Loading...
Signed Inspection Report (Tue May 24, 2022 at 1127 AM)INSPECTION WORKSHEET (PTI-018488-2022) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:PT-0304-2022 Case Module:Permit Inspection Date:Tue May 24, 2022 Inspection Status:Failed Inspector:O'Brien, John Inspection Type:Property Transfer Inspections Job Address:Parcel Number:119 BIG BAY RD Queensbury, NY, 12804 316.13-1-1 Contact Type Company Name Name Primary Owner Sung, Steve Primary Owner Sung, Linda Applicant Sung, Linda Contractor Sanitary Sewer Service Checklist Item Status Building Inspector Notes Failed 5/24/22 Property Transfer Inspection Not Approved - One Drywell is completely full and other Drywell is 3/4 full. - Access risers required on both covers of existing septic tank. Cover is 3-1/2' down from grade. - A new absorption is required existing drywells have failed. Septic tank is a minimum of a 1000 gallon tank and can be reused. - Sewer line from home to tank needs to be replaced. The pipe is thin wall pvc and it appears to pitch back toward home. - Replace d-box Weather Passed Sunny Temperature (Fahrenheit)Passed 61 degrees Test each fixture flow to septic tank Failed May 24, 2022 Page (1) INSPECTION WORKSHEET (PTI-018488-2022) Checklist Item Status Whirlpool tub add 250 gal Failed Garbage grinder add 250 gal Failed Leaking water fixtures Failed Plumbing fixtures tested & confirmed - for flow and point of discharge Failed Access riser? (if yes, depth to cover)Failed Depth below grade to top of tank Failed 3-1/2' risers needed Septic outlet cover ext - Reg 12"+ below grade Failed Septic inlet cover ext - Reg 12"+ below grade Failed Inlet baffle Failed Liquid level AT/ABOVE/BELOW (one) discharge invert Passed At Number of tank compartments Passed One May 24, 2022 Page (2) INSPECTION WORKSHEET (PTI-018488-2022) Checklist Item Status Capacity in gallons Passed 1000 gallon may be 1250 D-box material Failed Recommend replacing Seepage Pits: Number Failed 2 Drywells one failed and one near failure. System appears to have functioned adequately Failed System/components indicate unacceptable Failed Recommend upgrade/expand/replace 1+ components Failed Replace Drywells As-built provided is accurate Failed On-site as-built req'd before insp is complete Failed System needs repairs Failed System passes all function testing Failed 5/24/22 Property Transfer Inspection Not Approved - One Drywell is completely full and other Drywell is 3/4 full. - Access risers required on both covers of existing septic tank. Cover is 3-1/2' down from grade. - A new absorption is required existing drywells have failed. Septic tank is a minimum of a 1000 gallon tank and can be reused. - Sewer line from home to tank needs to be replaced. The pipe is thin wall pvc and it appears to pitch back toward home. - Replace d-box May 24, 2022 Page (3) O'Brien, John