CC-0889-2021 Office Use Only fil ADDITION/ALTERATION PERMIT Permit#: �,� 0M, 2-02'1 �-�_ APPLICATION Permit Fee:$ 1253•�� Town of Queensbwy 742 Bay Road,Queensbury,NY 12804 Invoice#: P:518-761-8256 www.aueensbury.net Flood Zone? Y eviewed B Project Location: 1415 State Route 9 S ace Tax Map ID #: 2$$. — �_�j3 Subdivision Name: Lake George Outlets PROJECT INFORMATION: `�AQ.1 TYPE: Residential X Commercial, Proposed Use: \ �C­60"N _Single-Family _Two-Family _Multi-Family (#of units ) _Townhouse _Business Office X Retail _Industrial/Warehouse _Garage (#of cars_) Other(describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 2nd floor: 2nd floor: 3rd floor: 3rd floor: Basement (habitable space): Basement (habitable space): Total sq ft: _ Total sq ft: ., Scope of work to be done: SOW:Total Space=3,000 SF with tenant fitout including demo,MEP's,and storefront work. D ,E C E 0 W DEC 21 2021 TOWN OF QUEENSBURY BUILDING&CODES Addition/Alteration Application Revised January 2021 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ $279,502 2. ,Source of Heat (circle one): x Gas _Oil _Propane _Solar_Other Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? YES X NO Explain: Just Interior Remodel 4. Are there any easements on the property? YES X NO SITE INFORMATION: • Is this a corner lot? _YES X NO • Will the grade be changed as a result of the construction? YES X NO • What is the water source? X PUBLIC _PRIVATE WELL • What type of wastewater system is on the parcel? X SEWER _PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read andagree to the above: PRINT NAME: Kelly Jamison SIGNATURE: DATE: 12-20-21 Addition/Alteration Application - Revised January 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Kelly Jamison Mailing Address, C/S/Z: 4721 Crest Knoll Drive Mableton GA 30129 Cell Phone: GOB 08 ) 4825900 Land Line: Email: Kellygnationwidepermit.com Primary Owner(s): Name(s): American Eagle Outfitters Mailing Address, C/S/Z: 77 Hot Metal St Pittsburgh PA 15203 Cell Phone: GOB O8 ) 42131117 Land Line: Email: Kellygnationwidepermit.com ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: Land Line: �) Email: **Workers' Comp documentation must be submitted with this application** • Arch itect(s)/Engi nee r(s): Business Name: Cortland Morgan Contact Name(s): Cortland Morgan Mailing Address, C/S/Z: 711 North Fielderer Rd Arlington TX 7GO12 Cell Phone: 8( 17 ) 63556913 Land Line: Email: w - c k 24- Contact Person for Compliance in regards to this project: Kelly Jamison or Contractor when TH Cell Phone: E( 08 ) 4825900 Land Line: Email: Kelly1nationwidenermit.com Addition/Alteration Application Revised January 2021 WNA Engineering, Inc. 12575T Perry Highway,Suite 100 Portersvi -� v lle,PA 16051 I L E 1� 724.368.8133 WAiVA 800 Vinial Street,Suite Al00 ENGINEER 1 N G Pittsburgh,PA 15212 412.208.1372 2/3/2022 D C E o V E FEB 10 2022 Town of Queensbury,Queensbury, NY TOWN OF BUILDING Fire Marshal's Office & CODES RE: American Eagle Outfitters Aerie#3875 The Outlets at Lake George,Space 115 Application#: N/A To Whom It May Concern: Please accept this letter as documentation of code compliance for issuance of a building permit. We feel these adjustments will meet your requirements. These changes will also be reflected on the"for construction drawings" located on site during construction. All comments have been clouded and marked with a Delta 1: • Verify�fire extinguisher location and inspection See FP.0.100. Location of exit/Emergency lighting appear adequate. Function test will be required Noted . . .Verify clearances to electrical service panels 3' clearance is confirmed • CO detection is required, if source is present Noted Pittsburgh, PA wnaengineering.com Portersville, PA WNA Engineering, Inc. • NFPA 72 letter of compliance required for any alterations-to the fire alarm system. Adding of appliances will require a floor plan to be submitted See E.0.500 • NFPA 13 letter of compliance required for any modifications to the sprinkler system See FP.0.100 • Contractor to exercise caution and provide protection for all fire alarm and sprinkler devices, during construction Noted • HVAC shutdown required if any units are =/<than 2000cfm Noted • Exterior emergency lighting is not found on the drawings See E.0.100 Regards, Justin Vernam OF NE r � W 09550S Rossto�P� Pittsburgh, PA wnaengineering.com Portersville, PA t F' u U Shapel V2 1 FED 1 p Y Sha el General Contracting, Inc. QVE�N�g r� P 9 20 East Main Street, Suite A Carnegie, PA 15106 2/3/2022 Jenn Ritter American Eagle Outfitters, Inc. 77 Hot Metal Street Pittsburgh,PA 15203 RE: Air Balance Company Aerie#3875 The Outlets at Lake George Hi Jenn, This letter serves to inform American Eagle that we be using MJL Adtek Enterprises, LLC for the air balancing at the Aerie#3875 The Outlets at Lake George job. If you have questions, please contact me at 412-522-8347 Sincerely, Shane Franklin President Shapel General Contracting,Inc. 412-522-8347 shane@shapelgc.com 11 o T LAN i ERE 1P Cfi N O C A N ARCH IT CT 711 N.Fielder Road o Arlington,TX 76012 o T: 817.635.5696 F: 817.635.5699 D 2/7/2022 FEB 10 2022 Town of Queensbury. , Queensbury,NY OF QUEENSgURY Fire Marshal's Office TOBU�j�DiNG&CODES Re: American Eagle Outfitters Aerie#3875 The Outlets at Lake George, Space 115 Application#:N/A To Whom It May Concern: Please accept this letter as documentation of code compliance for issuance of a building permit. We feel these adjustments will meet your requirements. These changes will also be reflected on the"for construction drawings"located on site during construction. All comments have been clouded and marked with a Delta 1: • Lock/ latches shall comply with Chapter 10 of 2020 IFC. See A.2.730 Verify paths of egress See A.0.106 • Verify storage See A.2.601R F.2.400 • Knox Box key is required Noted o Provide specifications for material listed as drapery hiformation requested • The exit from the stockroom does not appear compliant with IFC Section 1016.2 (5) (2) as no provisions are listed to comply with item 2.4 See A.0.106 • Truss ID signage required Information requested Please contact my office if you need additional information. Sincerely, RED Ape Cortland Morgan,AIA ���®��UNH® &0 .�2476% b OF N�` COMlcheck Software Version 4.1.5.3 [FILE=COPY Mechanical Compliance Certificate I,EE W/4s Project Information AN O Energy Code: 2020 NYStretch Energy Code-2018 IECC Project Title: Aerie 3875 r' Location: Lake George, New York Climate Zone: 6a Project Type: Alteration 095503 ' R�FESSIO�P� Construction Site: Owner/Agent: Designer/Contractor: The Outlets at Lake George American Eagle Outfitters,INC Wilson&Associates Engineering Lake George, NY 77 Hot Metal Street DPC Pittsburgh,PA 15203 1257 Perry Highway,Suite 201 412-432-3300 Portersiville, PA 16051 Mechanical Systems List Quantity System Type&Description frMk l�1 1 HVAC System 1 (Single Zone): Heating:1 each-Unit Heater,Electric,Capacity=26 kBtu/h No minimum efficiency requirement applies FEB q 1 0 202 Fan System: None 1 HVAC System 2(Single Zone): TOWN OF QUEENSPURY Heating:1 each-Duct Furnace,Electric,Capacity=34 kBtu/h BUILDING & CODl_=S No minimum efficiency requirement applies Fan System: None 1 HVAC System 3(Single Zone): Heating:1 each-Duct Furnace,Electric,Capacity=34 kBtu/h No minimum efficiency requirement applies Fan System: None 1 HVAC System 4(Single Zone): Heating:1 each-Unit Heater,Electric,Capacity=47 kBtu/h No minimum efficiency requirement applies Fan System: None 1 Water Heater 1: Electric Storage Water Heater,Capacity:6 gallons Proposed Efficiency:4.80 SL,%/h(if>12 kW),Required Efficiency:4.80 SL,%1h(if>12 kW) Mechanical Compliance Statement Compliance Statement. The proposed mechanical alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2020 NYStretch Energy Code-2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspectio^rk—LA1 * Brent Wiley - Mechanical Designer 2-3-22 Name-Title Signaturc Date Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc. Page 1 of 12 COMcheck Software Version 4.1.5.3 Inspection Checklist Energy Code: 2020 NYStretch Energy Code - 2018 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented,or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan.Review Complies? Comments/Assumptions & Re :ID C103.2 Plans,specifications, and/or Z❑Complies [PR2]1 ;calculations provide all information ;❑Does Not with which compliance can be ; :d etermined for the mechanical ;❑Not Observable ;systems and equipment and ,❑Not Applicable ;document where exceptions to the ; standard are claimed. Load !calculations per acceptable ;engineering standards and ; ,handbooks. C103.2 ;Plans,specifications,and/or ;❑Complies [PR3]1 :calculations provide all information !❑Does Not with which compliance can be determined for the service water UNot Observable heating systems and equipment and ❑Not Applicable ; ;document where exceptions to the ; ;standard are claimed. Hot water ; ;system sized per manufacturer's ;sizing guide. ; ; C405.11. ;New parking garages and new parking DComplies [PR38]3 ;lots powered by the energy services :❑Does Not for a building, and with 10 or greater ' 'parking spaces, provide either: 1. ❑Not Observable Panel capacity and conduit for the ;[]Not Applicable ; ;future installation of minimum 208/240V 40-amp outlets for 5 percent of the total parking spaces and not less than two parking spaces; :or 2. Minimum 208/240V 40-amp outlets for 5 percent of the total p. :parking spaces and not less than two ; ;parking spaces. Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3' Low impact(Ter Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 2 of 12 Section # Footing/Foundation Inspection Complies? Comments/Assumptions &.Re' .ID C403.12.2';Snow/ice melting system and freeze ;❑Complies protection systems have sensors and ❑Does Not C403.12.3;controls configured to limit service for ;❑Not Observable [FO9j3 (pavement temperature and outdoor ;❑Not Applicable temperature.future connection to controls. Additional Comments/Assumptions: 11 High Impact(Tier 1) '2 Medium Impact(Tier 2) 1','.3-.1 Low Impact(Tier 3) Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 3 of 12 Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions &Re .ID ,C404.5, ;,Heated water supply piping conforms ;❑Complies C404.5.1, :to pipe length and volume ;❑Does Not C404.5.2 ;,requirements,Refer to section details. ;❑Not Observable [PL6]3 ;❑Not Applicable C404.5; ;Heated water supply piping conforms ;❑Complies C404.5.1, ;to pipe length and volume T❑Does Not C404.5.2 ;requirements.Refer to section details. ;❑Not Observable [PL6j3 ;❑Not Applicable ; C404.5, ;Heated water supply piping conforms ;[]Complies C404:5.1, ;to pipe length and volume ;❑Does Not C404.5:2 ;requirements.Refer to section details. ;❑Not Observable [PL6]3 ;❑Not Applicable C404.5, ;Heated water supply piping conforms ;❑Complies C404.5.1, to pipe length and volume ;❑Does Not C404.5.2 ;requirements.Refer to section details. ;❑Not Observable [PL6]3 ;❑Not Applicable C404.5, ;,Heated water supply piping conforms ;❑Complies C404.5.1, :to pipe length and volume ;❑Does Not C404.5.2 ;requirements.Refer to section details. ;❑Not Observable; [PL6]3 ;❑Not Applicable C404.6.3 Pumps that circulate water between a ;❑Complies [PL7]3 :heater and storage tank have controls :❑Does Not ;that limit operation from startup to <=5 minutes after end of heating ;❑Not Observable cycle. ;❑Not Applicable ; C404.6.3',Pumps that circulate water between a ;❑Complies [PL7]3 heater and storage tank have controls 1,❑Does Not that limit operation from startup to <=5 minutes after end of heating ;[]Not Observable cycle. ;❑Not Applicable ; C404.6.3, ;Pumps that circulate water between a ;❑Complies [PL7]3` ;heater and storage tank have controls :,❑Does Not ;that limit operation from startup to <=5 minutes after end of heating ❑Not Observable cycle. ,❑Not Applicable , C404.6.3 i Pumps that circulate.water between a ;❑Complies ;[PL7]3 heater and storage tank have controls �,❑Does Not ;that limit operation from startup to <=5 minutes after end of heating ;❑Not Observable cycle. ;❑Not Applicable C404.6.3 ;Pumps that circulate water between a ;❑Complies '[PL7j3 heater and storage tank have controls :❑Does Not ;that limit operation from startup to ; <=5 minutes after end of heating ;❑Not Observable cycle. ;❑Not Applicable ; C404.7 ;Demand recirculation water systems ;❑Complies [PL8]3 ;have controls that start the pump ;❑Does Not upon receiving a signal from the ;action of a user of a fixture or ;❑Not Observable ;appliance and limits the temperature ❑Not Applicable ; ;of the water entering the cold-water j ;piping to 104°F. 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2). 1 '3.1 Low Impact(Tier 3) Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 4 of 12 Section # Plumbing Rough-in inspection Complies? Comments/Assumptions &Re .ID C40.4.7' ;Demand recirculation water systems ;❑Complies ; [PL8]3 ;have controls that start the pump ;❑Does Not ;upon receiving a signal from the ;action of a user of a fixture or UNot Observable ;appliance and limits the temperature ❑Not Applicable ;of the water entering the cold-water !piping to 104°F. C404.7 ;Demand recirculation water systems ;❑Complies (PLS]3 :have controls that start the pump ;❑Does Not upon receiving a signal from the ;action of a user of a fixture or ❑Not Observable :appliance and limits the temperature :❑Not Applicable ;of the water entering the cold-water !piping to 1047. C404.7 ;Demand recirculation water systems !❑Complies ; [PL8]3 have controls that start the pump ;❑Does Not ;upon receiving a signal from the action of a user of a fixture or ❑Not Observable appliance and limits the temperature :❑Not Applicable !.of the water entering the cold-water ; piping to 1047. C404.7 !Demand recirculation water systems ;❑Complies [PL8]3 !have controls that start the pump ;❑Does Not upon receiving a signal from the ; ;action of a user of a fixture or ;❑Not Observable appliance and limits the temperature []Not Applicable :of the water entering the cold-water ; ;piping to 104°F. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) .°3' Low impact(Teri) Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875,cc Page 5 of 12 Section # Mechanical Rough-in Inspection Complies? Comments/Assumptions &Re .ID C402.2.6 ;Thermally ineffective panel surfaces of;❑Complies [ME41]3 sensible heating panels have UDoes Not insulation >=R-3.5. ;❑Not Observable ❑Not Applicable C40311.3;HVAC piping insulation insulated in ;❑Complies [ME61]2 accordance with Table C403.11.3. ;❑Does Not Insulation exposed to weather is ;protected from damage and is :❑Not Observable provided with shielding from solar !❑Not Applicable radiation. ; ; C403.11.3 j HVAC piping insulation insulated in ;❑Complies ; [ME61]z f accordance with Table C403.11.3. :❑Does Not ;Insulation exposed to weather is protected from damage and is :❑Not Observable provided with shielding from solar �❑Not Applicable radiation. C403.8.1 ;HVAC fan systems at design ;❑Complies ;See the Mechanical Systems list for values. [ME65]3 ;conditions do not exceed allowable :❑Does Not ;fan system motor nameplate hp or fan; ;system bhp. UNot Observable ;❑Not Applicable CG403.8.1 ;HVAC fan systems at design ;❑Complies ;See the Mechanical Systems list for values. [ME6513 conditions do not exceed allowable QDoes Not ; ;fan system motor nameplate hp or fan; 'system bhp. :❑Not Observable; ;❑Not Applicable C403.8.1 ;HVAC fan systems at design ;❑Complies ;See the Mechanical systems list for values. ,[ME65]3 conditions do not exceed allowable ;❑Does Not ;fan system motor nameplate hp or fan ;system bhp. :❑Not Observable, ❑Not Applicable C403.8.1 ;HVAC fan systems at design ;❑Complies ;See the Mechanical Systems list for values. [ME65]3 conditions do not exceed allowable C]Does Not ;fan system motor nameplate hp or fan' ; system bhp. I❑Not Observable ❑Not Applicable ; C403.8.3 i Fans have efficiency grade(FEG)>_ UComplies [ME117]2 :67.The total efficiency of the fan at ;❑Does Not the design point of operation <= 15% ❑Not Observable; ;of maximum total efficiency of the I fan. ;❑Not Applicable ; C403.8.3 )Fans have efficiency grade(FEG)>_ ;❑Complies ; [ME117]2 167.The total efficiency of the fan at !❑Does Not ;the design point of operation<= 15% ; ,of maximum total efficiency of the ;❑Not Observable 'fan. ;❑Not Applicable C403.8.3 Fans have efficiency grade(FEG)>_ ;❑Complies EME117]2 67.The total efficiency of the fan at :❑Does Not ;the design point of operation <= 15% ; of maximum total efficiency of the ;❑Not Observable 1 fan. ;❑Not Applicable 'C403:8.3 I Fans have efficiency grade(FEG) >_ ;❑Complies [ME117]2 67.The total efficiency of the fan at ;❑Does Not the design point of operation <= 15% ' of maximum total efficiency of the, ;❑Not Observable I ifan. ;❑Not Applicable ; C403.12.1 I Systems that heat outside the building ❑Complies ,[ME71]2 ;envelope are radiant heat systems :❑Does Not controlled by an occupancy sensing device or timer switch. ❑Not Observable '❑Not Applicable . 1 1 High Impact(Tier 1) 12 1 Medium Impact(Tier 2) 3. Low Impact(Tier 3) Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 6 of 12 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions &Re .iD C403.2.3 ;HVAC equipment efficiency verified. ;❑Complies ;See the Mechanical Systems list for values. [ME55]2 ;❑Does Not ;❑Not Observable ;❑Not Applicable C405.8.1. ;New traction elevators with a rise of ;❑Complies ; 1 75 feet or more have a power ;❑Does Not [ME36]3 ;conversion system that complies as ; follows: C405.8.1.1.1 Induction motors;❑Not Observable !with a Class IE2 efficiency ratings are :❑Not Applicable ;be used.C405.8.1.1.2 Transmissions does not reduce the efficiency of the combined motor/transmission below ;that shown for the Class IE2 motor for ; lelevators with capacities below 4,000 ;lbs.C405.8.1.1.3 Potential energy released during motion recovered with; ; a regenerative drive that supplies electrical energy to the building ; electrical system. ; C405.10 ;Commercial kitchen equipment shall ;❑Complies [ME37]3 comply with the minimum efficiency :❑Does Not ;requirements of Tables C405.9(1) !❑Not Observable ithrough table C405.9(5). ;❑Not Applicable C403.2.2 ;Natural or mechanical ventilation is ;❑Complies [ME59]1 :provided in accordance with ;❑Does Not International Mechanical Code Chapter 4. Mechanical ventilation has ;❑Not Observable capability to reduce outdoor air supply:❑Not Applicable ;to minimum per IMC Chapter 4. ; C403.7.1 ;Demand control ventilation provided ;❑Complies [ME59]1 :for spaces>500 ft2 and >25 ;❑Does Not ;people/1000 ft2 occupant density and ; ;served by systems with air side I❑Not Observable economizer, auto modulating outside �❑Not Applicable air damper control,or design airflow >3,000 cfm. 1 C403:7.2 {Enclosed parking garage ventilation !❑Complies TME115]3, ;has automatic contaminant detection !❑Does Not and capacity to stage or modulate fans to 50%or less of design capacity.;❑Not Observable ;❑Not Applicable ; C403.7.6 ;HVAC systems serving guestrooms in ;❑Complies ;[ME141]3 ';Group R-1 buildings with > 50 ;❑Does Not guestrooms: Each guestroom is provided with controls that ❑Not Observable automatically manage temperature ❑Not Applicable ;setpoint and ventilation(see sections ; C403.7.6.1 and C403.7.6.2). ; ! C403.7.4 Exhaust air energy recovery on ;❑Complies [ME57]1 systems meeting Table C403.7.4(1) ;❑Does Not and C403.7.4(2). I ;❑Not Observable! ;❑Not Applicable C403.7.5 i Kitchen exhaust systems comply with ;❑Complies [ME11'6]3, ;replacement air and conditioned ;❑Does Not supply air limitations, and satisfy hood rating requirements and maximum ;❑Not Observable exhaust rate criteria.See section ❑Not Applicable ; details. ; 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3' Low Impact(Tier 3) Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 7 of 12 . , Section # Mechanical Rough-in Inspection Complies? Comments/Assumptions &Re .ID C403.11.1;HVAC ducts and plenums insulated in ;❑Complies jaccordance with C403.11.1 and 0Does Not C403.11.2;constructed in accordance with [ME60]2 IC403.11.2,verification may need to ;❑Not Observable occur during Foundation Inspection. �❑Not Applicable C403.4.1. ;Heating for vestibules and air curtains ;❑Complies ; 4 Iwith integral heating include ElDoes Not [ME6312 ;automatic controls that shut off the ;heating system when outdoor air ❑Not Observable ,temperatures>45F.Vestibule :❑Not Applicable ;heating and cooling systems ; 'controlled by a thermostat in the vestibule with heating setpoint<= ;60F and cooling setpoint>=85F. C403.10, ;Refrigerated display cases,walk-in ;❑Complies C403.10.1!coolers or walk-in freezers served by �❑Does Not remote compressors and remote C4'03.10.2;condensers not located in a ❑Not Observable [ME123]3 condensing unit, have fan-powered �❑Not Applicable condensers that comply with Sections ;C403.5.1 and refrigeration compressor: ; :systems that comply with C403.5.2.. Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3.1 Low Impact(Tier 3) Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 8 of 12 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions &Re .ID C405.6 Low-voltage dry-type distribution MComplies [EL26]2' electric transformers meet the ;❑Does Not minimum efficiency requirements of Table C405.6. ,❑Not Observable; S j❑Not Applicable C405.7 ;Electric motors meet the minimum ;❑Complies ; [EL27]2 lefficiency requirements of Tables T❑Does Not ;C405.7(1)through C405.7(4). ;❑Not Observable ;Efficiency verified through certification, under an approved certification :❑Not Applicable ; program or the equipment efficiency ratings shall be provided by motor I !manufacturer(where certification I programs do not exist). ; C405.8.2 Escalators and moving walks comply ;❑Complies [EL28]2 ,with ASME A17.1/CSA B44 and have ❑Does Not automatic controls configured to ;reduce speed to.the minimum i❑Not Observable i permitted speed in accordance with �❑Not Applicable ASME A17.1/CSA B44 or applicable local code when not conveying passengers. C45.9 ;Total voltage drop across the I.❑Complies ; [EL29]z _ �combination of feeders and branch :❑Does Not circuits<=5%. ;❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) :3 Low impact(Tier 3) Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 9 of 12 Section # Final Inspection Compiles? Comments/Assumptions &Re .113 C303.3, Furnished O&M manuals for HVAC ;❑Complies 1-408.2.5. ;systems within 90 days of system ;❑Does Not 3 acceptance. [FI8]3 ;❑Not Observable ❑Not Applicable ; ; C403.3.1 ;HVAC systems and equipment ;❑Complies [F127]3 ;capacity does not exceed calculated :❑Does Not loads.See section details. ' ;❑Not Observable ❑Not Applicable C403.2.4. ;Heating and cooling to each zone is ;❑Complies 1 ;controlled by a thermostat control. ;❑Does Not [F[47]3 ;Minimum one humidity control device ;per installed ;❑Not Observable :humidification/dehumidification :❑Not Applicable I system. C403.2.4. ;Heating and cooling to each zone is ;❑Complies 1 controlled by a thermostat control. ;❑Does Not [FI47]3 ;Minimum one humidity control device ; ;per installed :❑Not Observable; humidification/dehumidification :❑Not Applicable system. ; C403.2.4. ;Heating and cooling to each zone is ;❑Complies 1 :controlled by a thermostat control. i❑Does Not [FI47]3 ;Minimum one humidity control device :per installed ,❑Not Observable; humidification/dehumidification ;❑Not Applicable system. ; C403.2.4. Heating and cooling to each zone is ;❑Complies 1 :controlled by a thermostat control. ;❑Does Not [F147j3 ;Minimum one humidity control device !per installed ;❑Not Observable; humidification/dehumidification ❑Not Applicable system. C4014.1. ;Thermostatic controls have a 5 IF ;❑Complies 2 �deadband. ;❑Does Not [FI38]3 ;❑Not Observable; ❑Not Applicable 'C403.4.1. ;Temperature controls have setpoint ;❑Complies 3 overlap restrictions. ;❑Does Not .[F[20]3- ; ❑Not Observable; ❑Not Applicable C403.4.2 ;Each zone equipped with setback ;❑Complies ; [FI39]3 :controls using automatic time clock or ;❑Does Not :programmable control system, ;❑Not Observable; ❑Not Applicable C403.2.4. ;Automatic Controls: Setback to 55°F ;❑Complies 2.1, (heat)and 85IF (cool); 7-day clock, 2- {❑Does Not C403.2A. ;hour occupant override, 10-hour ; 2.2 backup :[]Not Observable; [F140]3 :❑Not Applicable ; r , C404.3' ;Heat traps installed on supply and ;❑Complies [FI1'1]3 discharge piping of non-circulating ElDoes Not ;systems. '! Not Observable; ' ;❑Not Applicable 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) T3'1 Low Impact(Tier 3) Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 10 of 12 Section # Final inspection Complies? Comments/Assumptions &Re .ID C404.4 - iAll piping insulated in accordance with I❑Complies [FI25]? ')section details and Table C403.11.3. C❑Does Not ! I❑Not Observable ❑Not Applicable C408.1.1 ;Building operations and maintenance I❑Complies [FI57]1 :documents will be provided to the ElDoes Not owner. Documents will cover manufacturers' information, I❑Not Observable :specifications,programming :❑Not Applicable ;procedures and means of illustrating ; Ito owner how building,equipment and ;systems are intended to be installed, maintained, and operated. ; Additional Comments/Assumptions- 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) JtJTJ Low Impact(Tier 3) Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 11 of 12 Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 12 of 12 COMcheck Software Version 4.1.5.3 EFI:LLE COPY Interior Lighting Compliance Cert' ' C2, 1%%•EE W/4� Project Information r_ OC Energy Code: 2020 NYStretch Energy Code-2018 IECC Project Title: Aerie 3875 ' Project Type: Alteration 085 (0 'P�ESSIO�P� Construction Site: Owner/Agent: Designer/Contractor: The Outlets at Lake George American Eagle Outfitters,INC Wilson&Associates Engineering Lake George, NY 77 Hot Metal Street DPC Pittsburgh, PA 15203 1257 Perry Highway,Suite 201 412-432-3300 Portersiville,PA 16051 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Retail 3665 0.91 3335 Total Allowed Watts= 3335 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Retail(3665 sq.ft.) Track lighting 1: Wattage based on current limiting device capacity 0 0 340 340 Track lighting 2: Wattage based on current limiting device capacity 0 0 480 480 Track lighting 3: Wattage based on current limiting device capacity 0 0 500 500 Track lighting 4: Wattage based on current limiting device capacity 0 0 500 500 Track lighting 5: Wattage based on current limiting device capacity 0 0 280 280 LS48:LINEAR STRIP:Other: 2 1 24 24 LS96:LINEAR STRIP:Other: 4 14 48 672 PA:PENDANT GLOBE:Other: 1 19 24 456 PA2:BULB ON STRING:Other: 1 8 5 40 PA3:PENDANT GLOBE:Other: 1 1 9 9 V:VANITY:Other: 1 1 20 20 Total Proposed Watts= 3321 Interior Lighting • . Interior Lighting Compliance Statement Compliance Statement. The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2020 NYStretch Energy Code-2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Justi 2-3-22 Name- i E Signature Date FEB 10 2022 TOWN OF QUEENSBURY BUILDING&CODES Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 1 of 7 COMcheck Software Version 4.1.5.3 Inspection Checklist Energy Code: 2020 NYStretch Energy Code - 2018 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Re .ID C103.2 ;Plans, specifications,and/or ;❑Complies [PR4]1 calculations provide all information ;❑Does Not with which compliance can be :determined for the interior lighting ;❑Not Observable jand electrical systems and equipment :❑Not Applicable ; ;and document where exceptions to ;the standard are claimed.Information ;provided should include interior :lighting power calculations,wattage of: bulbs and ballasts,transformers and control devices. C406 ;Plans,specifications, and/or ;❑Complies [PR9]1 :calculations provide all information UlDoes Not ;with which compliance can be ; ; ;determined for the additional energy ;❑Not Observable efficiency package options. ;❑Not Applicable ; C405.11 ;New parking garages and new parking ;❑Complies ; [PR38]3 lots powered by the energy services ;❑Does Not ;for a building,and with 10 or greater parking spaces, provide either: 1. :❑Not Observable Panel capacity and conduit for the 1❑Not Applicable ;future installation of minimum 208/240V 40-amp outlets for 5 i ; percent of the total parking spaces ;and not less than two parking spaces; ; or 2. Minimum 208/240V 40-amp outlets for 5 percent of the total ;parking spaces and not less than two ;parking spaces. C405.12 New buildings comply with the ;❑Complies [PR39]3 ;provisions of Appendix CA:Solar ;❑Does Not Ready Zone. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 2 of 7 Section # Rough-in Electrical Inspection Complies? Comments/Assumptions &Re .ID C405.2.2. ;Spaces required to have light- ;❑Complies ; 2 :reduction controls have a manual QDoes Not [EL22]1 ;control that allows the occupant to ,reduce the connected lighting load in ;❑Not Observable a reasonably uniform illumination ;❑Not Applicable ; pattern >=50 percent. C405.2.1, ;Occupancy sensors installed in ;❑Complies ; C405.2.1. :classrooms/lecture/training rooms, :❑Does Not 1 :conference/meeting/multipurpose [EL18]1 :rooms,copy/print rooms, :❑Not Observable :corridor/transition areas, :❑Not Applicable ;lounges/breakrooms, enclosed offices, open plan office areas, restrooms, :storage rooms,locker rooms, ;warehouse storage areas, and other spaces<=300 sgft that are enclosed by floor-to-ceiling height partitions. Reference section language ; �C405.2.1.2 for control function in ;warehouses and section C405.2.1.3 ;for open plan office spaces. C405.2.1. ;Occupancy sensors control function in ;❑Complies 2 !warehouses: In warehouses,the ;❑Does Not [EL19]1 ;lighting in aisleways and open areas is, ;controlled with occupant sensors that ;❑Not Observable ;automatically reduce lighting power :❑Not Applicable ;by 50%or more when the areas are unoccupied.The occupant sensors ; ;control lighting in each aisleway independently and do not control lighting beyond the aisleway being ; controlled by the sensor. C405.2.1. :Occupant sensor control function in ;❑Complies 3 :open plan office areas: Occupant ;❑Does Not [EL20]1 ;sensor controls in open office spaces ; ; ;>=300 sq.ft. have controls 1) ❑Not Observable, ;configured so that general lighting can;❑Not Applicable ;be controlled separately in control ; ;zones with floor areas<= 600 sq.ft. within the space,2)automatically turn! ;off general lighting in all control zones within 20 minutes after all occupants have left the space, 3)are configured so that general lighting power in each control zone is reduced by>=80%of ;the full zone general lighting power ;within 20 minutes of all occupants ; leaving that control zone,and 4)are configured such that any daylight responsive control will activate space ; general lighting or control zone ;general lighting only when occupancy ;for the same area is detected. ; C405.2.2, ;Each area not served by occupancy ;❑Complies C405.2.2. ;sensors(per C405.2.1)have time- ;❑Does Not 11 +switch controls and functions detailed C405.2.2. ;in sections C405.2.2.1 and C405.2.2.2.;❑Not Observable 2 ;❑Not Applicable ; [EL21]Z a , 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 3 of 7 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions &Re .ID C405.2.3, ;Daylight zones provided with ElComplies C405.2.3. individual controls that control the ;❑Does Not 1, flights independent of general area ❑Not Observable C405.2.3. ,lighting within daylight zones in the 2 following spaces: 1.Spaces with a �❑Not Applicable [EL23]2 ;total of more than 100 watts of ; ;general lighting within sidelit zones ; complying with Section C405.2.3.2. ;General lighting does not include ; 'lighting that is required to have specific application control in ; accordance with Section C405.2.4.2. ; ;Spaces with a total of more than 100 ;watts of general lighting within toplit zones complying with Section ; C405.2.3.3.See code section C405.2.3.1 Daylight responsive ; ; ;control function and section ; C405.2.4 ;Separate lighting control devices for ;❑Complies ; [EL26]1 :specific uses installed per approved ;❑Does Not lighting plans. ; ,❑Not Observable ❑Not Applicable C405.2.4 ;Additional interior lighting power ;❑Complies [EL27]1 :allowed for special functions per the ;❑Does Not ;approved lighting plans and is ,automatically controlled and ❑Not Observable separated from general lighting. ;❑Not Applicable ; C405.3 ;Exit signs do not exceed 5 watts per ;❑Complies [EL6]1 :face. ;❑Does Not ;❑Not Observable ❑Not Applicable C405.6 ;Low-voltage dry-type distribution )❑Complies ; [EL26]2 !electric transformers meet the ;❑Does Not minimum efficiency requirements of ; ITable C405.6. ;❑Not Observable ;❑Not Applicable C405.7 ;,Electric motors meet the minimum ;❑Complies ; [EL27]2 efficiency requirements of Tables ;❑Does Not ;C405.7(1)through C405.7(4). ;❑Not Observable ;Efficiency verified through certification under an approved certification ,:❑Not Applicable program or the equipment efficiency ; i ratings shall be provided by motor ; manufacturer(where certification programs do not exist). C405.8.2 ;,Escalators and moving walks comply ;❑Complies [EL28]2 with ASME A17.1/CSA B44 and have ;❑Does Not automatic controls configured to reduce speed to the minimum ;❑Not Observable )permitted speed in accordance with ;❑Not Applicable ;ASME A17.1/CSA B44 or applicable ; local code when not conveying ; passengers. C405.9 )Total voltage drop across the )❑Complies ; [EL29]2 ;combination of feeders and branch ;❑Does Not ;circuits<=5%. ; ; ❑Not Observable ;❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 13 JLow Impact(Tier 3) Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 4 of 7 I I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Ter Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 5 of 7 Section # Final Inspection Complies? Comments/Assumptions &Re .ID C303.3, :Furnished O&M instructions for 1❑Complies C408.2.5. ;systems and equipment to the :❑Does Not 2 ;building owner or designated [FI17]3 ;representative. UNot Observable ;❑Not Applicable C405.4.1 ;Interior installed lamp and fixture ;❑Complies ;See the Interior Lighting fixture schedule for values. [FI18]1 :lighting power is consistent with what :❑Does Not is shown on the approved lighting ; ;plans,demonstrating proposed watts ;❑Not Observable are less than or equal to allowed :❑Not Applicable watts. ; C408.1.1 ;Building operations and maintenance ;❑Complies [FI57]1 :documents will be provided to the ;❑Does Not owner.Documents will cover manufacturers' information, '❑Not Observable;❑Not Applicable :specifications,programming ; ;procedures and means of illustrating ; to owner how building,equipment and; :systems are intended to be installed, ;maintained,and operated. C408.3 ;Lighting systems have been tested To ;❑Complies [FI33]1 !ensure proper calibration,adjustment, ;❑Does Not programming,and operation. ;❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Ter Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 6 of 7 Project Title: Aerie 3875 Report date: 02/03/22 Data filename: D:\WNA\Dropbox(WNA)\Projects\American Eagle Outfitters\3875 (21-0802)\ComCheck\3875.cc Page 7 of 7 r -- — —— --- -- -- ---- - ---- —--- f r 1 I I t? •>> Y•M l i } rr• r 4 }i t�'"' ` r 7y r%r,• R{ ��';.i�, ••?;.�f�;r.'!,�1.. 4 f�: },�Sj. .ti +r,)•. \r �§ }J;�> +{ J •j' r+. �i�•'r J� '21 S A•.r� s' >vi 1,.{E,, '_�%�� �'�.y � :' :•'4 ��l G J.r• �:`llh '�r• t:C�CK;.r.'�. ,d+t�.,.j) py. 1,.�••i}� •\.r Y .>.. ,'��'i.•:•�'.• �!.;. .r�• ,�w•y ;••� r •+ •t' ...r t' I ai'+i� '�'�+nhl' ��• T:i�" t•� .'�S.{i`a� �,'Jt•� t`�1.�'-�G„ � .y. aYS'!.r ..r P%. Y x• !*`,. w 'ir,�• -• 1� ��""� �d�=-y` "�S' .L'�;� -��,.rr gpi:•r- �-r., �`��„��;S.:i H r��=•r.�'.i.^.. w;!2=�•1:: v-ra •�:t,ti'. ?.,f t.1�y,,tf-,/j7. ;...i• ..k� :i� :-�"."^ r�,. � � . D►{:•4 :��� rr. ^ �~•.• ,v ice„:.• n r T•e�x. " •%�•: �?K y,�q�/r i>(: �T6S'�.�a `}.^ I�.�o,•a '\- �. �•'-•,1•" }:-' },•,` r f. �::: It► � � .x�ea;•> `d�._:• �,Gi� :�==• ➢�:a,��'iIr►= •,r Quertificate of Flame jb-5,113talice >� issued by 6x5PECi,VC--r Date treated or manufactured f�a�%• r;{s This is to certify that the materials described on the reverse side hereof have been flame-retardant treated(or are inherently not flanzinable) V . X'yy� FOR Am 7 AT vile- S 97- 62fdllG!5- Y~ t CITY LAX 6'�a2Gt� Z �` Y STATE -✓;, Certification is Hereby made that: ,(check a or b) p (a) the nnictes described on the reverse side of this Certificate have been treated with a flame-retardant chemical r• `.i il d in conformance with the laws of the State of ?nwye VA and the Rules and Regulations of the State fire Marshal. 2 Name of chemical used: ' i Ilk- Method a" ^f,z ofApplication (b) The anicle(s)described on the reverse side hereof Ware made from a flame-resistant fabric or material l• Trade name of flame resistant fabric or material used tFIE °' �r y ' �_.. C•rL11�Vt 11aplirab,lc:'Ile flame retardant process used �� be removed by washing-,;d orWal not� ot%f By 5VP,5x we)x .. -:. j t Name ofdppl4mic'orProduedonSuperintendert ti /�•, ! ,l.Z l: Y '' .(!"•.! J `�.vy,�`� i 4 fj''.��/ �+"'_nJ..�.. :JG+'�� C"r� .{��/[� -t �a L 4-..��F,. �. t .�- fi"t � �ll�., ,,,�)l �• l�. d.if�w• ry.,= I 'l'�i"�`Wr'����;•��..•��1Y� ��. :•'J�`��'Y� S' .t•~ •?>,)f '.�..�� -,G:� t.�xti�� •�'.. � .td}+•f ♦a � /' �N3��.,- A ��� }-C` �w,'¢•tg:;?:�1' :..i'� ja+ �%� 1 Ji s '��J " .1.�';,J� :1-�"x �a q"-i`` '6�"���t ,f7�..i +.. r�,.r"!1C'� .�ji",•�}r `.' t 3 a•..• u.,l• •r.-# � + �•i'�� � f 1 ✓ . 'J'Ji 1�;!' '�•r '..� �� � ilN•i`i• °Sth, ,••i•�.�,,., s.✓'• S`•4% j aJC3 .+ +.i 4R; a*h 7ti1� .rla' 4 fZ •? 4{{��S[[J) .�':{�� "�r�y�vt �' p,s1'..,•l;S 1y.. l`•tG•, ,,.�':•:;i:�^;• :�,�,:~ ,�L i'r tl:.. . r > d�. 4tf2 lU rr'�j�,ri > J d!t :tiV � I jt11.'1..1' ~�121: ' x.�y:1'"�•.:• K.�+"•e",�`••i'=� i I Type of Retardant Material Treated: t . c Coverage: �/�'1 a Sample Tested: Yes No Approved by: I FIRE MARSHAL'S OFFICE Town of Queensbury 742 Bay Road, Queensbunj, NY 12804 "Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW Aerie 1415 Route 9, Suite 110 CC-0889-2021 12/27/2021 3665 sf The following comments are based on a review of submittals: • Verify fire extinguisher location and inspection • Location of exit/Emergency lighting appear adequate. Function test will be required • Lock/ latches shall comply with Chapter 10 of 2020 IFC. • Verify paths of egress • Verify storage • Verify clearances to electrical service panels • CO detection is required, if source is present • Knox Box key is required • NFPA 72 letter of compliance required for any alterations to the fire alarm system. Adding of appliances will require a floor plan to be submitted • NFPA 13 letter of compliance required for any modifications to the sprinkler system • Contractor to exercise caution and provide protection for all fire alarm and sprinkler devices, during construction • HVAC shutdown required if any units are =/<than 2000cfm • Exterior emergency lighting is not found on the drawings • Provide specifications for material listed as drapery • The exit from the stockroom does not appear compliant with IFC Section 1016.2 (5) (2) as no provisions are listed to comply with item 2.4 • Truss ID signage required Fire Marshal 's Office - Phone: 518-761-8206 - Fax: 518-745-4437 firemarshal@queensbunl.net - zvzvzv.queensburlt net Michael J Palmer Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.net Fire Marshal 's Office ■ Phone: 518-761-8206 Fax: 518-745-4437 {iremarshal fteensbunl.net 7MMqueensburt net