2003-620 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518)761-8256
CE RTIFICATE OF OCCUPANCY
Permit Number P20030620 Date Issued: Tuesday,February 10,2004
This is to certify that work requested to be-done as shown by Permit Number P20030620
has been completed.
Tax Map Number: 523400-296-008-000�1-027-00270000
Location: . 12 WAVERLY A
Owner: MCHAELS GROUP LLC THE
Applicant: MICHAELS GROUP LLC THE
This structure maybe occupied as a:
By Order of Town Board
Garage-2 Cars Attached . TOWN OF QUEENSBURY
Townhouse
Director of Building&Code Enforcement
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-'Building&Codes (518) 761-8256
i
BUILDING PERMIT
Permit Number: P20030620 Application Number: A20030610
Tax Map No: 523400-296-008-0001-027-002-0000 .
Permission is hereby granted to: MTCHAELS GROUP LLC THE
For property located.at: 12 WAVERLY PI
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: MICHAELS GROUP LLC THE
1.0 BLACKSMITH Dr Garage-2 Cars Attached
MALTA,NY 12020-0000 Total Value $1&9,9 0. 0
$189,900.00
Contractor or Builder's Name/Address Electrical Inspection Agency
MTCHAELS GROUP
10 BLACKSMITH Dr STE 1
MALTA.NY 12020
Plans&Specifications
A2003-620 LOT 53 HSE#12 WAVERLY PLACE
2097 SQ FT TOWNHOUSE WITH 2-CAR ATTACHED GARAGE AS PER PLOT PLAN
SPECIFICATIONS
$341.88 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,August 12,2004
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of Queensbury; Tuesday,August 12,2003
SIGNED B. for the Town of Queensbury.
for B ' Code.Enforcement
Building Permit Application
"Town of Queensbury—Dept of Community Development, 742 Bay Road, Queensbury,NY _
(518)76I-8256
A permit must be obtained before beginning construction. Permit File No.
No inspection will be made anti) applicant has received a 1'Ce Paid S �
valid building pernui. All applicants, spaces on this Rcc. FCC Paid
application must be completed and must appear on the Reviewed By N
application form. x_ `
Applicant:�IA`E 1"`i'� ae Owner: IF—
Address: 1� 12A -V 1r� 7f2o5.� Address:
Cal- N o1. i"2C-��zt_-�,
Phone#(15e) �3�__.0 Phone# ( _ } .. V
AUG 0 5 2003
Property Location: Lot Number: S3 / House Number � u`1r �13t� Y
Subdivision Name: �( y2�c-\ P Tax Map Number:
O AN!1 CQD_
New Building:" residence /conunercial Estimated Market Value of Construction:$
o Addition: residence/ conunercial If an Addition,what will use of new addition be? "
o Alteration: residence/ commercial
a No change to exterior size: residence/eoni'I
❑ Other work(describe )
Check occul), cylnformation I`t Floor 2"` Moor Other Iloor 'Total
Below sq.ft. sq. fl• sq.It. Square Feet
❑ _Single family dwelling
❑ Two family dwelling
Townhouse
o Multifamily dwelling
#of units
o Office
❑ Mercantile
❑ Manufacturin
❑ I car detached garage
0 2 car cletached garage
o 3 car cletached garage
o 1 car attached garage
2 car attached garage
0 3 car attached garage
❑ Storage building- --
commercial
o Storage building-
residettial
o Other
Will any second-hand or ungraded lumber be used? If so, for what?
Type of Heating System: electric/ oil /(2)wood /forced hot air l baseboard/other:
Number ofEirenlaces to be installed Number of Woorlstrares to be installed
List below the person(s) responsible for supervision of work as regards to building codes:_.,
Name Address Phone Number
Ptumbcr t`o. C_ �_1 ��nb ► C.,
Mason (�. `sac3 —
Electrician e _v__
DCclarattiiorl: please sign below aver you have carcCullylread [lie statement:
To the best of niy knowledge the statements contained in this application,together with the plans and specifications
submitted,are a it-tic and complete statement of all proposed work to be done on the described premises and that all
provisions of the 131tilditig Code, the Zoning Ordinance and all other-laws pertaining to the proposed work shall tic complied
with, whether specified or noted,and that sttch work is anlhorized by the owner. Further, it is understood that I/we shall
submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning
Administrator or Director of Building and Codes,an As Ilrrtll Sari ev by a licensed surveyor;drawn to scale,showing actual
location of all new construe LL.
signature: ��_ owner,owner's agent,architect,contractor
Residential Final Inspection
Office No. (518) 761-8256 Date Inspection requ7eAsreceived:
j j
Queensbury Building&Code Enforcement Arrive: am/ art: am/pm
742 Bay Rd., Queetsbury,NY 12804 Inspector's Initials:
NAME: 0, (11 mm KAn PERMIT#:
LOCATION: \1 INVII—ePI/I DATE:
TYPE OF STRUCTURE:
.Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof
Roof Complete
Guard 30 in.or more @ stairs,decks,patios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in.or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in,
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Grade away from foundation 6 in,with 10 ft.
Handrail Termination at Newell Post or Wall
8 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft. or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut--off boiler
Relief Valve(s)installed
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing
Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area: _
Inter Connected: / Batter ybackup:
Bathroom Fans,if no window
Carbon Monoxide detector
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
'/hour fire door/door closer
Garage fireproofing
Duct work Sealed properly
Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, 1 sq.ft.-150 sq. ft.vents
Building No./Addres visible/ d
Final Electrical .-z,4 6 101cf!g��a
Site Plan /Variance iequfrfd I
Final Survey Plot Plan
As Built Septic System/ wer WlSt.Inspection Sticker
Flood Plain Certification,ifrequired
Okay to issue C/C(Cert.Of Compliance)
Okay to issue Temporary C 0(Cert.Of Occupancy)
Okay to issue Permanent C 0(Cert.Of Occupancy)
L:\SueHeniingivay\Biiilding.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003
0 N 11 n c >
H H H > > > r k H IN H H H z 0 8 0 r x Z 0 )4 0
Z H Z Z Z Z > H H P H P P 0 q Cr 0 V q 0 C H CA 0 t H n
> > 0 0 0 H q q N rM M 0 M Z 0 H q M M X X CH M 1; m H
0 v V H H H N H x H P H W Z
r H
ro 0 0 0 0 u Z Z H Z H q
Z0HHH M M > q o o 0 0 0 0 0 0 z 0 N 0 2
rn a > r t ro t > 0 0 0 H 4 \ P 0 \ H(n z M
P Z IN t t 'I H P P N t H Z 0 > x 0 ro
N < w z
> m z z C n 0
H ro > C r z n H z UI H
H n > 0 0 I'll m > Ho
0 > P q r0c H x 1 zn c z m
0 z v N x 0 v 0 r0r rnH 9 p m
0 q n H N N ro rn C > x \ al C
P z H q z N M H H 10
nrx
H H H C m z
z r0
0 z H 2 HP
n z 0
I H (A U) Gl
'� H � � ��i ro �°zN�'0
z ^ H mo a �o
m H Un >010
CH
H 022
corm
0 H H 5 00010
m z w
to o OP
MAP REFERENCE:
WAVERLY PLACE 5UBDIV15ION
DATED AUGUST 24. 2000
LAST REVI5ED JANUARY 1q. 2001
BY VAN DU5EN + 5TEVE5
LAND 5URVEYOR5. LLC
� an D u s en
8c
Steve s
Land Surveyors
169 Haviland Road Queensbury, New York 128
(518) 792-8474 New York Lie. No. 50135
.UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY
MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A
VIOLATION OF SECTION 7209, SUB —DIVISION 2, OF THE
NEW YORK STATE EDUCATION LAW.-
'ONLY COPIES FROM THE ORIGINAL OP THIS SURVEY
MARKED WITH AN ORIGINAL OF THE LAND SURVEYORS
SEAL SHALL BE CONSIDERED TO BE VAUD TRUE COPIES."
"CERTIFICATIONS INDICATED HEREON SIGNIFY THAT
THIS SURVEY WAS PREPARED IN ACCORDANCE WITH THE
EXISTING CODE OF PRACTICE FOR LAND SURVEYORS ADOPTED
BY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL
LAND SURVEYORS. SAID CERTIFICATIONS SHALL RUN ONLY
TO THE PERSON FOR WHOM THE SURVEY IS PREPARED, AND
ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL
AGENCY AND LENDING INSTITUITION LISTED HEREON, AND
TO THE A5VGNEZ5 OF THE LENDING INSTITUTION.'
Map of a Survey made for
THE MICHAELS GROUP
Town of Queensbury, Warren County, New York
AS PER MAP J%Dr.--
NO. I DATE
•�� 1. g� Nt���s &
DESCRIPTION
RECEIVED
JAN 2 0 2004
TOWN OF QUEENSBURY
BUILDING AND CODE
ya-te1 JANUAKY Z), dUL
Scale 1"=30'
S-1
SHEET 1 OF 1
Michaels
DWG. NO. WAVERLY-53
Rough Plumbing / Insulation Inspection Report
Office No. (518)761-8256 Date Inspection request received: 91X 03
Queensbury Building&Code Enforcement Arrive: am/p epart. pIn
742 Bay Road, Queensbury,-NY 12804 Inspector's Initials:
r
NAME: l�� S �=�� -_' PERMIT #:
LOCATION: INSPECT ON: �9
TYPE OF STRUCTURE:
Y N N/A
PVC: R 1,R 2,R 3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 % inch min.Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents .
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
.� Coo er, CPVC,Pex One and Two-Family
sulatio Residential Check/Commercial Check
ro er Vent,Attic Vent
Duct/Hot Water Piping Insulation
If re wired unheated spaces
Combustion Air Supply for Furnace
Duct work sealed prop"/No duct tape
COMMENTS:
L.\SueHemingway\Building.Codes.Inspection.FORMSIRough Plumbing Insulation Report doc November 17,2003
Rough Plumbing Insulation Inspection Report
Office No. (518)761-8256 Date inspection request received:
Quecnsbury Building& Code Enforcement Arrive: am/p am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
Ij 6>h PERMIT #:NAME: -
LOCATION: 31 wPhrt-/1,- INSPECT ON:
TYPE OF STRUCTURE:
Y N. N/A
PVC: R-1,R-2,R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
I % inch min. Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents* '
5 PSI or 10 feet above highest R3C
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water SupplyPiping
Cooper Commercial
Cooper, CPVC,Pex One and Two-Family
25d`Insulation/Residential Check/Commercial Check
Proper,Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly No duct tape I -H
COMMENTS: D
C&I Fe-4 Co/I��tj
L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November l7,2003
Rough Plumbing Insulation Inspection Report
Office No. (518)761-8256 Date Inspection request received;
Queensbury Building&Code Enforcement Arrive: Dart: am/pm
742 Bay Road,Queensbury,NY 12804 Inspector's Initials:
NAME: P ERMIT#: 01
INSPECT ON: oa-
LOCATION: 4
TYPE OF STRUCTURE:
Y' N N/A
PVC: R-1,R-2,R-3,R-4 Drain Vents
Cast Iron,Copper 'Drain/Vent/Comm.
Plumbing Vent Vents in Place
Rough Plumbing/Nail Plates
Head or Air Supply Test
Dfain and Vents
5 PSI or 10 ft. above highest
,-,Connection for 15 minutes
7 W fer Supply Piping
copper Commercial
Copper,CPVC,Pex One &Two Family
Insulation/Residential Check/Commercial Check
-Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace A
.Duct Work Sealed Properly fz-c-- (r-5
COMMENTS:
-L:\SueIieminpN,ay\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003
Rough Plumbing / Insulat}on Inspection Report
Office No. (518) 761-8256 Date Inspection request r ceived:
Queensbury Building&Code Enforcement Arrive: am/p epart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: -M - �,. PERMIT #: n:
LOCATION: C, INSPECT ON: )5 -0
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2,R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plum -Vent/Vents in Place '
u Plumbin /Nail Plates
1 Y2 inch min. Drain Size
_ashin Machin,✓-Drain 2 inch min.
ffC ad®rAir ShpplyTest
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
Cooper, CPVC,Pex One and Two-Family
Insulation/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November I7,2003
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received: A�
Queensbury Building&Code Enforcement Arrive: am/p art: ` am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT#: >5
LOCATION: j2-- INSPECT ON:
TYPE OF STRUCTURE:
Y N NIA COMMENTS
-�Franng�-----'
7
Jacotuds I Headers
✓Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
I '12(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2,3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation ip cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 518 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.OA grade
L:\SueHeming�vay\Building.Codes.Inspection.FORMSTraming Firestopping Inspection Report.doc January 28,2003
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received: zz
Queensbury Building&Code Enforcement Arrive: am/p part: mlpm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: GAS PERMIT#: J�
LOCATION: cr-iQ INSPECT ON:
TYPE OF STRUC
Framing Y N N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in.or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %z(w) 1 au e(8) 16D nails each side
Draft st ping 1,000 sq. ft.floor trusses
Andior Bolts 6 ft.or less on center
---- .slceand`.snow shield-24 inches from wall
SFire separation 1,2,3 hour
Fire wall 2,•3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side '/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
pwo5.0 sf grade
Foundation Inspection Report
Office No. (518)761-8256 Date Inspection requ tt,,rece1veXd'
Queensbury Building&Code Enforcement Arrive: am/p -part: am/pm.
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:-,
WNAME: PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE: L2,
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
ooting Drain Daylight or Sump
Z;7
0 oo�i,ng 4677i, Renx- '
6 OqFm V/
2 inch width
6 incheove footing
'b f ting
�,a
_6_m_jj:.fi.oLy_for wet areas under slab
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\SucHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Reportdoc January 28,2003
Foundation Inspection Report
Office No. (518)761-8256 Date Inspection request received: C)11 JZ14 r
Queensbury Building&Code Enforcement Arrive: a dpart./ am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: All�/ Sl/4�t� PERMIT#: �03-6-oa6
LOCATION: /.;Z- L INSPECT ON: 3
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Da-nipproofing
Q�ion/Watcr-p"rodfiu�
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\SueHemingway\Building.Codes.Inspection.FORMS\roundafion Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No. (51-8)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Ar.hve: am/pm Depart: am/pm
742 Bay Rd,, Queensbury,NY 12804 Inspector's Initials:
NAME: kkk�rhAee,5 PERMIT#:
LOCATION: L-0—kt Lj_ INSPECT ON.
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in-Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofmg/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil of for wet areas Linder slab
BaclSill Approval 4P
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior Exterior
R-
Rough Grade 6 inch*op within 10 ft.
L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundadon Inspection Report,doc January 28,2003
Fcundation Inspection Report
Office No.(51-8)761-8256 Date Inspection request received: /0
Queensbury Building&Code Enforcement Arrive: a;nV Depart:
d1n1pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initial
- d 6-�
NAME: MdU4 PERMIT#:
LOCATION: /a INSPECT ON: 9/1601/10
TYPE OF STRUCTURE:
Comments
Y IN N/A
QFootings
Piers
Monolithic Slab
Reinforcement in�Place 7Z,—
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement 2
of the concrete.
Materials for this purpose on site,
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing;/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil of for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior[Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003
Foundation Inspection Report
0
Office No. (518)761-8256 Date Inspection reques ei cl: /,�
Queensbury Building&Code Enforcement Arrive: a M epart: 4- OamVpm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initi
NAME: ERMIT 11-
LOCATION: --z,-E�Tn--V-� C .� INSPECT ON:
TYPE OF STRUCTURE:`
Comments
Y N /N/A
Apootings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump.
Footing Drain Stone:
1.2 inch width
6 inches above footing
6 mil of for wet areas under slab
Backfill Approval
-Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\SueHemingway\Building.Codes.Inspectioii.FORMS\Foundation Inspection ReporLdoc January 28,2003
Project Name: s BP# c�)(b3--&�;WJ
Address: Igr
wilding Permit Submission
Stefan'&
Tuof-aaaaly dz d*
Checklist
All items below must be checked either yes,no:or not applicable prior to submission of any building
permit to the Town of Queensbury Building Department. If any of the below items are lacking,the.permit
will not be accepted until such time as the application is deemed complete for submission.
1. Building Permit Application C onTletW ......................... ... ......... N;� .[]-no ❑n/a
2. Energy Form or CheckMate Energy Code Compliance Forms Gomplete:. -B-59-❑no ❑n/a
3. Energy Code Inspector's Report from CheckMate Program.. ... ...... ..: ❑no ❑n/a
4. Septic application completely filled out(i£applicable)...... .... ............. .:. Q yes ❑no nla
5. Solid Fuel Burning or Gas.Appliance Form:........................ ..:.:..:. ... Qyes Ono
6. Electrical Inspection Form.......... :... ... ......... ................... ...... ...... Clno ❑n/a
7. Two(2) complete sets of structural drawings....:.:.... ... .,. . ... ............ .05�s. ❑no ❑n/a
a)floor plan;b)foundation plan;-c)cross sections:d)elevations;
e)window and door schedule
8. . Two(2)site plans showing.locat on of the structure to be built,........... _ -E5s Ono ❑n/a
location of well or water lines,location of septic system or sewer lini :
9. Setbacks from property lines to new structure............ ..... ....... ..: .. . []no - ❑n/a
10, Setbacks to neighboring wells and septic systems,including onsite well.... _Qy6 nno []n/a
and septic systems(if applicable)
11. DiivewayPermit............... ... ......... ......................... ........... :...... yes Ono ❑n/a
Date: b�
Staf£Initial:
L:\SueHerdmgway\BuildingTenr it.FORMS\Generic Ched&t.doc
.Y
Permit Number
REScheck Compliance Certificate Checked By/Date
New York State Energy Conservation Construction Code. .,.
REScheckSoftware Version 3.5 Release lc
Data filename:F:\SHARE\Design\Energy`Cale\WAVE,RLY PLACE\12 Rosemary.cck
TITLE:WP 323 Rosemary V E
. ..COUNTY:Warren AUG p 5 2003
STATE:New York TOWN OF QUEENSSURY
HDD:7635 SUlt DING AND GQD"E
CONSTRUCTION TYPE:Detached I or 2 Family
HEATING TYPE:Non-Electric
DATE:08/01/03
DATE OF PLANS:July 30,2003
PROJECT INFORMATION:
I2Waverly Place:
Queensbury,NY 12804
COMPANY INFORMATION:
The Michaels Grop
10 Blacksmith Dr.
Malta,NY 12020
NOTES:
Silverline 2900 windows Standard Rosemary
All options included
COMPLIANCE:Passes
Maximum UA=485
Your Home UA=437
99%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont, or"Door
Perimeter R Value R-Value U-Factor UA
FIoor over garage:
All-Wood Joist/Truss,Over Unconditioned Space 105 19.0 0.0 5
Ceiling 1:Raised or Energy Truss 1604 30.0 0.0 51
Mbr.opt.bay ceiling:Raised or Energy Truss 30 30.0 0.0' 1
Mbr.opt.bay wall:Wood Frame, 16"o.c. 15 19.0 0.0 1
Brkfst,opt.box ceiling:Raised or Energy Truss 25 30.0 0.0 I
Brkfst. opt.box wail:Wood Frame, 16"o.c. 36 19.0 0.0 2
Ist fl walls:Wood Frame, 16"o.c. 1761 19.0 6.0 91
Brkfst#7: Glass 40 0.350 14
Ix Mbr(A):Vinyl Frame,Double Pane with Low-E 34 "0.400 14
2x opt.Mbr(K):Vinyl Frame,Double Pane with Law-E 21 0.400 8
Ix Study(P):Vinyl Frame,Double Pane with Low-E 17 0.400 7
Garage#20: Solid 19 0.240 5
Entry#113: Solid 37 0.350 13
Ix Dining(L):Vinyl Frame,Double Pane with Low-E 30 *0.400 12
2x Family(D): Vinyl Frame,Double Pane with Low--E 27 0.400 11
I x Family(E):Vinyl Frame,Double Pane with Low-E 27 0.400 11
2nd fl.walls:Wood Frame, 16"o.c. 711 19.0 0.0 41
lx Foyer(U):Vinyl Frame,Double Pane with Low-E 14 0.400 6
Ix Bath(Z):Vinyl Frame,Double Pane with Low-E 4 0.400 2
Ix Bonus(P):Vinyl Frame,Double Pane with Low-E 17 0.400 7
.opt.Bed#4 wall: Wood Frame, 16"o.c. 251 19.0 0.0 13
Ix opt.Bed#4(AR):Vinyl Frame,Double Pane with Low-E 32 0.400 13
opt.ceiling Bed#4:Flat Ceiling or Scissor Truss 167 30.0 0.0 6
opt.Bed#4 floor over garage: -
All-Wood Joist/Truss,Over Unconditioned Space 167 19.0 0.0 8
Basement Wall 1: Solid Concrete or Masonry 1294 0.0 11.0 83
Wall height:7.6'
Depth below grade:6.6'
Insulation depth:6.0'
3x Standard Bsmnt windows:
Wood Frame,Double Pane with Low-E 12 0.526 6
Bsmnt wall opt.Brk&: Solid Concrete or Masonry 31 0.0 11.0 2
Wall height:7.6'
Depth below grade:6.6'
Insulation depth:6.0'
Bsmnt wall opt.Fireplace:Solid Concrete or Masonry 31 0.0 11.0 2
Wall height: 7.6'
Depth below grade: 6.6'
Insulation depth:6.0'
Bsmnt wall opt.Mbr: Solid Concrete or Masonry 13 0.0 11.0 1
Wall height: 7.6'
Depth below grade: 6.6'
Insulation depth:6.0'
Furnace 1:Forced Hot Air, 80 AFUE
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,
specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the
New York State Energy Conservation Construction Code requirements. When a-Registered Design Professional has stamped and
signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or
specifications are in compliance witk this Code.
Builder/Designer__ Date
r REScheek Inspection.Checklist
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release 1c
DATE: 08/01/03
TITLE:WP 323 Rosemary
Bldg.
Dept.
Use
Ceilings:
[ } L Ceiling 1:Raised or Energy Truss,R-30.0-cavity insulation
Comments:
Insulation must achieve full height over the plate lines of exterior walls.
[ } 2. Mbr.opt.bay ceiling:Raised or Energy Truss,R-30.0 cavity insulation
Comments:
Insulation must achieve full height over the plate lines of exterior walls.
[ ] 3. Brkfst.opt.box ceiling:Raised or Energy Truss,R-30.0 cavity insulation
Comments:
Insulation must achieve full height over the plate lines of exterior walls.
[ } 4. opt.ceiling Bed 44:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation
Comments:
Above-Grade Walls:
[ ] 1. Mbr.opt.bay wall: Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
[ } 2. Brkfst. opt.box wall:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
[ } 3. 1st fl walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
[ ] 4. 2nd fl.walls:Wood Frame, 16"o.c.,R 19.0 cavity insulation
Comments:
[ ] 5. opt.Bed#4 wall:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
Basement Walls:
[ ] I. Basement Wall 1: Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insul,
R-11.0 continuous insulation
Comments:
Exterior insulation must have a rigid,opaque,weather-resistant protective covering that
covers the exposed(above-grade) insulation and extends at least 6 in.below grade.
[ } 2. Bsmnt wall opt.Brkfst: Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insul,
R-11.0 continuous insulation
Comments:
Exterior insulation must have a rigid,opaque,weather-resistant protective covering that
covers the exposed(above-grade)insulation and extends at least 6 in.below grade.
[ ] 3. Bsmnt wall opt.Fireplace: Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insul,
R-11.0 continuous insulation
Comments:
Exterior insulation must have a rigid,opaque,weather-resistant protective covering that
covers the exposed(above-grade) insulation and extends at least 6 in,below grade.
[ ] 4. Bsmnt wall opt.Mbr: Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insul,
R-11.0 continuous insulation
Comments:
Exterior insulation must have a rigid,opaque,weather-resistant protective covering that
covers the exposed(above-grade) insulation and extends at least 6 in.below grade.
r
Windows:
[ ] I. lk Mbr(A):Vinyl Frame,Double Pane with-Low-E,U-factor:0.400
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? [ J Yes [ ]No
Comments:
[ ] 2. 2x opt.Mbr(K):Vinyl Frame,Double Pane with Low-E,U-factor: 0.400
For windows without Iabeled U-factors,describe features:
#Panes Frame Type Thermal Break? [ ]Yes [ ]No
Comments:
[ ] 3. Ix Study(P):Vinyl Frame,Double Pane with Law-E,U-factor:0.400
For windows without labeled U-factors,describe features:
#Panes - Frame Type Thermal Break? [ J Yes[ ]No
Comments:
[ ] 4. Ix Dining(L):Vinyl Frame,Double Pane with Low-E,U-factor:0.400
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? [ ]Yes j ]No
Comments:
[ ] 5. 2x Family(D):Vinyl Frame,Double Pane with Low-E,U-factor:0.400
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? [ J Yes [ ]No
Comments:
[ J 6. Ix Family(E):Vinyl Frame,Double Pane with Law-E,U-factor:0.400
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? [ ]Yes [ ]No
Comments:
[ ] 7. lx Foyer(U):Vinyl Frame,Double Pane with Low-E,U-factor:0.400
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
[ ] 8. Ix Bath(Z):Vinyl Frame,Double Pane with Low-E,U-factor: 0.400
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?j ]Yes [ J No
Comments:
[ J 9. Ix Bonus(P):Vinyl Frame,Double Pane with Low-E,U-factor:0.400
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
[ 10. lx opt.Bed#4(AR):Vinyl Frame,Double Pane with Low-E,U-factor:0.400
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
[ ] 11. 3x Standard Bsmnt windows: Wood Frame,Double Pane with Low-E,U-factor: 0.520
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?j ]Yes j ]No
Comments:
Doors:
[ ] I. Brkfst#7: Glass,U-factor: 0.350
Comments:
[ ] 2. Garage#20: Solid,U-factor: 0.240
Comments:
[ J 3. Entry#113: Solid,U-factor:0.350
Comments:
Floors:
[ ] 1. Floor over garage:All-Wood Joist/Truss,Over Unconditioned Space,
R-19.0 cavity insulation.
Comments:
2. opt.Bed#4 floor over garage:All-Wood Joist/Truss, Over Unconditioned Space,
R-19.0 cavity insulation
Comments:
Heating and Cooling Equipment:
1. Furnace 1:Forced Hot Air, 80 AFUE or higher.
Make and Model Number
Air Leakage:
Joints,penetrations,and all other such openings in the building envelope that are sources of air
leakage must be sealed.'
Recessed lights must be 1)Type IC rated,or 2)installed inside an'appropriate air-tight assembly
with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a
3"clearance from insulation.
Vapor Retarder:
Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
Supply ducts in unconditioned attics or outside the building' must be insulated to R-11.
Return ducts in unconditioned attics or outside the building must be insulated to R-6.
Supply ducts in unconditioned spaces must be insulated to R-11.
Return ducts in unconditioned spaces(except basements)must be insulated to R-2.
Insulation is not required on return ducts in basements.
Duct Construction:
I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
(adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in.w.g.(500 Pa).
Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
Cooling ducts with exterior insulation must be covered with a vapor retarder.
Air filters are required in the return air system.
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
-Electric Systems:
Separate electric meters are required for each dwelling unit.
Fireplaces:
Fireplaces must be installed with tight fitting non-combustible fireplace doors.
Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
provisions of the Building Code offew York State ,the Residential Code of York State or
the New York City Building Code ,as applicable.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap'on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 105 or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
i
Table l: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 TO
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2"Runouts I"and Less 1.25"to 2" 2.511 to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 - 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD (Building Department Use Only)
r
s 0
Check Residential Plan Review: One &Two Family Dwellings
Y/N/N/A
(2)Full sets of plans
l Over 1,500 sq. ft.—Stamped
f Design Loads On Plans: 90 Wind Floor Loads 40 psf
e/ 70 Ground Snow Load Sleeping Areas and Attics 30 psf
Calculations:
Window Schedule With Glass Size
Door Schedule/Main Entrance 36"Door
mergency Escape Or Bedrooms and Habitable Space
Above/Below grade,5.7 sq.ft.
Grade,5.0 sq.ft.
24"(h)x 20"(w)min.
/ 44"Max.Height above floor
Residential Check Paperwork Compliance and Inspectors Checklist: OK
Dampproofmg/Waterproofing Materials On Plans
Foundation Drainage On Plans,if required
f 6"Drop in 10' Exterior Grade
Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where
Required
Ice and Snow shield 24"Inside Exterior Wall!24"Inside Knee Walls
Platforms At Exterior Doors .
Stairway Headroom 6' 8'All Stairs 36"Width
Stair Run and Rise
•
Winder Run and Rise
Spiral Not Allowed From 2"d Story
Smoke Detectors Battery Backup and Proper Location
Bathroom Fixtures Proper Clearance
Hall Width,36"min.
Handrails More Than One Riser On Open Sides
Railing and Guards>30"/Basement Stairs Included I Closed Risers More Than 4"in Ht.
Safety Glazing Notes For Required Areas
Garage Fire Separation
Garage Floor Sloped
Attic Access
Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access
Carbon Monoxide Detector Lowest Sleeping Level
Soil Test Results,if required
Septic To Well Or Water Line Separation
All Paperwork Signed
s, �V Town of Queensbury 742 Bay Road, Queensbury,NY 12804
Building & Code Enforcement Building Permit#
phone:(518)761-8256 Date:
Fax: (518)745-4437
Fwa- vod ue=bwy net
3
Dear
Yourbvikling permit qphcation has been reviewed and found to W deficient in the following ate
These details need io be added to or notedon both sets ofplans. Please feet free to contact this offim with aoy questions
regarding ibis matter.
Sincerely,
BUILDING&CODES OFFICE
L'lSnetiemingrray\ButkiinS Pe�nitFORMSjdc�icient bussldiAg pemnt-h-24D3-