Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2003-592
TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 1280002 (518)761.8201 Community Development.Building&Codes (518)761.8256 nrDT 1 1 TE Permit Number, P20030592 Date Issued: Thursday, October 04,2007 This is to certify that work requested to be done as shown by Permit Number P20030592 has been completed. Location: 7 BLACKBERRY Ln Tax Map Number, 523400-289-018-0001.032-000-0000 Owner, DANIEL&CHERYL WILLIAMS Applicant: DANIEL&CHERYL WILLIAMS This structure maybe occupied as a; Fireplace By Omer of Town Board Garage-2 Cars Attached TOWN OF QUEENSBURY Single Family Dwelling 0 Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Cade Enforcement Planning Board or Zoning Board of Appeals, TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20030592 Application Number: A20030592 Tax Map No: 523400-289-018-0001-032-000-0000 Permission is hereby granted to: DANTEL& CHERYL WTI.T.IAMS For property located at: 7 BLACKBERRY Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: DANIEL& CHERYL WILLIAMS Fireplace 509 GLEN St Garage-2 Cars Attached GLENS FALLS,NY 12801-0000 Single Family Dwelling $240,000.00 Total Value $240,000.00 Contractor or Builder's Name f Address Electrical Inspection Agency Plans&Specifications 2003-592 7 Blackberry Lane Queensbury,NY 12804 2369 SQ FT SINGLE FAMILY DWELLING WITH 2-CAR ATTACHED GARAGE WITH 2 FIREPLACES AS PER PLOT PLAN SPECIFICATIONS $363.68 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,August 20,2004 (if a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T qf Queen ury; a nesday,August 20,2003 SIGNED BY for the Town of Queensbury. Director of Buildin Co Enforcement Porch, Deck, Dock, or Boathouse Permit Application Town of Queensbury-Dept of Community Development,742 Bay Road, Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. No Permit File No. r)gb3,3� inspection will be made until applicant has received a valid Fee Paid $ building permit. All applicants'spaces on this application must be Reviewed By: completed and must appear on the application form. Applicant: T)"1R., hwhA45- Owner: O"IPA, IbILMi45 Address: '5Qq Of ST, Address: t3001 A 1,0,rj �r Phone#(r4% )_-6t- 460 Phone#( 9- 46 - '. Email Address: Email Address: Person Responsible for Supervision of Work as Regards to Building Codes.- Nam-�4qA, [Mz hLU ,5 Address: 6 LkA Phone llkaq Property Location: Lot Number: House Number Subdivision Name: Tax Map Number: Estimated Market Value of Construction: $ ;)-Sv• AFV-3� u Porch .9 Deck L3 Dock Ei Boathouse Ll Other work(describe Size of structure to be built square feet Submit along with this gpplicatio 1. Two plot plans drawn to scale,preferably using a survey map. Indicate proposed structure showing setback dimensions from all property lines. Show location of water supply and location and configuration of septic disposal area. 2. Two sets of structural drawings. Indicate size of posts or studs, floor joists, decking or flooring material to be used. Show how the porch or deck will be fastened to the building. If a roof will be constructed, indicate the size of posts or studs,roof rafter spacing and span. Indicate type of roof. sloped, flat, shed,or other. Indicate the type of material being used for the roof. Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the prop ed work all b co ied with,whether specified or noted, and that such work is 'r OW authorized by the ole signature: D Applicant's signa e: ate: L-\SucHemingNvay\Building.Permit.FORMS\Porch.Porch.Permitdoc 8/13/02 revised per DH BLDG. PERMIT NO.-2 0 0 3-5 9 APPLICATION FOR A TEMPORARY CERTIFICATE OF OCCUPANCY ANIFL,, 9 SHFREE WiLL1,A S A TEMPORARY CERTIFICATE OF OCCUPANCY is hereby requested for the property located at; % Bt-acizbe/my Zone for the following uses: Singte Fames DWe&-:4ng 1 _ AUgL&S,: 23, 2004 DATE SIGNATURE 4 A PLICANT { '.YN':RCfr TEMPORARY CERTIFICATE OF OCCUPANCY The TEMPORARY CERTIFICATE OF OCCUPANCY is hereby MOA'PPROVED ( )DISAPPROVED with the following conditions: CeirtiecZte o� t�ecupancy be il�due upon compZe;;x,on a j: 1) CompkUe aU hcandnaZU and.gucvcd,6 @ 4xont poach and deck. ade. F-i,na- Scow t TEMPORARY CERTIFICATE OF OCCUPANCY $10.0 D POSIT,4 ( $100.00 received on November 23, 2005 Date of Issuance Director of Bldg. & Co Enf cement THIS TEMPORARY CERTIFICATE OF OCCUPANCY EXPIRES 90 DAYS { FROM THE DATE OF ISSUANCE. NOTE: This Certificate is NOT VALID unless signed by the Director of Bldg. & Code Enforcement or his designee. Building Permit Application Town of Queensbury Department of Community Development,742 Bay Rd.,Queensbury,NY 12804 b (518)761-8256 Q A pennit-niust be obtained before beginning construction. Permit No.: / No inspection will be made until applicant has received a Fee Paid: o�. valid building permit. Form must be completed. Rec.Fee Paid: ' Reviewed By:, Applicant: { Owner:_ Address: Address: Phone#: Phone#: Tax Map Number: U Subdivision Name: (if applicable) Lot Number: 1 House Number: b 1 Street Name OR Property Location: �W*-, New Building: esidential Commercial Estimated Market Value of Constructiont-i o o Addition: es�Commercial If an Addition,what will use of addition be? o Alteration: Residential I Commercial o No change to Exterior size: Residential/Commercial ❑ Other work: (describe } Check Below Occupancy Info 1"floor sq.ft. 2 Id floor sq.ft. Other floor sq.ft. Total Sq.Ft. Single Family Dwelling Z Two Family Dwelling Townhouse Multifamily Dwelling #of units Office Mercantile Manufacturing I car detached garage 2 car detached garage 3 car detached garage 1 car attached garage 2 car attached garage 3 ear.attaehed garage Storage Bldg.,Comm. Storage Bldg.,Res. Other What is the proposed height of the structure: feet inches Will any second-hand or ungraded lumber be used? If so,for what? O No.of Fireplaces to be installed:No.of Woodstoves to be installed: List below the person(s)responsible for supervision of work in regards to Building Codes: Name Address Phone No. Builder Plumber 00 Mason p �. 5 Fir Electrician —'L 3 Declaration: Please sign below after you have carefully read the statement: --- To the best of my knowledge the statements• contained in this application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code, the Zoning Ordinance and all other jaws pertaining to the proposed work'shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that Uwe shall submit,prior to a Certificate of Occupancy or Certificate of Complia�tt bein issued,as requested by the Zoning Administrator or Director of Building and Codes,an As Built Su y by ce e s eyor;drawn to scale,showing actual location of all new construction. ink Signature: ___ (circle one er, wrier agent,architect,contractor) Application for Permit=Septic Disposal System Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8256 1. OWNER INFORMATION: /t���{ ............................................................................................................................... Location of installation: � (ij � { �—� Office Use �? J p File Permit No.C� Tax Map No.- Fee Paid Owner's Name: Iy�� j�bi/[ ......................................................................................... Address: V 0 (14A �A&OA 2. INSTALLER'S NAME �1 9�[�� �X PHONE NO. -(0(0f 1- 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No.of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gal/bdrrn = 1980— 1991 x 130'gal/bdrm = 1991 —present _�� x 110 gal/bdrm = j'lj E7 Garbage Grinder Installed yes J no Spa or Hot Tub Installed yes Y, J no 4.' PARCEL INFORMATION: (circle applicable information&indicate measurements) Topoaarayhv Soil Nature Ground Water Bedrock or Impervious Material Domestic Water Suppl Flat sand at what depth at w at depth municipal o tin oam _feet feet we Steep slope clay if well; water supply _%slope other from any septic-system depth: absorption is too ft. other Percolation T�o be completed by licensed professional engineer or architect) Rate: minute per inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: (7,'�D gallon (min. size 1,000 gal.) Tile Field: each trench ft. Total System Length:��ft. Seepage Pit(s): -number of size of each: ft. by ft. Size of Stone to be used: # / de pth or thickness feet Bed System Size: 9Dx l� Alternative System: length and/or size 6. HOLDING TANK.SYSTEM: (if required) Number of tanks: J Size of each: gallons /TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations with respect to this application and agree to abide by these and all requiremen of the,7c%fQueensburySanitar-vSewajzeDis-posal'Ordinance. V At 4,Z ..�� Si ature f resp sible person Date '1 invet t;f <2uac ti:tbILI,ry :lti(f :iiswone Disj)osat t:l:sitstt`:• ,t�,hlsrtttli x t; � • •.�-;SII'/�ftA''l'l,t)1N lt•'i;t2i.3lltt�lll Ii;t�l'I`;i •:.. = ". : . - • - [ . - _ _ .cam`.. S .4 �t t F:• _.. .._ _._._..��.�• ..y -1"rests pphtt? � Y`IE.Lt.. 1�l 1tATrt'tZ- -+' �'`-•�'���+••�-(it �t'.wt ------------ t= r G � t ' {_C,' {(t ,� ./'�~ Sc r•tic;. � �^(t A�Y`.rriRf't'tCt i ' 7. SIGNATURF— &INFORMATION POP,1 Ycart��ss.� ���•,�� �r:�r*•�.:•.::=; BLDG. PERMIT NO. 2003-592 APPLICATION FOR A TEMPORARY CERTIFICATE OF OCCUPANCY DANIEL 91 .SHEM WILLIAMS A TEMPORARY CERTIFICATE OF OCCUPANCY is hereby requested for the property located at;, 7 S ackbevLy .bane for the following uses: Single Family We:Mng i - Augmt 23, 2004 DATE SIGNATURE O A PLICANT TEMPORARY CERTIFICATE OF OCCUPANCY The TEMPORARY CERTIFICATE OF OCCUPANCY is hereby {V'APPROVED ( )DISAPPROVED with the following conditions: CeA a6icaze a OccuPaytt� to' be izzued upon conip4e;rLon o6: 1) Compteze oU handu,cU and..guan" @ ,4unt pohch and deck. 2) Comp4ete I:nz:Ca. Zc. ci6n 06 Bowen; 3) Comptete (jinat grade. G_) - Fincz>L' -cuaveu, TEMPORARY CERTIFICATE OF OCCUPANCY $10.0 D POST { $100.00 received on Date of Issuance :.'Director of Bldg: & Co Enf cement THIS TEMPORARY CERTIFICATE OF OCCUPANCY EXPIRES - DAYS' FROM THE DATE OF ISSUANCE. NOTE: This Certificate is NOT VALID unless signed by the Director of Bldg. & Code, Enforcement or-his designee. ENERGY CODE COMPLIANCE APPLICATION C TOWN OF QUEENSBURY, WARREN COUNTY 9000 BEATING DEGREE DAYS Compliance Methods:Part 5 -Acceptable Practice Method— 1&2 Family Dwellings (only) Part 6*-Thermal Rating—Component trade Offs 1&2 Family Dwelling; Multi-Family Dwellings(3 Stories or less) Part 4*-Design by Component Performance,Commercial Buildings-Hi Rise Residential *Requires submission of worksheets AP LICANTS NAME: PROPERTY LOCATION: b b I Kkam We, I A PART 5METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE: I Gross Floor Area— 1169 square feet 2. Type of heat- Electric oil Gas Other 3. Is building mechanically cooled?_yes ..�_No 4. Percentage of area of windows and doors Over 17% Under 17% 5. R-VALUES FOR INSULATION GIVEN BELOW MUST CORRESPOND TO R VALUES AS SHOWN ON PLANS SUBMITTED: R_W a. Roof b. Exterior walls C. Glazed areas d. Exterior doors R:jK e. Floors over unheated spaces R 10 f. Edge of slab on grade(heated-building) 9. Basement/cellar walls (above grade) h. Basement/cellar walls (below grade) R i. Heating/cooling-ducts-piping in unheated space R 6. Service(domestic)hot water heating device Conforms to minimum efficiency per code Yes No TEMPERATURE CONTROL MAXIMUM SETTING 140—WILL NOT BE EXEEDED i 'S re — Date Phone Number cW INSPECTOR'S REMARKS: Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY (518)761-8205 :Application for Fuel Burning Appliances &,Chimneys applicable to solid fuel & vented gas appliances _i c�, Date 20 _ t.) Permit No. t-_V A Application is hereby made to tlrc Bul , ' ng&Codes Office far the issuance�f a Building and Use I I Per init pursuant to the New York State T-ire Prevention ai applicant or-owner agrees to comply with all applicable laivs, ordinances, reguldtiohs, and all conditions'theft are part of - these requirementi'and also will allow all ippectors to enter preinise' s','to perform reqitired inspections. ---N--OTE to a P'01,icant* ' .R6ugh-lln and Final Inspeeti- �:ar.,eyequired. Applicant-.Information Fuel Burning Appliance Information -1 (circle appropriate words) Stove: wood coal pellet gas Fireplace insert Address:(�!344 _Ool-;,� Fireplace;factory-b'di t- .-` .woo ga� ', Fireplace, masonry: i-vjod as Furnace: wood p oil Phone: rol If non-masonary applipance, please provide fLturer Name: wl I Owner., Wl(!,f i,i��I 9_011�(1' ManA� Address: 0 r,j Model Number: Chimney Information Phone: (circle appropriate words) Masonry, block brick stone tile; :,4—e size: ze: Flue inches te Exact Address: ri,avw li-6 L-1, ,A-fR_ of eotistruc6n or histal&tIon Factor) uilt Manufacturer name: Model Number: .Note' Listed By:,' Number: stallatiowniu-'v Construction.i.710 P!1, 4 conf brin to NYS-TW, )'�e'yA ntion &Building Indicate(circle) chimney material: Code. Consult available Town of Queensbuiy Handouts regarding required inspections., wall I Triple ivall l Insulated •Direct venting Chimney Liner C-"_ Fire Marshal Code# Collected S Refunded Recehedfi-oi (i-e;fiii(deil to): A�6�; address: A 173 3389 (190) Public Safety A 233 2655 (230)Minor Sales DATE; White(Applicant) Green(Fire Marshal) Yellow(Bldg.Dept.) Pink&Goldenrod(Cashier's Dept.) r UA S BP Project Name:_ � BP# Address: �Y__ � Building Permit Submission SFD Checklist 2-Family All items below must be checked either yes,no or not applicable prior to submission of any building permit to the Town of Queensbury Building Department. If any of the below items are lacking,the permit will not be accepted until such time as the application is deemed complete for submission. 1. Building Permit Application Completed ... ... ... ... ... ... ... ... ... ... ... ... . Ayes ❑ no ❑n/a 2. Energy Form or CheckMate Energy Code Compliance Forms Complete.. yes ❑ no ❑ n/a (2 copies) 3. Energy Code Inspector's Report from ChecklY[ate Program... ... ... ... ..... yes ❑no ❑n/a (2 copies) 4. Septic application completely filled out(if applicable)... ... ... ... ... ... ... ... yes ❑ no F n/a 5. Solid Fuel Burning or Gas Appliance Form... ... ... /r jjjj ❑ ❑ 6. Electrical Inspection Form... ... ... ye Ono ❑ 7. Two (2) complete sets of structural drawings... .. ... ... ... ... ... ... ... ... ... ... . *Ies '❑no ❑n/a a) floor plan;b) foundation plan;c) cross sections:d) elevations; e)window and door schedule 8. Two (2) site plans showing location of the structure to be built.... ... ... ... iAyes ono ❑n/a location of well or water lines,location of septic system or sewer line. 9. Setbacks from property lines to new structure ... ...... ... ... ... ... ... ... ... .. Xyes ❑no ❑n/a 10. Setbacks to neighboring wells and septic systems,including onsite well.... %yes ❑no ❑n/a and septic systems (if applicable) 11. DrivewayPermit... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... yes [:]no ❑n/a Date: Staff Initial: -7 Oy L:\SueHemingway\Building.Permit FORMS\Generic Ghecklist.doc January 28,2003 0 6-6-g2 Check Residential Plan Review: One&Two Family Dwellings Y/N/N/A/ (2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: rWindow Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK V1 Dampproofing/Waterproofing Materials On Plans Foundation Drainage On Plans,if required "Drop in 10' Exterior Grade V/ Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls /Platforms At Exterior Doors ay Headroom 6' 8'-All Stairs 36"Width V Stair Run and Rise 411� Winder Run and Rise Spiral Not Allowed From 2nd Story Amoke Detectors Battery Backup and Proper Location V/ Bathroom Fixtures Proper Clearance Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht- Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped rz-R - DRAj-Ass DA a, L.6 ft,r Attic Access 'S A,)(P cc-625 Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results,if required Septic To Well Or Water Line Separation --rAll Paperwork SignedSigned �queensbury Building & Code Enforcement- side 'al a spection Office No. 51$ 761-8256 { ) Arrive: m/pm m Date Inspection request received: Inspecto s In'gq a i NAME: 0 �y� , P IT M LOCATION: TE: TYPE OF STRUCTURE: Comments Yes No N/A f _ Building Number/Address visible from road �j� " l I�" ChimneyHeight/"B"Vent/Direct Vent Location J Fresh Air Intake 3 inch Plumbing Vent through ioof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill late Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety,glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Batterybackup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-ISO s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat.Tra /Water Temp 110 Enclosed Stairs Sheetrock Underside minimum Y2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Se tic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0 Temporary/ ermanent L:\Building&Codes FormslBuilding&Co Les\In�ctionForms�Residential Final Inspection Form-revised-1 00405 doc 'IFJIlxzvl ]E>opt- of 4Cc>iaaxirjLviriity rc�vvrl C>F 742 Bay Road 12804 T-T-A-MIB: IPIF-I:Z-Mll-r Final Survey Plot Plan Denied 'The attached final survey ll.as been received 1:),y the Dept_ of Craig 2L NOV- O -AL 2005 -T-C:>VV" C:)j= <D U F-_-a N E3 U FRV-e T=F I Q F- Su-vk-'y MAP REFERENCE: MAP OF A SURVEY MADE FOR ELIZABM O'CONNOR LITTLE Us VAN DUSEN + STEVE5 DATEDs MAY 2002 LA5T REVI5EDs JANUARY 28. 2004 LANDS N/F OF POLUNCI ` �' LAND5 N/F OF \ 5tIERMERt10RN O sus 0� ��� ti°'�� 44 /h 00 � A ail 1 ; s rROPANE Tr WELL 2 5TOR LAND5 N/F OF WOOD rRA \ / POVIE MOU5r, - -- 22f,443.6.3_sq.ft. CIA - 5.08 acres ° A5PHALT .0 I DRIVE \ \ i do S92 6�E,o \�o� `�. rFSr �• Oa � � BMN 579 p RECEIVE OO O LAND WILD F OF NOV U 1 2� . h TOWN OF QUEE BURY �hh BU1=ANDCODE - 161 .63 w � F� LEGNED: w LAND5 N/F OF N38*3i U / N —o— = WOODEN FENCE LINE WILD IL - UTILITY POLE f � ys'F �50135 j / d Dates SEPTEMBER 29, 2005 %""'°M=Kam"°"a ADMUN TO A 9AnV Scale 1'=60' MW KA�A LbCDOW LAND SUNWAM IK B A Map of a Survey made for MOLAIN W SEMM 72A BM•OABION 1 W W Steves 0"I=SGTi MUCK 10N Ur• ONLY VAIN m AK of ft DK SI= YARf®1YTN AN OMIOINN.a'11E 1AtD 31RYEYOSS ry SfAI.E1WLK TO V"V"QWW 1 T TK DMT WILLIAMS 1 and Survey ors W�"C°`°-'�°"F°`"° MY YY TE NL7 YOIMI STALE ASSOCNl10N OF"lOi7'45MINAL WAD 9Mt1ETONi f�D OFRTMIG101S M0 N M%O A QIIGG 1 VI— f TO TN£PEASOII FM rlIOY 81E SUM1tY B PpEPARf7A Nq ON!MS MENA{F W THE 4AE OOYPANY.001FlMIMORAL 169 Haviland Road Queensbury, New York 12804 T n M `";"Jw AM Town of Queens►fury, Warren County, New York 518 792-8474 New York Lie. No. 50135 wILLI. 0 C1635 � � N0. DATE DESCRIPTION DWG. No. o2114a ZS 18-1-32 i I I i Queensbury Building & Code Enforcement - Res' e ti nal Inspection Office No.(518)761-8256 Arrive: pm art; a m Date Inspection request received: _ _� Inspector's Initial : '' 0�� �;NAME: t`\ C�'1�p PE IT#: LOCATION: _ D E. _ TYPE OF STRUCTURE: Comments' Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 1 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks, atios Guard at stairwell at 34 in. or more Guard at deck,por6es 36 in.or more Exterior Finish Complete Interior/Exterior Railin s 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers ��✓y� — Enclosed Stairs Sheetrock Underside minimum I" �•7 Gypsum 0 Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate /t Gas Valve shut-off exposed/regulator 18"above grade. I / Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area ! O� Fumace/Hot Water Heater operating l j Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 @ JJ Interior privacy/trim/doors/main entrance 36 in. t Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: �9 Every level: 1 Every Bedroom. C Outside every bedroom area: Inter Connected: I Battery backup: r 'Carbon Monoxide Detector .Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches CZ� y��j� •� � ��� p Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly �— Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.00 In accessible area Crawl Spaces 18"x 24"access, I s . f1.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance re uired Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/0 Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res,Final Insp.form 2.docLast printed 2/12/04 Residential Fih� al Inspection Joh n Inspection Office hi ,ce No. (518) 761-8256 Date spre I st cc eclion Queensbury Building&Code Enforcement Arrive: m/p D art: 4j,'VCt:a5'W_ 742 Bay Rd., Queensbury,NY 12804 Inspector's Initia NAME: T M LOCATION: %0,1,1 .a 413. -1, TE: ,30 aftL TYPE OF STRU(j4�ME: E Z Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location _T EAVIO VAR� C-0 C Z OD VVk Fresh Air Intake 7 / 3 inch Plumb Vent through roof \6 Roof Comple I I/� Guard 30 in.or more @ stairs,decks,patios (1) 1 1 Guard at stairwell at 34 in. or more V Guard at deck,porches 36 in.or more Exterior Finish Complete o Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace jj�ate'r�Heater Tpe-rMn—O V, Low water shut-_off 551're�r Relief Valve(s)installed - Interior ----------— privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazina V/ V Window in stairwells safety glazing Interior Smoke Dete tors: Every Every Bedroom: Outside every bedroom %7 Inter Connected: + / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures ZOjr!�,, jLgA?_ Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches %hour fire door/door closer Garage fireproofing Duct work Sealed properly Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible.area V/ Crawl Spaces 18"x 24"access, I sq,ft.-150 sq. ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance require Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification,if required Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C I 0(Cert. Of Occupan Okay to issue Permanent C 0(Cert. Of Occupancy) L:\SueHeniing,,vay\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003 Septic Inspection Report Office No.(518)761-8256 Dat6 Inspection request received: Queensbury Bu ilding&Code Enforcement Arrive: an��part: am/pm 742 Bay Rd., Queen7sbury,NY 12804 Inspector's Initials: nj 614 A, NAME: PERMIT NO.: LOCATION: INSPECT ON: RECHECK: Comments a)ftd/or diagram Soil Type�: arn Cl Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance Other wells: Absorption Field: Total length ft. Length of each trench Depth of trenches Size of Stone -Seepage Pits: Number Size: x Stone Size: Piping SiZ)f Typet_ Building to tank Tank to DistributioA Box Distribution Bo tie d Pit Opening Seale j XZ/NI Partial I I Location/Separations Foundation to tank f ft" Foundation to absorption t. Separation of Pits L,Confonns as per Plot Plan VY N Loc * n stem on Property: Front Rear Left Side Right Side Middle Front iddle Rear S stem Use Statu Approved Partial Approved and needs to be re-inspected,please call the'Building&Codes Office -Disapproved L:\SueHemingNvay\Building.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 Vi. �Queensbury Building & Code Enforcement - Residen 'al-Final Inspection V/ Office No. (518)761-8256 Arrive: VDE: De•art: i )t Date Inspection request received: — Inspector's InitialCj tNAME: MLOCATION: Gam( , TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location -- %� Fresh Air Intake V� 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @stairs,decks,patios - Guard at stairwell at 34 in. or more YA Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railin s 34 in.to 38 in. tQ Platform at all exterior doors Interior Handrails stairs 2 or more risers NL Enclosed Stairs Sheetrock Underside minimum'h" Gypsum Grade away from foundation 6 in.with 10 ft. � Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above rade l C-®L4> '1' A P— AD We— Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace rea Furnace/Hot Water Heater o eratin Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detyctors: Every level: 1 Every Bedroom: Outside every bedroom areas- Inter Connected: JI Battery backup; " 1 Carbon Monoxide Detector All" ' Bathroom Fans, if no window W/ Plumbing fixtures Foundation insulation Z Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/a hour fire door/door closer —rV-1 iA 0 L� Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure ,r - Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, I s . ft.-150 s .ft. vents Building No./Address visible from road Final Electrical / Site Plan /Variance required Final Survey Plot Plan , �-�� As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification,if re ui Okay to issue C/C or C/jRnemporary/ ermanent L:\PamW\Building&Codes\Insvection Forms\Res.Final Insu.form 2.docLast printed 2/12/04 Town of Queensbury Fire Marshal's Office 742 Bay Road "Romp, Queensb4ry, NY 12804 Phone(518) 761-8205 Fax(518) 745-4437 Fire Marshal's Inspection Report Request SCHEDULE Received: Permit# (2 359 a INSPECTION ON: Name: AM ,YL KM NYTIME Location: 11-11 -- AFFRUIV N/A YES- NO I COMMENTS EXIT ACCESS IRV EXIT ENCLOSURE EXIT DISCHARGE MAIN AISLE WIDTH SECONDARY AISLE WIDTH EXIT SIGN-NORMAL EXIT SIGN-BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHER HUNG FIRE EXTINGUISHER INSPECTION V�: FIRE EXTINGUISHER HYDRO FIRE ALARM SYSTEM FIRE ALARM =FAN SHUTDOWN FIRE SPRINKLER SYSTEM FIRE SUPPRESSION-KITCHEN FIRE SUPPRESSION-GAS ISLAND HOOD INSTALLATION INTERIOR FINISHES STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO ELECTRICAL ELECTRIC WIRING ENCLOSED COMBUSTIBLE WASTE VEHICLE IMPACT PROTECTION FIRE LANE F.D,,SIGNAGE-UTILITY ROOMS Ka-SMOKING SIGNS ,MAXIMUM OCCUPANCY SIGN EMERGENCY EVAC PLAN OK THIS OATE OK FOR C OT OK �jf I Olt, INSPECITED-BY COMDEV/CHFUSJNVORD/LETTERS2001/FIREM§ZZ RSHALINSPE.CTIONREP0`/RTil-#1022001 WHITE-BUILDING DEPARTMENT COPY (jYELLOW-OCCUPANT COPY COMMONWEALTH ELECTRICAL INOECTION SERVICE, INC. 1 Main Me 176 Igoe Run Road - Manheim, PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL �'ermit Na! 41i11ilii 14, 4111N,f #, 1„#,1,1„1# e # NO 8 1124 Cut-in Cardoi � N! ! ! #ifi„tr141##1 41!!il##ii1N I }i��i ltN4H/!t#itf,u,ilfffttfirlf,rfllnufF!!!4i#! !#fNllttl4!#t!4!!#N4fffltftt,ifff,i,fuf,iff!lf4lfiifFli!!f/!lf,lfr4!!4!fl4lfrr4!!,!!,#!1!4#f4t1414#l14t4441#!,1 1,� # r { + LAI �ocatton flfif�f!#u4mrrfifilll#iif!##Ftillt#111IHillli/Ntllt11rt1ra,Iflflrflfflnriff!lI rlrifi4,inf1,ilf„!„i1ff,1, irllfffii1r1,1fi1f,lNl Installation Consisting of,,,,,,,, 11NIIIttrli!!filr„N!f tii! #f{il!##f111114t#triNil,rl4iii 77;S i#i111i,ftriilfllf,irii !lfifrflfNi,rllf4iilflfflNifrffiii! f11114114141#1 wi k� � pfgltFlltoo t ii 111 #4fiiil4t141111N!!44#N 1161 irll 10 f ! M N1 oil to f Ih11#16 lif,iNiffif,iNlfflffilMfilf,iflfl{NiflfrlNiiiifl{f„1lfflHilfl!{Ififll i 1l11 444114lIiNi!l4i1!#iFilti 4111411N#F !!iil#Fi,l1i#1i!#1#i1„filif#,flitl!!14li#llt4l1111NIN#fF!l11111#11!#fi#Iifi#!#•i�i Fl�lf�N/Ni1/1�t+lrri 1fi#�#t/,#f#tNt/,itrlr#If1111 InstalledBy1111111#111111 toil/Iloilo 11l411111441t111,f�4!"41r,if1111i##11#911 i II 11#010011 1IM11161of 1111 Lic, No, llNiifllffll14111f#f111NllffNiiilllffllilllfili � a The conditions followingoverned the issuance of this certificate and an certif scat roviousl issued is � Y p Y cancelled: - This certificate only covers the electrical equipment and installation conditions as of date, Upon the introduction of additional equipment or alterations, application shall be promptly made for inspection, Inspectors of this Company shall have the privilege of maki g spections at any time, and if its rules are violated, the Company shall have the right to to a this ertr scat Date,,,,, INSPECTOR 11Nif1111if11,,,if11{f1 !#f11111t1f1#t111 ffii ! !!!irlfriilif#itHttitlit141ti!!fi#,rfirNf+,«lfi�i�liilflf!!ii!!ii{!{fii{!i•N!� Unw"kmM u Vie A i A c i Queensbury Building & Code Enforcement - Residential Final Inspection 0 �� Office No.(528)761-8256 Arrive: d�--=am/p Depart: am/pm Da�nspection request received: Inspector's Initials: _ NAME: PERMIT#: S LOCATION: DATE: TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more stairs,decks,patios Guard at stairwell at 34 in.or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %Z" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,.draft stopping finished basement 1,000 sf Emergency a ress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl S aces 18"x 24"access, l s . ft.-150 s .ft. vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required cd d1�t1'b Oka to issue C/C or C/O Temporary/Permanent .I L:\PamW\Building&Codes\Inspection Forms\Res, Final Insp.form 2.docLast printed 2/12/04 Rough Plumbing 1 lnsul,, tion Inspection Report Office No. (5 18)761-8256 Date lilspection request re request re *v Queensbury Building&Code Enforcement Arrive: M art: 742 Bay Road, Queensbury,NY 12804 Inspector's Initia P IZMTT NAME: 0 1 PERMIT'#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y IN N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents, 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper,CPVC,Pex One and Two-Family V"Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly No duct tape COMMENTS: L-.\SueHemingway\Building.Codes.inspection.FORMS\Rough Plumbing Insulation Report.doc November l7,2003 Framing /Flresto ping Inspection Report Office No.(518)761-8256 bate Inspection req re Queensbury Building&Code Enforcement Arrive: a p art: an pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initia s: NAME: PERMIT#: 03-- F- LOCATION: ��� � Y, �p INSPECT ON: — TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing!Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 3 6 in. or more Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 f2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour estopping Penetration sealed 16 inch insulation in cavity min. b�� Garage Fire Separation House side%Z inch or 5/8 inch Type X a � � Garage side 5/8 inch Type X G Ceilin /wall r V Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:iSueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc Jamiary 28,2003 Framing/Firestopping Inspection Report Office No. (518)761-8256 Date Inspection re st ece' e Queensbury Building&Code Enforcement Arrive: m/ aA p 742 Bay Road, Queensbury,NY 12804 Inspector's Ini 'al -- NAME: �� 1CS 1 PERMIT#: CJ Sq LOCATION: INSPECT ON: —� TYPE OF STRUCTURE: SF / Y 1oT N/A COMMENTS raming Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. --� 1 --�,� Headroom 6 ft. 8 in. 40 Stairwells 36 in. or more Headroom 6 ft. 8 in.- Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 Iz(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft. floor trusses Anchor Bolts 6 ft, or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall,2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. ( ) 5.7 sf above 1 below grade 5.0 sf grade L:\SueHemingway\Building.Codes,Inspection.FORM5\Framing Firestopping Inspection Report.doe January 28,2003 -AC)- Town of Queensbury Fire Marshal's Office low 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(518) 745-4437 Fire Marshal's Inspection Report Request SCHEDULE Received: _—Permit# INSPECTION ON: �: r —13 Name:----1 1 5 aca .- __. ______.� - "_ AM P IME Location. {�C e, APPROVED f N IA YES NO V COMMENTS AISLE WIDTHS EXIT SIGNS::NORMAL Imo © v�v V J - BATTERY !_ EMERGENCY LIGHTING _ FIRE EXTINGUISHERS � � FIRE ALARM SYSTEM _ 3 FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM _ HOOD INSTALLATION _.. _ �Y INTERIOR FINISHES _ STORAGE COMPRESSED GAS— CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING+ �, t D5�oA� UNITS `-� CLEARANCE TO ELECTRICAL REQUIRED SIGNAGE a EMERGENCY PLAN_ MAXIMUM OCCUPANCY_SIGN CHIMNEY �^ T MASONRY ROUGhIIN FINAL FACTORY BUILT ROUGH IN FINAL WOOD STOVE ROUGHIN FINAL VENTED GAS - APPLIANCE ROUGH IN FIREPLACE �� �FINAL --- MASONRY _— ROUGH IN OK THIS DATE 0 F(5 O NOT OK _�_ FIREPLACE FINAL ^- FACTORY BUILT ROUGH IN INSPECTED BY FINAL COMBEVICHRISJtWORDILETTERS20OI/FIREMARSHALIN TIONREPORT11022001 WHITE-BUILDING DEPARTMENT COPY 4� YELLOW-OCCUPANT COPY Rough Plumbing 1 Insulatio Inspection Report Office No. (518) 761-8256 Date Inspection request lved: di Queensbury Building&Code Enforcement Arrive: pm Depart: am�6�7 742 Bay Road, Queensbury,NY 12804 Inspector's In' ials- (&J, PERMIT #: NAME: Pral�livl- E LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates I % inch min. Drain Size Washin ine- ' 2 inch min. ad,or Air Supply Test'*N Drain,and Vents 5 PSI or 10 fee�t�abiphest -,--cAnuaed:ou-15r 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Fandly I!2-r- fi_p Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November]7,2003 Framing/ Firestopping Inspection Report Office No. (518)761-8256 Date Inspection strece' ? Queensbury Building&Code Enforcement Arrive: am/ m art: 3 c0 a pm 742 Bay Road, Queensbury,NY 12804 Inspector's itials -7 NAME: z l C' PERMIT#: 0_3 t� LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts b ft.or less on center Ice and snow shield 24 inches from wail Fire separation 1,2, 3 hour Fire all 2, 3,4 hour Irestapping Penetration sealed 16 inch insulation in.cavity min. � � Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) � 20 in.(W) { 5.7 sf above/below grade 5.0 sf grade L:\,SueHemingway\Suilding.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Rough Plumbing.-I Insulation Inspection Deport . Office No:(5I 8)761-8256 Date Inspection request received: ueensbu Building&Code Enforcement Arrive:yam/ a art: a mlp-m •Q g a 742 Bay Road, Queensbury,NY, 12804 Inspector's Initials: — � ,NAME: ��� �1`�`�` J PERMIT #: LOCATION: INSPECT ON: -- TYPE OF STRUCTURE: . Y N N/A PVC: R-1,- R-2,R-3,R-4 Drain/Vents " Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place ., . Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply,Test ,--(t,-5 Drain and Vents. 5.PSI or-10.feet above highest (1:5-JCIAJ61 connection for 15 minutes Cleanout every 100 feet 1 change of direction Water.Supply Piping Cooper Commercial o er,CPVC,Peg One and Two-Fandl , nsulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion"i $li l for Furnace - Duct work sealed ro erl /No duct tape ^� COMMENTS: LLSueHemingway\Building.Codes.Insgection.FORMSIRough Plumbing Insulation Report.doe November 17,2003. Rough Plumbing / Insulation Inspection Rep Corte Office No. (518)761-8256 Date Inspection request received: G Queensbury Building&Code Enforcement Arrive: am/pm pa amlpm __ 742 Bay Road, Queensbury,NY 12804 Inspectbr's Initials:. NAME: I yjdm5 _ PERMIT #: " LOCATION: INSPECT ON: S c� TYPE'OF STRUCTURE: Y IN- N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain, and Vents 5-PSI or 10 feet,above highest connection for'l5 minutes Cleanout every 100 feet 1 change of direction Water Supply Piping Cooper Commercial Cooper,CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check 110*1 ro er V ttic Vent C6 1ID- uc of Water Piping ation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed property/No duct tape COMMENTS: L 1SueHemingwaylBuiiding.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Framing J Firestopping Inspection Re Office No. (518)761-8256 Date Inspection r ue rec ved: Inspection R.on r e rec v Queensbury Building&Code Enforcement Arrive: epart: am/pm j 742 Bay Road,Queensbury,NY 1.2804 Inspector's Initii#s- I�A!S P M NAME: PERMIT#: '7 T=)3 T571' Z INSPECT ON: LOCATION: 77 aL ek�!J- TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Jack Studs Headers Bracing Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 Y2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft,floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall,2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire-Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade LASuel-lerningway\Building.Codes.Inspection.FORMSTraming Firestopping Inspection Report.doc January 28,2003 Framing /Firestopping Inspection Report Office No. (518)761-8256 Date Inspection re st r cei Queensbury Building&Code Enforcement Arrive: pm . e m ATr 742 Bay Road, Queensbury,NY 12804 Inspector's Initi NAME: k'J6 11 ryvx- n PERMIT#: LOCATION: -7 Pp gs-!I�N I INSPECT ON: Z� TYPE OF STRUCTURE: Y N /N/A COMMENTS Xaming Jack Studs/Headers Bracing/Bridging Joist hangers I V, \1�1\b%-\ '�QLA(—N�-'>(--::> Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls ND\t Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft,floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour re 12, 3,4 hour Ping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.0 20 in.(W) 5.7-sf above below grade 5.0 sf grade L:\Suellemingway\Building.Codes,lnspection.FORMSTramingFirestopping Inspection Report.doc January 28,2003 Framing Firestoppin9 Inspection Report Office No, (518)761-8256 Date Ins pectionLT-equest received: Queensbury Building&Code Enforcement Arrive: f' a a 742 Bay Road, Queensbury,NY 12804 Inspector's Ini i e rt ep 5q 0 NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y J N N/A COMMENTS raming Jack Studs/Headed Bracing/Bridging X Joist hangers Jack Posts/Main Beams V511 Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 3 6 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inche* s from wall Fire separation 1, 2,3 hour Fire wall.2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7.sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\FramingFirestopping Inspection Report.doo January 28,2003 .Framing 1 Firestopping Inspection Report Office No. (S 18)761-8256, Date Inspection request received: Queensbury Building&Code.Enforcement Arrive: , ann/ epart: T alnl m 742 Bay Road,Queensbury,NY 12804 .. Inspector's Initia s: l NAME: PERMIT#: 3-- ,- LOCATION:" INSPECT ON: 3 60 TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Jack Studs/Headers Bracing/'Bridging Joist hangers _ Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in. Notches I Holes I Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge 8) 16D nails each side, Draft stopping 1,000-sq.ft:I floor trusses Anchor s 6 ft,or less on center ce and snows 4 inches from wall Fire separation 1,2;3 hour Fire wall.2, 3,4 hour Firestopping Penetration sealed 16 inch insulation'in.cavity min. Garage Fire Separation .House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable.Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above./below grade 5.0 sf grade . L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: a 1 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:tpe�,: am/pm NAME: I PERMIT LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain Vents Cast Iron, Copper Drain/Vent Comm. Plumbing Vent Vents in Place Rou Plumbing/Nail Plates 3h H ad or Air Supply Test Dfain and Vents NV 5 PSI or 10 ft. above highest Connection for 15 minutes Ak: Water Supply Piping Copper Commercial Copper,CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check -Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly CONEVIENTS: �L-.\SucHemingway\Building.Codes.Inspection.FORMS\Rotigh Plumbing Insulation Report.doc January 28,2003 Foundation inspection Report Office No.(518)761-8256 Date Inspection request received: ' Queensbury Building&Code Enforcement Arrive: am/} rl Q Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: (D �G. NAME: 1-- t C t• PERMIT#: .- LOCATION: INSPECT ON: k TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 rpil poly for wet areas under slab Ba ill Approval bing Under Slab PV /Cast/Copper L ou dation Insulation Interior/E erior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\BuiIding.Codes.Inspection.FORMSIFoundation Inspection Report.doc January 28,2003 Framing I Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received, Queensbury Building&Code Enforcement Arrive: am/pt DCD* art:?�-,,,, Cain/pm 742 Bay Road,Queensbury,NY 112804 Inspector's Initials: V( L"V NAME: W (u-, PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N—':N/A Framing COMMENTS Jack Studs Headers Bracing Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 3 6 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8),16D nails each side Draft'stopping 1,000 sq. ft.floor trusses ,Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2-,3 hour Fire wall,2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space Bedrooms 24 in.(H) 20 in.(W) 5.7.sf above/below grade 5.0 sf grade L:\Sueliemingway\Building.Codes,Inspection,FORMSTraming Firestopping Inspection Report.doo January 28,2003 WC,-rv- Framing/Firestopping Inspection Report <-- P� 3 Office No. (518)761-8256 Date Inspection request received* Queensbury Building&Code Enforcement Arrive-—am/p art pm. 742 Bay Road, Queensbury,NY 1.2804 Inspector's Initials: j NAME: t _ ERM1T#: 3 LOCATION: INSPECT ON: Z TYPE OF STRUCTURE: Y N—'N/A COMMENTS Framing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 3 6 in. or more Headroom 6 ft. 8 in. Notches Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft, floor trusses z Anchor Bolts 6 ft.or less on center e an sno re me es a wall ,� /�, V--1 Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration scaled 16 inch insulation in cavity min. Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report-doe January 28,2003 Framing/Firestopping Inspection Report Office No. (5 18)761-825 6 Date Inspection request received* Queensbury Building&Code Enforcement Arrive: am/i p �Depart: 0 Ltmiprn 742 Bay Road,Queensbury,NY 12804 Inspector's Initials. NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N— N/A . COMMENTS Framing Jack Studs Headers Bracing Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses /Anchor Bolts 6 ft. or less on center Ice and snow-shield 24 inches from wall Fire separation 1,2,3 hour Fire wall,2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min, Garage Fire Separation House side Y2,inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7.sf above/below grade 5.0 sf grade L:4SueHemingway\Building.Codes.1 nspection.FORMSTraming Firestopping Inspection Report.doc January 28,2003 1Y JC-)Vkt,�i 0 -770 tAEC-x— �-`%A Framing Firestopping inspection Rdport Office No. (518)761-8256 Date Inspection reque �rt: d: JVIISIA4 grA ' S IQueensbury Building&Code Enforcement Arrive: a IT 742 Bay Road, Queensbury,NY 112804 Inspector's ll�fial . NAME: S PERMIT#: LOCATION: L INSPECT ON: TYPE OF STRUCTURE: Framing Y N COMMENTS 17 Jack Studs Headers A ;F-N> Bracing Bridging Joist hangers enk Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in: or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center -rc—ea-n-d-s-EFW�shield 24 inches from wall Fire separation 1,2,3 hour Fire wall,2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min, Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes,lnspection.FORMS\Frami7lgFirestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspectio reques cei d- Queensbury Building&Code Enforcement Arrive: arn/p a +pectio Ir I 742 Bay Road, Queensbury,NY 12804 Inspector's itial NAME: PERMIT#: INSPECT - LOCATION: ON: TYPE OF STRUCTURE: Framing Y N NIA CONMENTS Jack Studs/Headers. Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 3 6 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side 7 Draft stopping 1,000 sq. ft.floor trusses ,, Anc r Bolts 6 ft. or less on center ce and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour bl - Firestopping Penetration sealed 16 inch insulation in cavity-min. Garage Fire Separation House side V2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASuel-lerningway\Building.Codes,Inspection.FORNISTraming Firestopping Inspection Report.doo January 29,2003 Framing /Firestopping Inspection Report Office No.(518) 761-8256 Date Inspection reque received: - d Queensbury Building&Code Enforcement Arrive: am/ e art: m/pm 742 Bay Road,Queensbury,NY 1.2804 Inspector's Initials: { r NAME: PERMIT#: 0 � LOCATION: INSPECT ON: i r Uv TYPE OF STRUCTURE: C Framing Y N 'N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"Q.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate �--- 1 %2(w) 16.gauge(8) 16D nails each side Draft stopping 1,000 sq. ft, floor trusses Anchor Bolts 6 ft. or less on center ce and sn s ie d 24 inches from wa Fire separation 1, 2,3 hour Fire wall,2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%i inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing/Firestopping Inspection Report a.�� 3 Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: )epart: mlpm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: 1 � �l PERMIT#: LOCATION: - INSPECT ON: TYPE OF STRUCT, E: Framing Y N—'NIA COMMENTS Jack Studs/Headers Bracing/Bridging FP,PT- I A�-- Joist hangers — Jack Pasts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z(tv) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft,floor trusses Anch Its 6 ft. or less on center e and snow shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min, Garage Fire Separation House side %z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing 1 Firestopping Inspection Re ort Office No. (51$)761-8256 Date Inspection r uest Yece e _ Queensbury Building&Cade Enforcement ' Arrive: '� a a'pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: 'l,�g i PERMIT#: � LOCATION: "'� t���\ 1Q .� ,' INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Jack Studs/Headers Bracin /Bridging oist hangers DRVtU � Lo l PP?-j3\)EAD Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. 1 l Headroom 6 ft. 8 in. t �b�- o�-�.. 1u� Stairwells 3 6 in. or more DE P� Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping-for-Notches Top Plate 1 %2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft, floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour s Fire wall.2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %Z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade I,:\Suellemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report ,j 18)761-8256 Dke Inspection request received: -,;jasbury Building&Code Enforcement Arrive: am/RZt: , epart: -y,NY 12804 am/pm 742 Bay Rd., Queensbut Inspector's Initials: NAME: V,4 6-1., PERMIT#: (0 3- LOCATION: 1/?VcL6(rklll SPECT ON: TYPE OF STRUCTURE: <;P�l /7 41 V Comments Y/ N N/A ootings 'IV Piers Monolithic Slab Reinforcement in Place V The contractor is responsible or I providing protection from freezing f6r 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Danipproofing Foundation/Waterproofing Type of Danipproofmg/Waterproofing Footing Drain Daylight or Sump, Footing Drain Stone: 12 inch width 6 inches above footing ,6 mil of for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior Exterior R- Rough Grade 6 inch drop within 10 ft. LASucHerningway\Building.Codes.hispectionTORMSToundation Inspection Report doe January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection reques received: '�ein/pm Queensbury Building&Code Enforcement Arrive: am/p A j Depart: 742 Bay Rd., Queensbuly,NY 12804 Inspector's Initial.. 5-Vk-1— NAME: —PeLyl- PERMIT#: 5 LOCATION: INSPECT ON: TYPE OF STRUCTURE:�- K 247f Comments .__ Y N/A rpier -Idb�nolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Danipproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil of for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6inch drop within 10 ft. LASucHerningway\Building,Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (5 18)761-825 6 Date Inspe tion request received: Queensbury Building&Code Enforcement 1�164 am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: �4 ILA PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation-Dampproofing Foundation/Waterproofing Type of Darapproofing/Waterproofing Footing Drain Daylight or Sump, Footing Drain Stone. 12 inch width 6 inches above footing 6 mil of for wet areas unde Zslab Back fill Approval Plumbing Under Slab PVC/Cast./Copper Foundation Insulation Interior Exterior R- V/ Rough Grade 6 inch drop within 10 ft. L:\SucHemingway\Building.Codes.Inspection.FORMS\Foundafion inspection Report doc January 28,2003 Foundation Inspection Report Office No, (518)761-8256 Date Inspection reque ei Queensbury Building&Code Enforcement Arrive: a m Depart: 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial NAME: PE #: LOCATION: _gAC Y- LQ6.,eSPECT ON: TYPE OF STRUCTURE:' Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump.Footing Drain Stone: 12 inch width 6 in3kes above footing 6,Ail of for wet areas under slab Xckfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R-- Rough Grade 6 inch drop within 10 ft. L:\SucHeming<vay\Btiilding.Codes.Inspection.FORMS\Foundation inspection Reportdoc January 28,2003 Foundation Inspection Report Office.No. (S 18)761-8256 Date Ins ection rf el Queensbury Building&Code Enforcement Arrive: aDepart: a n 742 Bay Rd.,Queensbury,NY 12804 Inspector's InitialE n3=s g �NAME: Z �� �GU P LOCATION: INSPECT ON: — TYPE OF STRUCT . Comments Y N N/A ootings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofmg/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Suellemingway\Building.Codes.InspectionYORMSToundation Inspection Report,doc January 28,2003 03 Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release 1 Data filename:C:\Program Files\Check\REScheck\2369-03 WILLIAMS-8 BLACKBERRY LANE,QUEENSBURY.rck TITLE:PLAN NO.2369-03 COUNTY:Warren STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached I or 2 Family BEATING TYPE:Non-Electric DATE:07/30/03 DATE OF PLANS:FEBRUARY 14,2003 PROJECT INFORMATION: DANIEL&CHERYL WILLIAMS 8 BLACKBERRY LANE QUEENSBURY,NEW YORK 12804 COMPANY INFORMATION: WILLIAMS&WILLIAMS DESIGNERS 509 GLEN STREET GLENS FALLS,NEW YORK 12801 COMPLIANCE:Passes Maximum UA=710 Your Home UA=571 19.6%Better Than Code(UA) Gross Glazing Area or Cavity, Cont or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Cathedral Ceiling(no attic) 180 38.0 0.0 5 Ceiling 2:Flat Ceiling or Scissor Truss 2189 38.0 0.0 66 Wall 1:Wood Frame, 16"o.c. 2436 19.0 5.3 87 Window 1:Wood Frame:Double Pane with Low-E 327 0.280 92 Door 1:Glass 48 0.280 13 Door 2:Glass 48 0.280 13 Door 3:Glass 128 0.280 36 Door 4:Glass 48 0.280 13 Door 5:Glass 48 0.280 13 Door 6:Solid 21 0.130 3 Wall 2:Wood Frame, 16"o.c. 900 19.0 5.3 29 Window 2:Wood Frame:Double Pane with Low-E 64 0.280 18 Door 7:Glass 48 0.280 13 Door 8:Glass 48 0.280 13 Door 9:Glass 128 0.280 36 Door 10:Glass 21 0.130 3 Basement Wall 1:Solid Concrete or Masonry 998 13.0 10.0 40 Wall height: 10.0' Depth below grade:6.0' Insulation depth- 10.0' Basement Wall 2:Solid Concrete or Masonry 357 13.0 5.3 20 Wall height: I Off Depth below grade:3.0' Insulation depth: 10.0' Floor 1:Slab-On-Gradeffleated 85 10.0 58 Insulation depth:4.0' Boiler 1:Gas-Fired Steam,87 AFLJE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with't'his permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, ,,ey are att mg that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are.' om pli C wi ode. mil esi g Date- x ' REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release 1 DATE:07/30/03 TITLE:PLAN NO.2369-03 Bldg. Dept. Use I Ceilings: [ ] I 1. Ceiling 1: Cathedral Ceiling(no attic),R-38.0 cavity insulation Comments: [ ] I 2. Ceiling 2:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: I Above-Grade Walls: [ ] I 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity+R-5.3 continuous insulation Comments: [ ] I 2. Wall 2:Wood Frame, 16"o.c.,R-19.0 cavity+R-5.3 continuous insulation Comments: I Basement Walls: [ ] I 1. Basement Wall I: Solid Concrete or Masonry, 10.0'ht/6.0'bg/I OA'insul, R-13.0 cavity+R-10.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. [ ] I 2. Basement Wall 2:Solid Concrete or Masonry, 10.0'ht/3.0'bg/10.0'insul, I. R-13.0 cavity+R-5.3 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. I Windows: [ ] I 1. Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.280 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] I 2. Window 2:Wood Frame:Double Pane with Law-E,U-factor:0.280 For windows without labeled U-factors,describe'features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: I Doors: [ ] I 1. Door 1:Glass,U-factor:0.280 Comments: [ ] I 2. Door 2: Glass,U-factor:0.280 Comments: [ ] I 3. Door 3:Glass,U-factor:0.280 Comments: [ ] I 4. , Door 4: Glass,U-factor:0.280 Comments: [ ] I 5. Door 5:Glass,U-factor:0.280 Comments: 6. Door 6: Solid,U-factor:0.130 Comments: 7. Door 7:Glass,U-factor:0280 Comments: 8. Door 8:Glass,U-factor:0.280 Comments: 9. Door 9:Glass,U-factor:0.280 Comments: 10. Door'l 0:Glass,U-factor:0.130 Comments: Floors: I. Floor 1: Slab-On-Gradeffleated,4.0'insulation depth,R-10.0 continuous insulation Comments: Slab insulation to extend down from the top of the slab to at least 4.0 ft.OR down to at least the bottom of the slab then horizontally for a total distance of 4.0 ft. Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. Heating and Cooling Equipment: 1. Boiler 1:Gas-Fired Steam,87 AFUE or higher Make and Model Number Air Leakage: Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: Materials and equipment Must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed beating and cooling equipment and service water heating equipment must be provided. Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Supply ducts in unconditioned attics or outside the building must be insulated to R-11. Return ducts in unconditioned attics or outside the building must be insulated to R-6. Supply ducts in unconditioned spaces must be insulated to R-I 1. Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). Ducts shall be supported every 10 feet or in accordance with the manufacturers instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space j temperature set point of the largest zone. 1 Electric Systems: [ ] ( Separate electric meters are required for each dwelling unit. Fireplaces: . Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction j provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater,has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1, E Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. C Swimming Pools: [ ] ( All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. 'Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. i . Table I: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts ' Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts I"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 L5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)