Loading...
CC-0541-2021 • Office Use Only ADDITION/ALTERATION PERMIT Permit#: CC ' b5�\ • Z02� APPLICATION Permit Fee:$, 00 Town ofQucens6ury u 742 Bay Road,Queensbury,NY 12804 Invoice#: P:518-761-8256 www.gueensburv-net Flood Zone? Y N Reviewed O Project Location: Vv- W oac\vo z. QA Tax Map ID#: Subdivision Name: PROJECT INFORMATION: TYPE: Residential X Commercial, Proposed Use: Single-Family _Two:Family _Multi-Family(#of units ) _ Townhouse Business Office _ Retail _Industrial/Warehouse _Garage (#of cars_) Other(describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 6,093.90 2h'floor: 2nd floor: 6,093.90 `3rd floor: 3rd floor: N/A Basement(habitable space): Basement (habitable space): N/A Total sq ft: Total sq ft: 12,187.80 SQ FT Scope of work to be done: Renovation of Existing Living Facility,see.Title Sheet G-001 for scope of work. l lQ X >2 zko rtagsZ, bl D E [C E 0 V E E !Ek;'11 I TOWN OF QUEEidSBURY BUILDING&CODES Addition/Alteration Application Revised January 2621 1 Office Use Only ADDITION/ALTERATION PERMIT Permit#: APPLICATION Permit Fee:$ Town of QQeensbury 742 Bay Road,Queensbury,NY 11804 Invoice#: P:518-761-8256 www.gueensbury.net Flood Zone? Y N Reviewed By: Project Location: Tax Map ID#: Subdivision Name: PROJECT INFORMATION: TYPE: Residential X Commercial, Proposed Use: Single-Family _TWo-Family —Multi-Family(#of units ) Townhouse Business Office _Retail _Industrial/Warehouse _Garage (#of cars_) Other(describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 6,093.90 2nd floor: 2nd floor: 6,093.90 3rd floor: 3rd floor: N/A Basement(habitable space): Basement(habitable space): N/A Total sq ft: Total sq ft: 12,187.80 SQ FT Scope of work to be done: Renovation of Existing Living Facility, see Title Sheet G-001 for scope of work. Addition/Alteration Application Revised January 2021 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction:$ 75,000 2. Source of Heat (circle one): x Gas _Oil _Propane Solar Other Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? YES x NO Explain: 4. Are there any easements on the property? YES x NO SITE INFORMATION: • Is this a corner lot? _YES x NO • Will the grade be changed as'a result of the construction? YES NO • What is the water source? x PUBLIC _PRIVATE WELL • What type of wastewater system is on the parcel? x SEWER _PRIVATE SEPTIC DECLARATION: 1. 1 acknowledge that no construction shall be commenced prior to the issuance of a.valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans, additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of QOeensbury.After 1 year from the initial application date, 100% of the fee is retained. 3. ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. 1 certify that the application, plans and,supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Fabian Herrera SIGNATURE: DATE: 07/07/2021 Addition/Alteration Application Revised January 2021 e ; CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Fabian Herrera/Dennis Austria Mailing Address; C/S/Z: QUEENSBURY, NY 12804 Cell Phone: ( ) 510-847-8176/415-412-5480 Land Line: ( 415 ) 974-6002 Email: fherrera@mcgarchitecture.com/daustria@mcgarchitecture.com Primary Owner(s): Name(s): WELLTOWER PEGASUS VIDAURRI MANAGEMENT GROUP, LLC Mailing Address, C/S/Z: 6241 Sherbert Dr, North Richland Hills,TX 76180 Cell Phone: 860 ) 680-5449 Land Line: 972 ) 400-2042 Email: aysha.moore@vidmg.com. ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): TBD Contractor Trade: TBD Mailing Address, C/S/Z: TBD Cell Phone: TBD Land Line: TBD Email: TBD "Workers' Comp documentation must be submitted with this application" • Arch itect(s)/Enei nee r(s): Business Name: MCG ARCHITECTURE Contact Name(s): Fabian Herrera/Dennis Austria Mailing Address, C/S/Z: 7100 E. PLEASANT VALLEY RD, SUITE 320, CLEVELAND, OH 44131 Cell Phone: ( ) 510-847-8176/415-412-5480 Land Line: 415 ) 974-6002 Email: fherrera@mcgarchitecture.com/daustria@mcgarchitecture.com Contact Person for Compliance in regards to this project: Fabian Herrera/Dennis Austria Cell Phone: ( ) 510-847-8176/415-412-5480 Land Line: 415 ) 974-6002 Email: fherrera@mcgarchitecture.com/daustria@mcgarchitecture.com Addition/Alteration Application Revised January 2W1 Rec'd TCCo 09.17.21 ACTS ENGINEERING June 3,2021 To John Schmid Project Welltower-Pegasus MCG Architecture 250 Sutter St., Suite 500 San Francisco ,CA 94108 Re MEP Design Criteria (415)974-6002 The following report outlines the MEP design criteria for Welltower-Pegasus facilities. SECTION DESCRIPTION 61 MECHANICAL 02 PLUMBING 03 ELECTRICAL Applicable Criteria, Standards,and Code • 2020 New York State Mechanical Code • 2020 New York State Plumbing Code • 2020 New York State Energy Code • National Electrical Code 2017 Edition 01.MECHANICAL A. Heating,Ventilation,and Air Conditioning HVAC HVAC Units Replacement: Existing HVAC units that are.15 years old or younger in age to be inspected by a certified mechanical contractor,and to be reused if they are still in good working condition. Otherwise, replace unit like for like. Refer to Table-1,Table-2,and Table-3 for unit specification,as applicable TABLE-1 (ROOFTOP UNITS) CAPACITY GAS PACKAGED PACKAGED HEAT PUMP NOTES ROOFTOP 3 TONS - TRANE YHC036 - TRANE WHC036 - Convertible airflow (ALT)CARRIER - (ALT)CARRIER configuration 48LC 004 50HCQA04 - 2"MERV 13 Filter 400 N.McCarthy Blvd Suite 250,Milpitas;CA 95035 phone:(408)522-5255 fax:(408)522-5260 email:info@acies.net ACIES ENGINEERING 4 TONS - TRANE HC048 - TRANE WHC048 - Outside air damper and hood (ALT) CARRIER - (ALT)CARRIER - Coordinate voltage and 48LC_005 50HCQA05 electrical rating with existing service 5 TONS - TRANE HC060 - TRANE WHC060 - Provide hail guard (ALT)CARRIER - (ALT)CARRIER - Roof curb adapter, as needed 48LC 006 50HCQA06 - New programmable tstats - If gas heating,gas heating 6 TONS - TRANE YHC074 - TRANE WHC074 input option t similar as u (ALT)CARRIER - (ALT)CARRIER - the existing unit 48LC 007 50HCQD07 For 5 tons and above, provide unit with air economizer with 7.5 TONS - TRANE YHC092 TRANE WHC092 FDD control and barometric - (ALT) CARRIER - (ALT) CARRIER relief 48LC 008 50HCQD08 - Contact rep from TRANE Joe Mulligan joe.mulligan@trane.com - Contact rep from CARRIER Borannie Anicete banicete@siglers.com TABLE-2(PTAC UNITS) CAPACITY WINDOW UNIT NOTES 15,000BTUh - TRANE PTHF120 - Coordinate voltage and electrical rating with existing - (ALT)GE AZ65H15 service - New remote controller - Provide with wall sleeve - - Contact rep from TRANE Joe Mulligan joe.mulligan@trane.com TABLE-3(SPLIT HEAT PUMP UNITS) CAPACITY SPLIT UNIT NOTES 24,000BTUh MITSUBISHI - Maximum ref length 100ft(max. 10 bends and max Outdoor: PUZ=P24NHA height difference of 50ft) - . Indoor unit selection to - 2"MERV 13 Filter match existing types: - Coordinate voltage and electrical rating with a. PEAD-A24 existing service - b. PVA-A24 - Reconnect ductworks and outside air intake to the existing system - Provide with drain pan with moisture detector to 36,000BTUh MITSUBISHI shut off unit when triggered: - Outdoor: PUMY-P36NKMU - Provide condensate pump for the primary - Indoor unit selection to condensate drain, as necessary match existing types: - New programmable tstats c. PEFY-P36NMHU - Wind Baffle b. PVFY-P36NAMU - Insulate DX suction&liquid lines - Provide additional heater kit, as applicable. Capacity to match the existing 400 N.McCarthy Blvd Suite 250,Milpitas,CA 95035 phone:(408)522-5255 fax:(408)522-5260 email:info@acies.net ACTS ENGINEERING 48,000BTUh MITSUBISHI - Provide suction line filter, shut off valve,frostat, - Outdoor: PUMY-P48NKMU filter dryer, access port, moisture, and.liquid - Indoor unit selection to indicator. match existing types: - Contact rep from Mitsubishi/TRANE a. PEFY-P48NMHU Joe Mulligan joe.mulligan@trane.com d. PVFY-P48NAMU 54,000BTUh MITSUBISHI Outdoor: PUMY-P60NKMU Indoor unit selection to match existing types: b. PEFY-P54NMHU c. PVFY-P54NAMU New Elevator Split Provide new 2 tons split system inside elevator machine room. Indoor unit to be wall mounted with refrigerant R410A charge. Outdoor unit to be located at either on the ground or at the roof. Refer to Table-4 for unit specifications. TABLE-4(ELEVATOR SPLIT UNIT) CAPACITY SPLIT UNIT NOTES 24,000BTUh MITSUBISHI - Indoor unit to be powered by outdoor unit. - Outdoor: MUZGL24NA - Maximum ref length 100ft(max. 10 bends and max Indoor: MSZGL24NA height difference of 50ft) - New tstats - Insulate DX suction&liquid lines - Provide suction line filter;shut off valve,frostat,filter dryer, access port, moisture, and liquid indicator. - Contact rep from TRANE Joe Mulligan joe.mulligan@trane.com 02.PLUMBING Plumbing Water Heater: Existing water heaters to be inspected and to be reused if they are still in good working condition. Otherwise, replace WH one to one.Water heater replacement to have similar specifications as the existing WH. See Table-5 for Electrical Storage type WH specifications TABLE-5(STORAGE WH) CAPACITY STORAGE ELECTRIC WH NOTES 6-50 gals AO SMITH DEL - Verify voltage and heating element rating with existing WH unit - Provide with secondary drain pan Route T&P relief discharge to exterior with air gap 400 N.McCarthy Blvd Suite 250,Milpitas,CA 95035 phone:(408)522-5255 fax:(403)522-5260 email:info@acies.net ACTr!; ENGINEERING 52-120 gals AO SMITH DEN CAPACITY STORAGE GAS WH NOTES 60-100 gals BRADFORD WHITE EF Series - Verify gas input rating with existing WH Verify the fuel source(natural gas or propane) - Verify the WH venting requirements and to connect to existing Provide with secondary drain pan Route T&P relief discharge to exterior with air gap Plumbing Fixtures: Replacement of any existing plumbing fixture shall be in accordance with water- conserving fixtures requirement.See Table-6 below for the maximum flow rate specifications TABLE-6(INATER CONSERVING FIXTURES FLOW- RATE) WATER-CONSERVING FIXTURES FIXTURE TYPE MAXIMUM FLOW RATE SHOWERHEADS 1.8 GPM @80 PSI LAVATORY FAUCETS-NONRESIDENTIAL 0.5 GPM @6D PSI KITCHEN FAUCETS 1.8 GPM @60 PSI WASH FOUNTAINS 1.8(RIM SPACE(IN)120 GPM @60 PSI) METERING FAUCETS 0.25 GALLONS PER CYCLE METERING FAUCETS FOR WASH FOUNTAINS 0.20ICYCLE(RIM SPACE(IN)@60 PSI) GRAVITY TANK TYPE WATER CLOSETS 1.28 GALLONS PER FLUSH FLUSHOMETER TANK WATER CLOSETS 1.28 GALLONS PER FLUSH FLUSHOMETER VALVE WATER CLOSETS 128 GALLONS PER FLUSH ELECTROMECHANICAL HYDRAULIC WATER CLOSETS 1.28 GALLONS PER FLUSH URINALS(WALL MOUNTED) 0.125 GALLONS PER FLUSH URINALS(FLOOR MOUNTED) 0.5 GALLONS PER FLUSH 03.ELECTRICAL 400 N.McCarthy Blvd Suite 250,Milpitas,CA 95035 phone:(408)522-5255 fax:(408)522-5260 email:info@acies.net ACTr!; ENGINEERING Service&Power Distribution of Power and Data Building Electrical Service: 208V,3phase,4w for Non-Residential and 240/120V, 1-phase for residential units. Electrical Contractor to confirm. Power Requirements: Electrical contractor to verify the capacity of existing electrical service or panelboard prior to adding new load. Avoid overloading existing panelboard.Provide new panelboard as required. • All branch wiring shall be insulated copper conductors in conduit. • Conduit shall be run overhead inside ceiling space. Conduits serving floor outlet items may be run under slab. • Feeder and branch circuit conductors shall be adequately sized to accommodate voltage drop due to excessive lengths. • Provide 208V or 120V circuit as required by this project. • Provide dedicated circuit required for specialized equipment. Coordinate requirements with equipment supplier prior to rough-in. • Grounding type receptacle outlets shall be provided for general use.Receptacle outlets located outside and,in the kitchen,on counters(within 6 ft of sink)and bathrooms shall be GFCI type.Weatherproof cover shall be provided for exterior outlets. • Provide new distribution and branch circuit panelboards to serve new loads as required.Panelboard bus shall be copper.Panelboards shall be of sufficient ampacity to serve the designed loads plus a minimum of 20%additional ampacity to provide for future growth. • Provide Arc Flash Warning Labelling on all panelboards. Prepare arc flash study/analysis. Provide appropriate label per NFPA 70E recommendation. Label will not include PPE requirements or arc flash potential. • Provide dedicated circuits for the new added HVAC equipment.Connect to a panel serving the area.See arch plan for location. • Provide power for new Roof Top units(RTU).Homerun circuit to panel serving the space.Provide wring/conduit and overcurrent protection for complete and operable system. • Reconnect new Rooftop units to existing circuit.See arch plan for site location. • Reconnect elevator control panel of refurbished elevator to existing circuit.See arch plan for site location. • Replace all non-GFCI receptacles at kitchen and bathroom with GFCI type. • Provide power connection for new automatic gate operator.Homerun to panel serving the area.See arch plan for site location. • Connect new clothes washer to existing outlet.Provide new circuit as required. • Connect new clothes dryer to existing outlet.Provide new dedicated circuit as required. • Provide dedicated power connection for a new baking oven as required.Connect to a panel serving the area.See arch plan for site location. • Provide dedicated outlet for new appliance as required.See arch plan for location of new appliance. • Provide new circuit for new refrigerator on breakroom.See arch plan for location. • Provide GFCI outlets at medical room counter.See arch plan for location. • Provide GFCI receptacle outlet at dining area as required.See arch plan for location. • Provide GFCI receptacle outlet for renovated restrooms as required.Reconnect to existing circuit.See arch plan for location. • Provide receptacle outlet for new refrigerator.Homerun circuit to panel serving the area.See arch plan for location. • Reuse existing receptacles for new washer and dryer. • Reconnect relocated walk-in cooler condenser to existing circuit. • Provide power connection for new exhaust fans. • Provide receptacle outlets for new exterior storage building.See arch plan for location of receptacle outlets. Facility Electrical Power Generating 400 N.McCarthy Blvd Suite 250,Milpitas,CA 95035 phone:(408)522-5255 fax:(408)522-5260 email:info@acies.net ACTS ENGINEERING Generator System and Switching: No generator Electrical and Cathodic Protection Lightning Protection: No lightning protection Lighting Submit shop drawing(material submittal)for new LED lamp or luminaire to Architect for review and approval.All new circuit shall be provided,with wiring/conduit and overcurrent protection (as required)for complete and operable system. • Re-lamp all existing fixture with LED. LED fixture shall be compatible with existing housing and trim. Wattage shall be equivalent to existing. Lamp color temperature shall match existing.See arch plan for site location. • Repair broken ground mounted light fixtures in exterior courtyard. Replace with new LED luminaire if repair is not possible.Wattage shall be less or equivalent to existing. See arch plan for site location. • Replace all inoperable exterior lighting around the community,front porch areas. See arch plan for site location. (Provide Bid Alternate). • Replace all inoperable EM lighting. See arch plan for site location. • Provide new lighting for monument sign if required. See arch plan for location. • Re-lamp existing pole lights with new energy efficient LED lamp. If Re-lamping is not feasible, provide new LED luminaire with wattage equivalent. See arch plan for site location. • Provide new outdoor type LED luminaire at two new arbor. See arch plan for site location. • Provide new LED lighting at the dining area. See arch plan for location. • Provide new LED lighting at the kitchen area. See arch plan for site location. • Replace Parking lot lighting with energy efficient LED luminaire. Homerun circuit back to panel serving the area. See arch plan for site location. • Provide LED Lighting for new carport, Homerun new circuit to panel serving the area. See arch plan for site location. • Provide new LED lighting and control for renovated restrooms. Reconnect to existing lighting circuit. See arch plan for location. • Provide new LED lighting at the Gazebo. Homerun circuit to panel-serving the area. See arch plan for Iodation. • Replace existing chandeliers in dining and fire room. Provide dimining controls compatible with light fixtures. See arch plan for site location and specs. • Provide new LED lighting in the north courtyard entry area. homerun circuit to panel serving the area. See arch plan for site location. • Replace all parking lot lighting heads with 150W,5000K LED equivalent with photocell. See arch plan for location and lighting specs. • Provide(1)new 30ft light pole with 2 heads. See arch plan for site location. • Provide new carport LED lighting, 100W,5000°K. Reconnect to existing circuit. See.arch plan for site location. • Replace patio pedestrian lighting. See arch plan for light and pole specs and location. • Replace existing elevator machine room light with New LED luminaire. Reconnect to existing circuit. See arch plan for site location. • Replace outdoor lighting at the gazebo with wall mounted LED. Connect to existing circuit. See arch plan for lighting specs and site location. • Provide new wall mounted LED lighting in the north courtyard entry area. Homerun new circuit to panel serving the area. See arch plan for site location. • Provide lighting for new exterior storage building.See arch plan for location of lights. Low Voltage System(Tel/Data/Access control) • Provide new empty conduit system with pullwire to support low voltage and security system cabling as required. Raceway system shall be compatible with cabling requirements. 400 N.McCarthy Blvd Suite 250,Milpitas,CA 95035 phone:(408)522-5255 fax:(408)522-5260 email:info@acies.net ACTFS ENGINEERING • Provide 120v circuit(with conduit and wring)for low voltage and security system equipment as required. 400 N.'McCarthy Blvd Suite 250,Milpitas,CA 95035 phone:(408)522-5255 fax:(408)522-5260 email:info@acies.net