RC-0588-2020 Office Use Only
ADDITION/ALTERATION PERMIT Permit#:�--D2)C� - 202C)
_® APPLICATION Permit-Fee:$ • ��
Town.of0—yeensbury
742 Bay Road,Queensbury,NY 12804
Invoice#:
P:518-761-8256 wtfm.aueensbury.net 1
Project Location: C� � X
Tax Map ID#: Subdivision Name:
CONTACT INFORMATION:
6 Applicant:
Mailing Address, C/S/Z: (g5f5 I&iP10Gi— C
Cell Phone:_( ) Land Liner _O
Email:
• Primary Owner(s):
Name(s):
Mailing Address, C/S/Z:
Cell Phone:_( ) Land Line: _( )
Email:
❑ Check if all work will be performed by homeowner only
• Contractor(s):
Contact Name(s):
Contractor Trade:
Mailing Address, C/S/Z:
Cell Phone:_( 45tib )A40 — Jfflf2 Land Line:
Email: .
?*list all additional contractors on the back of this form
• Architect(s)/Enaineer(s):
Business Name: ftav15VA .�
Contact Name(s): . 4pyt�
Mailing Address; C/S/Z: CI(,ii!5�6 66tot! N�`� `7
Cell Phone:_ �J )th®��$ Land Line: _( �
Email
: « f.00-1
Contact Person for.Building&Code Compliance: w
Cell Phone:_ Land-Line: _(J _) '744 -( 266
Email:__a4VAq1[eV h G'a .� r`('. 60yyl r
Addition/Alteration Application Revised February.2019
i% I S .
PROJECT INFORMATION:
TYPE: ❑ Commercial VResidential
/Single-Family
ORK CLASS:
❑Two-Family ❑Multi-Family(#of units )
❑Townhouse ❑Business Office ❑Retail ❑ industrial/Warehouse
❑ Garage (#of cars ) ❑ Other(describe )
ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE:
1st floor: 1st floor: 51�
2nd floor: 2nd floor: ft>
3id floor: 3rd floor: —
Basement(habitable space): Basement(habitable space): 14i6
Total square feet: Total square feet: 1100125
ADDITIONAL PROJECT INFORMATION:
1. Estimated Cost of Construction:$ AbOb
2. If Commercial project,what is the proposed use:
3. Source of heat: 9Gas❑Oil❑Propane❑Solar ❑Other Fireplaces need a.separate Fuel
Burning Appliances&Chimney Application
4. Are there any structures not shown on the plot plan? ❑YES ZNO Explain:
5. Are there any easements on the property? DYES eN0
6. SITE INFORMATION:
a. What is the dimensions or ac age of the parcel? Lp•� h64451 �
b. Is this a corner lot? YES ❑NO
c. Will the grade be changed as a,resul of the construction? DYES L�IVO
d. What is the water source? LJPUBLIC ❑PRIVATE WELL
e. Is the parcel on SEWER or a PRIVATE SEPTIC system? 'JG�Jl7 ,
Addition/Alteration Application Revised February 2010
DECLAPATION:
1. I acknowledge that:no construction shall be commenced prior to issuance of a_valid permit and will be
completed within a 12 month period.
2. If thework is not completed by the 1 year expiration date the permit may be renewed, subject to
fees and department approval.
3.. 1 certify that the application, plans and supporting materials are a true and complete statement and/or
description of the work proposed;that all work will be performed in accordance with the NYS Building Codes,
local building.laws.and ordinances, and in conformance with local zoning regulations.
4. 1 acknowledge, that prior to occupying the facilities proposed I, or my agents, will obtain a certificate
of occupancy.
5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all
newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: V"o P-Aftt.. u M&
6
SIGNATURE: - DATE: -
Additlon/Alteration Application Revised February 2019
Residential Plan Review: 1- and 2- Family Dwellings
Y/N/NA (1 of 2)
Two (2) full sets of plans
Over 1,500 sq. ft. requires engineering stamp
Design loads on plans: 115 Wind Floor Loads 40 psf
(North of Rte. 149 60) 50 Ground Snow Load Sleeping Areas &Attics 30 psf
Calculations Decks 40 psf
�( Wind design for lake front properties
Light and vent room schedule
Window schedule with glass size & main doors/AWea#,9-g-4ama9JO-—MVowdwa ..� o
Awij d s/Tempered glass in bathrooms
Door schedule/Main entrance 36" door
Emergency Escape or Bedrooms & Habitable Space
Above-grade: 5.7 sq. ft.
Grade: 5.0 sq. ft.
24" (h)x 20" (w) minimum
44" maximum height above door
'WiM v�i e-e rt ol�e iv c=e 24* rat 2n stIIryiorar2�a o�ve�gr�d
Egress window from basement 5.0 sq. ft.
Floor system sizing per table 502.3.1 -gyp
Residential check ERI or Prescriptive method i f_,S tzAi3
t� All foam plastic on foundation & crawl space covered by 15 minute thermal barrier f�
Driveway length: 300' or more-12' width required/500' or more,turnaround required
Foundation drainage on plans, if required
• j_\5 6" drop in 10' exterior grade IF—V_ ®b k1_�)& TO
Framing cross section for each roof line, vertical fire stopping every 10' where
required/joist spans pg. 127 F -t ooQ,
Ice &snow shield—24" from exterior wall —t
t3 Platforms at exterior doors E
Stairway headroom 6'8"; all stairs 36" width
rLj Stair run and rise s e
Winder run and rise
Spiral stairs meet requirements
Smoke detectors—battery backup & proper location, interconnected DCZ
t,� Bathroom fixtures—proper clearance P D —
Hall width-36" width V_- , wI
Handrails more than four risers on open sides
Railing &guards > 30"/basement stairs included/closed risers more than 4" in height E t 1 w3c_
Safety glazing notes for required areas
Garage fire separation: %" gable end/5/8" under living space &%" on walls/20 min. door
and closer Ob C='
Garage floor sloped
Residential Plan Review Revised March 2018
I. l`
Residential Plan Review: 1- and 2- Family Dwellings
Attic access: gasket seal & R-value equal to roof insulation
Roof over 30"-22" x 30"/Crawl spaces 18" x 24" access c<
Y/N/NA (2 of 2)
Carbon Monoxide detector outside lowest sleeping area, on every level & interconnected
within 15' of sleeping area _ b "
Soil test results, if required EV- v.)
t3 Septic to well or water line separation Q G
All paperwork signed
Note on plans energy saving light bulbs 75%
Blower door test agency paperwork - EAU
Floodplain Permit required -check map: 2 feet above flood elevation
Hurricane clips required
Floors less than 2 x 10 covered by%" gypsum or 5/8" wood panel
Manuals S &J required for heating system. Cold air return hard piped
Separate room for draft HVAC or hot water heater with fresh air
HRV shown and calculations
Baffles at eaves for insulations and knee walls — n
Makeup air for range hood >400 cfm
Continuous header for garage doors to end wall/3" nailing pattern/strapping 0��D �
Chimney rain cap shown for fireplaces
�J Deck hold down shown not less than 4 lags and bolts per table 507.2 1'3'0 VF.IQ
Residential Plan Review Revised March 2018
12/22/020 Mail-huseyin ozdemir-Outlook
�.. Download y�" F ul!screen t0b Print
n�mc
!?�
BISIRA
Y —,, Y -• n.°' - R,. T' - � a ., A avd dS�Y
Wid
.t �" 9
3 �+
e
s01-
Bob
i��
iZ3
O
C)
0
tv
tF7f z b J )vv
ff
,zz-
NGM Insurance Company 01072
AHREWS FULLER ST JOHN &VINCENT Main Street America Assurance Co
1699 KING ST STE 209
ENFIEL-D, CT 06082
01 06
PREMIUM STATEMENT AS OF: 11/26/2020
Account CACP2547Y
Payment Due Date : December -4-6 , 2020
POLTVf HOLDER: YOUR AGENT:
BA'vl',!AM PPOIPERT'i' MAIINNTENANCE LL AHRENS FULLER ST JDHIN &VINCENT CD
TrCHP IELD 7 'PKE 1699 KING ST STE 209
0
N
4400DS�R '-16JG.,E , CT 0652-1511263 ENFI'ELD, CT 06082 a
(D
3
Agency Code Telephone Number 0
C:
060469002 860 668 3960 ZY C)
'"Mmm"OW w•P-,#
A .1h 4fif 40
,it
4W, 0-. ;07, NN
Nil 01
!OW4 AV, f; 4"If 4 Q, 16 Q
�"x X ke 0. ;
jvp t 0 %v, to
IN-
L4
0 00 IV
b,0i;
•
wo .0"
46% #0
sry
#
04,Z'
41 0,
00
we,
Fj 4040
0, A6
0
!AS, wait'-AP,
12/22/2020 Mail-huseyin ozdemir-Outlook
d Dcw,iiI,)ad , Full Sc(ren L,:.,] Print
i� :Yy.S �.:7. � t,'e.-„ 0. :c Y �� ry `fe^.N' �., .. .'� ••"�a`�,�
s'3%':q Y�rr•r BEY_ .,x� t? � I�
p$ Nye(w. shing
a
90
-Windows anddoorsFER'fK1 To CONTACT
_ _ .2Yaxi ti t'
Xli
.q to< .
�r <
"v s
a -
'Mus`'�:%Fw ^if:.Y.r;':T;. �xCaR•� !-i.S.:. ,
`=Y.,
" k
^
Generated by.REScheck-Web Software
Compliance Certificate [FILE
Project 650.Glen Street Alterations
Energy Coder 2018.IECC_ _ 302.11-1-, 2
Location: Glens:Falls, New.York' . RC-0588_2020
Construction Type: Single-family Ozdemir, Huseyin
Project Type: Alteration. . 650 Glen St
Climate zone: 6 (763.5 IHDD) Residential Alteration Permit Date: 1812 S.f.
Permit Number:
Construction Site:_ . - Owner/Agent: Designer/Contractor:,,
650 Glen Street.. Huseyin Ozdemir Ethan P:Hall. .
Queensbury, NY 12804 . 658-Glen.Street Rucinski Hall Architecture
Queensbury, NY.12866: 134 Dix Ave
519 955-7772 Glens Falls;NY 12801
ephall@riycap:rr.com
Compliance: Passes prescriptive requirements for alteration projects
REVIEWED FOR
Envelope Assemblies . ENERGY CaD.E'.COMPLIANCE
Gross Area Cavity Cont.
Perimeter
Ceiling 1: Flat Ceiling or Scissor Truss ---
Exemptlon:Framing cavity not exposed.
Wall 1:Wood Frame,16"O.C. =--
Exemption:.Framing cavity filled_with insulation.
Window 1:Vinyl/Fiberglass Frame;Double Pane with,Low-E 236 0.290 68
Compliance Statement: The proposed building design described here is consistent with the building.plans,specifications,and other
calculations submitted with the permit application.The'proposed building has been desi ned to:meet.the'2018 IECC requirements in
REScheck Version REScheck-Web.and,to comply.with.the mandatory re 1"' Ali- d °REScheck Inspection Checklist.
1�� n or,&2
COP
Name-.Title.. Signa egti�� Date
Project Title: 650 Glen Street Alterations Report date: 09/17/20
Data filename: Pagel of 9
` REScheck Software Version : REScheck-Web
Inspection Checklist
Energy Code: 201.8 •IECC
Requirements:.100.0% were addressed directly in the REScheck software
-
Text in the ".Comments/Assumptions column is provided by the user in the REScheck'Requirements screen.For each
requirement,the user certifies that a code requirement will be-met and how that is documented, or.that an exception --
is being claimed. Where compliance is itemized in a separate table, a'reference to that table.is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID .. .
103.1, ' _;Construction drawings and - i !❑Complies. ;Requirement will be met.
103.2documentation demonstrate- ❑Does Not
[PR1]1 ;energy,'code compliance for the ;Location on-plans/spec:A-
V ❑Not.Observable -
building envelope.Thermal
envelope represented on ❑Nof Applicable
;construction documents. f
103.1, ;Construction drawings and I ❑Complies ;Requirement will be met..
103.2, Idocumentation demonstrate }❑Does Not
403.7 ;energy code compliance for Location on plans/spec:A-
[PR3]1 ;lighting and mechanical systems. J❑Not Observable I1
�g Systems serving multiple i❑Not Applicable
dwelling units must demonstrate i
compliance with the IECC
!Commercial Provisions. . I
302.1, ;Heating and cooling equipment-is;.Heating: Heating: ;❑Complies ;Requirement will be met.
403.7 1 sized per ACCA Manual S.based Btu/hr Btu/he
[PR2]2 ;on loads calculated.perACCA ; Coolie CoolieDoes Not :Location on plans/spec:A-
ej ;Manual J or other methods Btu/hrg. Btu/hr9 ;❑Not Observable 1
)approved by the code official. ;❑Not Applicable
,Additional Comments/Assumptions:
1 High Impact.(Tier 1) 2 Medium.lmpact(Tier 2) 1 3 1 Low Impact(Tier.3).
Project Title: 650 Glen Street Alterations Report date: 09/17/20
Data filename: Page.2 of 9
Section
# Foundation Inspection . Complies? Comments/Assumptions,
& Req.ID
303.2.1 ;A protective covering.is installed to ❑Complies ;Exception:.Requirement is not applicable.
[FO11]z Iprotect exposed exterior insulation. :[]Does Not
,and extends a minirrium,of 6 in.below
grade. ❑Not Observable
❑Not Applicable.
403.9 ;Snow-and.ice-melting system controls;❑Complies. ;Exception: Requirement is.not applicable.
[FO12]2 1'1-nstalled. ❑Does Not
; .
❑Not.Observable
❑Not"Applicable -
Additional•Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium.lmpact(Tier 2) 13 1 Low Impact(Tier 3)
Project Title: 650 Glen Street Alterations Report date: 09/17%20
Data filename: Page 3 of 9
Section Plans Verified . . Field Verified .
# Framing/Rough-In Inspection Value - Value Complies? Comments/Assumptions
& Req.ID
4021.1, :Glazing U-factor(area-weighted U-. U- ;❑Complies ;See the Envelope Assemblies
402:3.1, ;average). jODoesNot table for values.
402.3.3,
402.5 ❑Not Observable
[FR2]1 ONot Applicable
V
303.1.3- ;U-factors of fenestration products i j❑Complies ;Requirement will be met.
[.FR4]1 'are determined in accordance. I❑Does Not
;with the NFRC test procedure or ; . ;Location on plans/spec:A-
!taken from the default table. ❑Not Observable ;1
1❑Not Applicable
402.4.1J ;Air barrier and thermal.barrier I ;❑Complies Requirement will be met.
[FR23]1 ;installed per manufacturer's 1❑Does Not
instructions. 1 Location on plans/spec:A-
a❑Not"Observable ;1
1❑Not Applicable
402.4.3 ;Fenestration that is not site built ;❑Complies ;Requirement will be met.
[FR20]1 ;is listed and labeled as meeting 10Does Not
AAMA/WDMA/CSA 101/13.2/A440 i i
ie ;or has infiltration rates per NFRC i❑Not Observable I
y�400 that do not exceed code ❑Not Applicable
limits. } ;
402.4.5 I IC-rated recessed.lighting fixtures I '❑Complies ;Exception: Requirement is
[FR16]2 ;sealed at housing/interior finish S 1❑Does Not not applicable.
sand labeled to indicate s2.0 cfm a !'!"
leakage at 75 Pa. 4❑Not Observable I
❑Not Applicable
403.3.1 ;Supply and return ducts in attics ,❑Complies ;Exception: Ducts located
[FR12]1 :insulated >= R-.8 where duct is I i❑Does Not completely inside the
3 inches in diameter and>= SS ; building.envelope.
R-6 where<3 inches. Supply and i I❑Not Observable
return ducts in other portions of t' ❑Not Applicable
;the building.insulated >= R-6 for ; 1
;diameter>=3 inches and 114.2 1 .
;for< 3 inches in diameter. j
403.3.2 ;Ducts,air handlers and filter j❑Complies ;Exception: Requirement is
[FR13]1 !boxes are sealed with I❑Does Not !not applicable.
®� ;joints/seams compliant with 1 ;
International.Mechanical Code or ;❑Not Observable
International Residential Code,as i j❑Not Applicable
applicable. ;
403.3.5 j,Building cavities are not used as ( i❑Complies ;Requirement will be.met.
[FR15]3 ducts or plenums. y '❑Does Not
U ; ; i❑Not Observable ;Location on plans/spec:A-
j j❑Not Applicable
403.3.7 ;Ducts declared to.be within the I❑Complies ;Exception: Requirement is
[FR28]3 conditioned space are either 1) ;❑Does Not not applicable.
® }completely within the continuous
air.barrier and within the building I ❑Not Observable
:thermal envelope,2) buried I❑Not Applicable ;
!within ceiling insulation in i
;accordance with Section ! 1
R403.3.6 and the air handler is I 1
;located completely within the
continuous air barrier and within
:the building thermal envelope
!and the duct leakage is<= 1.5 } ;
cfm/100 square feet of
lconditioned floor area served by
,the duct system,or 3)the ceiling I
;insulation R-value installed
against and above the insulated I I
;duct>=to the proposed ceiling i
;insulation R-value,.less the R- f ;
'value of the insulation on the I j
11 High Impact(Tier 1) 2 Medium impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 650 Glen Street Alterations Report date: 09/17/20
Data filename: Page 4 of 9
• Section Plans Verified . Field Verified
# Framing[Rough-In Inspection Complies? Comments/Assumptions .
& Req:ID' Value Value-
403.4 IHVAC piping conveying fluids R R- ;❑Complies ;Exception: Requirement is
[FR17]2 above 105°F or chilled fluids ;❑Does Not :not applicable.
below 55°F are insulated to>_R-
Q) i3. ;❑Not Observable_
❑Not Applicable
403.4:1 ;Protection of insulation on.HVAC. ElComplies". ;Exception: Requirement is
[FR24j1 piping: i❑Does Not not applicable.
IONot Observable.
ONotApplicable
- -
403.5.3 i Hot water pipes are insulated to R ; R- ;❑Comp'lies ;Exception: Requirement is
[FR18]2 2--R-3:. ! ;Does Not not applicable.
J ; ; -]Not Observable
ONot Applicable
403.6 lAiltomatic or gravity dampers are J❑Comp.lies . ;Requirement will be met.
[FR19]2 linstalled on all outdoor air i❑Does Not'
y intakes and exhausts.. Location on plans/spec:A-
❑Not Observable 1-
iONotApplicable
Additional Comments/Assumptions:
1 High Impact.(Tier 1). 2 Medium impact(Tier 2) 3 Low Impact(Tier,3)
Project Title: 650 Glen Street Alterations Report date: 09/17/20
Data filename: . Page 5 of 9
Section Plans Verified Field Verified "
# Insulation Inspection Value - Value Complies? Comments/Assumptions
& Req.ID
303.1 'All installed insulation is labeled I ;❑complies_ Requirement will be met.
[IN13]2 ,or the.installed R-values j - i❑Does Not 1 "
i .
J I provided.
i❑Not Observable I
IE]Not Applicable
402.1:1; ;Wall insulation R-value. If this is a: R= R- ❑complies ;See the Envelope assemblies
402.2.5, 1 mass wall with at least 1/2 of the I❑'Wood._ ❑ Wood ElDoes Not table for values."
462.2.6 ;wall insulation on the.wall
171 :.❑ Mass ❑Not Observable
[IN3]1 ;exterior,the exterior insulation
j requirement applies(FRl_0). ;❑ Steel ❑ steel ;❑Not Applicable.
I
I
303.2 Mall irisulatioh its iristalled-per I ;❑complies ;Requirement will be met.
[IN4]1 manufacturer's instructions. ❑Does Not
Location on plans/spec:A-
❑Not Observable 11
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium,impact(Tier 2) 3 Low Impact(Tier.3)
Project Title: 650 .Glen Street Alterations Report date: 09/17/2.0
Data filename: Page 6 of 9
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
&.Req.ID
402.1.1, ;Ceiling insulation R-Value. R- R- ❑Complies ;See the Envelope Assemblies
402:2.1, ❑ Wood ;❑ Wood ❑Does Not table for values.
402.2.2, ❑ Steel ❑ Steel ;❑Not Observable
402.2.6
[Fill' ❑Not Applicable
;
; I
303.1:1.1,;Ceiling insulation installed per ;[]Complies ;Requirement will be met.
303.2 �manufacturer's instructions. I I❑Does Not
[FI2]1 ;Blown insulation marked every Location on plans/spec:A-
300 ft2. j ❑Not Observable ;l
❑Not Applicable
402.2.3 ;Vented attics with air permeable ( ;❑Complies ;Exception: Requirement is
[F[22]2 insulation include baffle adjacent } El Does Not not applicable.
to soffit and eave vents that +
extends over insulation. i❑Not Observable
i❑Not Applicable
402.2.4 ;Attic access hatch and door Ft- R- ;❑Complies ;Re quirement will be met.
[FI3]1 insulation>_R-value of the j❑Does Not
adjacent assembly. Location on plans/spec:A-
❑Not Observable ;1
. ;❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50= ACH 50 ❑Complies Requirement will be met.
[FI17]1 :ach in Climate Zones 1=2,and I ❑Does Not
<=3 ach in Climate Zones 3m& Location on plans/spec:A-
❑Not Observable
❑Not Applicable
403.3.3 ;Ducts are pressure tested to cfm/100 cfm/100 ;❑Complies Exception:All ducts and air
[FI27]1 .determine air leakage with ft2 ft2 UlDoes Not handlers are located within
either: Rough-in test:Total conditioned space.
;leakage measured with a ; ❑Not Observable
pressure differential of 0.1 inch ❑Not Applicable
;w.g.across the system including
;the manufacturer's air handler
enclosure if installed at time of
;test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g,across the entire,system
including the manufacturer's air ;
;handler enclosure.
403.3.4 ;Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies Exception:All ducts and air
[FI4]1 cfm/100 ft2 across the system or ft2 ftz ❑Does Not handlers are located within
<=3 cfm/100 ft2 without air ;conditioned space.
;handler @ 25 Pa. For rough-in ; ❑Not Observable
tests,Verification may need to ;❑Not Applicable ;
;occur during Framing I.nspection.. j
403.3.2.1 ;Air handler leakage designated ; ;❑Complies ;Exception: Requirement is
[FI24]1 !by manufacturer at<=2%of !❑Does Not not applicable.
;design-air flow.
1.ElNot Observable
❑Not Applicable
403.1.1 ;Programmable thermostats ;❑Complies ;Requirement will be met.
[FI9]2 installed for control of primary '❑Does Not
heating and cooling systems and :Location on plans/spec:A-
initially set by manufacturer to ❑Not Observable 1
I code specifications. j ;❑Not Applicable
403.1.2 ;Heat pump thermostat installed ;Exception: Requirement is
[FI10]2 :on heat pumps. EDoes Not ;not applicable.
❑Not Observable '
;
❑Not Applicable
403.5.1 Circulating service hot water ; i❑Complies Exception: Requirement is
[FI11]2 systems have automatic or i❑Does Not not applicable.
accessible manual controls.
;❑Not Observable
I tlNot Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 650 Glen Street Alterations Report date: 09/17/20
Data filename: Page 7 of 9
Section Plans Verified Field Verified
# Final.Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 ;All mechanical ventilation system; ;,[:]complies 'Exception: Requirement is
[FI25]2 'fans not part of tested and listed l ;❑Does Not 1 not applicable.
HVAC equipment meet efficacy
,and airflow limits per Table i❑Not Observable
11403.6.1. 1❑Not Applicable
403.2 ;Hot water boilers supplying heat '❑Complies ;Exception: Requirement is
[FI26]2 through one-or two heating f I❑Does Not :not applicable.
systems have outdoor setback
control to lower boiler water I❑Not Observable
(temperature based on outdoor l 1❑Not Applicable j
temperature: + j
403.5.1.1 ;Heated water,circulation systems I ;❑Complies_ I Exception:.Requirement is
[F[28]2 'have a circulation pump.The ODoes Not not applicable.
;system return pipe is a dedicated
return pipe or a cold.water supply ❑Not Observable
:pipe.Gravity and thermos- f I❑Not Applicable
;syphon circulation systems are
;not present.Controls for ;
circulating hot water system I !
;pumps start the pump with signal
!for hot water demand within the-
loccupancy.Controls 1 I
automatically turn off the pump 1111 j
;when water is in circulation loop ,
1 is at set-point temperature and
no demand for hot water exists.
403.5.1.2 ;Electric heat trace systems ;❑Complies ;Exception: Requirement is
[F[29]2 ;comply with IEEE 515.1.6r UL 1 t❑Does Not not applicable.
1.515.Controls automatically
adjust the energy input.to the ❑Not Observable
heat tracing fo maintain the `❑Not Applicable
desired water temperature in the
;piping. ( I
403.5.2 ;Demand recirculation water j 1❑Complies ;,Exception: Requirement is
[F130]2 :systems have controls that ;❑Does Not not applicable.
manage operation of the pump
;and limit the temperature of the i❑Not Observable
!water entering the cold water 1❑Not Applicable
piping to<= 1042F.
403.5.4 ;Drain water heat recovery units ;❑Complies ;Requirement will be met.
[FI31]2 ltested in accordance with CSA i❑Does Not
655.1. Potable water side I ;Location on plans/spec:A-
pressure loss of drain water heat i i❑Not Observable ]L
recovery units< 3 psi for j❑Not Applicable ;
;individual units connected to one-
,,or two showers. Potable water- I
!side pressure loss of drain water
heat recovery units<2 psi for I
individual units connected to ;
;three or more'showers. l
404.1 i 90%or.more of permanent iElCornplies Requirement will be met.
[FI6]1 ;fixtures have high efficacy lamps.i ;Does Not
Location on plans/spec:A-
1 I❑Not Observable ;1
iONot Applicable
404.1.1 ;Fuel gas lighting systems have ( ;❑Complies ;Requirement will be met.
[F[23]3 ;no continuous pilot light. ❑Does Not
.0 { ;❑Not Observable Location on plans/spec:A-
❑NotApplicable__ 1
401.3 ;Compliance certificate posted. ;❑Complies ;Requirement will be met.
[F[7]2 ;❑Does Not
l j❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 650 Glen Street Alterations Report date: 09/17/20
Data filename: Page 8 of 9
• Section Plans Verified Field Verified .
# Final Inspection Provisions Value Value. Complies? Comments/Assumptions
&Req.ID
303.3 ;Manufacturer manuals for. ; Complies ;Requirement will be met:
[FI18]3 ;mechanical and water heating !❑Does Not
;systems have been provided.
I❑Not Observable
❑Not Applicable
Addi#ional Comments/Assumptions:
1.11 High Impact(Tier lj 2 Medium Impact(Tier 2) 3 Low Impact(Tier'3)
Project Title: 650 Glen Street Alterations, Report date: 09/17/20
-Data filename: Page 9 of 9
2018 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 0.00
Below-Grade Wall 0.00
Floor 0.00
Ceiling/Roof 0:00
Ductwork (unconditioned spaces).d
Glass&Door Rating U-Factor SHGC
Window 0.29
Door
CoolingHeating&
Heating System:
Cooling System:
Water Heater:
Name: Date:'
Comments
1/10/2021 Load-Calc
Design Indoor Cooling Temp.: 75 IF OZdel[lllr Indoor Heating Temp.: 70 OF
Design Outdoor Cooling Temp.: 85 °F 650 glen street � � -- - sign Outdoor-Heating Temp.:-4 °F
Temp.Difference Cooling:10°F Area: Glens Falls,NY �`� I Y � Temp.Difference Heating:74°F
Indoor Humidity: 150 v ; Grains difference:29 Front Door Orientation[West ^ ' `�- - lock Load
Whole House Block Load
IF
TD:Coo1:10°F Heat:74°FI Sq ft -types 1 and 2 shading Sq.ft.-types 1 and 2 shading Sq.ft:types 1 and 2 Sq.ft_ t
�—Outside Wall North) 1:820 2 Windows -� (1 77 2: -Glass Doors x 1 2: i Doorsf 21
Outside Wall:South' v i
ou 1: 822 2: Windows I 1: 127 2:�® Glass Doors 1 - Doors)
,
a
' 1
2.
Outside Wall:E&Wi 1 836 2: --- - --- - -- -- — - - - - - - - - - - -- - ---
k
i Windows I v '1: 98 2:�'_--_-..-- --,..._.Glass Doors I v 1F 2; _Doors 21__._.._._..___...f
Outside Wall:NE&NWT 1: 2 i windows 1: 2:r I Glass Doors x f 1F 2:� Doors;
-j-
Outside Wall SE&SW; 1 2 Win 2'
dows 2:1 j Glass Doors 1 v j 1 j Doors'
�I
Floor-(linear ft.if slab):1: 2: i Ceiling)1: 938 2: Appliances 3 Fireplaces 0 i
Sky Lights N: S• f E-W: NE-NW: SE-SW: f
i
c Number of People; 5 Conditioned Sq.ft. 1714 I Cubic Ft. 13712
Basement Above grade: Walls 298 Cubic Ft. 1876 Below grade: walls 745 Floor 938 sq.ft.width 23ft.or v below: 2 ft.
is Fresh air recommended:48efm > 80 CFM Construction: average v i Duct system: conditioi d ----------•v average v
` Total Btu's Cooling Sensible Load Latent Load Total Btu's Heating
28516 24913 f 3603 I .56032 '
,
. E
, I
Change State Change City Clear Data Print Comments Change Structures Calculator Size Equipment Help Save Work
Support this site
.� S'ca� �C•�—y_SI
FIL=COPY
Structure types
Btu breakdown Outside Walls 1: Siding or Stucco Rl1 insulation
Sensible FHeatlng Outside Walls 2:
walls 13954 15318 Windows 1:double pane no internal shade
windows 11274 [1974473 Windows 2:
I—�flf
https:/Aoadcalc.net/load.php 1/7
I/10/202 1 manuals
Sizing Calculator based on Manual S
Type: rJl
System Straight Cool w/gas Climate: Heating&Cooling v Elevation: 360 ft.
Load Calculation Data Sizing Results
System Performance at Design Temp,
Cooling- Sensible: 24913 btu's Cooling-Minimum: 28516 btu's i Cooling-Sensible: 27301 btu's
Cooling- Latent: 3603 btu's Cooling-Maximum: 32793 btu!s-
Cooling- Latent: 3603 btu's
Total: 28516 Cooling btu's Heating-Minimum: 56032 btu's Heat-Output: 57000 btu's
Heating-Total: 56032 btu's t Heating-Maximum: 78445 btu's J Totals After Altitude Correction
Sensible Heat Ratio 0.87 Sensible: 27001 Latent: 3779 btu's
Calculate Heat: 56202 Cooling: 30780btA
Straight Cool w/gas heat
Manufacturer's CFM rating at sea level 1088 CFM required to maintain mass flow rate for elevation: 1100
N-
Is system within specs:YES
Clear Load Data Clear System Data Clear All Data Instructions Loadcale Page Balance Point
*Note:The total cooling minimum can be 90%of the total cooling load if the output of the sensible plus 50%.of the excess latent equal at least 90%of the sensible
load. If this condition exists the calculator will detect it but in most cases the cooling minmum will equal the total cooling load.
Gas heating output is estimated to be derated 4%per 1000 ft.by altitude
Disclaimer:
hftps:Yloadcalc.net/sizing.php 1/2