Loading...
2003-068 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20030068 Date Issued: 'Thursday, .September 25;.2003 This is to.certify that work requested to be done as shown by Permit Number P20030068 - `hag been completed. Tax Map Number: 523400-290-013-0001-017-000-0000 Location:_ 78 MASTERS COMMON NORTH Owner: MICHAELS GROUP LLC THE Applicant: MICHAELS GROUP LLC THE This structure may be occupied as a: By Order of Town Board Fireplace TOWN OF QUEENSBURY Garage - 2 Cars Attached Single Family Dwelling Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20030068 Application Number: A20030068 Tax Map No: 523400-290-013-0001-017-000-0000 Permission is hereby granted to: MICHAELS GROI TP LLC THE For property located at: 78 MASTERS COMMON NORTH in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and'approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Twe of Construction Value Owner Address: MICHAELS GROUP LLC THE 10 BLACKSMITH Dr Fireplace MALTA,NY 12020 Garage-2 Cars Attached Single Family Dwelling 282,000.00 Total Value 282,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2003-068 LOT 32 HSE#78 MASTERS COMMON NORTH 3142 SQ FT SINGLE FAMILY DWELLING WITH 2-CAR ATTACHED GARAGE AND 2 FIREPLACES AS PER PLOT PLAN SPECIFICATIONS $426.34 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday,March 14,2004 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Friday,March 14,2003 SIGNED BY �' for the Town of Queensbury. Director of Buil Mgde Enforcement Building Permit Application 'town of Queensbury-Dept of Community Development, 742 Bay Road, Queensbury,NY (518)761-8256 EC '/p A permit must be obtained before beginning construction. Permit File N -0 No inspection will be made until applicant has received a FCC Paid $' •34 a-V 'WAR 1 0 2003 valid building permit. All applicants' space~ on this Rec. FCC Paid {{$�- application must be completed and must appear on the Reviewed I3y:\J� TC WN OF QUEENSBU, application form. UILDING AND CODE Applicant: Ij4E Owner: r(1� Address: IQ g' f(�1tYLi�1 Address: i A N y1_ZC Phone# (5e) - fv3i 1 Phone Property Location: Lot Number: 32 / House Number -7g / m�tcrrst Subdivision Namc: �6 6,nY_-) Tax Map Number: 07 New Building: residence /commercial Estimated Market Value of Construction: $ _ ❑ Addition: residence/ commercial If an Addition, what will use of new addition be? ❑ Alteration: residence/ commercial o No change to exterior size: residence/coni'l ❑ Other work(describe ) i Check Occupancylnformation I" Floor 21" Moor Other Iloor TolaI Below sq.ft. sq. f . sq. I't. Square Feet 5g3L Single family dwelling �t�3`v 1 -a, Z7 70 `❑ Two family dwelling ❑ Townhouse ❑ Multifamily dwelling #of units ❑ Office ❑ Mercanti le ❑ Manufacturing ❑ 1 car detached garage ❑ 2 car detached garage ❑ 3 car detached garage ❑ 1 car attached garage 3G 2 car attached garage ❑ 3 car attached garage III ❑ Storage building- ------- commercial 3 ❑ Storage building- residential ❑ Other �0 LL-i S Will any second-hand or ungraded lumber be used? If so, for what? 9.11" Type of Heating T S stem: electric/ oil / as wood /forced hot air/ baseboard/other: YI b Y 0 Number of Pireplaces to be installed �_ Number of 1I'ondstnves to be installed N,&. List below the person(s)responsible For supervision of work as regards to building codes: Name Yir ` ` _i A'd`d`ress`� Phoonne�N1.1111 der Plumber G, C locYnb�•R 1�_ _ �4- k�n-& k -2`�-�-�C- Mason ,r�•Ca. 3 Cs�Q <—` 4-LI- 99W�_) Electrician y _el—)C- Declaration: please sign below after you have carefully read the slalerimit: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a hvc and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code, the Zoning Ordinance and all other laws pertaining to the proposed work shall he complied with, whether specified or noted,and Thal siiclt work is authorized by the owner. Further, it is understood that 1/we shall submit, prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administralor or Director of Building and Codes,an its Built Suri,e)y by a licensed surveyor;drawn to scale,showing actual location ol'all new construction Signature:—_T owner,owner's agent,architect,contractor AProject Nam : ' BP# —06OR Address: K Building Permit Submission Singl-family dwelling Tuofiarraly dwelling Checklist All items below must be_checked either.yes,no or not applicable prior to submission of any building permit to the Town of Queensbury Building Department. If any of the below iteiiri�:are lacking,the permit will not be accepted until such time as the application is deemed complete for submission. 1. Building Permit Application Completed ... ... ... ... ... ... ... ... ... ...... ... s ❑no ❑n/a 2. Energy Form or Checld&te Energy Code Compliance Forms Complete.. s ❑no ❑n/a 3. Energy Code Inspector's Report from ChecU&te Program.. ... ... ... ..... ❑no ❑n/a 4. Septic application completelyfilled out(if applicable)... ... ..;.. ❑yes ❑no 5. Solid Fuel Burning or Gas Appliance Form... ... ... ... ... .. ` .- yes no n/a " 6. Electrical Inspection Form.... ... ... ... 7. Two (2) coin 'ple'te sets of structural drawings... .. ... ... ... ... ... ... ... ... ... .. . s ❑no ❑n/a a) floor plan;,b) foundation plan;c) cross sections:d) elevations; e)windgw and door schedule ' 8. Two (2) site plans showing location of the structure to be built. ... ... ... ... s ❑no ❑n/a location of well or water lines,location of septic system or sewer line. 9. Setbacks from property lines to new structure ... ... ... ... ... ... ... ... ... ... .. ❑no ❑n/a 10. Setbacks to neighboring wells and septic systems,including onsite well... . Eyes Ono and septic systems (if applicable) 11. DrivewayPemut... ... ... ... ... ... ... ... ... ... ... ... ....... ... ... ... ... ... ... ... ... s ❑no ❑n/a Date: 3 Staff Initialz- zAr L:\SueHemingway\ udUding.Permit.FORMS\Generic Checkhst.doc Residential Plan Review: One&Two Family Dwellings Check Y/N/N/A (2)Full sets of plans Over 1,500 sq. ft.—stamped Design loads on plans: 90 wind Floor Loads 40 psf 70 ground snow load Sleeping areas and Attics 30 psf Calculations: Window Schedule with glass size Door Schedule/Main Entrance 36"Door Emergency escape for Bedrooms and Habitable Space Above/Below grade, 5.7 sq. ft. Grade,5.0 sq. ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check paperwork compliance and inspectors checklist: OK Vertical Rebar as required by code Dampproofing/Waterproofing materials on plans ,Foundation Drainage on plans, if required 6'Drop in 10' Exterior Grade Framing cross section for each roof line,Vertical Fire Stopping every 10' where required Ice and Snow shield 24"inside exterior wall Platforms at exterior doors Stairway headroom 6 ft. 8 in. all stairs 36"Width Stair run and rise Winder run and rise piral not allowed from 2°d story moke detectors battery backup and proper location Bathroom Fixtures proper clearance Hall width,36"min. Handrails more than one riser on open sides fling and Guards>30"/Basement Stairs included/Closed Risers more than 4"in height Safety Glazing Notes for required areas Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30" Crawl Spaces 18"x 24"Access Carbon Monoxide Detector lowest sleeping level Soil Test Results, if required Septic to well or water line separation Al paperwork signed Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY (518)761-8205 i r . Application for Fuel Burning Appliances & Chimneys !. applicable to solid fuel & vented gas ,appliances % Date��r.-�r« �s 20 (V,, Permit No. b Application is hereby made to the Building& Codes Of ice for the iss•uarzce of a Building an di�se Per init pursuant to the New York State Fire Prevention,and Building-Code. The applicant or owner agrees to comply withh all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to per f win required inspections" NOTE to applicant: Rough-in and Final Inspections,are required. Applicant Information Fuel Burning Appliance Information (circle appropriate words) Name: Stove: wood coal pellet gas Fireplace insert Address: i 1 yd -f� Fireplace, factory-built: wood c as I�'� ,9f iu^na-l� Fireplace, masonry: wood gas Furnace: wood 'gas oil Prone: If non-masonary applicance, please provide _ Owner: m AL •_ Manufacturer Name: Address: Model Number: Chimney Information Phone: ;y (circle appropriate words) Masonry block ' brick stone . Flue the to l size: inches Exact Address`1� t1 ,,--0,j6V Ao f' �, uclior:of uista . tion Factory-Built of consii Manufacturer name: Model Number: No -Listed By: Number: Construction/Installation must con orin to NYS Fire Prevention &Building Indicate (circle) chimney material: Code. Consult available Town of Queensbury Handouts regarding required inspections. Double ivall / Triple wall / Insulated / Direct venting Chimney Liner C�,etl�ter'rsr nepasrtment—To�� of QiZ�41`2r6rbiZZ'y, 3V"e�YTorli: Fire Marshal Code# $Collected S Reyitnded .Reccr ed fi�orrr (refiutrfecl to):--`_t t,.;:✓ . !_s_____,__.._ address: -- A 173 3389 (190) Public Safety ,. 'c ` ; ,,- A 233 2655 (230)Minol-Sales DATE: N White(�A'pplicant) / Green(Fire Marshal) / Yellow(Bldg. Dept.) ! Pink&: Goldenrod(Cashier's Dept.) Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY (518)761-8N5 Application for Fuel Burning Appliances & Chirhne s applicable to solid fuel & vented gas appliances . J Date.. 1 20 _. Permit No. 03— U(P Application is hereby made to the Building cYz Codes Office for the issuance of a Building and Use Permit pursuant to the New York State Fire Prevention.and Building Code. The applicant or owner agrees to comply with all applicable laws, ordinance's, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to pei f)qn required inspections. NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information Fuel Burning Appliance Information (circle appropriate words) Name: ,g a.��_ ,nc .��rr k L� Stove: wood coal pellet gels Fireplace insert Address: = Fireplace, factory-built: wood r- Ps Fireplace,.masonry: wood gas Furnace: wood gas oil Phone: P 1 i If non-masonary applicance,please provide Owner: < Manufacturer Name: Address: Model Number: Chimney Information Phone: (circle appropriate words) Masonry block brick stone :vax Flue the steel size: inches Exact Address:-7C., �xka\Vgtr Pi,6Aiwr tA of construction or installation .Factory-Built Manufacturer name: Model Number: Note: Listed By: Number: r ` Construction IInstallation must conform to NYS Fire Prevention &Building Indicate(circle) chimney.material: Code. Consult available Town of Queensbui)) Handouts regarding required inspections. Double hall / Triple wall / Insulated / Direct venting Chimney Liner .I Ca,,�f er'�D�p�r�ine�t—To��_of Qzzee�,er�bury, 3V®sue Yorl3: J ; Fire Marshal Code# $Collected $Refiende�_ Received fr-onz (r ended to).;7 = _ .�`.: address: A 173 3389 (190) Public Safety A 233 2655 (230)Minor Sales DATE: - +rs` 1 _ '=� T 1 q _ D-P- d f White(Applicant) / Green(Fire Marshal) / Yellow(Bldg. Dept.) / fink K Goldenrod(Cashier's Dept.) Town of Queensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(518) 745-4437 � Fire Marshal's Inspection Report Request SCHEDULE `�j Received: Permit#C23-09 INSPECTION ON: l Name: AM PM ANYTIME Location: APPROVED EXITS N/A YES NO COMMENTS AISLE WIDTHS EXIT SIGNS-NORMAL - BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLERSYSTEM FIRE SUPPRESSION SYSTEM HOOD INSTALLATION INTERIOR FINISHES STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS CLEARANCE TO ELECTRICAL REQUIRED SIGNAGE EMERGENCY PLAN MAXIMUM OCCUPANCY SIGN CHIMNEY MASONRY ROUGH IN FINAL CHIMNEY FACTORY BUILT ROUGH IN FINAL WOOD STOVE' ROUGH IN FINAL VENTED GAS APPLIANCE ROUGH IN FINAL FIR LACE M ONRY ROUGH IN ®K THIS DATE (O�K FOR CO NOT OK FINAL FIREPLACE FACTORY BUILT ROUgL4 IN INSPECTED 13Y FINAL COM13EV/CHRISJMIORD1LETTERS2001/F IREMARSHALINSPECTIONREPORT11022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT CONY Residential Final Inspection Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&c Code Enforcement Arrive: am/ m Depa m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: r, f, NAME: 1 PER iV1IT#: V � - b� LOCATION: DATE: TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 in.or more P,stairs, decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in. to 38 in. Platform at all extgrior doors Vx Interior Handrails stairs 2 or more risers Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety lzin Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor trass,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches 3/4 hour fire door/door closer Garage fireproofing Duct work Sealed properly Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s .ft.-150 s . ft.vents Building No./Addr ss v sible from ad Final Electrical •tl Site Plan /Varian e?elluimd Final Survey Plot Plan —4, As Built Septic System/Sewer Dept. Inspection Sticker V1, Flood Plain Certification, if required Okay to issue C/C(Cert. Of Com liarice) Okay to issue Temporary C/0(Cert. Of Occupancy) Okay to issue Permanent C/0(Cert. Of Occupancy) L:\SueHemingway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003 TOWN:OF QUEENSBURY BUILDING & CODE ENFORCEMENT 742 BAY ROAD QUEENSBURY NY 12804 (518) 761-8256 ARRIVE: DEPART: INSP: _ FINAL INSPECTION REPORT (hotel, motel, apt. complex) DATE INSPECTION REQUEST RECEIVED: NAME A n�n LOCAT ION �l� DATE O P,EERRMIT TYPE OF STRUCTURE FOOTINGS _BACKFILL_ FRAMING_ PLUMBING_ INSULATION N_/ YES NO CHIMNEY/"B" VENT HEIGHT PLUMBING VENT/FIXTURES ROOFING EXTERIOR FINISH HEATING/HOT WATER RELIEF VALVES FLOORS FOUNDATION INSULATION INTERIOR STAIRS/RAILINGS STOCKROOM ENCLOSURE FIRE/DEMISE WALLS PENETRATION _ FIRE DAMPERS CEILING FIRE STOPPING FIRE DOORS/CLOSERS EXIT DOOR HARDWARE EXIT STAIRS/RAILS PLATFORM/ELEVATOR HANDICAPPED ACCESS HANDICAPPED BATHS -- HANDICAPPED PARKING — FINAL ELECTRICAL SITE PLAN/VARIANCE REQ. AL SURVEY�OOR� �IFRE OK TO ISSUE MAP REFERENCE: MASTER'S COMMON NORTH DATED: AUGUST 26, 1987 BY: VAN DUSEN & STEVES FILED: MARCH 10, 1988 DRAWER 17 FOLDER 1 LOT 31 -'' #78 �. LOT 32 33,062.82 sq ft 0.77 acres ,.a • LOT 33 00 Or 3- RECEIVED SEP 9 9 2003 1 TOAJN QF QUEENSBURY A' DING AND CODE 50' E NEW,., {I 0 • •look 1 • a ei IMMEP 4, 2003 qWMXNWM KMMM 40 XWO TO A XW&Y Scale 1'=30' YM WAM A UMOM uwo OW4b=Oft a A Map of a Survey made for KO"M$MR mUCA"UK, aw Steves ,.�,. ��..�� - JOHN W. WEBER, SR. S-- 1 Tp NOWCO WS�VMa M ACCOOMM MW WK oM"mt or nw w rot Mw•uNl ��,�M&R rala A90�1�b � Land Surveyors AIO t ■RK70tt MIP MMCi1\dl{W."RM OLT KATHLEEN A. WEBER "miff"M ww'w=M s FlM•IINA w ON W NWO A IM 111E ditft .4DOWMRAL 189 Haviland Road Queensbury, New York 12804 Town of Queensbury, barren County, New York WEM (518) 792-8474 New York Lie. No. 50135 NO. DATE DESCRIPTION VWG. NO. MCN-32 I✓ Rough Plumbing / Insulation Inspection Report tt` Office No. (518)761-8256 Date Inspection request received: T a 3 Queensbury Building&Code Enforcement Arrive: am/p De art: pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: ��"'� PERMIT#: `� LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial Co. CPVC,Pex One &Two F mily sulati n T esidential Check/Co ci 1 C e k Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: !L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: 13/ Queensbury Building&Code Enforcement Arrive: am/ D a an-1/pin 742 Bay Road, Queensbuly,NY 12804 Inspector's Initials:sYnI NAME: PERMIT#: 03 J 0 LOCATION: INSPECT ON: �:2—:7 TYPE OF STRUCTURE: c '7 Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron, Copper Drain/Vent I Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates p.L&A G Head or Air Supply Test 1 Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial VTper, CPVC,Pex One &Two Family ulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly � �� � ��� �(�✓ COMMENTS: L:1SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 -2- � Town of Queensbury s Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(518) 745-4437 r Fire Marshal's Inspection Report Request r SCHEDULE _ �\ Received: Permit# O,3— INSPECTION ON: cQ;7` J� Name: s AM YTIME Location: APPROVED N/A YES NO COMMENTS EXITS AISLE WIDTHS J �1 EXIT SIGNS-NORMAL `FiP� �. 1 V-1ce - BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHERS �� N cC)p�� FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM r� FIRE SUPPRESSION SYSTEM HOOD INSTALLATION INTERIOR FINISHES STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING 1� UNITS fN CLEARANCE TO ELECTRICAL REQUIRED SIGNAGE `•l (Z.�L EMERGENCY PLAN 443 MAXIMUM OCCUPANCY SIGNCHIMNEY C� f MASONRY ROUGH IN FINAL CHIMNEY FACTORY BUILT ROUGH IN FINAL WOOD STOVE ROUGHIN FINAL VENTED GAS APPLIANCE ROUGH IN FINAL FIREPLACE MASONRY ROUGH IN OK T OM NOT OK FINAL -- FIREPLACE FACTORY BUILT ROUGH IN INSPECTED RY FINAL I/- f COMDEVICHRISJ/WORD/LETTERS2001/FIREMARSHA SPECTIONREPORT110 001 WHITE-BUILDING DEPARTMENT COPY YEL O -OCCUPANT COPY Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pi�I art: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. J NAME: �,�i Cj�j2 PERMIT#: . ✓ �� LOCATION: Aes_ Cam„,. INSPECT ON: -7 TYPE OF STRUCTURE: Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour ire wall 2, 3, 4 hour �iresto m � 1 , en� netra�tion sealed` 16 inch insulation in cavity min. C(�f� /-�-( /—,- Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) S �/ 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Rv ( ge LASueHemingway\BuiIding.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 / ! T7 1� �,�cc Framing / Firestopping Inspection Report - 1 ► t Office No. (518) 761-8256 Date Inspection request received: a Queensbury Building& Code Enforcement Arrive: am/ m part: anI/ T. 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: ` ,J PERMIT#: 03- 0 V�Ry LOCATION: b INSPECT ON: � O' TYPE OF STRUCTURE: S' Y N N/A COMMENTS ,king Jack Studs/Headers �Q Bracing/Bridging �n.1/�� /`�"�f'J� Joist hangers l Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft, floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire w , 3, 4 hour estopp.ing enetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade / 5.0 sf grade L:\SueHe \Buildin.-.Codes.Ins P-ection. ORMSTramin Firestopping Inspection Re ort.doc JanuarY28,2003 Framing / Firestopping Inspection Report V Office No. (518) 761-8256 Date Inspection request received: ^ Queensbury Building& Code Enforcement Arrive: am/p epa am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: INSPECT ON: 77 6 ,5 TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses chor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORNIS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ r epart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. NAME: KA-3 (SAP PERMIT#: LOCATION: 7f INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Dr af opping 1,000 sq. ft. floor trusses chor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall i Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueFlemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report w 3,0 Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/p epart: r' am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: `\ ` ` PERMIT#: 63_0W LOCATION: INSPECT ON: _ �3 TYPE OF STRUC URE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses chor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour ���-rC. �C�k12 Firestopping -A- Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade 1_ASueF1emingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection requ st received: d Queensbury Building&Code Enforcement Arrive: am/p epart:Z m/ 742 Bay Road, Queensbury,NY 12804 Inspector's Initia NAME: `, �� 2� 5 �l u' PERMIT#: ZU03 —a fig' LOCATION: C S C h a rVPSPECT ON: 3 TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents ' Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place ough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper, CPVC,Pex One &Two Family Insulation/Residential Check/Commercial Check Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: LASueHemingwaylBuilding.Codes.Inspection.FORMS\ ough Plumbing Insulation Report.doc January 28,2003 - A-� Framing / Firestopping Inspection Report Y - Office No. (518) 761-8256 Date Inspection request received: U 3 Queensbury Building&Code Enforcement Arrive: am/)epart.1 A)L akvpm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: /" PERMIT#: 3 LOCATION: INSPECT ON: 3 TYPE OF STRUCTURE: Y N N/A Framing COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center ce and snow field 24 inches from w 1 Fire separation 1, 2, 3 hour Fire wall 2, 3;4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\BuiIding.Codes.Inspection.FORM STraming Firestopping Inspection Report.doc January 28,2003 A141t Foundation Inspection Deport Office No. (518) 761-8256 Date Inspection request received: 7 Queensbury Building&Code Enforcement Arrive: am/p Depar . am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Init7als: - NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place • Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing f Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L;\SueHemingway\Building.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 �&�, 5 ( �d v— �yJ 6 VAN Foundation Inspection Report Office No. (51-8) 761-8256 Date Inspection re eiv j O_ Queensbury Building&Code Enforcement Arrive: a Depart: pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initial NAME: Ell #: LOCATION. / j , `4INSPECT ON: TYPE OF STRUCTURE: Com nts Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place R Foundatio n Foundation/Waterproofing Type of Dampproofi /Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\,SueHemingway\Bui]ding.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Vv Foundation Inspection Report Office No. (51-8) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ �Depart. pm{llf 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: O PERMIT#: LOCATI01 INSPECT ON: Lj TYPE OF STRUCK C ments Y N N/A Foot' gs., Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement f of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place t Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump i Footing Drain Stone: 12 in wardth -" he' s above footing 6 "1 pol for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.Inspection.FORMSToundation Inspection Report.doc January 28,2003 r Foundation Inspection Report 3 Office No. (518) 761-8256 Date Inspection req r ce� Queensbury Building&Code Enforcement Arrive: pm De rt:4 . p a p 742 Bay Rd., Queensbuly,NY 12804 Inspector's Ini� NAME: IT#: LOCATION: SPECT ON: U TYPE OF STRUC '-� Comments Y N NT/A Footings Piers Monolithic Slab \J Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. is for his urpose on site. oundatiori/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\I3uilding.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: �s f Queensbury Building&Code Enforcement Arrive: am/p D a am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: rN r, Q PERMIT#: v F LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A otings- Piers Monolithic Slab Reinforcement in Place ., The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\.SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Reporkdoc January 28,2003 March 14, 2003 lV 0� 1 '2003 Dave Hatin /`DI�G�N�CSeUr4� Office of Building and Code Enforcement ®E 742 Bay Rd. Queensbury,NY 12804 Ce e: 78 M No asters Common h ar Dave: Per soil conditions at the above address, (1)#6 rebar will be required vertically @ 4'0"o.c. in the foundation wall. Sincerely, ?Keit upert C Engineering lI ,ice ka 6 11� RECEIVED R 1 0 2003 3 - Permit N BUILDINGN CO®E Y MECcheck Compliance Report Checked By/Date Proposed New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release lb Data filename: C:\Program Files\Check\MECcheck\Complete Works\HMAND\78 Masters Common North.cck TITLE:Weber Residence COUNTY:Warren ----STATE:-New York-- ------------ ----- ---- -- ---_LL__. __ HDD: 7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE: 03/05/03 DATE OF PLANS:-March 5,2003 PROJECT INFORMATION: HI725 Savannah- 78 Masters Common North Queensbury,NY` 12804 COMPANY INFORMATION: The Michaels Group 10 Blacksmith"Dr Malta,NY 12020 COMPLIANCE:Passes Maximum UA=713 Your Home=555 - 22.2%Better Than Code - - - -- Gross-- Glazing - - Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA . Ceiling 1:Raised or Energy Truss 1723 30.0 0.0 55 FirstFloor-Walls:Wood Frame, 16.."o.c. 1944---19.0---- 0.0 94 2x Dining-AH:Wood Frame,Double Pane with.Low-E 24 0.340 8 lx Dining-D:Wood Frame,Double Pane with Low-E 15 0.340 5 Foyer#lB: Glass 37 0.350 13 2x Living-D:Wood Frame,Double Pane with Low-E 31 0.340 11 lx Bath-N:Wood Frame,Double Pane with Low-E 6 0.340 2 lx Study-C:Wood Frame,Double Pane with Low-E 31 0.340 11 lx Kitchen-BH:Wood Frame,Double Pane with Low-E 16 0.340 5 lx Brkfst-BX:Wood Frame,Double Pane with Low-E 16 0.340 5 2x Brkfst-BJ:Wood Frame,Double Pane with Low-E 21 0.340 7 lx Brkfst-BY:Wood Frame,Double Pane with Low-E 33 0.340 11 Brkfst#34: Glass 23 0.350 8 2x Family-Y:Wood Frame,Double Pane with Low-E 27 0.340 9 2x Family-BS:Wood Frame,Double Pane with Low-E 10 0.340 3 2x Family-E:Wood Frame,Double Pane with Low-E 55 0.340 19 2x Family-BP:Wood Frame,Double Pane with Low-E 20- 0.340 7 Laundry#20: Solid 19 0.240 5 2nd Story Walls:Wood Frame, 16"o.c. 1823 19.0 0.0 99 1x MBath-V:Wood Frame,Double Pane with Low-E 16 0.340 5 2x MBed-BX:Wood Frame,Double Pane with Low-E 33 0.340 11 lx MBed-BG:Wood Frame,Double Pane with Low-E 29 0.340 10 lx Bed#4-C:Wood Frame,Double Pane with Low-E 31 0.340 11 lx Foyer-CQ:Wood Frame,Double Pane with Low-E 8 0.340 3 2x Bed#3-BA:Wood Frame,Double Pane with Low-E 30 0.340 10 1x Bath-N:Wood Frame,Double Pane with Low-E 6 0.340 2 Ix Bed#2 E:Wood Frame,Double Pane with Low-E 27 0.340 9 Basement Wall 1: Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insul 1565 0.0 11.0 100 Basement windows:Wood Frame,Double Pane with Low-E 11 0.520 6 Door#20: Solid 19 0.240 5 Floor over Garage&Foyer: All-Wood Joist/Truss,Over Unconditioned Space 122 19.0 0.0 6 Furnace 1:Forced Hot Air,92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application. The proposed systems ha_v_e been-designed-to-meet the-P-roposed-Ne -York State-Energy-Conservation Construction Code requirements. Builder/Designer Date MECcheck Inspection Checklist Proposed New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release lb_ DATE:03/05/03 TITLE:Weber Residence Bldg. Dept. Use Ceilings: - [ ] i 1. Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation Comments:- __ --Insulationmust-achieve-fullheight_over-the plate-lines-of extenor walls:— --- -- Above-Grade Walls: [ ] 1.. First Floor Walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 1` ' 2.' 2nd Story Walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation . Comments: Basement Walls: [ ] i 1. Basement Wall l:Solid Concrete or Masonry,7.6'ht/6.6'bg/6A'insult `R-1.1.0 continuous insulation Comments: 'Exterior insulationmust have a-rigid,opaque,weather=resistant protective covering that covers the exposed(above grade)insulation and extends at least 6 in.below grade: 2x Dining:AH:Wood Frame;Double Pane,with Low-g,U factor 0340 `For windows without labeled U'-factors,describe features J #Panes Frame Type Thermal Break?_-[. ]Yes:[ ]-No Comments: 1x Dining-D:Wood Frame,.Double Pane with Low-E,U4actor 00.340 For windows without labeled U--factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No - ----- - -Comments:'.--- - - - [ ] 3.==.2x Living D:,Wood Frame,Double Pane with Low-E,U factor 0.340 - — For windows_without labeled U-factors,describe features. ` -.: #Panes Frame Type Thermal Break?[ ]Yes_[ ]No Comments: [ ) i 4. 1x Bath-N:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: - #-Panes - . Frame Type- — —Thermal Break?[ ]Yes [ ]No Comments: [ ] 5. lx Study-C:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows.without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ )Yes [ ]No Comments: [ ] i 6. lx Kitchen-BH:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]'Yes [ ]No Comments: [ ] i 7. lx Brkfst-BX:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] i 8. 2x Brkfst-BJ:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 9. 1x Brkfst-BY:Wood Frame, Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 10. 2x Family-Y:Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 11. 2x Family-BS:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 12. 2x Family-E:Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type' Thermal Break? [ J Yes[ ]No Comments: [ ] 13. 2x Family-BP:Wood Frame,Double Pane with Low-E,U-factor:0.340 -- --�- - For windows without labeled-U=factors,-describe features:— --- #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] i 14. lx MBath-V:Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] i 15. 2x NMed-BX:Wood Frame,Double Pane.with Low-E,U-factor:0.340 For windows without labeled U-factors,.describe features: #Panes Frame Type :Thermal Break?[ ]Yes [ ]No Comments:. [ ] i 16. 1x MBed-BG:Wood Frame,Double;Pane With Low-E,U-factor:0.340 For=windows.without labeled U-factors`describe.features: #Panes. Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] i 17. 1x Bed-#4-C:Wood Frame,Double Pane with Low-E,U-factor: 0.340 Forwindows without labeled U-factors;describefeatures: #Panes. Frame Type Thermal.Break? [ ]Yes [ ]No Comments: [ ] 18. lx Foyer-CQ:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors;describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: _ - [ ] i 19. 2x Bed#3-BA:Wood Frame,Double_Pane.with Low-E,U-factor:0.340 For-windows without labeled U-factors;describe features: _ #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] i 20. lx Bath-N:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[. ]-Yes-[- ]-No Comments: [ ] 21. lx Bed#2-E:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] i 22. Basement windows:Wood Frame,Double Pane with Low-E,U-factor:0.520 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: Boors: [ ] 1. Foyer#lB: Glass,U-factor: 0.350 #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 2. Brkfst#34: Glass,U-factor: 0.350 #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 3. Laundry#20: Solid,U-factor:0.240 Comments: [ ] 4. Door#20: Solid,U-factor:0.240 Comments: Floors: [ J 1. Floor over Garage&Foyer:All-Wood Joist/Truss,Over Unconditioned Space, R-19.0 cavity insulation Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,92 AFUE or higher Make and Model Number Air Leakage: [ ] .Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be Type IC rated and installed with no penetrations,or Type IC or non-IC -- - ----—rated-installed-inside-an-appropriate-air-tight assembly with a 0:5"clearance from combustible materials and 3"clearance from insulation. Vapor Retarder: [ ] . Required on the warm-in-winter side of all non-vented framed ceilings;walls,and floors. Materials Identification: ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] - Materials and equipment must be identified so that compliance can-be determined. Manufacturer manuals for all installed heating and cooling:equipnient and service water heating equipment must be provided. [ ] Insulation R-values,glazing:U-factors,and heating equipment:efficiency must be clearly marked on the building plans or specifications. Duct Insulation: -Supply ducts in unconditioned attics or outside the.building;must be insulated to R-11. [. .] I Return ducts in.unconditioned attics or outsidethe building'mustbe insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-1.1. ['. ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements.. Duct Construction: ] 1 All joints,seams,and connections must be securely fastened with welds,gaskets,-mastics _(adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape-is notpemritted. -�- Exception:Continuously welded and locking-type--longitudinaljoints and seams.on ducts operating at less than 2 in.w.g.(500 Pa). = [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ J Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55°F must be insulated to the levels in Table 2. a Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. , Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Ran e F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250- 1.0 1.5 1.5 2:0 Low Temperature 120-200 0.5 1.0 1.0 .1.5 Steam-Condensate(for feed water)_ Any 1.0 1.0 1.5_ __ ____-2.0 - Cooling Systems - Chilled Water,Refrigerant, 40-55 0.5., 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only) RECEIVED TOW10UEENSEL o f BUI I tf •1, 'tr> '! i E • X%J 1 Iro ,Idl�,l:�:a: 6�. . � rj) cn n RTH p6 _VES