Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2003-082
TOWN OF QUEENSBURY �5 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 L a" Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20030082 Date Issued: Monday, June 23, 2003 This is to certify that work requested to be done as shown by Permit Number P20030082 has been completed. Tax Map Number: 523400-297-009-0001-003-000-0000 Location: 270 MEADOWBROOK Rd Owner: JEFFERY GREENE Applicant: JEFFERY GREENS This structure may be occupied as a: By Order of Town Board Garage - 3 Cars Detached TOWN OF QUEENSBURY Director of Building&Code Enforcement TOWN OF QUEENSBURY' 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20030082 Application Number: A20030082 Tax Map No: 523400-297-009-0001-003-000-0000 Permission is hereby granted to: JEFFERY GREENE For property located at: 270 MEADOWBROOK Rd in the Town of Queensbuty,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbuty Zoning Ordinance. T-ne of Construction Value Owner Address: JEFFERY GREENE 270 MEADOWBROOK Rd Garage-3 Cars Detached $15,000.00 QUEENSBURY,NY 12804-0000 Total Value $15,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency DOCKS-N-MORE JOHN BARNES 236A DIXON Rd OUEENSBURY.NY 12804-0000 Plans&Specifications 2003-082 900 SQ FT 3-CAR DETACHED GARAGE AS PER PLOT PLAN SPEC IFICATIONS $90.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,March 31,2004 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated a wn of ee sbu ; Monday,March 31,2003 SIGNED B for the Town of Queensbury. mY• Director of Building&Code Enforcement Building Permit Application Town of Queensbury-Dept of Community Development,742 Bay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No.Q003-OgD— No inspection will be made until applicant has received a Fee Paid $2n valid building permit. All applicants' spaces on this Rec.Fee Paid $ application-must be completed and must appear on the Reviewed By: application form. Applicant: �_� a�I ►s i�i �`tP1S Owner: 0 Address: 3 Address: 9"7 d MEAPO(k!BU uE U(?—Li C v-eZKSSRU g:Q N,q (Z26q Phone#(a/8)]aL- o yz 3 CQQ.Q--Ir— Phone#( 5��) '79Z- Property Location: Lot Number: / House Number,-,Q Subdivision Name: Tax Map Number: 9,QI.Q -/3 d New Building: reside /commercial 'Estimated Market Value of Construction: $ / ❑ Addition: residence/ commercial If an Addition,what will use of new addition be? ❑ Alteration: residence/ commercial ❑ No change to exterior size: residence/com'l ❑ Other work(describe ) Check Occupancylnformation I't Floor 2° Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet ❑ Single family dwelling ❑ Two family dwelling ❑ Townhouse ❑ Multifamily dwelling #of units TOM OF QUE D pDEY ❑ Office ❑ Mercantile ❑ Manufacturing ❑ 1 car detached garage ❑ 2 car detached garage 3 car detached garage 05 , ❑ 1 car attached garage ❑ 2 car attached garage 0 3 car attached garage ❑ Storage building- commercial ❑ Storage building- residential ❑ Other What is the proposed height of the structure 2-0 feet inches Will any second-hand or ungraded lumber be used? If so,for what? 126 Type of Heating System: electric/ oil / gas/wood /forced hot air/ baseboard/other: Number of Fireplaces to be installed Number of Woodstoves to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder Plumber Mason Electrician Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that 1/we shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual location of all ew construction. Signature: owner,owner's agent,architec ntracto r Residential Plan Review: One&Two Family Dwellings Check Y/N-/N/A ! ©� (2)Full sets of plans Over 1,500 sq. ft.—stamped Design loads on plans: 90 wind Floor Loads 40 psf 70 ground snow load Sleeping areas and Attics 30 psf Calculations: Window Schedule with glass size Door Schedule/Main Entrance 36"Door Emergency escape for Bedrooms and Habitable Space Above/Below grade, 5.7 sq. ft. Grade, 5.0 sq. ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check paperwork compliance and inspectors checklist: OK Vertical Rebar as required by code/Anchor Bolts '/2 x 7 6' O.C. Dampproofmg/Waterproofing materials on plans Foundation Drainage on plans,if required 6"Drop in 10' Exterior Grade Framing cross section for each roof line,Vertical Fire Stopping every 10' where required Ice and Snow shield 24"inside exterior wall/Proper Vent,Attic Vent Platforms at exterior doors Stairway headroom 6 ft. 8 in. all stairs 36"Width Stair run and rise Winder run and rise Spiral not allowed from 2° story Smoke detectors battery backup and proper location Bathroom Fixtures proper clearance Hall width, 36"min. Handrails more than one riser on open sides Railing and Guards>30"/Basement Stairs included/Closed Risers more than 4"in height Safety Glazing Notes for required areas Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30" Crawl Spaces 18"x 24"Access Carbon Monoxide Detector lowest sleeping level Soil Test Results,if required Septic to well or water line separation All paperwork signed Residential Final Inspection Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: �.� am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: ,� NAME: 69 c—c—d PERMIT#: — D8-" LOCATION: ei2,dw< DATE: C� D TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in.or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler .Relief Valves installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches '/<hour fire door/door closer Garage fireproofing Duct work Sealed properly Attic access 30 in.x 2 in. x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required 0kay_to-issue C/C(Cert. Of Compliance) Okay to issue Temporary C/O(Cert. Of Occupancy) Okay to issue Permanent C/0(Cert. Of Occupancy) Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p2CI Depart: . m/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials. \ NAME: L% C PERMIT#: LOCATION: INSPECT ON: —75 TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place �� The contractor is responsibl& providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofmg/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper .Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. �1 Framing / Firestopping Inspection Report � Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&.Code Enforcement Arrive: ar p 1xt am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: allu 0PERMIT#: LOCATION: INSPECT ON: — -- TYPE OF STRUCTURE: Y N N/A COMMENTS raming Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building:Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 CFF GOZE10t: I PfeAcss I' . 1. ._,. 2 ,aq Ac- 7 9 � ! 4 A I MAR zn3 TONNN OF O��p CODEY I `}�c gU1LDING