Loading...
2003-049 � TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20030049 Date Issued: Wednesday, May 07, 2003 This is to certify that work requested to.be done as shown by Permit Number P20030049 has been completed. Tax Map Number: 523400-297-013-0001-021-000-0000 Location: 195 CRONIN Rd Owner: FREIHOFER SALES COMPANY, INC. Applicant: FREIHOFER BAKING CO. This.structure may be occupied as a: By Order of Town Board Commercial Alteration TOWN OF QUEENSBURY Director of Building&Co e E ement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20030049 Application Number: A20030049 Tax Map No: 523400-297-013-0001-021-000-0000 Permission is hereby granted to: FRF,THOFF,R BAKING CO. For property located at: 195 CRONIN Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: FREIHOFER SALES COMPANY, I 55 PARADISE Ln Commercial Alteration 160,000.00 BAY SHORE,NY 11706 Total Value 160,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency PLANK CONSTRT JCTTON Plans&Specifications 2003-049 FREIHOFER BAKING CO. 5040 SQ FT COMMERCIAL INTERIOR ALTERATION AS PER APPLICATION $604.80 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,March 17, 2004 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.)' Dated at the Town of Queensbury; Monday,March 17,2003 SIGNED BY for the Town of Queensbury. ector o rBuil g d nforcement Building Permit Application Town of Queensbury Department of Community Development, 742 Bay Rd., Queensbury,NY 12804 (518) 761-8256 A permit must be obtained before beginning construction. Permit No.: J&Do �—oo No inspection will be made until applicant has received a Fee Paid: valid building permit. Form must be completed. Rec. Fee Paid: Reviewed By: Applicant: Owner: Plank LLC Freihofer Bakin Co. Address: Address: 388 Broadway , Suite B 1238 Albany Street Phone#: Sc enecta y, NY Phone#: chenectad NY 1230 Tax Map Number: a9 7,:0 j 1 OD( a ' Subdivision Name: F E R 2 5 2003 (if applicable) TOWN�NG AND CODEY Lot Number: /House Number: /Street Name gL11�9 OR ��� Propert y Location: 195 Cronin Road , Queensbury o New Building: Residential/Commercial Estimated Market Value of Construction:/ mac, ❑ Addition: Residential/Comme cial If an Addition,what will use of addition be? X Alteration: Residential ommercial t No change to Exterior size: Residential Commercial ❑ Other work: (describe Check Below Occupancy Info 1"floor sq.ft. 2° floor sq.ft. Other floor sq.ft. Total Sq.Ft. Single Family Dwelling Two Family Dwelling Townhouse Multifamily Dwelling #of units Office Mercantile Manufacturing 1 car detached garage 2 car detached garage 3 car detached garage 1 car attached garage 2 car attached garage 3 car attached garage Storage Bldg.,Comm. Storage Bldg.,Res. OtherX 40 A .lb Arj What is the proposed height of the structure: feet inches Will any second-hand or ungraded lumber be used? If so, for what? No No. of Fireplaces to be installed: 0 No. of Woodstoves to be installed: 0 List below the person(s)responsible for supervision of work in regards to Building Codes: Name Address Phone No. Builder Eric Vickerson Architect 2402 Parkville P1�.N ' skayuna 377 9697 Plumber None Mason Eric Vickerson Electrician ric Vickerson Declaration: Please sign below after you have carefully read the statement: "` c c � r3g4_5q� O To die best of my knowledge the statements contained in this application, together with the plans and specifications submitted, are a truc and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code, the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that Uwe shall submit, prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested 4yZoning Administrator or Director of Building and Codes, an As Built S ry by a license eyor; dale, showing actual location of all new construction. Signature: circle one: owner,owner's agent,architect, contractor) n Project Name: Freihofer Baking Co. BP# C Address: 195 Cronin Road, Queensbury, NY 12804 Building Permit Submission Mu1tO1&Dazfi ng & anm ial P246a; Checklist All items below must be checked either yes,no or not applicable prior to submission of any building permit to the Town of QueensburyBuilding Department. If any of the below items are lacking,the permit will not be accepted until such time as the application is deemed complete for submission. 1. Building Permit Application Completed... ... ... ... ... ... ... ... ... ... ... ... .. Vyes [:]no ❑n/a 2. EnergyForm or CheckMate Energy Code Compliance Fomis Complete... ❑yes ❑no Kn/a 3. Energy Code Inspector's Report from Checkmate Program... ... ... ... ... ❑yes ❑no gn/a 4. Septic application completely filled out(if applicable)... ... ... ... ... ... ... ❑yes [:]no Wn./a 5. Electrical Inspection Form... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... .. XTyes Ono ❑n/a 6. Two (2) sets of plans showing the following:... ... ... ye 6a. Floor plan(s)... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... Ryes ❑no ❑n/a 6b. Foundation plan... ...p ... ... ... ... ... ... ... ...... ... ... ... ... ... ... ... ... ..❑yes ❑no n/a 6c. Cross section(s)... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ❑Yes ❑no jKn/a 6d. Elevations ... ... ... ❑ye F]no ❑ 6e. Design loads including floor,snow load,and wind load... ... ❑yes ❑no Mn/a 6f. Seismic design(required after Jan. 1,2003)... ... ... ... ... ... ... ... ... ❑yes ❑no n/a 6g. Plans signed by registered architect or engineer,signed... ... ... . Myes Ono ❑n/a and sealed by a registered architect or engineer 6h. Window and door schedule... ... ... ... ... ... ... ... ... ... ... ... ... ... ❑yes Ono W'n/a 7. Two (2)site plans showing location of the structure to be built, ... ... ... ❑yes ❑no JAn/a location of well or water lines,location of septic system or sewer line with all setbacks and separation distances shown,and all improvements to the property. 8. Solid Fuel Burning or Gas Appliance Form(if applicable)... ... ... ... ... . Oyes Ono Xn/a 9. DrivewayPermit... ... ... ... ... ... ... ... ... ... ... ... ... ... ...... ... ... ... ... ... . ❑yes ❑no Nn/a Date: Staff Initial: L:\SueHemingway\Building.PemutFORMS\Generic Checklist.doc 1 DRAFT COPY (12/02/02) CHECKLIST NYS BUILDING CODE (BC) Building: ir NYS FIRE CODE (FC) NYS PLUMBING CODE (PC) Location: ��t NYS MECHANICAL CODE (MC) NYS FUEL GAS CODE (FGC) Date: 3 7U j NYS ENERGY CODE (ECC) Reviewer: Publication Date: May 2002 COMMERCIAL& MULTIPLE DWELLING OCCUPANCIES No. Topic Code Page Required Actual Section No. or Allowed 1 Jurisdiction:. BC-101.2 1 2 Flood Plain BC-1603.1.6 285 3 Separated or Non-Separated BC-302.3 18 Occupancies" 4 Occupancy BC-302 17 5 Type of Construction BC-Table 601 81 6 No. of Sleeping Units/Level BC-202 14 & No. of Units-Total 31 No. of Occupants BC-Table 1003.2.2.2 201 7 Covered Malls BC-402 33 W-Rise (75' Rule) BC-403 36 Atriums BC-404 37 8 Basement Definition BC-502.1 71 (See page 8 of this check list) Legend: NR = Not Required NS = Not Shown NA= Not Applicable CNN = Credit Not Needed Note: *Non-separated occupancies impose the most restrictive requirements JAM Pagel of 10 No. Topic Code Page Required Actual Section No. or Allowed 9. Heights& Building Areas Maximum Tabular Area BC-Table 503 72 �J�� Maximum Tabular Height BC-Table 503 72 Maximum Stories BC-Table 503 72 Mezzanines BC-505 73 10. Sprinkler System (water) BC-903 168 Basement Sprinkler BC-903.2.10.1 170 Water Source Sprinkler BC-903.3.5 172 Water Source Site FC-508.1 31 11. Frontage &Sprinkler Credits Area Modifications (ca/c.) BC-506 74 Height Modifications BC-504 73 12. Height&Area Summary Ht/Area H Area Tabular Area BC-Table 503 72 Frontage Credit BC-506 74 . Sprinkler Credit BC-506.3 75 Total Allowable Area Max Aggregate Area BC-503.3 -73 (Allowable Area/Flr. x No. of Stories up to 3 maximum) 13. Fire Apparatus Road . FC-503.1 29 (150' rule) 14. Exterior Walls Distance Separation* BC-Table 602 82 Exterior Wall Openings BC-Table 704.8 . 87 Parapets BC-704.11 88 Exterior Wall Coverings BC-Table 1405.2_ 257 Exterior Wall Finishes BC-Table 1406.2 261 Combustible * Distance separations are doubled if fire fighting water is not available (FC-508.1.3). NOTES; JAM Page 2 of 10 No. Topic Code Page Required Actual Section No. or Allowed 15. Fire Rated Construction Incidental Use Areas BC-Table 302.1.1 17 f`Krs�t Accessory Occupancy BC-302.2- 18 Mixed Occupancy BC-Table 302.3.3 19 Fire Walls BC-705 89 Fire Barrier BC-706 91 Shaft Enclosure BC-707 92 Fire Partition (Tenant*Sep.) BC-708 95 Smoke Barriers BC-709 . 96 Opening Protectives BC Table 714.2 101 Fire Blocking BC 716 107 Draft Stopping BC-716.3 108 16. Space Min. Rm. Dimensions BC-1207.1 251 Min. Ceiling Height BC-1207.2 251 17. Ventilation (Nat. or Mech.) -BC-1202.1 249 18. Light (Nat. or Mech.) BC-1204.1 250 .19. Exits One Exit Permitted BC Table1005.2.2 224 Stair Enclosure BC-1005.3.2 224 Emergency Egress BC-1009.1 235 Distance of Travel BC-Table 1004.2.4 220 wv 2cv' Corridor Width BC-1004.3.2.2 221 Capacity of Exits (calc:) BC-Table 1003.2.3 202 Corridor Wall Fire Rating BC-Tablel004.3.2.1 222 Corridor Dead End BC-1004.3.2.3 222 Door Width BC-1003.3.1.1 208 Door Swing BC-1003.3.1.2 208 Panic Hardware BC-1003.3.1.9 213 20. Stairs Riser BC-1003.3.3.3 213 7 Tread BC-1003.3.3.3 213 Width -- ----BC-1003.3:3.1 213 - ---- Headroom BC-1003.3.3.2 213 Vertical Rise BC-1003.3.3.E 215 Handrails BC-1003.3.3.11 215 Notes: JAM Page 3 of 10 No Topic Code Page Required Actual Section No. or Allowed 21. Structural Snow Loading—Ground BC Fig 1608.2 296 . 10� 2K4, Snow Loading---Roof(talc.) ASCE 7-98 Drifting Snow BC-1608.7 295 Ponding BC-1608.3.5 295 Floor Loading BC Table 1607.1 291 Balcony Loading BC-Table 1607.1 . 291 Wind Loading (talc.) BC-1609 297 Roof Walls Windows Seismic Loading (talc.) BC-1614 315 Foundation Depth BC-1805.2 398 22. Interior Finishes BC-Table 803.4 161 23. Swimming Pools BC-3109 629 24. Sun Rooms BC Appendix 1 693 : -25. Electrical Exit Lights or Signs BC-1003.2.10 203 Emergency Lights BC-1003.2.11.2 204 Emergency Power BC-2702 611 GenerbULighting-Exits-Stairs BC-1003.2.11 204 26. HC ACCESS Exempt,Buildings BC-1104.4 238 Parking BC-Table 1106.1 239 R -7 BCA 104.1 238. ntranc . BC71105.1 239 o leeping Rooms BC-Table-1107.6.1.1 241 #o 'its BC-1107.6.2 241 e Facili ' BC-1109.2 244 ervice C s BC-1109.12.3 246 reas of Refuge BC-1003.2.13.5 207 Supplemental HC Req'mts Appendix E 681 Notes: sc crAjj I o03.2. 13.7 IN JAM Page 4 of 10 No. Topic Code Page Required' Actual Section No. or Allowed 27. Fire Protection Equipment Sprinkler Systems FC-903 55 Other Extingushing Syst. FC-904 . 59 Kitchen Hood.Extinguisher FC-609.8 41 Standpipe Systems FC-905 62 Fire Extingushers FC-906 64 Fire Alarm Systems & SD FC-907.2 66 Fire Alarm Boxes FC-907.4.1 72 Smoke Detection FC-907.2.10 68 Hi-Rise Fire Safety FC-907.2.12 69 Visible Alarms FC-Table 907.10.1.2 73 Smoke Control FC-909 75 Smoke Vents FC-910 82 Fire Pumps FC-913 85 28 Plumbing Code Fixture Count PC-Table 403.1 21 Water Supply Service Pipe Size PC-603 33 Fixture Pipe Size PC-603.1 33 Pipe Material PC-Table 605.4 36 Labor Law Art. 1.0-A UFPBC-904.6 12,340 Pipe Insulation See Energy Code Backflow Prevention PC-Table 608.1 41 Sprinkler System PC-608.16.4 44 Lawn Irrigation PC-608.16.5 -44 Pipe Freezing PC-305.6 14 Sanitary Drainage Drain Pipe Size PC-Table 709.1 54 Drain Pipe Material PC-702 47 Labor Law Art. 10-A UFPBC-904.6 12,340 Vent Size PC-Table 910.4 63 Pipe Hangers P-C-Table-308.5- - 17 - -- - Air Admittance Valves PC-917 67 Notes: JAM Page 5 of 10 No. Topic Code Page Required Actual Section No. or Allowed 29 Mechanical Code Ventilation Rates MC-Table 403.3 24 Propane Below Grade MC-502.8.10.1 31 Dryer Exhaust MC-504 33 Kitchen Exhaust MC-506 34 Kitchen Hoods- MC-507 37 Kitchen-Make-Up Air MC-508 39 Chimney Termination MC-Table 511.2 41 Air Plenums MC-602 47 Fire & Smoke Dampers MC-607.5.1 52 Combustion Air MC-701 55 Confined Spaces—Def. MC-202 5 30 Fuel Gas Code . Appliance Location FGC-303 18 Combustion.Air. FGC-304 19. Clearance to Combust.. FGC-Table 308.2 25 Pipe Material FGC-403 46 Shut-Off Valves- FGC-409 53- Chimney Termination FGC-Fig. 503.5.4 63 Gas Vent Termination FGC-Fig. 503.6.6 .65 Exit Terminal-Location FGC-503.8 68 Clothes Dryer Exhaust FGC-613 96 Unvented RooriitHeaters FGC-620 99 31 Energy Code Prescriptive Method ECCC-Table 602.1(1) 50 High Truss Credit ECCC-602.1.2 51 Pipe Insulation—* Heating ECCC-Table 503.3.3.1 '44 Duct Insulatim-Heating ECCC-Table 503.3.3.3 45 Pipe Insulation—Hot Water ECCC-Table 504.2 47 HWH Heat Trap' ECCC-504.7 47 COMcheck Computer Software Compliance Report Required Notes: JAM Page 6 of 10 LIST OF CALCULATIONS THAT MAY BE REQUIRED FOR A COMPLETE CODE REVIEW. 1. Area Increase Based Upon Frontage And Sprinkler Increase. Frontage Increase: If= 100(F/P-0.25)W = Answer in % 30 Note: If= 75%when 4 sides accessible &water available Allowable Area: A. ="fable+ (A b,P x l,) + &b,._L Ij=Answer in Square Feet (BC—Pg. 74) 100 100 2. Exit Capacity Calculations (Table 1003.2.3)(BC-Pg. 202) (Occupancy Load for Exit)x (Egress Width per Occupant) _ (Required Width) 3. Snow Loading Calculations. (ASCE 7-98)(Eq. 7-1)(pg-69) & (Eq. 7-2)(pg-70) (ASCE = American Society of Civil Engineers) Pf=0.7CeCtlP9 = Flat Roof Snow Load Where: Pf= Flat Roof Snow Load (Calculated Above,Answer in.#per SF) Ce= Exposure Factor (BC-Table 1608.3.1)(Pg. 297) Ct=Thermal Factor (BC Table 1608.3.2)(Pg. 297) = Importance Factor (BC-Table 1604.5)(Pg. 287) P9= Ground Snow Load (BC Fig. 1608.2)(Pg:296) PS =.CsPi.= Sloped-Roof Snow Load Where: PS= Sloped-Roof Snow Load CS= Roof Slope Factor (ASCE 7-98)(Pg. 70) 4. Wind loading calculations. (Refer to Chapter 6 of ASCE 7-98) 5. Seismic Calculations. (See page 10 of this list) 6. COMCheck calculations (For verification of compliance with the Energy Code) JAM Page 7 of 10 . I COMMERCIAL FINAL.INSPECTION REP ORT Building& Code Enforcement Date inspection request received. Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive am/pm Depart � -- 742 Bay Road Inspector's Initi Queensbury,NY 12804 NAME �� PERMIT# �� 1 LOCATION DATE TYPE OF STRUCTURE N/A YES .NO CON54ENTS CnimneyP'B"Vent/Direct vent.location Plumbing Vert. Roof Complete Exterior finish grade complete haerior/exterior guardrails 42 in.platform/decks hsteaior/exterior ballasters 4 in.spacing platform/decks- Stair handrail 34 in.-38 in. Step risers 7 3/s in. Main door 44 in. All others 36 in. Lever handles Exits at grade or platform Canopy to cover req.exit doors Gas valve shut-off exposed&regulator(18 in.)above gra Floor bathroom watertight Other floors okay Hot water relief valve Boiler/fumace enclosure <250.000 BTU N/R 250.000 BTU to 1,000,000 BTU's(1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 30 ft.or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),3/<hour door of Storage/receiving/shipping room(2 hour), 1 '/z doors —7/ 1 '4 hour doors and closers '.hour corridor doors and closers Firesvalls/fire separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond .Alive listening system and signage assembly space Final Electrical Site Plan/Variance required Final Survey,new structures As-built septic system layout required_ Okav to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) Okay to issue C/C(Certif.of Compliance) Town of Queensbury Fire Marshal's Office V 742 Bay Road Queensbury, NY 12804 �+(�j _ Phone (518) 761-8205 Fax(518) 745-4437 QC, C SY� Fire Marshal's Inspection Report Request SCHEDULE Received: Permit#XbO D INSPECTIO? Ow EAMPM�, Name: ��1 0; r` E ANYTIME Location: APPROVED N/A YES NO COMMENTS EXITSl �- AISLE WIDTHS EXIT SIGNS—NORMAL - BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHERS i FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM i HOOD INSTALLATION INTERIOR FINISHES XI I STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS CLEARANCE TO ELECTRICAL REQUIRED SIGNAGE EMERGENCY PLAN MAXIMUM OCCUPANCY SIGN CHIMNEY MASONRY ROUGHIN FINAL CHIMNEY FACTORY BUILT ROUGH IN FINAL WOOD STOVE ROUGHIN FINAL VENTED GAS APPLIANCE ROUGH IN FINAL FIREPLACE MASONRY ROUGH IN l�llS�.IS/®ATE O FOR CO NOT OK jT FINAL FIREPLACE -�f FACTORY BUILT ROUGHIN INSP ED BY FINAL CO MDEV/C HRISJMIORD/LETTERS2001/FIRE MARS HALI NSPECTIONREPORT11022001 WHITE—BUILDING DEPARTMENT COPY YELLOW—OCCUPANT COPY COlbil!'IERCIAY. FINAI,INSPECTION REPORT Building& Code Enforcement Date inspection request received: I �` Office No. (518)761-8256 Dept. of Community Development Z Town of Queensbury Arrive am/pm Depart 742 Bay Road Inspector's Inn ' s Queensbury, NY 12804 eo NAME `�~`� P�� PERMIT# .J LOCATION ��.� DATE i —0 TYPE OF STRUCTURE N/A YES NO CO S ChnnneyP'B"Vent/Dired Vent location Plumbing Vent \ \ E1 - Roof Complete Y Exterior finish grade complete haz for/exterior guardrails 42 in.platform/decics D �� Interior/exterior ballasters 4 in.spacing platform/deccs \ A C "C)� U��C1J Stair handrail 34 in.-38 in. Step risers 7 3/<in. r ti ��►Eq —�l�� C t5� ?~fain door 44 in. All others 36 in. V. Lever handles Exits at grade or platform Canopy to cover req.exit doors Gas valve shut-off exposed&regulator(18 in.)above gra Floor bathroom watertight Other floors okay Hat water relief valve / ` Boiler/furnace enclosure <250.000 BTU N/R 250,000 BTU to 1,000,000 BTU's(1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut offwithin 30 fl.or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),3/4 hour door Storage/receiving/shipping room(2 hour), 1 '/x doors 1 ':hour doors and closers ?.hour corridor doors and closers Firewalls/fnre separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 r/2 hour,3 hour Ceiling fire stepping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond .Active listening system and signage assembly space Final Electrical Site Plan/Variance required_ �� � Final Survey,new structures .As-built septic system layout required Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) Okay to issue C/C(Certif.of Compliance) Foundation Inspection Report Office No. (518)761-8256 Date Inspection reque ece e Queensbury Building&Code Enforcement Arrive: a pm D part: 742 Bay Rd., Queensbury, NY 12804 Inspector's Initi _ . NAME: -RMIT#: 03- LOCATION: - INSPECT ON: TYPE OF STRUCTURE: jmmenls Y N N/A ootings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for i providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place a Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Glade 6 inch drop within 10 ft. LASueHemingway\13uilding.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection requ receive Queensbury Building&Code Enforcement Arrive: a De rt:' 10� a pm 742 Bay Road, Queensbury,NY 12804 hlspector's Initial : NAME: PERMIT#: c7�&3�() LOCATION: 0 INSPECT ON: �� Ci TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron, Copper Drain/Vent I Comm. l�Plumbing Vent/Vents in Place ; ugh Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping C e,Commercial Copper, CPVC,Pex One &Two Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation. If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doe January 28,2003 Foundation Inspection Report �� !� Office No. (518)761-8256 Date Inspection re st ec iv Queensbury Building&Code Enforcement Arrive: a p Depart: a 742 Bay Rd., Queensbury,NY 12804 Inspector's Initi s- NAME: P IT#: 7ents LOCATION: INSPECT ON:TYPE OF STRUCTURE: ComY N N/A FootingsPierson lit i Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Bacicfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\B uilding.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003