2003-888 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 1280002 (518)761.8201
Community Development-Building&Codes (518)761.8256
CERTIFIC',alTIE F ry
Permit Number. P20030888 Date Issued; Tuesday,March 11,2008
This is to certify that work requested to be done as shown by Permit Number P20030888
has been completed.
Location: 340 QUEENSBURY Ave
Tax Map Number. 523400-297-020.0001-002-000-0000
Owner. GEORGE&CHARLES SICARD
Applicant- GEORGE L SICARD
This structure may be occupied as a:
Commercial Additim By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20030888 Application Number. A20030888
Tax Map No: 523400-297-020-0001-002-000-0000
Permission is hereby granted to: GEORGE L SICARD
For property located at: 340 QUEENSBURY Ave
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: GEORGE& CHARLES 0 SICARD
19 GEORGE St Commercial Addition $3,500.00
LAKE GEORGE,NY 12845-0000 Total Value $3,500.00
Contractor or Builder's Name Address Electrical Inspection Agency
Plans&Specifications
2003-888
2400 SQ FT COMMERCIAL ADDITION AS PER PLOT PLAN SPECIFICATIONS
$336.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,October 29,2004
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town 4Q ee e ne" sOctober 29,2003
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number,: P20030888 .Application Number: A20030888
Tax Map No: 523400-297-020-0001-002-000-0000
Permission is hereby granted to: CTFOR(TF I, STC;ARD
For property located at: 340 QUEENSBURY Ave
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: GEORGE & CHARLES 0 SICARD
19 GEORGE St Commercial Addition $3,500.00
Total Value $3,500.00
LAKE GEORGE, NY 12845-0000
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2003-888
2400 SQ FT COMMERCIAL ADDITION AS PER PLOT PLAN SPECIFICATIONS
$336.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sat day, October 29, 21
(If a longer period is required,an application for an extension must be made to the code Enforcement-cut
nforcement- -r--- -
of the Town of Queensbury before the expiration date.)
00 .
Dated at the To n of ens ay,y), October 29, 2003
SIGNED BY ��' for the`town of Queensbury.
Director of Building&Code Enforcement
Building Permit Application
Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury,NY
(518)761-8256-
A permit must be obtained before beginning construction. Permit File No.
No inspection will be made until applicant has received a Fee paid $ O
valid building permit. All applicants' spaces on this. Rec.Fee Paid $
application,must be completed and must appear on the Reviewed B
application forms y;
Applicant: t9 2 f ��_c CGA i2 ct Owner: %t�-�icP
Address: �5r <egAl_"Ern S y- Address:
Phone#( f P3--Zk,?- t 3 9'3 Phone#(,,,,,,_)
Property Location: Lot Number: / House Number 3Yp t i/ y -�Q
Subdivision Name: --- Tax Map Number: _a Y 7 y— 0 t 2_
Y a New Building: residence /commercial 'Estimated Market Value of Construction:$ ���' •
C Addition: residence/ commercial If an Addition,what will use of new addition be?
o Alteration: • residence,/ oommerciai
o No change to exterior size: residence J com'1 STD 1auv.
a Other work(describe )
Check Occupancyinformation 1' Floor 2° Floor Other floor Total
Below sq.ft. sq.ft. sq.ft. Square Feet
0 Single family dwellin
0 Two fared dwellin. n /t C 1�11
0 Townhouse
0 Multifamily dwelling ,
#of units 3 2t1fl3
o Office rt?11
o Mercantile 5 OF U ;\i(z6ee --
0
0 1 oar detached-garage,
0 2 car detached ggage
0 3 car detached garage
o I car attached garage
0 2 car attached garage
0 3 car.attached gar-9e
Storage building-
commercial
o Storage building-
residentlal
0 er
What is the proposed height of the structure feet inches
Will any second-hand or ungraded lumber be used? If so,for what?
Type of Heating Systam: electric/ oil /.gas/wood /forced hot air/ baseboard/other:
Number of ELEgglagges to be installed O Number of v-yodstoves to be installed tl
List below the persons)responsible for supervision of work as regards to building codes:
Name .Address Phone Number _
Builder R G Ge�C, 7'
Plumber
Mason
Electrician
Dcolaration: please sign below after you have carefully read the statement:
To the best of my knowledge the statements contained in this application,together with the plans and specifications
submitted,are a true and complete statement of all proposed work to be done on the described premises.and that all
Provisions of the Building Code,the Zoning Ordinance and all other-laws pertaining to the proposed work shall be complied
with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Uwe shall
submit,prior to a Certificate of Occupancy or Certificate of Compliance tieing issued,as requested by the Zoning
Administrator or Dirac t0 wilding and Codes,any tallt Survey by a licensed surveyor;drawn to scale,showing actual
location of all now co cti
Signature: — owner,owner's agent,architect,contractor
J
`7.
Fire Marshal's Office - Town of'Queensbury,742 Bay Road,Queensbury,NY
(518)761-8205
Application for Fu Burning Appliances & Chimneys
applicable tong e s.appliances
/
FEB2Q Permit No.
Date 20
Application is hereby made to tIT � a for the issuance of a Building and Use
Permit pursuant to'the New York State I" A-1, ilding Corte. The applicant or owner
and all conditions that are part of
agrees to comply with all applicable laws, ordinances, regu atrons,.
these requirements and also will allow all inspectors to enter premises to perform required inspections.
V NOTE to applicant: Rough-in and Final Inspecti s ar required.Fad D
Applicant Information
(circle appropriate words)
Name: ro 4tlL/#t Stove:5 wood coal pellet
t' -- ace insert
p
Address: Fireplace, factory-built: wood gas 6
Fireplace,.masonry: wood gas
-- Furnace: wood gas oil
Phone: If non-masonary applicance,please provide
Manufacturer Name: �-
Owner:
Address: Model Number:
Chimney Information ]
Phone: (circle appropriate.words)
Masonry block brick stone
Flue tile steel size: inches.
Exact Address: .Y ��
• of construction o nsta lation Factory-Built
Manufacturer name:
Model Number:
Not Listed By: Number:
Construction/Installation must
con orrn to NYS"Fire Prevention &Building Indicate(circle}chimney material:
'Code. Consult available Town of Queensbut >
Double wall / Triple wall / Insulated / Direct venting
Handouts regarding required inspections.
Chimney Liner
�,�r,,�ai�*ac*'re�'.Z7►+esp�*�m�r.t--�o►�.xat csf Qxx�e�b�ry;Nre�t'7f'i'orl�
Fire Marshal Code S Collected S Refunded eceivecl fi vui(re .nded to):
address: —
A 173 3389 (190) Public Safety
A 233 2655 (230)Minor Sal
DATE: _ 7oww (i�vtlo oZ `CJ �
White(Applicant) / Green(Fire Marshal) / Yellow(Bldg.Dept.) 1 Pink&:Goldenrod(Cashier's Dept.)
Commercial Final Inspection Report
Office No.: (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: 5itjJ am/pin Depart: am/pm
742 Bay Road,Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT#:
LOCATION: -Z/,/O n)e?,�Sj-7d;fV A11e- DATE:
C a,Y COMMENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 711/Treads 1111
Vestibules For Exit doors>3000 sq. ft.
All Doors 36 in.w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Water-tight/Other Floors Okay
Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum
Boiler/Furnace Enclosure I hr. or Fire Extinguishing System,
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft, or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area i
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 Y2doors
> 10%> 1000 sq. ft.
3/4Hour Corridor Doors&Closers
Firewalls Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers Fire Doors
Ceiling Fire Stopping, 3,000 sq. ft,Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Si e/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handica ed Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in.,Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in.Beyond[Both sides]
Active Listening System and Signage Assembly Space
Final Electrical
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway;
Water Fountain or Cooler
Building Access All Sides Driven le Surface 201 wide
Okay To Issue Temp. or ermanent Cn;,!!�
Okay To Issue C/C
L:\Building&Codes Forms\Building&Codes\lnspection Forms\Commercial Final Inspection Report.doo
Commercial Final Inspection Report
Office No.: (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Road, Queensbury,NY 1,2804 Inspector's Initials:
NAME: PERMIT#:
LOCATION: DATE: D,// Z
COMMENTS:
A-J f 6
NA
Chimney/"B"Vent Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Ballisters 4 in: Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 711/Treads 11"
Vestibules For Exit doors>3000 sq. ft.
All Doors'36 in.w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. C
Gas Valve Shut-off Exposed&Regulator,(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 Y2doors
> 10%>1000 sq.ft.
3/4Hour Corridor Doors&Closers
Firewalls I Fire Separation;2 Hour, 3 Hour Complete/Fire
Dampers 1 Fire Doors
Ceiling Fire Stopping, 3,000 sg. ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Sri gnage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in.,Checkout 36"
Handicapped Ramp/Handrails Continiious/12 in.Beyond [Both sides]
Active Listening System and Signage Assembly Space
Final Electrical
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if reg.
As-built Septic System La out Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 201 wide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
L:\Building&Codes Forms\Building&CodesUnspection Forms\Commercial Final Inspection Report.doc
Rough Plumbing/Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: 3 Z-" am/pm Depart: an-/pm
742 Bay Road,Queensbury,NY 12804. Inspector's Initials: ft
NAME: PERMIT#: V 3`"
LOCATION: INSPECT ON: 2 e
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2,R-3,R-4 Drain I Vents
Cast Iron,Copper Drain/Vent/Comm. .
Plumbing Veut,/Vents in.Place
Rough Plumbing/Nail Plates
Head or Air Supply:Test
Drain and Vents
5 PSI or 10 ft. above highest
.Connection for 15 minutes
Water Supply Piping
Copper Commercial
Copper,CPVC,Pex One&Two Family
Insulation I Residential Check/Commercial Check
Proper Vent,Attic`Vent
Duct/Hot Water Piping Insulation
If required unheated spaces \
Combustion Air Supply for Furnace `
Duct Work Sealed Properly
COMMENTS:
L:\SueHemingway\Bui]ding.Codes.Inspection.FORMSIRough Plumbing Insulation Report.doe January 28,2003
tN "� Town of Queensbury
Fire Marshal's Office
742 Say Road
Queensbury, NY 12804
Phone (518)761-8205 Fax(518)745-4437
Fire Marshal's l,nspection Report
Request SCHEDULE 7,W,9 17
Received, 1316 INSPECTION ON:
PM ANYTIME
Name; AM
Location:
APPR,. ED
N/A ES NO COMMENTS
EXITS
AISLE WIDTHS
EXIT SIGNS-NORMAL
- BATTERY
EMERGENCY LIGHTING
FIRE EXTINGUISHERS
FIRE ALARM SYSTEM
FIRE SPRINKLER SYSTEM
FIRE SUPPRESSION SYSTEM
HOOD INSTALLATION
STORAGE
COMPRESSED GAS
CLEARANCE TO SPRINKLERS
CLEARANCE TO HEATING
UNITS
CLEARANCE TO ELECTRIC—AL
REQUIRED SIGNAGE
EMERGENCY PLAN
MAXIMUM OCCUPANCY SIGN
CHIMNEY
MASONRY ROUGHIN
ti
FINAL
CHIMNEY
FACTORY BUILT ROUGH IN
-FINAL
WOOD
STOVE ROUGH IN
FINAL
.A
'APPLIAK-,-aE ROUGH IN >L)
VENTED G S
FINAL
FIREPLACE
MASONRY ROUGH IN OK THIS DATE' OK FOR CO NOT OK
FINAL
FIREPLACE
FACTORY BUILT RoUGHIN
TED BY
INSPEC
FINAL
COMI)EV/CHRISJMORD/LEMRS20OI/FIREMARSHALINSPECTIONREPORT-liO22001
YELLOW-OCCUPANT COPY
WHITE-BUILDING DEPARTMENT COPY
Framing /Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive!. am/pm)),�. Depart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:� v—
NAME: ��Ct" PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y , N/A Framing COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams ',-
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top;Plate
1 %z(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft.floor trusses
-Anchor Bolts 6 ft. or less on center
Ice•and snow shield 24 inches from wall
Fire separation 1, 2,3 hour
Fire wall 2, 3,4 hour
Firestopping
.Penetration sealed
16 inch insulation in cavit'"min.
Garage Fire Separation
House side-%inch or.:5/8 inch Type X
Garage side 5/8 inAiype X
Ceiling/wpll/
Windows Habitable Space/Bedrooms ;
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:1SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report doe January 28,.2003
�p �02) 34a-
Boat Stro
30 PSF Snow 9' ad
Tn='y,Octobe'r 17,2003
WOOD BEAM-SIMPLE SPAN
Maximum moment: 8.3 kip ft
at 6'-0 from left due to DL SL I # IS2D
Beam span: 12 feet 0 inches center line to center line
Reaction at left support: 2,808 pounds
Reaction at right support: 2,808 pounds
Reactions include approximate weight of beam
WOOD TYPE:LVL lumber LVL 2800
with the following base table design values:
Fiber stress in bending: Fb=2,800 psi
Horizontal shear: Fv= 250 psi
Modulus of elasticity: E=2.0 million psi
Working fiber stress has been adjusted for:
Load Duration- 1.15
(for DL+LL+SL)
MAX[M]UM PERAHITED working stresses are therefore:
Fb=3,200 psi
Fv= 250 psi
E=2.0 million psi
BEAM SELECTED:
4 inches nominal width
by
10 inches nominal depth
(Actual Size: 3.5 x 9.25 inches) LW L-
LVL Lumber--exactly 2 pieces at 13/4 inches to make up width
Beam will deflect I in 528 under live load
Beam will deflect I in 310 under total load
ACTUAL DEFLECTION at center of beam will be 0.27 inches under live load
ACTUAL FIBER STRESS under fiffl load: 2,030 psi, 63%max
ACTUAL SHEAR STRESS under full load: 113 psi, 45%max
(Loads ignored within distance from end equal to beam depth)
File: 09:56:35