2003-601 `SOWN OF %EENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518)761.8256
'CERTIFICATYOF COMPLIANCE
Pe="t Number: P20030601 Date Issued: Monday,November 03, 2003
This is to certify that work requested to be done as shown by Permit Number P20030601
has been completed.
Tax Map Number: 523400-308-014-0001.052.000-0000
Location: 183 PITCHER Rd
Owner: ARC4BFND,L.L.C.
Applicant: EDYTHE ALDRICH
This structure may be occupied as a:
By Order of Town Board
Deck TOWN OF QUEENSBURX
Director of Building&Cock Enforcement
4
TOWN OF QtTEENSBURY
742 Bay Road,Queensbury NY 12804-5902 (518)761-8201
Community Development Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: P20030601 Application Number: A20030601
Tax Map No: 523400-308-014-0001-052-000-0000
Pernussion is hereby granted to: F,DYTHF,ALDRICH
For property located at: 183 PITCHER Rd
in the Town of Queensbury,to construct or place
at the,above location in accordance with application together with plot plans and other information hereto filed
and Iapproved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type,of Constructioni Value
Owner Address: ARC4BFND, L.L.C.,
PROPERTY TAX DEPARTMENT Deck $5,000.00
Total Value $5;000.00
PO BOX 13244
EL PASO,TX 79913-3244
Contractor or Builder's Name/Address Electrical Inspection Agency
t 4 t
------------------
Plans&Specifications
2003-601 EDTHE ALDRICH 10 WOODLAND PATH
200 SQ FT DECK AS PER PLOT PLAN SPECIFICATIONS
$40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,August 13,2004
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queerisbury' .before the expiration date.)
Dated at the To 1 of ensb W n day,August,13,2003
SIGNED BY v for the Town of Queensbury.
Director of Building& ode E orcement
-Porch, Deck, •Dock, ,or-Boathouse Permit Application
Town of Queensbury—Dept of Community,Development,742 Bay Road, Queensbury,NY
(518)761-8256 • `•
A permit must be obtained before beginning construction. No Permit File No.0 3 —/ f
inspection will be made until applicant has received a valid Fee Paid $
building permit. All applicants' spaces on this application must be
completed and must appear on the application form Reviewed By.
A plican • 'p � ,� Owner:
Address: / t Address:
2- ti
Phone#( }7 - Phone# -
Email Address: Email Address:
Person Responsible for Supervision of Work as Regards to Building Codes:
Name ��C-� Address: j.Ee'�' G�r 'll' Phone .-2 `7
Property-Location: Lot Number: /;c;2 I House Number le• 7
�•i Tax Map Number:
Subdivision Name: 3G ;/41-1�S --
Estimated Market Value of Construction: $ r?)
@-''Porch
1'a Deck
❑ Dock
❑ Boathouse
❑ Other work(describe ainf/}?iz,,0
Size of structure to be built le7 k Z ; square feet
Submit along with this application: I
1. Two plot plans drawn to scale,preferably using a survey map:. Indicate pro, 0 2003
structure showing setback dimensions from all property-lines. Show 19 of
UE
water supply and location and configuration of septic disposal area. BU►�tV,4ivENSBbRY
�A�17 CODE i
2. Two sets of structural drawings.. Indicate size of posts or studs, floor joists,
decking or flooring material to be used. Show how the porch or deck will be
fastened to the building. If a roof will be constructed, indicate the size of posts or
studs,roof rafter spacing and span., Indicate type of roof: sloped,flat, shed, or
other. Indicate the type of material being used,for the roof.
Declaration: please sign below after you have carefully read the statement:
To the best of my knowledge the statements contained in this application,together with the plans and
specifications submitted,are a true and complete statement of all proposed work to be done on-the
described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws
pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is
authorized by the owner.
Date: AApplicant's signature:
L.1SueHemingway\Building.Permit.FORMS\Porch.Porch.Permit.doe 91/13/02 revised per DH
Residential Final Inspection `' `
Office No. (518) 761-8256 Date Inspection req t recei
Queensbury Building&Code Enforcement Arrive: m epart: t
742 Bay Rd., Queensbury,NY 12804 Inspector's Initi s:
NAME: �+ \ f 12 t A PE T ff: f
LOCATION: D TE:
TYPE OF STRUCTURE:
Comments
Y N NIA
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof
Roof Complete
Guard 30 in.or more @ stairs,decks,patios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in.or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
8 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft. or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
-Low water shut-off boiler
Relief Valve(s)installed
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing
Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: / Battery backup:
Bathroom Fans,if no window
Carbon Monoxide detector
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
3/4 hour fire door/door closer
Gara e fireproofing
Duct work Sealed properly
Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, 1 s .ft.-150 s . ft.vents
Building No./Address visible from road
Final Electrical .
Site Plan /Variance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept. Inspection Sticker
Flood Plain Certification,if required
Okay to issue C/C(Cert. Of Compliance)
Okay to issue Temporary C I O(Cert. Of Occii anc
Okay to issue Permanent C/O(Cert. Of Occupancy)
L:\SueHemingway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003
J
Residential Final Inspection
lkt
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: D M
P: AD�ID �
I`
742 Bay Rd., Queensbury,NY 12804 Inspector's Ini s
NAME: T#: 3- (9
LOCATION: ATE:
TYPE OF STRUCTURE:
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof
Roof Complete V.
Guard 30 in.or more @ stairs,decks,patios
Guard at stairwell at 34 in.or more I/A pl, 1jP]
lit
IV
Guard at deck,porches 36 in.or more
Exterior Finish Complete
Interior/Exterior Railings 34 in. to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
8 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft. or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water-shut'-off boiler
Relief Valve(s)installed
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing
Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Bathroom Fans,if no window
Carbon Monoxide detector
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
1/4hour fire door/door closer
Garage fireproofing
Duct work Sealed properly
Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, I sq.1-150 sq. ft,vents
Building No./Address visible from road
Final Electrical
Site Plan /Variance required-
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Flood Plain Certification,if required
Okay to issue C/C(Cert.Of Compliance)
Okay to issue Temporary C/0(Cert.Of Occupancy)
Okay to issue Permanent C/0(Cert.Of Occupancy)
L:\SueHemingway\Building.Codes.Inspection.17ORMS\Res.Final Insp.form 2.doe edited January 28,2003
0C)
Residential Final Inspection
Office No. (518)761-8256 Date Inspection re st rec ived:
Inspection
re st rec ivep
Queensbury Building&Code Enforcement Arrive* a��p art: P.M-.-
s
742 Bay Rd., Queefisbury,NY 12804 Inspector's ial
NAME: `r P IT#: o
LOCATION: 1 E: C;1�
k_z��
TYPE OF STRUCTUR-t: ;22
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof A
Roof Complete
Guard 30 in.or more @ stairs,decks,patios
Guard at stairwell at 34 in.or more
Guard at deck,porches 36 in.or more
Exterior Finish Complete
Interior/Exterior Raili in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
8 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
-Gas Fimiace shut-off within 30 ft. or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-*off boiler
—Relief Valves j installed
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing
Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: / Batter y backup:
Bathroom Fans,if no window
Carbon Monoxide detector
Plumbing fixtures
Foundation insulation
Floor tniss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
3/4hour fire door/door closer
Garage fireproofing
Duct work Sealed properly
Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Y
Crawl Spaces 18"x 24"access, I sq, ft,-150 sq. ft.vents
Building No./Address visible from road
Final Electrical
Site Plan Wariance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Flood Plain Certification,if required
Okay to issue C/C(Cert. Of Compliance)
Okay to issue Temgoraiy C/0(Cert. Of Occupancy)
Okay to issue Permanent C/0(Cert. Of Occupancy
L:\StieHen-dngNvay\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003
APp
t i
j t
! , �0603
ro
w I OF
NO�IG�f MOBILE oM�
ANCNd'R1NG N �
�RAME.15 RVQt1tRED PER - p;
NIANU�ACTURERS SPECIFSCA�IUNS
JUL 3 0 2003
AT
OQUEENSt3t1RV ,.
.. Q
rn �
Qi,PEEN SBURY BUILDING GEMRTMEHT Ica,O
n; d on our limited examinaWnt
ct,;nrpliance with our comrriems shall T IS PLAIN TO BE ON
,t tie construed as mdic*lg the
ar�ln �J ECT—SI-T AT
;c mianceryth the code.
ALL TIMES FOR
THE DURATION-OF
+ GNSTRUGT ON
TnWN car QUEHEENSBUR 1�
_<Z) BUILDING &
REVIEWED BY
t� DATE
a �
1
f
�� a��r... �rrz:w�w��iw�rriw�r:r,�l +�-.r,+ •
c�iC�;•7-r� y ate*., '+
I
rY