2003-394 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761.8201
Community Development-Building&Codes (518)761.8256
f U`r- .RL,,T.L IFICATE fv".rr OCCUPANCY
PennitNumber. P20030394 Date Issued; Monday,January 10, 2011
This is to certify that work requested to be done as shown by Pen nit Number p20030394
has been completed.
Location; 106 CHESTNUT RIDGE Rd
Tax Map Number. 523400-290-000-OaOI-024-000-0000
Owner. DEBORAH S O'REILLY
Applicant; ARTHUR&MELISSA VANDERMINDEN
TEs structure may be occupied as a;
Garage-3 Cars Detached By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of occupancy DOES NOT relieve the
property owner of the responsibility for compliance with.Site Plan,
Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals,
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: P20030394 Application Number: A20030394
Tax Map No: 523400-290-000-0001-024-000-0000
Permission is hereby granted to: ARTMTR a TVMLISSA VANDERNUNDEN
For property located at: 106 CHESTNUT RIDGE Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance.
Type of Construction Value
Owner Address: ARTHUR&MELISSA VANDERNE Garage-3 Cars Detached $18,500.00
106 CHESTNUT RIDGE Rd QUEENSBURY,NY 12804 Total.Value $18,500.00
Contractor or Builder's Name j Address Electrical Inspection Agency
Plans&Specifications
2003-394
900 SQ FT 3-CAR DETACHED GARAGE AS PER PLOT PLAN SPECIFICATIONS
$90.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: 2005
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
T TOWN OF QUEENSBURY .
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development,-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: P20030394 Application Number: AL20030394
Tax Map No: 523400-290-000-0001-0247.'-000-0000
Permission is hereby granted to: ARTHUR&MELISSA VANDERMINDEN-
For property located at: 106 CHESTNUT RIDGE Rd
in the Town of Queensbury,to constrict dr"place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NY$Uniform Building Codes and the Queensbury Zoning
Ordinance.
Type of Construction Value
Owner Address: ARTHUR&MELISSA VANDERME Garage-3 Cars Detached $18,500.00
106 CHESTNUT RIDGE Rd
QUEENSBURY,NY 12804 Total Value $18,500.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2003-394
900 SQ FT 3-CAR DETACHED GARAGE AS PER PLOT PLAN SPECIFICATIONS
$90.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,July 02,2004
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Qucensbury before the expiration date.)
Dated at the of Qu sbury;AVi " ednesday,,July 02,2003
SIGNED J for the Town of Queensbury.
Director of Bua g&Code Enforcement
Building Permit Application
Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury,NY
(518)761-8256
A permit must be obtained before beginning construction. Permit File No. ",A
No No inspection will be made until applicant has received a Fee Paid $ =c
valid building permit. All applicants' spaces on this Roe.Fee Paid $
application must be completed and must appear on the
application form. Reviewed By:-e-a V E D
Applicant: f �rg ►62 •.�vt.s Owner: .R-dot..,. Q 6 2003
Address: Z ;. � Address:
e„a ,E,,,�. • if/y'/��dy _ TOWN OF QUEENSBURY
Phone#G00 Phone#( ) - BUILDING AND CODE
Property Location: Lot Number: / House Number.,&,: / je4,t, e,-
Subdivision Name: Tax Map Number: .9-9n_d0-!-at/
o New Building: residence /commerrcial 'Estimated Market Value of Construction:
n Addition: residence/ commercial If an Addition,what will use of new addition be?
a Alteration: residence/ commercial
a No change to exterior size: residence I com'1
a Other work(describe )
Check Occupaneylnformation 1' moor 2° Floor Other floor Total
Below sq ft. sq.ft. sq.ft. Square Feet
a Single family dwelling
o Two family dwelling
a Townhouse
a Multifamily dwelling
#of units
a Office
o Mercantile
a Maaufactutin
0 1 car detached garage
0 2 car detached garage
0 3 car detached garage. Qt�
a 1 car attached garage
o 2 car attached garage
a 3 car attached garage
a Storage building-
commercial
a Storage building-
residential
a Other
What is the proposed height of the structure feet inches
Will any second-hand or ungraded lumber be used? If so,for what? AVO
Type of Heating System: electric/ oil / gas/wood /forced hot air/ baseboard!other:
Number of Fireplaces to be installed — _ 0 Number of Woodstoves to be installed_/�
List below the person(s)responsible for supervision of work as regards to building codes:
Name Address .Phone Number
Builder
Plumber
Mason
Electrician
Aeclaratian: please sign below niter you�have
`c efullysead the statement:
To the best of my knowledge the statemen'&bon d in this application,together with the plans and specifications
submitted,are a true and complete st teme t of all proposed work to be done on the described premises and that all
provisions of the Building Code;the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied
with,whether specified or<a`oted,-and that such work is authorized by the owner. Further,it is understood that I/we shall
submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning
A�trator or.Di ectoz of Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual
locatio'h o� f aalll.n won construction.
SignatureL� owner,owner's agent,architect,contractor
�,
Queensbury Building.& Code Enforcement - Residential * l spection
Office No. 618 761-8266 Arrive: am m
o { ) .
Date Inspection request received: Inspector's 16itia d
NAME: V Q� DAT�T: : �.
LOCATION: "=_� %f
TYPE OF STRUCTURE: _
Comments:
Yes o NIA
4" Building Number Address visible from road
Chimney Height J"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers VAI
Guards at stairs deckspatios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 Inches or more '
Handrail Termination at Newell Post or Wall ✓
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracin` /Handicapped Ramp Compliant
Grade awav from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut=off exposed I regulator 18 inches above grade
Interior privacy I trim/doors I main entrance 36 inches
Bathroom I Kitchen watertight
Safety glazing/Window in stairwells safe lazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Craw1Spaces 18 inch x 24 inch access,l sq.ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency ress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
eratin
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'A"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door I door.closer
Duct work Sealed properly 10
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan /
A
rereaker in Bedrooms
Pine Bondin `V�
tic System I Sewer r% t. Ins ction Sticker
Variance required
Certification,if re aired
ue C/C or C 10 1 Temporary/Permanent
L:1Building&Codes Forms\Building&Codes\lnspectlon Forms\Residentiai Final Inspection Form_revised 100405.doc;Revised
January 7,2008;Revised 6/26/08
Queenebury Building. od nfottement a Residential Fi i Ins ectiOn
Office No. (518)761-8256 r Arrive: a P` r /pm
Date Inspection request received: {{ inspectors Initials:
NAME: i t0lP� IT#:
LOCATION:
TYPE OF STRUCTURE:
commemt&
Yes No NIA
e Building Number Address visible from road Z l
Chimney,Height/V Vent/Direct Vent Location
Fresh Air intake r 1
3 InchPlumbin Vent through roof minimum 6 inches ' ne W
Roof Complete/Exterior Finish Complete
Platform at all exterior doors Handrail 4 or more risers 6 - 0
Guards at stairs deckspatios more than 30 inches above grade,.;..
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 Inches or more
Handrail Termination at Newell Post or Wail
Interior/Exterior Railin s 34 inches to 38 inches
Deck Bracing/Handicap ed. Ramp Compliant 'PLF.*'E. CZ OT,C1,.\
Grade awa from foundation 6 inches with 10 feet
6 inch clearance to sill plate ��t�... � ' \t.SG
Gas Valve shut-off ex used 1 regulator 18 inches above grade
Interior dvac /trim/doors/main entrance 36 inches ! NeA�! Q 0���,�v�
Bathroom t Kitchen watertight b
Safe lain /Window in stairwells safe Pain
Interior Smoke Detectors/Carbon Monoxide Detectors LkA . . N''
Every level: Even}Bedroom: jP® ,
Outside every bedroom area:
Inter Connected: Batte backup:
C%ag � � f
Attic acdess 30 inches x 22 inches x 30 inches hei ht in accessible area
Crawl S aces'18 inch x 24 inch access, 1 sq.ft.--I50 s .ft.vents
Bathroom Fans,if no window V-43i �
Plumbing fixtures
Foundation.insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency ress below qrade
Gas Furnace shut-off within 30 feet or within line of site -3ta° kk bk_k
Oil Furnace shut-off at entrance to furnace area
Funcace/Hot Water Heater operating
`1-
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum W Gypsumisr iC
Basement stairs dosed rise>4 inches
tiara a Floor Pitched L7C� w
Garage fireproofing/%hour fire door/door closer ��
Duct work Sealed ro eri
Gas Loge in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Are Fault Breaker in Bedrooms
Flex.Gas Pipe Bondingp �� s
As Built Se tic System/Sewer Dept.Inspection Sticker �--
Site Plan l Variance,re wired C-itt _V \\moo kjwi�a
Flood Plain Certification,if required
Oka to issue C 1 C or C 10 Tern ora /Permanent I
L:1Building&Codes Form"uilding&Codesllnspection FormsWesidential Final Inspection Form rovised_100405.doc,Revised
January 7,2008;Revised 6/26/08 "
t
Queensbury Building & Code Enforcement - Residenti Fi Inspection
Office No. (518)761-8256 Arrive: a epart: a p
Date Inspection request r 'ved: Inspector's Initia
NAME: IT
LOCATION: ATE: LA
TYPE OF STRUCTURE: 77
Comments-
Yes No
e Buildft Number Address visible from road
-
Chimney Height/"B"Vent/Direct Vent Location 6op
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,p2bLos more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Walls\
Interior0derior Railings 34 inches to 38 inches •����
Deck Brawn /Handi Ra Compliant Com\6� , 1
Grade awe from foundation 6 inches with 10 feet (� � 1 G� i �� t
6 inch clearance to sill plate 1 )w 0 'bv\� E7\� oO
Gas Valve shut-off exposed/ ulator 18 inches above grade _
Interior privacy 1 trim/doors I main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazirg/Window in stairwells Wfety glazingL\ \AkC\A lb Pt Q)b\�-\
Interior Smoke Detectors/Carbon Monoxide Detectors r �
Every level: Every Bedroom: LQ
Outside every bedroom area:
Inter Connected: Battery&cku :
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access,l sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency ress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area '
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Vale s installed I Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum VV!Gypsum
Baserinent stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Se tic System/Sewer Dept. Inspection Sticker
Site Plan I Variance required
Flood Plaiin Certification,if re uired
Okay to issue C I C or C 10 Temporary/Permanent
LABuilding&Codes Forms\Building&Codes\lnspec don FormMesidential Final Inspection Form revised 100405.doc,Revised
January 7,2008
. t c — —..
• � � —x,.
t �
• a v. - ,.
v qV � '
' � 5r _
' I, �
n J a t ♦� � !
..�. �� �#
n 1
t" +.1.
�1
. e�.. ''-
.. � ,1 .. •
Queensbury Building & Code Enforcement - Reside ti al Inspection
Office No.(528)762-5256 Arrive:- � � e .
Date Inspection request received: _ Inspector's Init' s �'
NAME: ~ .
LOCATION: D P IT#: � �
TYPE OF STRUCTURE:
Comments
Yes �o N/A 7k /OS—
Building Number/Address visible from road ,
Chimney Height/"B"VentJDirect Vent Location J
Fresh Air Intake I���i�-� .
3 inch PlumbingVent through roof minimum 6 inches ���.��/ �� �.0 ����
Roof Complete/Exterior Finish Com lets
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more ,1
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails P,stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet M --
6 inch clearance to sill plate �
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety lain /Window in stairwells safety lain
Interior Smoke Detectors:
Every level:— Every Bedroom:
Outside every bedroom area:
Inter Connected: Batterybackup: '
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area,
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .&vents
Bathroom Fans,if no window 51-A l o
Plumbing fixtures
Fj2-
oundation insulation a
Floor truss,draft sta_pping finished basement 1,000 s .ft. -
Emergency egress below Ea4e
Gas Furnace shut-off within 30 feet,or within line of site � �t�--
Oil Furnace shut-off at entrance to.furnace area
Furnace/Hot Water Heater operating
t
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110 _31
Enclosed Stairs Sheetrock Underside minimum Iz"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/a hour fire door I door closer
Duct work Sealed properlyJ
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Surve Plot Plan
As Built Se tic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required r "'
Flood Plain Certification,if required
Okay to issue C/C or C/0 r Tem or /Permanent
L:1Building&Codes FormslBuilding&Codes\Inspection Forms1esidential Final Inspection Form revised 100405.doc
i
Queensbury Building & Code Enforcement - Residential Final Inspection
Offiee.No.(51$)761=8256 Arrive: �/S aaml part: am/pm
Date Inspection request received: Inspector's Initials:
NAME: jti. PERMIT#:
LOCATION: ZEc DATE:
TYPE OF STRUCTURE:
Comments
t Yes No N/A
Building Number/Address visible from road �� r
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors PCGuards at stairs,decks, atios more than 30 inches above ade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more /
Handrail Termination at Newell Post or Wall Y
Interior/Exterior Railings 34 inches to 38 inches C,q&0 is Al4L
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill late
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches f 1
Bathroom/Kitchen watertight
r� /�
Safe glazing/Window in stairwells safetyl ,A
Interior Smoke Detectors: .�, W 5r
Every level: Eve `Bedroom: "1�1�1 L
Outside every bedroom area:
Inter Connected: Batte backu :
Carbon Monoxide Detector f Jz l
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Gara a fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Los in Sealed or Glass Enclosure or
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/D Temporary/Permanent
LABuilding&Codes FormslBuilding&Codes\Inspection Forms\Residential Final Inspection Form-revised-1 00405.doc
jam
.�� i
M
5
Framing I Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received: J 123 O S"
Queensbury Building&Code Enforcement Arrive: am/
: pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: b2YUl l 1.(T�cl� PERMIT#: y?941
LOCATION: (p(p INSPECT ON:
TYPE OF STRUCTURE: 3C,&g=
Y N NIA COMMENTS
naming �G�
JacVtuds I Headers
ing 1 Bridging e k �7Et hangers ��
Zack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2(w) 16 gauge(8) 16D nails each side
Draft-stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side '/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHeming,,vay\Building.Codes.Inspection.FORMSTFraming Firestopping Inspection Report.doc January 28,2003
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date In ectio reque r
Queensbury Building&Code Enforcement
Arrive:
r pa a p
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT#: 6 3 39
LOCATION: INSPECT ON:
sle ,p
TYPE OF STRUCTtRE:'-"
S- a—a
Y N N/A COMMENTS
U-'Framing
Jack Studs/Headers u�oc)v) C)
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft, 8 in. -Z;
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls V/
Metal Strapping for Notches Top Plate
I V2 (w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield.24 inches from wall
Fire separation 1, 2,3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side !/2inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf Eade
LAS ucHerningway\13 u i Id ing.Codes Anspection.FORM S\Franni ng Firestopping Inspection Report.doc January 28,2003
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building& Code Enforcement Arrive: am/ Depart: W J� am/pm
- W
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT#: 3
LOCATION: LQ C J\aC�kD 4 At LS rbe_ INSPECT ON:
TYPE OF STRUCTURE:
Y N' N/A
Framing COMMENTS
Jack Studs 1 Headers �f���i
Bracing Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in. do
Notches/Holes/Bearing Walls M(it
Metal Strapping for Notches Top Plate
1 V2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anc Bolts 6 ft. or less oncenter
e and snow shiel 4 inc es frqm wall
Fire separation 1, 2,3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side V2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in, (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LASueHerni n gway\B ui Iding.Codes.In specti on.FORM STrarning Firestopping Inspection Report.doc January 28,2003
Framing/ Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p i+ADepart: ` am/pm
742 Bay Road,Queensbury,NY 1.2804 Inspector's Initials:_1 f�
NAME:- I/v �,�/lA PERMIT#:
LOCATION: C �/LI a -it26 C t<6� INSPECT ON:
TYPE OF STRUCTURE:
Y N t N/A COMMENTS
Framing
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 3 6 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %z(w) 16 gauge(8) 16D nails each side r- t
Draft stopping 1,000 sq.ft, floor trusses
char Bolts 6 ft.,or less on center
Ice and snow shield 24 inches from wall 2Ae-K lj f zz;pe -- 0� �-
` !d
Fire separation 1, 2, 3 hour
Fire wall 2,3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%z inch or 5/8 inch Type X
Garage side 5/8 inch-Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LASueHemingway\Building.Codes.InspectionTORMSWraming Fire-stopping Inspection Report.doc January 28,2003
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received: qht,104 A--30,0', IIJ11/11
I (I I
Queensbury Building& Code Enforcement Arrive: am/ Depart: tjj�/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials: /V
NAME: PERMIT#: za,3-3q4
LOCATION: iOb INSPECT ON: A104 jg-�,00'
TYPE OF STRUCTURE:
Framing Y N N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 V2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side Y2inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SucHeming-,vay\Btiildiii-..Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
Rr
Foundation Inspection Report 0
Office No. (5 18)761-825 6 Date Inspecution reque ce, e
Queensbury Building&Code Enforcement Arrive: a in D e, pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initia
NAME: IT#: D
LOCATION: 0 AN�1_�_JCM R SPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
n:g_s
Piers
Monolithic Slab
Reinforcement in-Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil of for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior 1 Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\SueHemingway\Building.Codes,lnspecdon.FORMS\Foundation Inspection Report.doc January 28,2003
RECEIVE®
JUN 0 6 2003
TOWN OF QUEENSBURY
El-
BUILDING AND CODE
9NUSIX3
r /
r
39a12i inN1S3NO