Loading...
CC-0698-2021 iow Office Use Only ADDITION/ALTERATION PERMIT Permit#: CC — O to - APPLICATION Permit Fee:$ ZOO Town of Qcensbury 742 Bay Road,Queensbury,NY 12804 Invoice#: P:518-761-8256 www.gueensbury.net Flood Zone? Y R iewed By: U P r-ei S Project Location: -14 OLA,}I-etS ofi Ls„ke C�u,rg� —W e-Sfi t4 i5 S+V -4-e- Cz o w-1-e_. °I J S Q o.cf+- uweRIn 51 o LA-r-y Tax Map ID#: 2a �. Subdivision Name: '" PROJECT INFORMATION: TYPE: Residential Commercial, Proposed Use: �(,DCV�an Single-Family _Two-Family _Multi-Family (#of units ) —Townhouse Business Office Retail _ Industrial/Warehouse _Garage (#of cars_) Other(describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 1 5 l Cv 2nd floor: V3 A 2nd floor: ^(�� 3rd floor: 3rd floor: fJ Basement (habitable space): Basement (habitable space): Pc Total sq ft: Total sq ft: k15 (< Scope of work to be done: jrnGlvLki'r% Y\�e_v, wo.A VXi sl�,42-S1 n.2.v� 1oof �,► 5 �5 ew 1 i�l��r s �✓� -�-� sa�-�S a�r�� �� � n�� e,�c-�ek7 � s 15 v� . pECo " E SEP 17 2021 TOWN OF QUEENSBURY Addition/Alteration Application BUILDING a CODES Revised January 2021 K. , ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 2. Source of Heat (circle one):_Gas _Oil _Propane _Solar)<Other Fireplaces/inserts need a separate Fuel Burning Appliances &Chimney Application 3. Are there any structures not shown on the plot plan? _—YES )-( NO Explain: . 4. Are there any easements on the property? _YES X NO SITE INFORMATION: • Is this a corner lot? _YES NO • Will the grade be changed as a result of the construction? _YES >�NO • What is the water source? 'x, PUBLIC _PRIVATE WELL • What type of wastewater system is on the parcel? )<SEWER _PRIVATE SEPTIC DECLARATION: 1. 1 acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans, additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: SIGNATURE: DATE: °�•�� Zj Addition/Alteration Application Revised January 2021 r .. c. CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): W 6-irC,C V 1-0 &4o y\. Mailing Address, C/S/Z: \1 fJ aA( exe T t_ 400bc,-7 Cell Phone: (0!!�-_-T ) 7YA - 7744 Land Line: (8-47 ) *5°i - 4? 4 l (P Email: Woo&n*o�n @ VSio�.vLL, cowl • . Primary Owner(s): Name(s): _ Mailing Address, C/S/Z: 2i�0a VJ . .C�an-�rec.1 20 S 5 r L `� a Cell Phone: ( 2_2A ) ZSS - 'OCpoe Land Line: ( 841 ) 7�os - •4-Ce92 Email: @ Gla ices . cpon ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: Land Line: � ) Email: **Workers' Comp documentation must be submitted with this application** • Arch itect(s)/Engineer(s): Business Name: V�J&Arr',-_� Tokm5oy-% Ave�,n i +e_C_'t5 C . Contact Name(s): Wo_rre,�n ,,r oln.vX's,e-►1 Mailing Address, C/S/Z: % -I Q . Gtree-l" SFr-e�'� _ C�a1a �iv�� ZL_ Ceoo 69- Cell Phone: (847 ) 7 74 - "j 7. -4- Land Line: ( 847 ) ;>Sg1 - a &l CP Email: w � vIx n y0h @ W i a--Ck . CmvvI Contact Person for Compliance in regards.to this project: \No rr,--m Tokv,5;e-vti Cell Phone: ( 13,4-7 ) 774 - "77A4 Land Line: ( 0+7 ) -55'7 - R Ce I (P Email: w 0HV150n w � n, ��.L� coov,n Addition/Alteration Application Revised January 2021 COMcheck Software Version COMcheckWeb Interlor Lighting Compliance Certificate Project Information F�L� '�✓��� Energy Code: 2020 NYStretch Energy Code-2018 IECC Project Title: Claire's-Queensbury, NY Project Type: Alteration Construction Site: Owner/Agent: DesignerlContractor: 1415,State Route 9 Warren Johnson Space#122 WJA Queensbury, NY 12804 19 N Greeley St REVIEWED FOR Palatine, iL60067 8473599616 ENERGY CODE COMPLIANCE wjohnson@wjarch.com Allowed Interior Lighting Power A B' C D Area Category Floor Area Allowed Allowed (ft2) Watts/ft2 Watts 1-Retail 1516 0.91 1380 Total Allowed Watts= 1380 Proposed Interior Lighting Power A B C D E Fixture ID : Description/ Lamp/Wattage Per Lamp/ Ballast Lamps/ # of Fixture (C X D) - Fixture Fixture Watt. Retail (1516 sa.ft.) LED 1: 21x2': Other: 1 18 30 540 LED 2:Trck Light: Other: 1 28 17 476 Linear Fluorescent 1: 2'x4' Existing:48"T8 32W(Super T8): Electronic: 3 6 40 240 Linear Fluorescent 2: 2'x2' Existing:48".T8 32W(Super T8): Electronic: 1 1 30 30 Total Proposed Watts= 12.86 'Interior Lighting PASSES Interior Lighting Compliance' - Statement Compliance Statement: The proposed interior lighting alteration project represented;in this document is consistent with the building plans;specifications, and other calculations submitted with this per application.The proposed interior lighting systems have been designed to meet the 2020 NYStretch Energy Code-201 1 CC requirements in COMcheck Version COMcheckW and to comply ith any applicable andatory regwreme s I s ed in the Inspection Checklist. ur wV► Name-Title Si nat re � I N� 035347. 0P•NEB Project Title: Claire's-Queensbury, NY Report date: 09/29/21 Data filename: Page 1 of 5 T COMcheck Software Version COMcheckWeb Inspection Checklist Energy Code: 2020 NYStretch Energy Code - 2018 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed:Where compliance is itemized in a separate table, a reference to that table is provided. Section T- # Plan Review Complies? Comments/Assumptions & Re .ID C103.2 ;,Plans,specifications, and/or ;❑Complies ; [PR4]1 `calculations provide all information I❑Does Not with which compliance can be I :determined for the interior lighting ;❑Not Observable jand electrical systems and equipment :❑Not Applicable ; ,and document where exceptions to ; ;the standard are claimed. Information ; `provided should include interior ilighting power calculations,wattage of; :bulbs and ballasts,transformers and control devices. C405.11 New parking garages and new parking;❑Complies ; [PR38]3 lots powered by the energy services !❑Does Not for a building,and with 10 or greater parking spaces, provide either: 1. :❑Not Observable Panel capacity and conduit for the ,❑Not Applicable future installation of minimum ; 208/240V 40-amp outlets for 5 percent of the total parking spaces and not less than two parking spaces; or 2. Minimum 208/240V 40-amp ; outlets for 5 percent of the total parking spaces and not less than two ; parking spaces. Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Claire's-Queensbury, NY Report date: 09/29/21 Data filename: Page 2 of 5 0 9 Section # Rough-in Electrical Inspection Complies? Comments/Assumptions & Reg.ID C405.2.2. ;Spaces required to have light- ;❑Complies 2 !reduction controls have a manual ;❑Does Not [EL22]1 ;control that allows the occupant to Ieeduce the connected lighting load in ;❑Not Observable is reasonably uniform illumination �,❑Not Applicable ;pattern >=50 percent. C405.2.1, I Occupancy sensors installed in ;❑Complies ; C405.2.1. !classrooms/lecture/training rooms, ;❑Does Not 1 conference/meeting/multipurpose [EL18]1 .rooms,copy/print rooms, ❑Not Observable corridor/tran"sition areas, ;❑Not Applicable i lounges/breakrooms, enclosed offices, 'open plan office areas, restrooms, ; :storage rooms, locker rooms, I ;warehouse storage areas,and other .spaces<=300 sgft that are enclosed ; :by floor-to-ceiling height partitions. Reference section language lC405.2.1.2 for control function in I !warehouses and section C405.2.1.3 Ifor open plan office spaces. ; C405.2.1. ;Occupancy sensors control function in ;❑Complies ; 2 warehouses: In warehouses,the ❑Does Not [EL19]1 'I lighting in aisl,eways and open areas is 1❑Not Observable; controlled with occupant sensors that , .automatically reduce lighting power []Not Applicable ;by 50%or more when the areas are unoccupied.The occupant sensors ; !control lighting in each aisleway I independently and do not control ; lighting,beyond the aisleway being i ; :controlled by the sensor. ; C405.2.1. ;Occupant sensor control function in ;❑Complies 3 !open plan office areas: Occupant :,[]Does Not [EL20]1 ;sensor controls in open office spaces f❑Not Observable; I>=300 sq.ft. have controls 1) I❑Not Applicable configured so that general lighting can PP icable ;be controlled separately in control ; 1zones with floor areas<=600 sq.ft. within the space, 2)automatically turn; off general lighting in all control zones !within 20 minutes after all occupants ; have left the space, 3)are configured iso that general lighting power in each ; ,control zone is reduced by>=80%of I ;the full zone general lighting power i within 20 minutes of all occupants ; ;leaving that control zone,and 4)are I I configured such that any daylight responsive control will activate space ; general lighting or control zone i general lighting only when occupancy i ; ;for the same area is detected. i ; C405.2.2, ti Each area.not served by occupancy ;❑Complies C405.2.2. }sensors(per C405.2.1)have time- ;❑Does Not 1, 3 switch controls and functions detailed C405.2.2. t in sections C405.2.2.1 and C405.2.2.2,i❑Not Observable 2 ;❑Not Applicable [EL21]1 I 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier.3) Project Title: Claire's-Queensbury, NY Report date: 09/29/21 Data filename: Page 3 of 5 i - o Section # Rough-In Electrical Inspection Complies? Comments/Assumptions &Req.ID C405.2.3, Daylight zones provided with ;❑Complies ; C405.2.3. individual controls that control the :❑Does Not 1, {lights independent of general area C405.2.3. ;lighting within daylight zones in the ;❑Not Observable 2 ifollowing spaces: 1.Spaces with a ;❑Not Applicable ; [EL23]2 ;total of more than 100 watts of general lighting within sidelit zones ;complying with Section C405.2.3.2. ;General lighting does not include ; lighting that is required to have i I ;specific application control in accordance with Section C405.2.4.2. Spaces with a total of more than 100 I watts of general lighting within toplit (zones complying with Section 1C405.2.3.1 C405.2.3.3.See code section Daylight responsive ;control function and section ; C405.2.4 ''Separate light!ng.control devices for ;❑Complies ; [EL26]1 ;specific uses installed per approved ❑Does Not lighting plans. ;❑Not Observable; j ;❑Not Applicable C405.2.4 ;Additional interior lighting power- ;❑Comp lies ; [EL27]1 l allowed for special functions per the T❑Does Not ;approved lighting plans and is ; ; ;automatically controlled and ,❑Not Observable, 'separated from general lighting. , ❑Not Applicable C405.3 !Exit signs do not exceed 5 watts per ;❑Complies [EL6]1 face. ;❑Does Not ❑Not Observable; ❑Not Applicable C405.6 Low-voltage dry-type distribution ;❑Complies ; [EL26]2 electric transformers meet the ;❑Does Not ;minimum efficiency requirements of ' ' Table C405.6. ❑Not Observable; ❑Not Applicable C405.7 ;Electric motors meet the minimum ;❑Complies [EL27]2 jefficiency requirements of Tables T❑Does Not .C405.7(1)through C405.7(4). ❑Not Observable; Efficiency verified through certification; , under an approved certification ;❑Not Applicable ; program or the equipment efficiency ; ratings-shall be provided by motor ; i manufacturer(where certification programs do not exist). C405.8.2 ;Escalators and moving walks comply ;❑Complies ; [EL28]2 ;with ASME A17.1/CSA B44 and have :❑Does Not automatic controls configured to I reduce speed to the minimum 1❑Not Observable i permitted speed in accordance with �❑Not Applicable ASME A17.1/CSA B44 or applicable ; local code when not conveying ; I passengers. C405.9 ;Total voltage drop across the ;❑Complies [EL29]2 I combination of feeders and branch 1❑Does Not ;circuits<=5%. !❑Not Observable; t ;❑Not Applicable Additional.Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Claire's-Queensbury, NY Report date: 09/29/21 Data filename: Page 4 of 5 i i Section # Final Inspection Complies? Comments/Assumptions &Re .ID C303.3, Furnished 0&M instructions for ;❑Complies C408.2.5. systems and equipment to the ;❑Does Not 2 building owner or designated i [FI17]3 representative. ❑Not Observable ❑Not Applicable ; C405.4.1 ;Interior installed lamp and fixture ;❑Complies ;See the Interior Lighting fixture schedule for values. [FI18]1 :lighting power is consistent with what 1❑Does Not !is shown on the approved lighting Observable; :plans, demonstrating proposed watts , , :are less than or equal to allowed :❑Not Applicable ; watts. C408.1.1 ;Building operations and maintenance ;❑Complies [F157]1 `documents will be provided to the 1❑Does Not owner.Documents will cover ;manufacturers' ' ❑ Observable: information, ' Not Obble; ; , ;specifications, programming .❑Not Applicable !procedures and means of illustrating ; ;to owner how building,equipment and ;systems are intended to be installed, maintained,and operated. C408.3 :Lighting systems have been tested to ;❑Complies ; [FI33]1 ensure proper calibration,adjustment,',❑Does Not ;programming, and operation. ❑Not Observable; ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 12 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Claire's-Queensbury, NY Report date: 09/29/21 Data filename: Page 5 of 5 FIRE MARSHAL'S OFFICE Town of Queensbury 742 Bay Road, Queensbury, NY 12804 "Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW FILE COPY Claire's 1415 Route 9, Suite 122. CC-0698-2021 9/20/2021 The following comments are based.on a review of submittals: • Verify fire extinguisher location and inspection . . • Location of exit/Emergency.lighting appear adequate. Function test will be required • Lock./ latches shall comply with Chapter 10 of 2020 IFC. Verify paths of egress Verify storage • Verify.clearances to electrical-service panels CO detection is required, if source is present 9 Knox Box key-is required • NFPA 72 letter of compliance required.for any alterations to the fire .alarm system. • NFPA 13 letter of compliance required for any modifications to the sprinkler system Contractor to exercise caution'and provide protection for all fire alarm and sprinkler devices, during constructio Michael J Palmer Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.riet Fi r e Marsha 1 's Office Phone: 518-761-8206. • Fax: 518-745-4437 firenmrshal@queensbunt.net zvzvzv.queensbunj.net