Signed Inspection Report (Wed Aug 11, 2021 at 953 AM)INSPECTION WORKSHEET (RPLUM-012626-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0509-2021 Case Module:Permit
Inspection Date:Wed Aug 11, 2021 Inspection Status:Partial Pass
Inspector:Smith, Mark Inspection Type:Rough Plumbing
Job Address:Parcel Number:22 PARK VIEW AVE
Queensbury, NY, 12804
302.14-3-62
Contact Type Company Name Name
Primary Owner Stecuik, Julia
Contractor Hilltop Construction
Applicant Hilltop Construction
Granted Permission Stecuik, Julia
Checklist Item Status
Permit Card Visible From Road Failed
Building Inspector Notes Failed
7/22/21 partial approval for rough plumbing, sanitary plumbing under slab for floor drain at ice maker, washing
machine and sink approved. Sanitary plumbing tested with water head test, holding pressure for 15 minutes,
bathroom and tub area not completed at this time. Supply piping for washing machine toilet and laundry sink
charged at inspection. 8/3/21 verified remainder of PVC under slab for shower, soaking tub, and vanity, lines
holding water.
8/11/21 remainder of plumbing above slab approved
Plumbing Vent Vents in Place Passed
Tied into existing vent stack
3" Vent Through Roof Passed
Existing
Aug 11, 2021 Page (1)
INSPECTION WORKSHEET (RPLUM-012626-2021)
Checklist Item Status
Shower liner test (2" of water)Failed
Pressure Test Failed
Drain Vent Failed
Air Head Failed
5 psi or 10 ft. above highest conn. for 15 minutes Passed
Plumbing under slab tested with water head test, holding pressure for 15 minutes
Remaining plumbing above slab for sanitary lines tested with water head test.
Pressure Test Failed
Water Supply Piping Passed
Supply plumbing charged at inspection
Air Head Failed
Air Test Gas Piping 10 psi for 10 Minutes Failed
All Return Air Hard Duct Work Failed
Duct Insulation - if required in unheated spaces Failed
Aug 11, 2021 Page (2)
INSPECTION WORKSHEET (RPLUM-012626-2021)
Checklist Item Status
Duct Testing Outside Conditioned Space Failed
Duct work sealed properly Failed
Aug 11, 2021 Page (3)
Smith, Mark