Loading...
2004-435 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20040435 Date Issued: Friday, November 19, 2004 This is to certify that work requested to be done as shown by Permit Number P20040435 has been completed. Tax Map Number: 523400-302-007-0001-012-000-0000 Location: 118 QUAKER Rd Owner: QUEENSBURY QUAKER, L.L.C. Applicant: CRAWFORD WINDOW&DOOR This structure may be occupied as a: By Order of Town Board Commercial Alteration TOWN OF QUEENSBURY Director of Building,&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040435 Application Number: A20040435 Tax Map No: 523400-302-007-0001-012-000-0000 Permission is hereby granted to: C;RAWFORD WINDOW&DOOR For property located at: 118 QUAKER Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: QUEENSBURY QUAKER, L.L.C. 90 STATE St Suite 141 I Commercial Alteration. $14,500.00 Total Value $14,500.00 ALBANY, NY 12207-0000 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2004-435 CRAWFORD WINDOW&DOOR 2800 SQ FT COMMERCIAL INTERIOR ALTERATION $336.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, July 13, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T Queen ury• u day, July 13,2004 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Building Permit Application Town of Queensbury-Dept of Community Development,742 Bay Road,Queensbury,NY (518)761.8256 A permit must be obtained before beginning construction. Permit File NoVt No inspection will be made until applicant has received a F@®paid valid building permit. All applicants' spaces on thus Roo.Fee Paid application must be completed and must appear on the Reviewed B • application form. Applicant: tet- Owner: SQ m c- Address: Address: qv/7- R S7�-, SC � 13� 06 Phone#(_) D b ot� Phone# Property Location: Lot Number:. / / House Number Subdivision Name: Tax Nip Number:_• 62, 7 --!- 0-0 o New Building: residence /commercial •Estimated Market Value of Construction: S o Addition: residence! commercial If an Addition,what will use of now addition be? -q Alteration: residence miner 0 No change to exterior size: rest ence(com'1 o Other work(describe Drab re'6r, )Q—duc. HUAe Ib Work •i) 17 ecj 5l0a.4e/ L164/13 IQam P- Check OccupancyWormation V Floor 2° Floor Other floor Total Below sq..ft. sq.ft, sq.ft. Square Feet t, Single family dwelling v Two family dwelling o Townhouse ' c Multifamily dwelling #of units. o Office o Mercantilo o Maaufacturin 0 1 car detached garage JUN i`0 �- 0 2 car detached garage o 3 car detached&wage W N OF QUI 0 1 car attached garage 0 2 oar attached garage 0 3 car attached garage a Storage building- commercial o Storage building- residential ' Other a,0,60 . . What is the proposed height of the structure a feet 6 inches Will any second-hand or ungraded lumber be used? If so,for what? b Type of Heating System: electric/ oil / gas wood !forced hot air/ baseboard!other: Number of , mnlaces to be installed- C-) " Number of Woodstoves to be installed-- List below the person(s)responsible for supervision of work as regards to building codes: C)G. ClS C-C) Y 5 7-d S S O Name Address- Phone Number Builder E F' u 3 ga.-001,a Plumber to -- l Mason v— Electrician 1 o — I Declaration: please sign below after you have.carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Uwe shall , submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual location of all no cons oa Signature: owner,owner's agent,architect,contractor Commercial Final Inspection Report Office No.: (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: �312244 am/pmn/a Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: Caw f e,-.�_ ur; PERMIT#: �/ ✓ 13 J LOCATION: r DATE: d' COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" t� Vestibules For Exit doors>3000 sq. ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18")Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %doors > 10%> 1000 s . ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 s . ft. Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond �� Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if reg.- As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides b riveable Surface 20' wide Okay To Issue Temp. orQrermanent C -70 Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc �-- °' Commercial Final Inspection Report r►-� Office No.: (518) 761-8256 Date Inspection request received: I t l A— 0- Queensbury Building&Code Enforcement Arrive: 1z,) am/pm Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: ;✓ NAME: r: 1, ) ' �•v 14t-�OD PERMIT#: W —q s5 LOCATION: DATE: 11-11,V0Y -,AA,T-'/AAP;4n C 0 M TVN) Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in.Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s . ft. All Doors 36 in.w/Lever Handles/Panic Hardware, if required Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18" Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hn or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/Z doors > 10%> 1000 sq. ft. 3/a Hour Corridor Doors&Closers Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire - Dampers/Fire Doors 'Ceiling Fire Stopping, 3,000 s . ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" J // Handicapped Ram /Handrails Continuous/12 in.Beyond Active Listening System and Signa e Assembly Space Final Electrical Site Plan/Variance re uired Final Survey,New Structure/Flood Plain certification,if reg. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20' wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc Commercial Final Inspection Report �vc�o Office No.: (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: sj � am/pm Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector s Initials: NAME: q 4 , 4 3,5 W . L04� PERMIT#: 7 LOCATION: DATE: a CONEMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in.Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s . ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44" 1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18" Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Va Heat Trap/Water Temp. 110 Degrees Maximumna�: Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil'Furnace Shut Off at Entrance to Furnace Area Stoclaoom/Storage/Receiving/Shipping Room(2 hr.), 1 '/2 doors >10%> 1000 s . ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors 'Ceiling Fire Stopping, 3,000 s . ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" / I Handicapped Ram /Handrails Continuous/12 in.Beyond �gofcr� ors, 1 L Active Listening System and Signage Assembly Space Final Electrical s ry q^� r�mP Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if reg. f` As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20'wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc i t/ Town of Queensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(518) 745-4437 Fire Marshal's Inspection Report Request SCHEDULE Received: Permit# ��` (3S INSPECTION ON: `� d�� Name: �rraa-,,I �,^ 3 L) AM PM ANYTIME Location: b'V Cac V-Vckl APPROVED N/A, YES NO COMMENTS EXIT ACCESS EXIT ENCLOSURE EXIT DISCHARGE MAIN AISLE WIDTH SECONDARY AISLE WIDTH EXIT SIGN-NORMAL EXIT SIGN-BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHER HUNG FIRE EXTINGUISHER y % INSPECTION (� (���T►�� FIRE EXTINGUISHER HYDRO xl \� FIRE ALARM SYSTEM FIRE ALARM -FAN SHUTDOWN FIRE SPRINKLER SYSTEM FIRE SUPPRESSION-KITCHEN FIRE SUPPRESSION-GAS ISLAND n HOOD INSTALLATION - INTERIOR FINISHES STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO ELECTRICAL ELECTRIC WIRING ENCLOSED COMBUSTIBLE WASTE VEHICLE IMPACT PROTECTION FIRE LANE F.D.SIGNAGE-UTILITY ROOMS NO SMOKING SIGNS MAXIMUM OCCUPANCY SIGN EMERGENCY EVAC PLAN l OK THIS DAT f K FOR CO-' NOT OK INSPECTED BY COM DEVICHRISJIWORD/LETTERS2001/FIREMARSHALINS PECTIONREPORT11022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY ,Comrner_cial-Tinal Inspection Report Office No.: (518)761-8256 Date Inspection request received: MAW Queensbury Building&Code Enforcement Arrive: ()SHb am/pm Depart: am/pm 742 Bay Road, Quee ury, 1280 Inspector's Initials: U NAME: _ PERMIT#: mod35 LOCATION: I 1 L DATE: CONIMENTS: Y N N Chimney/"B"Vent/Direct Vent Location / Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent L-a - Interior/Exterior Guardrails 42 in.Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks , Stair Handrail 34 in.-38 in./Ste Risers 7"/Treads 1111 �T "a ' � 7 (("it Vestibules For Exit doors>3000 s . ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. V11 Q� c%r G�irsr,� Gas Valve Shut-off Exposed&Regulator 18")Above Grade Floor Bathroom Watertight/Other Floors Okay U k) A,Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum ✓ /(�Cg,� ,�'e` v Boiler/Furnace Enclosure 1 hr.. or Fire Extinguishing System /C-r ✓ Fresh Air Supply for Occupancy/Ventilation Combustion / Low Water Shut Off For Boilers ✓�J Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil-Furnace Shut Off at Entrance to Furnace Area Stoclaoom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors > 10%> 1000 s .ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors 'Ceiling Fire Stopping, 3,000 s . ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required IZ Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets ✓ j // �i��d�. f �a� Handicapped Bath/Parking Lot Si na e �^�'�` /t' Public Toilet Room Handicapped Accessible l� C f 1 Handicapped Service Counters, 34 in., Checkout 36" ' Handicapped Ram /Handrails Continuous/12 in.Beyond ✓ ��;'�,��r��� y,,,� L r-e ✓��-' Active Listening System and Signa e Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. ���„n,,✓ 4:A� '' �ry�L As-built Septic System La ired or On File hoc,, W, Building Number or Te ant Addreo on Building or Drivewa f, j f Water Fountain or Coole l/ Building Access All Sides b 0' /I)•'veable�Snurflla�ee201wide ���� C-- �ee.►e' Oka To Issue Tem . or P �Rzane O Okay To Issue C/C 'J^j';h d'Utba) 6� Last printod 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc S/�4Le Town of Queensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(518)745-4437 Fire Marshal's Inspection Report Request n SCHEDULE Received: o oPermit# �l�a - INSPECTION ON: I� 1 4 ig ti n --.L-f Name: i Q a�L�L�� f�6 M PM ANYTIME Location: I b Qitr&4t, I d, APPROVED N/A YES NO COMMENTS EXIT ACCESS P' X� EXIT ENCLOSURE —' 1�9�,Qi� 4,� V(,�y�,1 EXIT DISCHARGE _ l MAIN AISLE WIDTH W via&SECONDARY AISLE WIDTH y e EXIT SIGN-NORMAL EXIT SIGN-BATTERY ', EMERGENCY LIGHTING ,9 FIRE EXTINGUISHER HUNG FIRE EXTINGUISHER � INSPECTION I FIRE EXTINGUISHER HYDRO FIRE ALARM SYSTEM �nQ AX15 E Q 6 FIRE ALARM -FAN SHUTDOWN P `�I� 7 l,� FIRE SPRINKLER SYSTEM FIRE SUPPRESSION-KITCHEN Aall ,, np F4 FIRE SUPPRESSION-GAS J� 1f(,�1, I ISLAND HOOD INSTALLATION �� INTERIOR FINISHES t STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO ELECTRICAL ELECTRIC WIRING ENCLOSED COMBUSTIBLE WASTE VEHICLE IMPACT PROTECTION FIRE LANE F.D.SIGNAGE—UTILITY ROOMS x NO SMOKING SIGNS MAXIMUM OCCUPANCY SIGN EMERGENCY EVAC PLAN i OK THIS DfiTE OK FO O NOT OK 1 NSPECTED Y COM DEVICHRISJIWORDILETTERS2001/F IREMARSHALI NS PECTIONREPORT11022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request receiv Queensbury Building&Code Enforcement Arrive: a p pa Z% am/ 742 Bay Road, Queensbury,NY 12804 Inspector's Initi NAME: � S�YCJ 1 1 /PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTU : Y N N/A COMMENTS \,, raming Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\BuiIding.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003