AST-0371-2021 Office Use Only
PRMeWtEtTRUCTURE
PERMIT APPLICATI ON Permit#: S�'- 5`�'1- 2021
Permit Fee:$ '
Town of Queensbury
742 Bay Road,Queensbury, NY 12804 *Rec Fee:$
P: 518-761-8256 www.queensburynet Invoice#: �J
Flood Zone? Y Reviewed By:
Project Location: 24 Russell Harris Road '"5 zv'
Tax Map #: 239.8-1-7 & 60 Subdivision Name: NA
*TOWN BD.RESOLUTION 385-2020:$1000 recreation fee for new dwelling units:single family,duplexes/two-family,
multiplefamily, apartments,condominiums, townhouses,and/or manufactured & modular homes,but not mobile
homes. This is in addition to the permit fee(s).
PROJECT INFORMATION:
X Residential Commercial, Proposed Use:
Single-Family: _Two-Family _Multi-Family(#of units:_)
1. _Custom
2. _Modular(REQUIRED:NYS stamped engineered drawings of foundation plans)
Townhouse —X_Garage (#of cars 2 ) _Business Office
_Retail _Hotel/Motel _Industrial
_Heated Warehouse/Storage Building _Unheated Warehouse/Storage Building
Amusement Ride _Other(describe: )
MAIN STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE:
1ST floor: 672
11 floor:
2nd floor: 273
2nd floor:
3rd floor: Total square feet: 945
Basement(habitable space):
Total square feet:— M CEUVIE
MAY 19 2021
TOWN OF QUEENSBURY
BUILDING P. CODES
Principle Structure Packet Revised January 2021
CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL
• Applicant:
Name(s): Bill &Wendy Pogonowski
Mailing Address, C/S/Z: 88 Old West Mountain Road, Queensbury NY 12804
Cell Phone: 518 )744-6135 Land Line: 518 )798-6964
Email: billa)adkfence com
• Primary Owner(s):
Name(s): Bill&Wendy Pogonowski`
Mailing Address, C/S/Z; 88 Old West Mountain Road, Queensbury NY 12804
Cell Phone: 518 )744-6135 Land Line: 518 )798-6964
Email: .— bill@adkfence.com
Check if all work will be performed by property owner only
• Contractor(s): (List all additional contractors on the back of this form)
Contractor Name(s): _
Contractor Trade:
Mailing Address, C/S/Z:
Cell Phone: Land Line:
Email:
**Workers' Comp documentation must be submitted with this application**
• Architect(s)/Engineer(s):
Business Name: Rucinski Hall Architecture
Contact Name(s): Ethan P. Hall
Mailing Address, C/S/Z: 134 Dix Ave, Glens Falls NY 12801
Cell Phone: (518 )260-2888 Land Line: 518 )741-0268
Email: ephall _nycap.rr.com
Contact Person for Compliance in regards to this project: Ethan P. Hall
Cell Phone: ( 518 )260-2888 Land Line: 518 )741-0268
Email: ephall nycap.rr.com
Principle Structure Packet Revised January 2021
ADDITIONAL PROJECT INFORMATION:
1. Estimated Cost of Construction:$ 75,000
2. Proposed use of the building: Detached garage
3. If Commercial or Industrial, indicate the name of the business: NA
4. Source of Heat: _Gas _Oil _Propane _Solar _Other: NA
(Fireplaces need a separate Fuel Burning Appliances&Chimney Application, one per appliance)
5. Are there any structures not shown on the plot plan?_YES X NO Explain, if yes:
6. Are there any easements on the property?_YES XNO
7. SITE INFORMATION:
a.What is the dimensions or acreage of the parcel? 17,981 SF
b. Is this a corner lot? _YES X NO
c. Will the grade be changed as a result of the construction? _YES X NO
d.What is the water source? _PUBLIC X PRIVATE WELL
e.What type of wastewater system is on the parcel? _SEWER X PRIVATE SEPTIC
DECLARATION:
1. 1 acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be
completed within a 12 month period.Any changes to the approved plans prior to/during construction will require
the submittal of amended plans,additional reviews and re-approval.
2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of
Queensbury.After 1 year from the initial application date, 100%of the fee is retained.
3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or
description of the work proposed, that all work will be performed in accordance with the NYS Building
Codes,local building laws and ordinances, and in conformance with localzoning regulations.
4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of
occupancy.
5. 1 also understand that I/we are required to provide an as-built survey by a NYSlicensed land surveyor of all newly
constructed facilities prior to issuance of certificate of occupancy.
I have read and agree to the above:
PRINT NAME: �IW P 4111l. - AWZ�M&r
SIGNATURE: /t2� / . DATE: lu 2XII
Principle Structure Packet Revised January 2021
Residential Plan Review: 1- and 2- Family Dwellings
Y/N/NA (1 of 2)
Two (2) full sets of plans
Over 1,500 sq. ft. requires engineering stamp
Design loads on plans: 115 Wind Floor Loads 40 psf
(North of Rte. 149 60) 50 Ground Snow Load Sleeping Areas &Attics 30 psf
Calculations Decks 40 psf
Wind design for lake front properties
Light and vent room schedule
l� Window schedule with glass size & main doors/Air leakage < .5 cfm for doors, < .3 cfm for
/ windows/Tempered glass in bathrooms
Door schedule/Main entrance 36" door
Emergency Escape or Bedrooms & Habitable Space
Above-grade: 5.7 sq. ft.
Grade: 5.0 sq. ft.
24" (h) x 20" (w) minimum tr
44" maximum height above door
Window control devices 24" or less 2"d story or 72" above grade
Egress window from basement 5.0 sq. ft.
Floor system sizing per table 502.3.1
Residential check ERI or Prescriptive method T J
All foam plastic on foundation & crawl space covered by 15 minu a thermal barrier
Driveway length: 300' or more-12' width required/500' or more,turnaround required
Foundation drainage on plans, if required
6" drop in 10' exterior grade
Framing cross section for each roof line, vertical fire stopping every 10'where
required/joist spans pg. 127
Ice & snow shield—24"from exterior wall
Platforms at exterior doors
Stairway headroom 6'8"; all stairs 36" width
Stair run and rise
Winder run and rise
tj Spiral stairs meet requirements
tj Smoke detectors—battery backup & proper location, interconnected
Heat detectors in attached garages—as of 4/1/2021
tj Bathroom fixtures—proper clearance
Hall width-36" width
Handrails more than four risers on open sides
Railing&guards > 30"/basement stairs included/closed risers more than 4" in height
Safety glazing notes for required areas
Garage fire separation:%" gable end/5/8" under living space &%" on walls/20 min. door
/J and closer
Residential Plan Review Revised March 2021
Residential Plan Review: 1- and 2- Family Dwellings .
Y/N/NA (2 of 2)
Garage floor sloped
Jr Attic access: gasket seal & R-value equal to roof insulation
Roof over 30"—22" x 30"/Crawl spaces 18" x 24" access
Carbon Monoxide detector outside lowest sleeping area, on every level & interconnected
within 15' of sleeping area
N Soil test results, if required
�L Septic to well or water line separation
All paperwork signed
�� Note on plans energy saving light bulbs 75%
Blower door test agency paperwork
Floodplain Permit required —check map: 2 feet above flood elevation
Hurricane clips required `
�j Floors less than 2 x 10 covered by%" gypsum or 5/8" wood panel
Manuals S &J required for heating system. Cold air return hard piped
Separate room for draft HVAC or hot water heater with fresh air
HRV shown and calculations
Baffles at eaves for insulations and knee walls
1 , Makeup air for range hood >400 cfm
-� Continuous header for garage doors to end wall/3" nailing pattern/strapping
Chimney rain cap shown for fireplaces
Deck hold down shown not less than 4 lags and bolts per table 507.2
%dential Plan Review Revised March 2021