Loading...
2003-411 MAP REFERENCE: MAP OF A SUBDIVISION MADE FOR MICHAEL CANTIELLO DATED AUGUST 24, 2002 LAST REVISED OCTOBER 10, 2002 BY VAN DUSEN & STEVES LAND SURVEYORS, LLC LOT 6 / / LOT 5 \ 1.00 ACRES s O c;--00,3 0 �. O 177.75' ti� ti00,�,O \ RECEIVE S41'25'43"W D I \ DEC 10 2003 \ TOWN OF QUEENSBURY I \ BUILDING AND QpDE I 3 � } co LO co \ U \Z IPF 150.03' 75.62' o T— S41'34'48"W S42'13'29"W LOT 4 LOT 3 1 HEREBY CERTIFY THAT THIS MAP WAS PREPARED FROM AN ACTUAL FIELD SURVEY. THIS CERTIFICATION SHALL RUN ONLY TO THE PERSONS FOR WHOM THE SURVEY WAS PREPARED. AND ON THEIR BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON. CERTIFICATIONS ARE NOT TRANSFERABLE TO ADDITIONAL INSTITUTIONS OR SUBSEQUENT OWNERS. CERTIFIED TO: SANDRA L TURPIN BANKNORTH N.A., IT'S sUCCE AND/OR ASSIGNS CHICAGO CE COMPANY L ri CERT1 MA NYS 50135 DATED: SEPTEMBERDu O ` * � a eI , "UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY Map Of 8 Survey made for , , ('"� YAP BEARING A LICENSED LAND SURVEYORS SEAL IS A Scale 1 =40 \���(\/vim_ VIOLATION OF SECTION Tsar,sue-aNsaN s,of THE NEW YORK STATE EDUCATION LAW.' *ONLY COPIES FROM THE ORKUNAL OF THIS SURVEY MARKED WITH AN ORIGINAL OF THE LAND SURVEYORS Steves "C SHALL T CONSIDERED TO BE VALID TRUE COPIES' Sandra L. Tur p in S- 1 'CERTIFICATIONS INDICATED HEREON SIGNIFY THAT INS SURVEY WAS PREPARED IN ACCORDANCE WIN THE Land S L1 Y'V e y o r S LANDS SURVEYORS. S.PRACTICE FOR LAW SURVEYORS ADOPTED GY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS.SAID CERTIFICAl10NS SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED.AND ON WS KNA1F TO THE TITLE COMPANY,OOVERNMENTAL SHEET OF 1 169 Haviland Road Queensbur , New York 12804 TO AND LENDRLG INSTITUTION LINON LISTED HEREON oT� y THE ASSIGNE OFES THE EiVMID INSTITUTION.' Town of Queensbury, Warren County, New York TURPIN C-985 518 792-8474 New York Lie. No. 50135 NO. DATE DESCRIPTION DWG. No. 02154-4 59-4-4 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804.5902 (518)761-8201 . Community Development-Building&Codes (518)761.8256 CERTIFICATEOFOCCUPANCY Permit Number: P20030411 Date Issued: Friday,December,12,2003 This is to certify thatvork requested,to-be done as shown by Permit Number.. P-20030411 has been completed, Tax Map Number: 523400-297-014-0001-003-003-0000 Location: 260 CRONIN Rd Owner: HAYES CONSTRUCTION GROUP,LLC Applicant: HAA.YES CONSTRUCTION GROUP,LLC This structure may be occupied as a: By Order of Town Board Garage-2 Cars Attached TOWN of QUEENSBURY Single Family Dwelling Director of Building O.de E rcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY U804-5902 (518)7G1-8201 Community Development-Building&.Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20030411 Application Number: A20030411 Tax Map No: 523400-297-014-0001-003-003-0000 Permission is hereby granted to: HAYES CONSTRUCTION GROUP,LLC For property located at: RIDGE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and-in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: HAYES CONSTRUCTION GROUP,. Garage-2 Cars Attached Rd Single Family Dwelling $150,060.00 P.O; BOX 109 Total Value GLENS FALLS;NY 12801-0000 $iso,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency HAYES CONSTRUCTION GROUP,LLC 395 BIG BAY Rd QUEENSBURY,NY 12804-0000 Plans&Specifications 2003-411 LOT 5 HSE#260 CRONIN ROAD 1902 SQ FT SINGLE FAMILY DWELLING WITH 2-CAR ATTACHED GARAGE AS PER PLOT PLAN SPECIFICATIONS $279.94 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,June 24,2004 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the rmfl s June 24,2003 SIGNED BY IAfor the Town of Queensbury. Director of Building&Code Enforcement Building Permit Applicationi Town of Queensbury Department of Community Development,742 Day Rd.,Queensbury,NY 12804 (518)761-825-6 A permit must be obtained before beginning construction. ParmitNo.: No inspection will be made until applicant has received a Fee Paid: valid building permit. Form must be completed. Rec.Fee Paid: ve D Reviewed By: JUN 12003. Applicant: Owner: /74q 11 -O �ENSBQRY 714ey 12 QOQe Address: Address: Phone Ph'DVe;ff: • Tax Map Number: 3 .2 Subdivision Name: d(�7 1-4-2�r (if applicable) 2 2003 Lot Number: House Number:;2601 Street Name OR "-Jvv'V OF QUE - RQk�� ENSBURY Property Location: 6'- 1 Z ND-C-0-6c �New Building: Reside ' /Commercial Estimated Market Value of Construction: Z62, &40 , u Addition: Residential/Commercial If an Addition,what will use of addition be? u Alteration: Residential/Commercial o No change to Exterior size: Residential/Commercial u Other work: (describe Check Below Occupancy Info Vfloor sq.ft. 21d floor sq.ft.. Other floor sq.ft. Total Sq.Ft. Single Family Dwelling '109 Two Family Dwelling Townhouse Multifamily Dwelling #of units Office Mercantile Manufacturing I car detached garage car detached garage r 3 car detached garage -1 car attached garage 2 car attached garage 3 car attached garage Storage Bldg.,Comm. Storage Bldg.,Res. Other What is the proposed height of the structure: feet inches Will any second-hand or ungraded lumber be used? If so,for wtat? No.of Fireplaces to be installed: 0 No.of Woodstoves to be installed* a List below the person(s)responsible for supervision of work in regards to Building Codes: Name Address -Phone No. Builder n,c4k& Xlrvej Plumber U -7 c/-? Mason ,1 -7 V Electrician 4g., �'-3 airs Declaration: Please sign below after you have carefully read the statement' To the best of my knowledge the statements, contained in this application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual location of all new construction. Signature: (circle one: owner's agent,architect.contractor) f_ Application for Permit=Septic Disposal System C--, Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 1. OWNER INFORMATION: .................................................. Location of installation: �il� ���'ke 12J C%/�� ice Use VF- Lj ' File Permit No. Tax Map No. J U ` �^ ` Fee Paid 2D�3 Owner's Name: /� ��J C �'t S ?- ��✓/J �C C T}OytVV . n�AYl7 p�( �ltl®CODE .......... ' �--� i........................................OU LUr � "....................... Address: 2. INSTALLER'S NAME ICJ d ! PHONE NO. 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gal/bdrm = 1980— 1991 x 130 gal/bdrm = x 110 gal/bdrm = Garbage Grinder Installed yes_ / no Spa or Hot Tub Installed yes 1 no 4. PARCEL INFORMATION: (circle applicable information&indicate measurements) a-phy SoiLNature Ground Water Bedrock or Im ervious Material Dom ater Su 1 Flat sand ;hat depth at depth munici al oiling a Meet feet well Steep slope clay if well; water supply slope other from any septic-system depth: absorption is ft. other Percolatiol Test: (To be completed by licensed professional engineer or architect) Rate:Z�a-�-L minute per inch 5. PROPOSED SYSTEM: For New Construction:, All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder, Spa or Whirlpool Tub. Septic Tank: j gallon(min. size 1,000 gal) Tile Field: each trench ft. Total System Length: ""�-/ ft. Seepage Pit(s): number of size of each: ft. by ft. Size of Stone to be used: # / depth or thickness feet Bed System Size: Z c J x '� Alternative System: i length and/or size 6. HOLDING TANK SYSTEM: (if requir Number of tanks: / Size of eac gallons /TOTAL Capacity: gallons Note: Alarm System and associated ele 'cal work must be inspected by a Town approved electrical inspection agency. '7. SIGNATURE &INFORMATION OR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. Signature of responsible person Da t e ` r�OLVit.•t)r �Zlit2t'ilaY)tIt'�7 '" ' S(-%Vc:i•:4 :)ficl L+usi>>,c;_.I;)i:,Ims—t1 t.11:111<tt�i• AI)pini .Ix C r _ .:._ , „�' /1•l�.�t)IL�''•�'ICI�1. I�'I I1�I) � . . SEIPAitATIt, N s t•Ar,era -�..._ _ .. _-•--•—_. -_. ._ POND V'j�LL. IN t/�T=S'it. ../ � ftt, tt`rt•.= • •tlUpttT Cl�Slrir; _.��A`---• J�•" tSou� G t5£ :_>* tip:>vslr G F Y {+x7"sKniP ilG1 1 ' t�lis•t:.ts ' t—.. ftCA. 7. SIGNAT'URE &INFORMATION F41��:�Ytit���si.�rr�"�.�:a�.d••••••••v r Residential Final Inspection Office No. (518)761-8256 Date Inspection ieq -treceive �CX Queensbury Building&Code Enforcement Arrive: a 742 Bay Rd., Queensbury,NY 1280.4 Inspector's Enit" s- NAME: P 7-063 L-4 I LOCATION: 4�L5 C-12 k-) TE: - 17- TYPE OF STRUCTURE: I zf 3P Comments --Y . N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete 14 -Guard 30 in.or more@ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more I Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30A or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-*off boiler Relief Valve(s)installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety.... azing Window in stairwells safety glazing Interior Smoke Deoctors: Every level: Every 13 dro,041' Outside every bedro area: / Inter Connected: j / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf V Emergency eEess below grade Basement stairs closed rise>4 inches hour fire door/door closer .Garage fireproofing Duct work Sealed properly Attic access 30 in.x 24-in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq.ft,-150 sq. ft.vents Building No./Address visible from road A/1 Final Electrical ALI Site Plan /Variance required Final Su-rrvq3LPlot Plan It§;;tic- ste Sewer Dept,Inspection Sticker Flood PlainCertification,if required Okay to issue C/C(Cert. Of Compliance) Okay to issue TemporHy C/0(Cert. Of Occupancy) Okay to issue Permanent C/-0(Cert. Of Occupancy) L:\SueHenilfigway\BLitl-d-ing.Codes.Inspectioii.FORMS\Res.Final Insp.form 2.doe edited January 28,2003 Residential Final Inspection 1 Ofie l�io. (518)761=8256 Tate inspection reque ece' d: `r ''--�'�'�~ Queensbury Building&Code Enforcement Arrive: ppepart: m/ m2 742 Bay Rd,, Queensbury,NY 12804 Inspector's InitiaNAME: PLOCATION: TYPE OF STRUCTURE: Comments Y' >N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake Z ZrV 3 inch Plumb Vent through roof Roof Complete Guard 30 in,or more @ stairs,decks,patios Guard at stairwell at 34 in.or more 01 - - ����=�-���� Guard at deck,porches 36 in., or more <2 Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. = - \'A Platform at all.exterior doors Interior Handrails stairs-2 or more risers Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall -- ���-���- ✓ - 1 8 inch clearance to sill plate Gas Valve shut-off ex osed/regulator 18"above grade P V-12 \zp, Gas Furnace shut-off within 30,ft. or within line of site Oil Furnace shut-off at entrance to furnace-area Furriace/Hot Water Heater operating -Low water shut'-off boiler C Relief Valve(s)installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safqty glazing " Interior Smoke Det ctors: Every level: V Every Bedroom: Outside every bedroo area- Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft qop2ing finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches 3K hour fire door I door closer Gara e fireproofing Duct work Sealed properly Attic access 30 in.x 24 1 accessible area Crawl Spaces 18"x 24"access, 1 s ,ft:-150 s . ft.vents —Building No./Address visible from road Final Electrical. Site Plan /-Variance required Final Surve .Plot Plan As Built Se tic s en Y Sewer Dept.Inspection Sticker Flood Plain Certification,if required Okay to issue C/C Cert.Of Compliance) Okay to issue Temporary C/Q(Cert.Of Occit ancYH Okay to issue Permanent C/O(Cert, Of Occu anc L:\SueHeming�vay\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003 Residential Final Inspection lI -8256 Date Inspection reque eive Office No. (518) 761 Queensbury Building&Code Enforcement Arrive: al P_ e rt: `;';VD a p 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial P �T NAME: ik IT#: ATE: I 1A In LOCATION: ATE: TYPE OF STRUCTURE: COM WAN Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 iii.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors at Interior Handrails stairs 2 or more risers V, vzoo- Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate TQ)t�A) 6::� Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30.ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed Interior privacy/ entrance 36 in. XA- BathroomMi-tchen watertight Safet laiEg-- [� vA v Zo Window in stairwells afety glazing 9 Interior Smoke Det ctors: ' Every f.t , cry Btoom: Outside every bedroom rea., Inter Connected: ),M/rea,/ Batter ybackup: Bathroom Fans,if no window , Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches 3/4hour fire door/door closer Garage fire proofing Duct work Scaled properly Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, I sg, ft.-150 sq. ft,vents Building No./Address visible from road Final Electrical V Site Plan [Variance required In S 59-42941.1 As Built Septic Sy stem 2>ewer Dept.Inspection Sticker V 0o am ft0lFafi-o-Tf,if required Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C 0(Cert.Of Occupancy) Okay to issue Permanent C 0(Cert.Of Occup ncy) _kI L:\SileHen-ifigway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doe edited January 28,2003 �tio � o .. 5° y co 3OLse taco WR o-eac HOUSE: T mn cLEVAHm r MML 4o $ 64�' ILL sss ; CRONIN ROAD 260 CRONIN ROAD QUEENSBURY ' NY 12804 HAYES"CONSTRUCTION GROUP THE INTENT OF,THIS DOCUMENT IS TO PROVIDE 39SB/G BAYROAD THE BUILDING DEPARTMENT,WITH, THE APPROXIMATE. LOCATION OF SEPTIC SYSTEM COMPONENTS FOR OUEEIVSBURY, IVY 12804 THE ADDRESS INDICATED A80VE IN ACCORDANCE WITH LOCAL BUILDING CODE REQUIREMENTS. i � G z Y I Yf a a u c a o xzoo „ wwa�� o Ew ]W4z �> ,y =4 H OH Ea H OA u 0W H 0 pUNah AWi SvW 0 N ►/1 � j y WWW trr_'„!�Y -�0 0� 0 " W z a a W A H H w a H 0 Sx a U + C A N W H p 9W N W w 0 z W 4 ] W a m x N 0 H O F a W �► H W 4 N a 0 w a 0 w x a z 0 x z0` ] u z w x �+ ] N o a W ' $ H H U H a 4 4 a 0 Q NH w W w r� a 9 W 0 A U 4 U w H U (�r H H Vl x H U Y C �J i I� W H U y z z W H z w u '� W a � � V w H L� E+ w W p; x t� a A A A C�+ > w w W, N z M > k 0 1 z cn u, W H w W w w U I A a cn 0 x Q' 0 Z H a a H a a a W z C c� > H 0 Z 0 0 4 W a a a 4 A W .f z o w �H z0 0 0 H00w 000p � H W M H 0 z4 W H Z H Z w W H Q z Q 0 U U U PI J H a z Q H a' H W ! A H w H H H ►� a 0 H W W W W HA H H O JZHrp45 W U W F+ H A A A W �r U p a ow H r� 0 �i 4 0 W Lei H �i H H 9 zi "z �i z 0 9 �+ 0z x 0 w w a H w w a H HI AzaQHwH Uw Uw , waxxxwcn Septic Inspection Report Office No. (518)761-8256 Date Inspection frest r ei Queensbury Building&Code Enforcement Arrive: lit a D e art: ar�� 742 Bay Rd., Queensbury,NY 12804 Inspector's Initia P NAME: PERMIT NO.: LOCATION: INSPECT ON: RECHECK. Comments and/or diagram Soil Type: Sand Clav T �MUmCip,a4?1t:�Vell Water yp of Wa�E Waterline sep`ar-a7ro-n—cTi`stance ft. ion�ondistance ft. t — (bther-wells: ft. Absorp ion ie : Total length Lx�-�\ �QZ Length of each trench Depth of trenches ft. Size of Stone -Seepage Pits: Number Size: X Stone Size: Pi in Size Type Building to tank %% Tank to Distribution Box Distribution Box t eld I Pit I Opening Sealed: artial Location/Separations Foundation to tank Foundation to absorption ft. Separation of Pits ft.z Conforms as per Plot Plan Location of System on Property: ron n ear Lel Si Right Side Middle r__, iddle Front Middle Rear System Use Status: p proved i2pprtialApproved and nee o be re-inspected,please call the'Building&Codes Office I oved LASueflerni wa g. L:\Suellemi n Inspection Report.doc January 28,2003 Foundation Inspection Report Office No.(5 18)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: anVi)nf Depart: mr /nm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:096-�� 1 f NAME: PERMIT#: 0 3 q V ) LOCATION: (ZA INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A �Po i gs Pi lithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Danipproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Suelien-iingivay\Building,Codes.Inspection.FORMS\Foundation Inspection ReporLdoc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection request ecei Queensbury Building&Code Enforcement Arrive: t: jr)!.Wb am/pm 742 Bay Road,Queensbuly,NY 12804 Inspector's Initial NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: r- -ve'd e al PERMIT#.. Y N N/A PVC: R-1,R-2,R-3,R-4 Drain Vents Cast Iron,Copper Drain/Vent Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents -72 C) 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper,CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly CONEVENTS: -L.\SueHemingway\Building.Codes.Tnspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection requ ecei Queensbury Building&Code Enforcement Arrive: a e 742 Bay Road, Queensbury,NY 12804 Inspector's Initia 0,� NAME: PERMIT#-. —F 41 LOCATION: INSPECT ON: Cj F1 1-1 10(Zx I I�Ip 1�n�Im TYPE OF STRUCTURE. Y N N/A PVC: R-1,R-2,R-3, R-4 Drain Vents Cast Iron,Copper Drain/Vent 1 Comm. Plumbing Vent Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Diain and Vents 5 PSI or 10 ft.above highest Connection for 15 minutes Water Supply Piping Copper Commercial t x opper,CPVC,Pex One&Two Family �Asulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly C01MMENTS: �L-\SueHemingwa)`Building.Codes.Inspectioti.FORMS\Rough Plumbing Insulation Report.doe January 28,2003 Framing /Firestopping Inspection Report Office No. (518)761-8256 Date Inspection requ rec i d: Queensbury Building&Code Enforcement Arrive: - a e art: 742 Bay Road,Queensbury,NY 12804 Inspector's Initial NAME: 661 PERMIT 4: W03-ull. = LOCATION: C11(Z-CNN3 p R-t� 9� INSPECT ON: 2 TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft, floor trusses Anchor Bolts 6 ft. or less on center Ice and.snow shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Y2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASucHerningway\Bui1ding.Codcs.InspectionTORMSTrarning Firestopping Inspection Report.doe January 28,2003 Rough Plumbing // Insulation InSpec tion e g Office No. (518)761-8256 Date Inspection re receiv Queensbury Building&Code Enforcement Arrive: pm D t: %2. aVp 742 Bay Road,Queensbury,NY 12804 Inspector's Ini ' 1 NAME: _ PERMIT#: "1 6 1 LOCATION: `` INSPECT ON: TYPE OF STRUCTURE: �'7 y� PVC: R-1,R-2,R-3,R-4 Drain/Vents N NIA Cast Iron,Copper Drain/Vent/Comm. Plumbi Vent/Vents in Place ugh Plumbing/Nail Plates Head or Air Supply Test Cp Drain and Vents �ICC�, �o�-- _,�� 5 PSI or 10 ft. above highest Connection for 15 minutes _ Water Supply Piping % �• Copper Commercial o per, PVC,Pex One&Two Family Ins ential Cheek/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: L:\SueHemingway\Building.Codes.Inspection,FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No.(518) 761-8256 Date Inspection re es ei Queensbury Building&Code Enforcement Arrive: pa a m 742 Bay Road,Queensbury,NY 1.2804 Inspector's Initi s: NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE— Y N/ N/A COMMENTS naming Jack Stiids/Headers Bracing/Bridging Joist hangers V Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in, Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall.2*, 3,4 hour Firestopping Penetration scaled 16 inch insulation in cavity min. Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above below grade 5.0 sf grade L:\SueHemingway\Building,Codes,lnspection.FORMS\FramingFirestopping Inspection Report.doo January 28,2003 Framing / Firestopping Inspection Report Office No.(518)761-8256 Date Inspection reque ceive Queensbury Building&Code Enforcement Arrive: f a e ``���a In 742 Bay Road,Queensbury,-NY 12804 Inspector's Initi NAME: PERMIT#: LOCATION: INSPECT ON: 1 1 TYPE OF STRU U E: Y N N/A COMMENTS � raining Jack Studs/Headers racin Bridging !� ' w\ - g6E5 i Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Z�Q Notches/Holes/Bearing Walls '-2 Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D.nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center i� C- Ice and snow shield 24 inches from Yall Fire separation 1, 2,3 hour l Fire wall. = 3,4 hour Firestopping 'rG Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side ''/2 inch or 5/8 inch T e X Garage side 5/8 inch Type X ' k>V��.-� Ceiling/wall VIC- VA\C ejD f 9-- Windows Habitable Space/.Bedroom 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade \AA ��- -- LASueHemingway\Building.Codes.Inspection.FORMSTraming Firestopping Inspection Report.doe January 28,2003 Q � �v��i��M r✓�1�p� � Framing /Firestopping Inspection Report Office No. (518) 761-8256 Date Inspectioprequ cei r Queensbury Building&Code Enforcement Arrive:7�,�b -a In aj 742 Bay Road, Queensbury,NY 112804 Inspector's Initia Z.�C>75 NAME: PERMIT#: LOCATION: INSPECT ON: —16 TYPE OF STRUCTU : Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 3 6 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft, floor trusses C7 A hor Bolts 6 ft. or less on center Ice and snow shield 24 ' homes %m%I Mcr- Qz- Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min, Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes,lnspection.FORMS\FramingFirestopping Inspection Report.doc January 28,2003 Framing /Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection reques ceive Queensbury Building&Code Enforcement Arrive: amt in D a J in 742 Bay Road,Queensbury,NY 12804 Inspector's Initial NAME: PERMIT# LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS raming Jack Studs/Headers Bracing/Bridging Joist hangers ,lack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft..8 in. Notches/Holes/Bearing Walls ' 4 Metal Strapping for Notches Top Plate f 1 %2,(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anch r Bolts 6 ft. or less on center I an ow shield 241 ches from wall Fire separation T,2,3 ho r-- Fire wall 2, 3, 4 hour. Firestopping v Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation _ House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space!Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.inspection.FORMS\Framing Firestopping inspection Report.doc January 28,2003 .1 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Daie Inspection reques ived: Queensbury Building&Code Enforcement Arrive:j s`l5"` a m e Vj am1 742 Bay Road, Queensbury, NY 12804 Inspector's Initial . I--,- NAME: `� l� (' yam- s PERMIT#: 411 LOCATION: (- 01 0 QL� 0 INSPECT ON: TYPE OF STRUCTURE: h Framing Y N NIA COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls p � Metal Strapping for Notches Top Plate _ 1 %2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center 11Y Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall 2, 3, 4 hour Firestopping / f Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L;\SueHemin-.way\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 ntJL VC'Y Foundation Inspection Report Office No.(51,8)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: aTt � Depart�' -a�i/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Irtitial NAME: PERMIT#: f LOCATION: CkZUUj1 -� INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour ,Xenforcement in Place V/ Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil of for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASuellenringway\Buildin g.Codes,Inspection.FORMS\Foundation Inspection Report doc January 28,2003 Foundation Inspection Report Office No..(5 18)761-8256 Date Inspection request received: '7 0 Queensbury Building&Code Enforcement Depart Arrive: am/pin .Z lnlpm j ' 742 Bay Rd., Queensbury,NY 12804 In.spector's Initials:, ' 14e I�Aa NAME: PERMIT#: cPe/b 3-,tf-h LOCATION: INSPECT ON: -7 1,Yl 0 TYPE OF STRU JR Comments Y N N/A Footings/ Piers Monolithic Slab Reinforcement in-Place The contractor is iespEiblAor V1 providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place • Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil of for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Glade 6 inch-drop within 10 ft. L:\SueHemingway\Building.Codes,lnspection.FORMS\Foundation Inspection Report.doc January 28,2003 Permit Number MECcheck Compliance Report Checked By/Date Proposed New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release lb Data filename:C:\MECcheckUHAYES RIDGE#l.cck TITLE:HAYES GROUP JUN 12 2003 COUNTY;Warren Tol'VJ 0FBUILDIN 4iV SBURY STATE:New York 0 COS HDD:7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE:06/09/03 DATE OF PLANS:05-09-03 PROJECT INFORMATION: HAYES GROUP RIDGE ROAD W/BONUS ROOM COMPANY INFORMATION: HAYES GROUP COMPLIANCE:Passes Maximum UA=518 Your Home=427 17.6%Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling l:Flat Ceiling or Scissor Truss 951 38.0 0.0 29 Ceiling 2:Cathedral Ceiling{no attic} 120 30.0 - 0.0 4 Wall 1:Wood Frame, 16"o.c. 1487 19.0 0.0 64 Window 1:Vinyl Frame,Double Pane 276 0.490 135 Door 1: Solid 20 0.069 1 Door 2: Solid 18 0.069 1 Door 4: Solid 30 0.069 2 Door 3: Glass 80 0.490 39 Wall 2:Wood Frame, 16"o.c. 1269 19.0. 0.0 76 Basement Wall 1: Solid Concrete or Masonry,8.0'ht/7.0'bg/8.0'insul 884 11.0 0.0 56 Basement Wall 2:Wood Frame, 8.0'ht/7.0'bg/8.0'insul 160 19.0 0.0 8 Floor 1:Ail-Wood Joist/Truss,Over Unconditioned Space 309 30.0 0.0 10 Floor 2:Ali-Wood Joist/Truss,Over Outside Air 63 30.0 0.0 2 Furnace l:Forced Hot Air,92 AFUE' COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building Table T- Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts' Temperature(F) U'0 to VI -Up to 1.2511 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Tablet: Minimum Insulation Thicknessfor HVACPipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts 1"and Less 1.25"to2l'12.5"to4l'Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 '1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 - 0.5 0.5 0.35 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only) Y - plans,specifications,and other calculations submitted with this-permit application. The proposed systems have been designed to meet the ,Proposed New/ York State Ene�Conservation Construction Code requirements. Builder/Designer L-C(J[i d �� O�try+ Date /11/0 OF NEW ��A¢p KEtTty�a 0 ,9'� cc Zo 6 .► ?W F P MECcheek Inspection Checklist Proposed New York State Energy Conservation Construction Code MECcheck-Software Version 3.3 Release lb DATE:06109/03 TITLE:HAYES GROUP Bldg. Dept. Use Ceilings: 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-3 8.0 cavity insulation Comments: ' 2. Ceiling 2: Cathedral Ceiling(no attic),R-30.0 cavity insulation Comments: Above-Grade Walls: 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: 2. Wall 2:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: 1. Basement Wall 1:Solid Concrete or Masonry,8.0'ht/7.0'bg/8.V insul, R-11.0 cavity insulation Comments: 2. Basement Wall 2:Wood Frame,8.0'ht(7.0'bg/8.0'hasul,R-19.0 cavity insulation Comments: Windows: 1. Window 1:Vinyl Frame,Double Pane,U-factor:0.490 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: 1 1. Door 1: Solid,U-factor:0.069 Comments: 2. Door 2:Solid,U-factor:0.069 Comments: 3. Door 4: Solid,U-factor 0.069 Comments: 4. Door 3:Glass,U-factor:0.490 #Panes Frame Type -Thermal Break? Yes I No Comments: Floors: 1. Floor 1:All-Wood Joist/Truss,Over Unconditioned Space,R-30.0 cavity insulation Comments:' 2. Floor 2:All-Wood Joist/Truss,Over Outside Air,R-30.0 cavity,insulation Comments: Heating'and Cooling Equipment: 1. Furnace 1:Forced Hot Air,92 AFUE or higher Make and Model Number frI Air Leakage: Joints,,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be Type IC rated and installed with no penetrations,or Type IC or non-IC rated installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials and 3"clearance from insulation. Vapor Retarder: Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. I Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Supply ducts in unconditioned attics or outside the building must be insulated to R-11. Return ducts in unconditioned attics or outside the building must be insulated to R-6. Supply ducts in unconditioned spaces must be insulated to k-11. Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters are required for each dwelling unit. Fireplaces: Fireplaces must be installed with tight fitting non-combustible fireplace doors. Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of York State,the Residential Code of York State or the New York City Building Code,as applicable. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and-outlet unless the water heater has an integral heat trap or is part of a circulating system. J Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate dirculating hot water pipes to the levels in Table 1. Swimming Pools: [ ] t All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Wiping Insulation: [ ] HVAC piping conveying fluids above 105°F or chilled fluids below 55°F must be insulated to the levels in Table 2. Project Name: C AZ- BP# Address: C�4-o G1'2'0 P)!,. Building Pen-nit Submission SFD Checklist 2-Family All items below must be checked either yes,no or not applicable prior to submission of any building permit to the Town of Queensbury Building Department. If any of the below items are lacking,the permit will not be accepted until such time as the application is deemed'complete for submission. 1. Building Permit Application Completed 2. Energy Form or CheckMate Energy Code Compliance Forms Complete .�❑i'"ems ❑;no ❑n/a (2 copies) 3. Energy Code Inspector's Report from Chec"te Program.. ... ......... .. El yes ❑no Q n/a (2 copies) 4. Septic application completely filled out(if applicable)... ............... ... ... ❑.yes ❑no O n/a 5. Solid Fuel Burning or Gas Appliance Form... ... .. .....�- F yes n/a tJno 6. Electrical Inspection Form... ... ... ... ... ... ... ...... ........................ ......11yes Ono ❑n/a 7. Two(2) complete sets of structural drawings..... ... ... ...... ... ... ...... ... ... ©yes [:]no [—]n/a a) floor plan;b)foundation plan;c)cross sections:d)elevations; e)window and door schedule ,- S. Two,(2)site plans showing location of the structure to be built....... :.. ... '❑yes Ono ❑n/a location of well or water lines,location-of septic system or sewer line. R. Setbacks from property lines to new structure... ...... ... ... ...... ...... ... .. r.0')TS Ono Qn/a, 10. Setbacks to neighboring wells and:septic systems,including onsite well,,... . ,Ryes ❑no. ❑n/a and septic systems (if applicable): 11. Driveway Permit... ... ......... ... ... ...... ... ... ...... .................. ... ... ... yes ❑ o ❑��.� n n/a Date: Staff Initial L:\SueHei ' gway\Bui ding.PerrniEFORMS\Generic ChecklssLdoc January28,2003 �3 Check Residential Plan Review: One&Two Family Dwellings Y/N1N/A 2)Full sets of plans Over 1,500 sq. $.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade, 5.7 sq.ft. Grade,5.0 sq.ft. - 24"(h)x 20"(w)min. "Max.Height above floor esidential Check Paperwork Compliance and Inspectors Checklist: OK ampproofing/Waterproofing Materials On Plans Fo ation Drainage On Plans,if required Drop in 10' Exterior Grade Framing Cross Section For Each Roof Line V e Stopping Every 10' Where Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Iatforms At Exterior Doors tairway Headroom 6' 8' All Stairs 36"Width Stair Run and Rise 5 Winder Run and Rise Spiral Not Allowed From 2`1 Story --Smoke Detectors Battery Backup and Proper Location athroom Fixtures Proper Clearance �ffall Width,36"min. Handrails More Than One Riser On Open Sides ailing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas ,Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results,if required Septic To Well Or Water Line Separation All Paperwork Signed