2004-435 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20040435 Date Issued: Friday, November 19, 2004
This is to certify that work requested to be done as shown by Permit Number P20040435
has been completed.
Tax Map Number: 523400-302-007-0001-012-000-0000
Location: 118 QUAKER Rd
Owner: QUEENSBURY QUAKER, L.L.C.
Applicant: CRAWFORD WINDOW&DOOR
This structure may be occupied as a:
By Order of Town Board
Commercial Alteration TOWN OF QUEENSBURY
Director of Building,&Code Enforcement
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20040435 Application Number: A20040435
Tax Map No: 523400-302-007-0001-012-000-0000
Permission is hereby granted to: C;RAWFORD WINDOW&DOOR
For property located at: 118 QUAKER Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: QUEENSBURY QUAKER, L.L.C.
90 STATE St Suite 141 I Commercial Alteration. $14,500.00
Total Value $14,500.00
ALBANY, NY 12207-0000
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2004-435 CRAWFORD WINDOW&DOOR
2800 SQ FT COMMERCIAL INTERIOR ALTERATION
$336.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, July 13, 2005
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the T Queen ury• u day, July 13,2004
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
Building Permit Application
Town of Queensbury-Dept of Community Development,742 Bay Road,Queensbury,NY
(518)761.8256
A permit must be obtained before beginning construction. Permit File NoVt
No inspection will be made until applicant has received a F@®paid
valid building permit. All applicants' spaces on thus Roo.Fee Paid
application must be completed and must appear on the Reviewed B •
application form.
Applicant: tet- Owner: SQ m c-
Address: Address: qv/7- R S7�-,
SC � 13� 06
Phone#(_) D b ot� Phone#
Property Location: Lot Number:. / / House Number
Subdivision Name: Tax Nip Number:_• 62, 7 --!-
0-0
o New Building: residence /commercial •Estimated Market Value of Construction: S
o Addition: residence! commercial If an Addition,what will use of now addition be?
-q Alteration: residence miner
0 No change to exterior size: rest ence(com'1
o Other work(describe Drab re'6r, )Q—duc. HUAe Ib Work •i) 17 ecj 5l0a.4e/ L164/13 IQam P-
Check OccupancyWormation V Floor 2° Floor Other floor Total
Below sq..ft. sq.ft, sq.ft. Square Feet
t, Single family dwelling
v Two family dwelling
o Townhouse '
c Multifamily dwelling
#of units.
o Office
o Mercantilo
o Maaufacturin
0 1 car detached garage JUN i`0 �-
0 2 car detached garage
o 3 car detached&wage W N OF QUI
0 1 car attached garage
0 2 oar attached garage
0 3 car attached garage
a Storage building-
commercial
o Storage building-
residential '
Other a,0,60 . .
What is the proposed height of the structure a feet 6 inches
Will any second-hand or ungraded lumber be used? If so,for what? b
Type of Heating System: electric/ oil / gas wood !forced hot air/ baseboard!other:
Number of , mnlaces to be installed- C-) " Number of Woodstoves to be installed--
List below the person(s)responsible for supervision of work as regards to building codes:
C)G. ClS C-C) Y 5 7-d S S O
Name Address- Phone Number
Builder E F' u 3 ga.-001,a
Plumber to -- l
Mason v—
Electrician 1 o — I
Declaration: please sign below after you have.carefully read the statement:
To the best of my knowledge the statements contained in this application,together with the plans and specifications
submitted,are a true and complete statement of all proposed work to be done on the described premises and that all
provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied
with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Uwe shall ,
submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning
Administrator or Director of Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual
location of all no cons oa
Signature: owner,owner's agent,architect,contractor
Commercial Final Inspection Report
Office No.: (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: �312244 am/pmn/a Depart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: Caw f e,-.�_ ur; PERMIT#: �/ ✓ 13 J
LOCATION: r DATE: d'
COMMENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" t�
Vestibules For Exit doors>3000 sq. ft.
All Doors 36 in.w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator 18")Above Grade
Floor Bathroom Watertight/Other Floors Oka
Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %doors
> 10%> 1000 s . ft.
3/4 Hour Corridor Doors&Closers
Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 s . ft. Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Si a e/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Si na e
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in.Beyond ��
Active Listening System and Signage Assembly Space
Final Electrical
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if reg.-
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides b riveable Surface 20' wide
Okay To Issue Temp. orQrermanent C
-70
Okay To Issue C/C
Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc
�--
°' Commercial Final Inspection Report r►-�
Office No.: (518) 761-8256 Date Inspection request received: I t l A— 0-
Queensbury Building&Code Enforcement Arrive: 1z,) am/pm Depart: am/pm
742 Bay Road,Queensbury,NY 12804 Inspector's Initials: ;✓
NAME: r: 1, ) ' �•v 14t-�OD PERMIT#: W —q s5
LOCATION: DATE: 11-11,V0Y -,AA,T-'/AAP;4n
C 0 M TVN)
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in.Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 s . ft.
All Doors 36 in.w/Lever Handles/Panic Hardware, if required
Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator 18" Above Grade
Floor Bathroom Watertight/Other Floors Oka
Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hn or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/Z doors
> 10%> 1000 sq. ft.
3/a Hour Corridor Doors&Closers
Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire -
Dampers/Fire Doors
'Ceiling Fire Stopping, 3,000 s . ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Si a e/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Si na e
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36" J //
Handicapped Ram /Handrails Continuous/12 in.Beyond
Active Listening System and Signa e Assembly Space
Final Electrical
Site Plan/Variance re uired
Final Survey,New Structure/Flood Plain certification,if reg.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 20' wide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc
Commercial Final Inspection Report
�vc�o
Office No.: (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: sj � am/pm Depart: am/pm
742 Bay Road,Queensbury,NY 12804 Inspector s Initials:
NAME: q 4 , 4 3,5
W . L04� PERMIT#: 7
LOCATION: DATE:
a
CONEMENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in.Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 s . ft.
All Doors 36 in.w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36(w)x 44" 1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator 18" Above Grade
Floor Bathroom Watertight/Other Floors Oka
Relief Va Heat Trap/Water Temp. 110 Degrees Maximumna�:
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil'Furnace Shut Off at Entrance to Furnace Area
Stoclaoom/Storage/Receiving/Shipping Room(2 hr.), 1 '/2 doors
>10%> 1000 s . ft.
3/4 Hour Corridor Doors&Closers
Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
'Ceiling Fire Stopping, 3,000 s . ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Si a e/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Si na e
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36" / I
Handicapped Ram /Handrails Continuous/12 in.Beyond �gofcr� ors, 1 L
Active Listening System and Signage Assembly Space
Final Electrical s ry q^� r�mP
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if reg. f`
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 20'wide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc
i
t/
Town of Queensbury
Fire Marshal's Office
742 Bay Road
Queensbury, NY 12804
Phone (518) 761-8205 Fax(518) 745-4437
Fire Marshal's Inspection Report
Request SCHEDULE
Received: Permit# ��` (3S INSPECTION ON: `� d��
Name: �rraa-,,I �,^ 3 L) AM PM ANYTIME
Location: b'V Cac V-Vckl
APPROVED
N/A, YES NO COMMENTS
EXIT ACCESS
EXIT ENCLOSURE
EXIT DISCHARGE
MAIN AISLE WIDTH
SECONDARY AISLE WIDTH
EXIT SIGN-NORMAL
EXIT SIGN-BATTERY
EMERGENCY LIGHTING
FIRE EXTINGUISHER HUNG
FIRE EXTINGUISHER y %
INSPECTION (� (���T►��
FIRE EXTINGUISHER HYDRO xl \�
FIRE ALARM SYSTEM
FIRE ALARM -FAN SHUTDOWN
FIRE SPRINKLER SYSTEM
FIRE SUPPRESSION-KITCHEN
FIRE SUPPRESSION-GAS
ISLAND n
HOOD INSTALLATION -
INTERIOR FINISHES
STORAGE
COMPRESSED GAS
CLEARANCE TO SPRINKLERS
CLEARANCE TO ELECTRICAL
ELECTRIC WIRING ENCLOSED
COMBUSTIBLE WASTE
VEHICLE IMPACT PROTECTION
FIRE LANE
F.D.SIGNAGE-UTILITY ROOMS
NO SMOKING SIGNS
MAXIMUM OCCUPANCY SIGN
EMERGENCY EVAC PLAN
l
OK THIS DAT f K FOR CO-' NOT OK
INSPECTED BY
COM DEVICHRISJIWORD/LETTERS2001/FIREMARSHALINS PECTIONREPORT11022001
WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY
,Comrner_cial-Tinal Inspection Report
Office No.: (518)761-8256 Date Inspection request received: MAW
Queensbury Building&Code Enforcement Arrive: ()SHb am/pm Depart: am/pm
742 Bay Road, Quee ury, 1280 Inspector's Initials: U
NAME: _ PERMIT#: mod35
LOCATION: I 1 L DATE:
CONIMENTS:
Y N N
Chimney/"B"Vent/Direct Vent Location /
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish Grade Complete 6"in 10' or Equivalent L-a -
Interior/Exterior Guardrails 42 in.Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks ,
Stair Handrail 34 in.-38 in./Ste Risers 7"/Treads 1111 �T "a ' � 7 (("it
Vestibules For Exit doors>3000 s . ft.
All Doors 36 in.w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. V11
Q� c%r G�irsr,�
Gas Valve Shut-off Exposed&Regulator 18")Above Grade
Floor Bathroom Watertight/Other Floors Okay U k) A,Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum ✓ /(�Cg,� ,�'e` v
Boiler/Furnace Enclosure 1 hr.. or Fire Extinguishing System /C-r ✓
Fresh Air Supply for Occupancy/Ventilation Combustion /
Low Water Shut Off For Boilers ✓�J
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil-Furnace Shut Off at Entrance to Furnace Area
Stoclaoom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors
> 10%> 1000 s .ft.
3/4 Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
'Ceiling Fire Stopping, 3,000 s . ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required IZ
Elevator Operation and Si a e/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets ✓ j // �i��d�. f �a�
Handicapped Bath/Parking Lot Si na e �^�'�` /t'
Public Toilet Room Handicapped Accessible l� C f 1
Handicapped Service Counters, 34 in., Checkout 36" '
Handicapped Ram /Handrails Continuous/12 in.Beyond ✓ ��;'�,��r��� y,,,� L r-e ✓��-'
Active Listening System and Signa e Assembly Space
Final Electrical
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if req. ���„n,,✓ 4:A� '' �ry�L
As-built Septic System La ired or On File hoc,, W,
Building Number or Te ant Addreo on Building or Drivewa f, j f
Water Fountain or Coole l/
Building Access All Sides b 0' /I)•'veable�Snurflla�ee201wide ���� C-- �ee.►e'
Oka To Issue Tem . or P �Rzane O
Okay To Issue C/C 'J^j';h d'Utba) 6�
Last printod 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc S/�4Le
Town of Queensbury
Fire Marshal's Office
742 Bay Road
Queensbury, NY 12804
Phone (518) 761-8205 Fax(518)745-4437
Fire Marshal's Inspection Report
Request n SCHEDULE
Received: o oPermit# �l�a - INSPECTION ON: I�
1 4 ig
ti
n --.L-f
Name: i Q a�L�L�� f�6 M PM ANYTIME
Location: I b Qitr&4t, I d,
APPROVED
N/A YES NO COMMENTS
EXIT ACCESS P' X�
EXIT ENCLOSURE —' 1�9�,Qi� 4,� V(,�y�,1
EXIT DISCHARGE _ l
MAIN AISLE WIDTH W via&SECONDARY AISLE WIDTH
y e
EXIT SIGN-NORMAL
EXIT SIGN-BATTERY ',
EMERGENCY LIGHTING ,9
FIRE EXTINGUISHER HUNG
FIRE EXTINGUISHER �
INSPECTION I
FIRE EXTINGUISHER HYDRO
FIRE ALARM SYSTEM �nQ AX15 E Q 6
FIRE ALARM -FAN SHUTDOWN P `�I� 7 l,�
FIRE SPRINKLER SYSTEM
FIRE SUPPRESSION-KITCHEN Aall
,, np F4 FIRE SUPPRESSION-GAS J� 1f(,�1, I
ISLAND
HOOD INSTALLATION ��
INTERIOR FINISHES t
STORAGE
COMPRESSED GAS
CLEARANCE TO SPRINKLERS
CLEARANCE TO ELECTRICAL
ELECTRIC WIRING ENCLOSED
COMBUSTIBLE WASTE
VEHICLE IMPACT PROTECTION
FIRE LANE
F.D.SIGNAGE—UTILITY ROOMS x
NO SMOKING SIGNS
MAXIMUM OCCUPANCY SIGN
EMERGENCY EVAC PLAN
i
OK THIS DfiTE OK FO O NOT OK
1
NSPECTED Y
COM DEVICHRISJIWORDILETTERS2001/F IREMARSHALI NS PECTIONREPORT11022001
WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request receiv
Queensbury Building&Code Enforcement Arrive: a p pa Z% am/
742 Bay Road, Queensbury,NY 12804 Inspector's Initi
NAME: � S�YCJ 1 1 /PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTU :
Y N N/A COMMENTS
\,, raming
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LASueHemingway\BuiIding.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003