 19.0 0.0 173 Window 1:Vinyl Frame:Double Pane 369 0.350 129 Door 1:Solid 40 0.320 13 Door 2:Glass 40 0.350 14 Basement Wall 1:Solid Concrete or Masonry 1442 11.0 0.0 101 Wall height:7.8' Depth below grade:5.8' Insulation depth:7.8' Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 404 24.0 0.0 16 Floor 2:All-Wood Joist/Truss:Over Outside Air 16 24.0 0.0 1 Fumace 1:Forced Hot Air,90 AFUE �E OF N Air Conditioner 1:Electric Central Air,10 SEER 1� Gj td ED ftr 0 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the p specifications,and other calculations submitted with this permit application. The proposed systems have b sign New York State Energy Conservation Construction Code requirements. When a Registered Design Profes i h signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,s.k antis r, specifications are in compliance with this Code. T REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release Ic DATE: 11/08/04 TITLE:The"Westminster",#14 Noble Way,Town of Queensbury Bldg. Dept. Use I Ceilings: [ ] I 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: I Above-Grade Walls: [ ] I 1. Wall 1:Wood Frame, 16"o.c.,R 19.0 cavity insulation Comments: I Basement Walls: [ ] I 1. Basement Wall 1:Solid Concrete or Masonry,7.8'ht/5.8'bg17.8'insul, R-11.0 cavity insulation Comments: I Windows: [ ] I 1. Window 1:Vinyl Frame:Double Pane,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: I Doors: [ ] I 1. Door 1:Solid,U-factor:0.320 Comments: [ ] I 2. Door 2:Glass,U-factor:0.350 Comments: I Floors: [ ] I 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-24.0 cavity insulation Comments: [ ] I 2. Floor 2:All-Wood Joist/Truss:Over Outside Air,R-24.0 cavity insulation Comments: I Beating and Cooling Equipment: [ ] I 1. Furnace 1:Forced Hot Air,90 AFUE or higher Make and Model Number [ ] I 2. Air Conditioner 1:Electric Central Air,10 SEER or higher Make and Model Number I Air Leakage: j ] I Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly I with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. I Vapor Retarder: [ ] I Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. I Materials Identification: [ I I Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] I Materials and equipment must be identified so that compliance can be determined. [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] I Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. I Duct Insulation: [ ] I Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] I Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] I Supply ducts in unconditioned spaces must be insulated to R 11. [ ] I Return ducts in unconditioned spaces(except basements)must be insulated to R 2. Insulation is not required on return ducts in basements. I Duct Construction: [ l I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ I I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ I I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system [ ) I The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. I Electric Systems: [ ] I Separate electric meters are required for each dwelling unit. I Fireplaces: [ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] I Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. I Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1, I Swimming Pools: [ I I All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. I Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. iY Table 1: lrInimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25' 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness forHVACPipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) X ir O olIK5 F S W O Zn m3o > o o W wN Q Z < G p LL NQ�:-o 0 In Z C EWZM p ow— I _ d WaW� L LLJ 0 W Q l�Z m LLB z ; 2 0 0 Q w 0 �� (A C, N li Q� m i `; _ 75 p0 NO3'29'23"E Y W z e o « :ve : �� R.2 _ _ _ w o- 0 f Z c 53.11' cwmcZ—� e d' U `F ALi • ✓eiC/trot O , '/� ��++..�� Z .�.� J _ P OPO D SEP71C w a W cn ~ Y a:aaoo O < I W 0. 3 J LL. } { /\ 0 com U 0 � c ry /Q SEC l � o / �.\ 21.0 11 8. 21.2 //� ej" °F o PROPOSED ' n O���� V �( , M N 20\%J n HOUSE /o �C'9�F `5'�'(/ •t FF=103.5 6,000 F� 15.0' o 06. co 0' 1-1 l� ID O J f- wN � U z 10 co o ,,lam o M N x >0 / N r00S� _ � 3 U) m ��++_ w M rrJ�r� IIV s.}� _V�b81s321 Z W r Z / `s �Z 39 N�b 3Sb3 co 0 Wb'6L:tt:tL b(IwlaL '5mpkt-101 9oo-zmsupl lolfto0-