2003-421 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 ;(518)761-8201
Community Development-Building&Codes .(518)761-8256
Y
CERTIFICATE 01F OCCUPANC
Permit Number: P20030421 Date Issued: Wednesday,December 10,2003
-This is.to.ceri4-.that work requested to be done as shown by Permit Number- P20030421
4` has been completed. -
TaxMap Number: 5,23400-2�96.008-0001'028.002-0000
Location: 18, WAVERLY PI
Owner: NIICHAEL$GROUP LLC THE
. .,ns
Applicant: MICHAEL$.GROUP LLC THE
This structure may be occupied as a:
By Otder of Town Board
Garage-2 Cars Attached TOWN OF QUEBNSBURY
Townhouse
Nectot of Building&Cod Nor meat
4
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20030421 Application Number: A20030421
Tax Map No: 523400-296-008-0001-028-002-0000
Permission is hereby granted to: MICHAELS GROUP LLC THE
For property located at: 18 WAVERLY P1
in the Town of Queensbury,-to construct or place
at the above location in accordance with application together with plot plans and other information heteto, filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: MICHAELS GROUP LLC THE Garage-2 Cars Attached
10 BLACKSMITH Dr Townhouse $155900-00
MALTA,NY 12020-0000 Total Value $155,900.00
Contractor or Builder's Name Address Electrical Inspection.Agency
MICHAELS GROUP
SUITE 1
10-BLACKSMITH Dr
MALTA.NY 12020
Plans&Specifications
2003-421 LOT 51 HSE#1 8 WAVERLY PLACE
1319 SQ FT TOWNHOUSE WITH 2-CAR ATTACHED GARAGE AS PER PLOT PLAN
SPECIFICATIONS
$224.66 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,June 19,2004
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at di_P'rownN_r'Q:fi r ursda June 19,2003
70l SSIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
Building Permit Application
Town of Queensbury—Dept of Community Development,.742 Bay Road, Queensbury,NY
(518)761-8256
A permit trust be obtained before beginning construction. Permit File No. C-
No inspection will be made until applicant has received a lice Paid $
valid building permit. All applicants' spaces on this Rec. Fee Laid $
application must be completed and trust appear on the Reviewed By:
application forsm. 11
Applicant:��� �"1tL�f1'A { _ Owner: R C C__ p�
Address: IC Aw Address: �1
Phone#(51e) Phone# (_) - r0` � <7Q3
OF
Property Location: Lot Number:�_l House Number ( �> P�_e-c.>�
Subdivision Name: es�\&,�lz►c _ Tax Map Number:
New Building: residence /commercial Estimated Market Value of Construction: $
❑ Addition:, residence J convmercial If an Addition, what wi11 use of new addition be?
❑ Alteration: residence/ commercial
❑ No change to exterior size: residence/coni'l
❑ Other work(describe )
Check Oeeupatlleylnforination 1"Floor 2" Floor other noor Total
Below sq.ft. sq.ft. sq. ft. Square Feet
❑ Single family dwelling
❑ Two famil .dwelling f
K Townhouse
❑ Multifamily dwelling
#of units
❑ Office
❑ Mercantile
o Manufacturin
❑ 1 car detached garage
❑ 2 car detached garage
❑ 3 car detached garage
❑ 1 car attached garage �/}
X2 car attached garage
❑ 3 car attached garage
❑ Storage building-
commercial
❑ Storage building-
residential
❑ Other
Will any second-hand or ungraded lumber be used? If so, for what?
Type of 11cating System: electric/ oil / gas)wood /forced hot air/ baseboard/other:
Number.of 17h-enlaces to be installed Number of Woodstoves to be installed N.
List below the person(s)responsible for supery ssion of work as regards to building codes:_ v
Narne Address Phone Number
.lam _
,�Lrts.ie2-
Plunlbel' _ C,
Mason `"'.tom. 3 < 4ZI— 55k1l'3
Electrician � "11-992`Z
Dcclaratiotl: please sign below after you have carefully read the statement:
To the best of my knowledge the statements contained in this application,together with the plans and specificatious
submitted,are a true and complete statement of all proposed work to be done oo the described premises and that all
provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work sliall be complied
with,whether specified or noted,and that such work is authorized by the owner. Further, it is understood that I/we shall
submit,prior to a Certificate of Occupancy or Certificate or Compliance being issued,as requested by the Zoning
Administrator or Director of Building and Codes,an As Bititt Sttrt=ep by a licensed surveyor;drawn to scale,showing actual
location or all new construe" It.
Signature:_ ��;ii%-`7 - owner,owner's agent,architect,contractor
~b x
moQN N H W � a
N� H� aQ s>
wwx�a zu�w � �
O:"H z
aom dw H z w
a a
0 Nc a i vw
U'Cal CD M I
0IA H H ! H
0z z" � a W
z w z U •
�a �aa a Qa w z a4u
z9 a W 0 H H W a H 0 a
n a � �,{} a W W x � � a a N W N z W a
] N a N !� N N " U ' p 0
x w z a 0 w Q a 0 w x x a z 0
0 U z w x H o N 0 a H CA H H U H 4 4 9 0
o qum P H $ N ZHU ax � � � aHaaU
o ] z z w H z N W U �< N W A a a w W
U U = w H H > H w w a
W H z m > W 0 a z N N W H N 9 W W W W U > U
a N 0 x 4' o Z H a � a' �' H a a a W z a v�
/+ t t yU ray /a+ 'n > H /a� /0� +,#�yi r� boy /off 4 a a a 9 n N
" z 0 W U H � z 0 0 U 0 0 W �y 0 0 0 r4 W N N H
w H H 0 z4 W H z H z w H a A z Q Q N 0 U U U a
> H Ha Z M H H W x 0 xV, N H W H H H a a 0
i H W W W W H0 z w W H H 0 z W U W W a W H H H Q Q Q 4 W 4 H
3 9 U H a 00 H 0 0 �+ a 0 ] H 0 L� H t� H H z z z M w H x
0 a o z x a 0 �s w w a 0 z H H H w H ,� t.
Q z a Q H WH U a x x. W w H N W U I� . w w a x x x w N w 0
1
Residential Final Inspection ✓ /J
Office No. (518)761-8256 Date Inspection request eived:
Queensbury Building&Code Enforcement Arrive: a a In
742 Bay Rd., Queensbury,NY 12804 Inspector's Initial
k
NAME: Mk C,{n Pf rcA.R, OTIT#-
LOCATION: v-t'� Vk Q
TYPE OF STRUCTURE:
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent throw h roof
Roof Complete
Guard 30 in.or more @ stairs,decks,patios
Guard at stairwell at 34 in.or more
Guard at deck,porches 36 in. or more
Exterior Finish Complete
Interior/Exterior Railings 34 in. to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Grade away from foundation 6 in.with 10 ft. -���
Handrail Termination at Newell Post or Wall
8 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft. or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed
Interiorprivacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazjqg
Window in stairwell afety glazing
Interior Smoke Det etors:
Every level: 1 very Broom:
Outside every bedroom ea:
Inter Connected: / Battery backup.
Bathroom'Fans,if no window
Carbon Monoxide detector
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
%hour fire door/door closer
Garage fireproofing
Duct work Sealed properly
Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, 1 s . ft.-150 s .ft.vents
Buildin No./Address visible from road
Final Electrical .
Site Plan /Variance required
Final Survey Plot Plan
As Built Septic System/ wer Dept.Ins ection Sticke
Flood Plain Certification,i require
Okay to issue C/C(Cert.Of Compliance)
Okay to issue Temporary C/O(Cert. Of Occu anc
'Okay to issue Permanent C/O Cert. Of Occupancy)
L:\SueHenurigway\Building.Codes.Inspection.FORMS\Iles.Final Insp.form 2.doe edited January 28,2003
Rough Plumbing Insulation Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Pepart:t't am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT#:
LOCATION: Er fi INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2,R-3,R-4 Drain Vents
Cast Iron,Copper Drain/Vent Comm.
Plumbing Vent Vents in Place
Rough Plumbing/Nail Plates
Head or Air Supply Test
Drain and Vents
5 PSI or 10 ft. above highest
Connection for 15 minutes
Water Supply Piping
pper Commercial
Co
Copper,CPVC,Pex One &Two Family
**Insulation/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct Work Sealed Properly
COMMENTS:
.L:\SucHeming%vay`Building.Codes.Inspecdon*.FORMS\Rough Plumbing Insulation Report.doc January 28,2003
Framing /Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: iFlm/pm .
742 Bay Road, Queensbury,NY 112804 Inspector's Initials:
NAME: PERMIT#:
LOCATION: INSPECT ON: zleeMA
TYPE OF STRUCTURE:
Y N NIA 'COMMENTS
Framing
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
I V2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft, floor trusses
Anchor Bolts 6 ft.or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2,3 hour
e wall 2, 3,4 hour
Firestopping
Penetration scaled
16 inch insulation in cavity min.
Garage Fire Separation
House side V2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7.sf above/below grade
5.0 sf grade
LASueHerningway\Building.Codes,InspectionTORMSTrarning Firestopping Inspection Report.doo January 28,2003
Rough Plumbing / Insulation Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/ am/pm
742 Bay Road,Queensbury,NY 12804 Inspector's Initials:
NAME:, PERMIT#: L c;2_
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
N N/A
PVC: R-1,R-2,R-3,R-4 Drain Vents
Cast Iron,Copper Drain/Vent Comm.
Plumbiiing Vent/Vents in Place
A,- R-Kg—h Plumbing/Nail Plates
Head or Air Supply Test
Dfain and Vents
5 PSI or 10 ft. above highest
Connection for 15 minutes
Water Supply Piping
Copper Commercial
Copper,CPVC,Pex One&Two Family
Insulation/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct Work Sealed Properly
COMMENTS:
,L:\SueHemingway\Building.Codes.inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003
Foundation Inspection Report
Office No. (518)761-8256 Date Inspection qu i
Queensbury Building&Code Enforcement* Arrive: \-LZ in part: a p
u i
742 Bay Rd., Queensbuiy,NY 12804 Inspector Ts--J�ilifal epart.
NN
NAME: r\r\r. C�Y—6 IT#: 3
LOCATION: rSPECTON:
TYPE OF STRU T
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Danipproofing
Foundation/Waterproofing
Type of Danipproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6qinc.jes above footing
----6 mil of for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L.-\SueHemingway\Building.Codes.Inspectioii.FORMS\Foundation Inspection Reportdoe January 28,2003
Foundation Inspection Report
Office No. (5 IS)761-8256 Date Inspection r'eq st received:
Queensbury Building&Code Enforcement Arrive: . m Depart: am/pm
3
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:
NAME: m l PERMIT#: :;20-0
LOCATION: INSPECT ON: OW-1 4
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in-Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
ooting'Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil of for wet areas Linder slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\SueHemiT)gway\Building,Codes.Inspection.1-ORMS\Foundation Inspection Report.doc January 28,2003
Framing /Firestopping Inspection Report �!
Office No.(518)761-8256 Date Inspection request received.
Queensbury Building&Code Enforcement Arrive: am/pm e art:
742 Bay Road Queensbury,NY 12804 Inspector's Initials: : r
NAME: PERMIT#:
LOCATION: INSPECT ON: — —r
TYPE OF STRUC URE: " n
Y N 'N/A COMMENTS
MEN'TS
.raniingt ='
Jadk Studs!Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 12(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1,2,3 hour
Fire wall 2, 3,_4..hour LJ,
-1 r�estopftg
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:1SueHemingway\Building.Codes.Inspection,FORMS\Framing Firestopping Inspection Report.doc January 28,2003
vV
Framing /Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection reque c d-
I
Queensbury Building&Code Enforcement Arrive: a a
742 Bay Road,Queensbury,NY 1.2804 Inspector's Initia
NAME: uL PERMIT#:
LOCATION: 1 2-< U�crP-ff E INSPECT ON:
TYPE OF STRUCTURE:
Framing Y N N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 3 6 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
I V2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft, floor trusses
Anchor s 6 ft. or less on center
,->Kand snow shield 24 inches from wall
Fire separation1,2,3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side Yz inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7'sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.Codes.Inspection.FORMS\FramingFirestopping Inspection Report.doc January 28,2003
Feundation Inspection Report
Office No. (518)761-8256 Date Inspection r
er ei d:
Queensbury Building&Code Enforcement Arrive: Depart: a pm742 Bay Rd., Queensbury,NY 12804 Inspector's InitiC) 49,
NAME: - T#:
LOCATION: l� CT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in-Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place'
Foun on Dampproofing
aundation/Waterproofing'r—
Type of Dampproofing/ . aterproofing
l
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval ,
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L.\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003
Foundation Inspection Report 7
Office No. (5 L8)761-825 6 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/ Deem
lie
742 Bay Rd., Queensbury,NY 12804 Inspector's In Ftialz �
NAME: AA1C—"1C5fCrV,�Ar--) PERMIT#:
LOCATION: X Xk-X INSPECT ON: J;Zo
TYPE OF STRUCTUI'd,�:
Comments
Y N/A
ootings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is iesponsibleltr'�
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site,
Foundation/Wallpour
Reinforcement in Place
Foundation Darapproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inchwidth
6 inches above footing
6 mil of for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L.\SueHemingway\Building.Codes.Irispection.FORM8\Foundation Inspection Report.doc January 28,2003
Permit Number
REScheck Compliance Certificate Checked By/Date
New York State Energy Conservation Construction Code
RES checkSoftware Version 3.5 Release 1 c
Data filename:F:\SHARE\Design\Energy Calc\WAVERLY PLACE\1 8 Chickory.cck
TITLE;WP 320 Chickory
'TaC1EIV
Up
E j)
COUNTY:Warren jUtq 2003
STATE:New York
HDD:7635 "00 OF
CONSTRUCTION TYPE:Detached I or 2 Family BUILD/N QUEENSBURY
G AND
HEATING TYPE:Non-Electric
DATE: 06/06/03
DATE OF PLANS:June 6,2003
PROJECT INFORMATION:
Waverly Place
Queensbury,NY 12804
COMPANY INFORMATION:
The Michaels Grop
10 Blacksmith Dr.
Malta,NY 12020
NOTES:
Silverline 2900 windows
COMPLIANCE:Passes
Maximum UA=291
Your Home UA=282
3.1%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
1st.Fl.Walls:Wood Frame, 16"o.c. 1457 19.0 0.0 74
Ix.Dining(L):Vinyl Frame,Double Pane with Low-E 30 0.400 12
Family#17:Glass 54 0.350 19
Ix Mbr(L):Vinyl Frame,Double Pane with Low-E 30 0.400 12
ix Bed#2(L):Vinyl Frame,Double Pane with Low-E 30 0.400 12
lx Pwdr(N):Vinyl Frame,Double Pane with Low-E 6 0.400 2
Entry#I A: Solid 30 0.350 11
Brkfst#20:Solid 19 0.240 5
Ix Brkfst(L):Vinyl Frame,Double Pane with Low-E 30 0.400 12
Basement Wall 1: Solid Concrete or Masonry 1159 0.0 11.0 75
Wall height:7.6'
Depth below grade:6.6'
Insulation depth: 6.0'
• 3x Basement windows: Wood Frame,Double Pane with Low-E 12 0.520 6
Ceiling 1:Raised or Energy Truss 1301 30.0 0.0 42
Furnace 1:Forced Hot Air,80 AFUE
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,
specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the
New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and
signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or
specifications are in compliance wi this de.
Builder/Designer Date 4�; a 0'3
REScheck Inspection Checklist
New York State Energy Conservation Construction Code
RESchcckSoftware Version 3.5 Release I
DATE:06/06/03
TITLE:WP 320 Chickory
Bldg.
Dept. 1
Use
Ceilings:
[ ] 1. Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation
Comments:
Insulation must achieve full height over the plate lines of exterior walls.
Above-Grade Walls:
[ ] 1. Ist.Fl.Walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
Basement Walls:
[ ] 1. Basement Wall 1: Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insul,
R-11.0 continuous insulation
Comments:
Exterior insulation must have a rigid,opaque,weather-resistant protective covering that
covers the exposed(above-grade)insulation and extends at least 6 in.below grade.
Windows:
[ ] 1. Ix Dining(L):Vinyl Frame,Double Pane with Low-E,U-factor: 0.400
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
[ ] 2. Ix Mbr(L):Vinyl Frame,Double Pane with Low-E,U-factor:0.400
For windows without Iabeled U-factors,describe features:
#Panes Frame Type Thermal Break?j ]Yes j ]No
E Comments:
[ ] 1 3. Ix Bed#2(L):Vinyl Frame,Double Pane with Low-E,U-factor:0.400
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal.Break?j ]Yes[ ]No
Comments:
[ ] 4. Ix Pwdr(N):Vinyl Frame,Double Pane with Low-E,U-factor: 0.400
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes j ]No
Comments:
[ ] 5. lx Brkfst(L):Vinyl Frame,Double Pane with Low-E,U-factor:0.400
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? [ ]Yes[ ]No
Comments:
[ ] 6. 3x Basement windows:Wood Frame,Double Pane with Low-E,U-factor:0.520
For windows without labeled U-factors,-describe features:
#Panes Frame Type Thermal Break?j ]Yes[ ]No
Comments:
Doors:
[ ] 1. Family#17:Glass,U-factor: 0.350
Comments:
[ ] 2. Entry#IA: Solid,U-factor: 0.350
c
Comments:
[ ] 3. Brkfst#20: Solid,U-factor: 0.240
Comments:
Heating and Cooling Equipment:
[ ] 1. Furnace 1:Forced Hot Air,80 AFUE or higher
Make and Model Number
Air Leakage:
[ j Joints,penetrations,and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly
with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a
3"clearance from insulation.
Vapor Retarder:
[ j Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
[ j Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ j Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ j Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
[ j Supply ducts in unconditioned attics or outside the building must be 'insulated to R-11.
[ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6.
[ ] Supply ducts in unconditioned spaces must be insulated to R 11.
[ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2.
Insulation is not required on return ducts in basements.
Duct Construction:
[ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
(adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in.w.g.(500 Pa).
[ j Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ j Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
Electric Systems:
[ j Separate electric meters are required for each dwelling unit.
Fireplaces:
[ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
provisions of the Building Code of New York State ,the Residential Code of New York State or
the New York City Building Code,as applicable.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate
circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
j Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) up to o III Up to 1.25" 1.511,to 2.011 Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. 'Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 IA 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD (Building Department Use Only)
Project Name: / 41� BP# 3' 2-f
Address:
Building Per-nit Submission SFD
Checklist 2-Family
All items below must be checked either yes,no or not applicable prior to submission of any building
permit to the Town of Queensbury Building Department. If any of the below items are lacking,the permit
will not be accepted until such time as the application is deemed complete for submission.
1. Building Permit Application Completed ... ............................... ... . ❑yes ❑no' ❑n/a
2. EnergyFonn or Chec"te Energy Code Compliance Forms Complete., ❑yes [-]no D n/a
(2 copies)
3. Energy Code Inspector's Report from Checld&te Program... ... ......... .. ❑yes ❑no n n/a
(2 copies)
4. Septic application completely filled out(if applicable)...........
5. Solid Fuel Bunting or Gas Appliance Form... ...... .❑yes ❑ ❑
b. Electrical Inspection Form... ... ... ❑yes [:,] ❑
7. Two(2) complete sets of structural drawings..... ... . ❑yes ❑ ❑o
a) floor plan;b)foundation plan;c)cross sections:d)elevations; j
e)window and door schedule e
8. Two (2)site plans showing location of the structure to be built.......... ... Oyes ❑no '❑n/a
location of well or water lines,location of septic system or sewer line.
R. Setbacks from property lines to new structure... ...... ... ... ............... .. Oyes nno ❑n/a
10. Setbacks to neighboring wells and septic systems,including onsite well.... ❑yes Ono ❑n/a
and septic systems (if applicable)
11. DrivewayPernut... ... ......... ... ... ... ... ... ... ... ... ......................... ... ❑yam ❑ o ❑
n nla
Date:
Staff Initial:
L-\SueHemingway\Bugding.PermitFORMS\Generic Checkhst.doc January 28,2003
l
Check Residential Plan Review: One&Two Family Dwellings
Y/N/N/A ;
(2)Full sets of plans
Over 1,500 sq.ft.—Stamped
Design Loads On Plans: 90 Wind Floor Loads 40 psf
70 Ground Snow Load Sleeping Areas and Attics 30 psf
Calculations:
Window Schedule With Glass Size
Door Schedule/Main Entrance 36"Door
Emergency Escape Or Bedrooms and Habitable Space
Above/Below grade, 5.7 sq. ft.
Grade,5.0 sq.ft.
24"(h)x 20"(w)min.
j 44"Max.Height above floor
,Residential Check Paperwork Compliance and Inspectors Checklist: OK
Dampproofing/Waterproofing Materials On Plans
Foundation Drainage On Plans,if required
6"Drop in 10' Exterior Grade
i
Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where
Re uired
Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls
Platforms At Exterior Doors
(/ Stairway Headroom 6' 8'All Stairs 36"Width
Stair Run and Rise
Winder Run and Rise
Spiral Not Allowed From 2 nd Story
t/ Smoke Detectors Battery Backup and Proper Location
Bathroom Fixtures Proper Clearance
C/'Hall Width,36"min.
Handrails More Than One Riser On.Open Sides
Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"'in Ht.
Safety Glazing Notes For Required Areas
Garage Fire Separation
Garage Floor Sloped
Attic Access
Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access i
Carbon Monoxide Detector Lowest Sleeping Level
Soil Test Results,if required
Septic To Well Or Water Line Separation
All Paperwork Signed
Town of Queensbury'742 Bay Road, Queensbury,NY 12804
Building & Code Enforcement Building Permit
Phone:(518)761-8256 Date:
Fax: (518)745-443-1
Email: rodes@quembury.net
Dear
Your building perandt application has been reviewed and found to be deficient in the following areas:
These details need to be added to or noted on both sets of plans. please feel free to contact this office with anyquestions
regarding this matter.
Sincerely,
BUMDING&CODES OFFICE
L:ISueHeniingwayNBuilldin&fcrrriLFORMS%detcient building permit Jan 2003-410C
ti
a 0
C7 z
U'
O
0 U
a
cd
a
,98'6lL � ti
w
O '
YM M \
O
Rid
�aoZ� luJ�^`7yvt � � €sg 'SIR
1p�
";,..
° O
co to
Q� z
i
t"� rn rn
j!
MAP REFERENCE: j
WAVERLY PLACE SUBDIVISION
DATED AUGUST 24. 2000 1
LAST REVISED JANUARY 19. 2001
BY VAN DU5EN 5TEVE5
LAND SURVEYORS, LLC
r ji
s
J 1
I
I
S8917'53"E
119.86'
0
ex�
3�.h2 01
�
CO. RECEIVED
DEC DEC 0 0 ?nn3 b
I, I 8,202 sq.ft. TOWN OF QUEENSBURY
1 boo t y�00 R�I11_UlNG/iND C011E
wop, 4fR 0.19 acres
1 O P5P PAR i `'
i
w N vev �y
3333600
too, 12o
0 52 Ull
33�5 t 2 S100pr\ 8,194 sq.ft.
w050NNpvSti 0.19 acres
�O
rool
>0000
l
g0 — cfl
`\ A
e
FCC
7�'ee-cr
aIy Du
S Date, M , 2003
�'"1 "UNAUTHORIZED ALTERATION OR ADDITION S A SURVEY Map of a Survey made for Scale 1'=20'
(� •�`�/ MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A
�/�_/`j/,V�- VIOLA TON OF SECTION 7209,SUB-DIVISION 2,OF THE
NEW YORK STATE EDUCATION LAW."
"ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY
A MARKED 1M1}i AN ORIGINAL OF THE LAND SURVEYORS THE
T
S 'iF" e �T e s SEAL SHALL BE CONSIDERED TO BE VALID TRUE COPIES.' 1 H M I C HA E L S GROUP
S�•
St eves "CERTIFICATIONS INDICATED HEREON SIGNIFY THAT ,j,1
THIS SURVEY WAS PREPARED IN ACCORDANCE WITH THE
L a IZ d Surveyors LANDEXISTING CODE OF PRACTICE FOR LAND SURVEYORS ADOPTED
BY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL
LAND SURVEYORS.SAID CERTIFICATIONS SHALL RUN ONLY
TO THE PERSON FOR WHOM THE SURVEY IS PREPARED,AND ��J /��
ON HIS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL ('� SHEET 1 OF 1
AGENCY AND LENDING INSTITUITION LISTED HEREON,AND Town of Queensbury, Warren County, New York
169 Haviland Road Queensbury, New York 12804 TO THE ASSIGNEES OF THE LENDING INSTITUTION." Mlchaels
(518) 792-8474 New York Lic. No. 50135 1 1 1 NO. I DATE DESCRIPTION DWG. NO. 99312-51-52
rt
Rough Plumbing /Insulation Inspection Repo
Office No. (518)761-825 6 Date Ins ectio, r est receive
e�ctio r est receive
Queensbury Building&Code Enforcement Arrive: De a In
742 Bay Road,Queensbuiy,NY 12804 Inspector's Ins
NAME: PERMIT
LOCATION: J2 INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2,R-3,R-4 Drain Vents
Cast Iron,Copper Drain/Vent Comm.
Plumb' g' Vent Vents in Place
5
AZo-ugh Plumbing/Nail Plates
Head or Air-Supply Test
Dfain and Vents
5 PSI or 10 ft. above highest
Connection for 15 minutes
Water Supply Piping
Copper Commercial
Copper, CPVC,Pex One&Two Family
In ulation/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct Work Sealed Properly
COMMENTS:
•L.\Suel4emingway\Building.Codes.Inspection,FORMS\Rough Plumbing Insulation Report.doc January 28,2003