2003-963 Tow N OF QUEENSBURY�. ,, 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518)'161-$256 CERK"I"IFICATE OF OCCUPANCY Permit-Number: P20030963 Date Issued: Monday,August 29,2005 This is to certify that'work requested to be done as shown by Permit Number P-0030963 has been-completed. Tax Map Number: 523400-302-006-0001.025-000-0000 Location: 751 GLEN St Owner: NIGRO COMPANIES Applicant: ACTOR SUPPLY CO. This structure may be'occupied as a: . Commercial Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals,by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals.: TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20030963 Application Number: A20030963 Tax Map No: 523400-302-006-0001-025-000-0000 Permission is hereby granted to: TRACTOR SUPPLY CO. For property located at: 751 GLEN St in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: NIGRO COMPANIES Commercial Alteration $290,OQO.00 20 CORPORTE,WOODS Blvd ALBANY,NY. 12211 Total Value $290,000.00 Contractor or Builder's Name Address Electrical Inspection Agency Plans&Specifications 2003-963 TRACTOR SUPPLY COMPANY 18,437 SQ FT COMMERCIAL INTERIOR ALTERATION AS PER PLOT PLAN SPECIFICATIONS $2,212.44 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday, January 16,2005 (If a longer period is required,an application for an extension must be made to the.code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tk4TLeetWri y,Jariu'ary 16. 2004 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement - i Building Permit'A;Pppication� To- Queensbury-''Dept of Community Development,742 Bay Road,Queensbury,NY - j (518)761-8256 A permit must be obtained before beginning construction. �'e�'- No inspection will be made until applicant has received a P77, aeZ e No. � valid building permit. All applicants' spaces on this F $a ��� application must be completed and must appear on the RPaid $application form. R By; .Applicant: Kurt Schwarz Owner. Nigro Companies- Address: 4 British Amery can B31vd_ Address: 0 Corporate Wo3as Brv-cr. Latham, NY 12�10 Phone#(518 ) 786 _ 6000 A15any, Phone#(5188 )436 _ 8421 Property Location: Lot Number: / House Number 19 p(L} Subdivision Name: Price mite Plaza / formerly Eckert Drugs Tax Map Number: } ! ❑ New Building: residence /commercial ❑ Addition: 'Estimated Market Value of Construction: $290 residence/ commercial .000 ^Alteration: residence/ commercial If an Addition,what will use of new addition be? ❑ No change to exterior size: residence/com'1 tX Other work(describefMced yard ) 125' X 160' Check Occupancylnformation 1' Floor Below sq.fit. 2' Floor Other floor Total sq,ft. sq.ft. Square Feet ❑ Single#huffily dwelling ❑ Two famil dwellin • ❑ Townhouse ❑ Multifamily dwelling #of units ❑ Office ❑x Mercantile x 18, E ❑ Manufacturin ❑ 1 car detached garage __ ❑ 2 car detached garage- _ ❑ 3 car detached garage ❑ 1 oar attach garage PPlicant: cheii garage gent for I"ro'e .11 ro Epen3'Location: Jonart��'�an-res �► �" Parcel ee Unlisteduare ply G S ScbKarz p z t st Cross t. PublicRef.Records. 6 33 acres r rtY weer, � Pro' Deng: SPR 47 2003 2 aP Id: gro om ese Oeto g: 30 Parries Tractor . rs iron: ber IS 2003 Sectio 2 p6-I- 5, display arm IY-store-in;the phcan t,propos n of Ordinance: HC Mod 26, 24 22,23 ea Applicant prop` en�SgaiOseso'p W traction ofa 20;W4men Cciun 1?9_4 40 here 000- ty PI Type of Heating Systam;oeoarsalese farrier clrerd cutdoordisplaaning IO/8/03All , d seeks reliefs'�toie:ice, Yard_ sociated Number of r a to be installed om the was-] rare mated.' ructio_a Par Co _NIA Number of fPooasrv, quireznents. n�ofthe No List below the person(s)r >'s esponsible for supervision of work as regards to building codes: Name Address.i Builder Phone Number Plumber e 4 British AMerican Blvd. Lath'5i NY 6-6000 Mason Electrician r'c NiskaY un a NY F 220-9055 USDcc1-—URU : please sign below after you have carefully read the statement: Y submitted, the best ofmy knowledge the statements contained in this application,together with the plans and specifications submitted,are a#rue and complete statement of all proposed work to be done on the described premises and that all provisions a specified Building Coda the Zoning Ordinance and all other laws pertaining`to the proposed work shall be complied with,whether speci$ed or noted,and that such work is authorized by the.owner. Further,it is understood that 7/we s1ia1I submit,prior to a Certificate o of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director to Build ing and Codes,an .?3 LU S as by a licensed surveyor;drawn to scale,showing actual location of all now construction. tom= Signature' owner,owner's agent,architect,e t. C...J contractor ` s APR. 11.2004 8:35AM BRITISH AMER -DEVELOP`, NO. 865 P. 2/3 Bu)G. Prawn NO. zoos—g63 APPMATION FOR A TPJffORARY CERTMOATE OR OCCUPANCY A TEMPORARY CERTIFICATE OF OCCUPANCY 4s hereby requested for the property located at;, , 751 Gten -y-kc for the following uses: TAactok Supptq Apur i4 13, 2004 DATE SIGN'.AT'tJR.E OF AP&ANT TEMPORARY CMTWC.ATE OF OCCUPANCY The TEMPORARY CERTIFICATE OF O CCTPANCY is.hereby (,APPROVED' }DISAPPROVED with the Collowiug conditions: Ca�rate_0 -dccut�axcu Q tie s fa �nnx coniptet;i.on off: 71' 91TE PLAN USUES TEMPORARY CERTIFICATL,OF OCCUPANCY FEE: (S10..00 DEPown (44o.00 received on,'.-dgA4 I3. 2Q04 Dat of.Lssvanae Airecto� . �c od o nient 111fS TEMPORARY CEl'U'T'IPICATE OF.OCCUPANCY* EXPIRES ' 60 DAYS is ROM THE DATE OF ISSUANCE. NOTE; This Certificate,is NOT VALID unless signed by the.Director of Bldg. Code. Enforcement or his designee, r inn"ivnnM xvi 0s:L0 aal PouZICT/VO C O;m P A; 1 E VXA7FACSIMILE&FIRST CLASS MA' L dune 3'2004 :. Mi'Davzd.Hatin ulreriyx uf'Bulidllgx« -Town,of Queensbury 742 Bay Road Queensbury,+:NY 12804-9725 - :Re: Bullding'Perrm #1003-963' s -Tractor Suppiy Company.';: ; PnbeRite Plaza - Queensbury, .Y k ; . •��Dear IVIr Hatin's� _ ', - _ ' - a ;Flease.accept this•1"eater as a respectful request_for an extension of the.Temporary' Certificate of Occupancyfor the Tractor Sif'' I _Store 1n the Pricekite:Plaza. We _y the process of worlcing to=complete the outstanding site:requirement of installing a landscape,area in front of,the fence area Ai'ter your review„please contact me if you ; =hay.e;-any giiestions or ccimments Sincerely, A t 1vIGRO COMPA Steve J Pow s Real Estate -Ma nab6merit 20 Cocporate'Woods lVd� ,AlbanyNY 12211 PH t5l 436-8421-_FX (518.)'43678429 k F(-OQ� 1�Commercial Final Inspection Report i 'TC) COffice No.: (518) 761-8256 Date Inspection re c epe"e ,-),VP- arQueensbury Building&Code Enforcement Arrive: epart: 742 Bay Road,Queensbury,NY 12804 Inspector's linitia s:_N9—P kA PERMNAME: 7DAT " - Z:]R[ _ nu LOCATION: COMMENTS: Y N NA Z—-:-/A Chimney/"B"Vent Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in.Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 711/Treads 11 Vestibules For Exit doors>3000 sq. ft. LQ i—)All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44" 1)/Canopy or E4ulv. Gas Valve Shut-off Exposed&Regulator_(I 8")Above Grade Floor Bathroom Watertight/Other Floors Okay , Cc>tAV uz:Va Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure I hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft,or Within Line Of Site, Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), I V2doors > 10%> 1000 ss.ft. 3/4 Hour Corridor Doors&Closers Firewalls Fire Separation,2 Hour,3 Hour Complete/Fire Dampers Fire Doors 'Ceiling Fire Sj2ppina, 3,000 sq. ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Sieage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 3611 Handicapped Ramp/Handrails Continuous/12 in.Beyond Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler B ing Acces§,44,Sides by 20' /Driveable Surface 201.wide kay To IssuCTem p>r Permanent C/O Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\FamW\Build1ng&Codes\C.om mercial Final Inspection Report.doc Commercial Final Inspection Report Office No.: (518)761-8256 Date Inspection req 9trec d: Queensbury Building&Code Enforcement Arrive: a pm epart: PM Is_ 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: Z NAME: PERM —00 LOCATION: t+ -1Z-- ZZ>q DATE: CONEWENTS: Y N NA Chimney/"B"Vent Direct Vent Location Plumbing Vent Through Roof 6"/Roof CoTplete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in.Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers.711/Treads 1111 , Vestibules For Exit doors>3000 sq.ft.,' All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv. (c---)— Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum pz�0� Boiler/Furnace Enclosure I hr. or FireExtinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers I Gas Furnace Shut Off Within 30 ft.or Within Line-Of Site Oil'Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 V2 doors >10%> 1000 sq, ft. 1/411our Corridor Doors&Closers Firewalls Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers Fire Doors I Ceiling Fire Stopping, 3,000 sq. ft,Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required I Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Sigliage Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in.; Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond Active Listening System and Signage!Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Requifed or On File Building Number or Tenant Address onBuilding or Driveway Water Fountain or Cooler Building Access All Sides by 20'-/Di i le Surface 201 wide Okay To IssuVem r Permanen i0o--) Okay To Issue 0/C Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection req st ec ive Queensbury Building&Code Enforcement Arrive: a p Depart: a 742 Bay Road,Queensbury,NY 12804 Inspector's Initia NAME,: -CC- PER-MIT -LQ r-5?,- LOCATION: DATE: Y N NA COMMENTS:Chimney/"B"Vent Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in, Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.-38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure I hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 V2doors > 10%> 1000 sq.ft. 3/4Hour Corridor Doors &Closers Firewalls Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers Fire Doors V/ Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 3611 Handicapped Ramp/Handrails Continuous/12 in.Beyond Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if re As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20'wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\ParnW\BuiIding&Codes\Commercial Final Inspection Report.doc Queensbuzy Building & Code Enforcement - Residentia I al Inspec 'on Office No. (518)761-8256 Arrive: �l '� a e t: a pm n Date Inspection request received: _ Inspector's Initials: NAME: PE IT#: LOCATION: , DAB E: --. TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" —T71t Roof Complete/Exterior Finish Complete 1 �1 Guard 30 in.or more � stairs,decks,patios ���������`'\ O Guard at stairwell at 34 in. or more `3 Guard at deck,porches 36 in.or more �� 6 Exterior Finish Complete r , Interior/Exterior Railings 34 in.to 38 in. f Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum '/" Gypsum Grade away from foundation 6 in. with 10£t. ,•jam ������„�.,�� �� �� Handrail Termination at Newell Past or Wall 6 inch clearance to sill plate 1 � Gas Valve shut-off exposed/regulator 18" above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water boiler operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. f Bathroom/Kitchen watertight . ��d Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: ��` Outside every bedroom area: h- Inter Connected: / Battery backup: l Carbon Monoxide Detector \ --0 \0" t Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/1/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl S aces 18"x 24" access, I s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept,Inspection Sticker Flood Plain Certification, if require Oka to issue C I C or C/C7 Tem orar /Permanent L:\PamWlBuilding&Codesllnsvection Forms\Res.Final Insp. form 2.docLast printed 2/12/04 Town of Queenelswry Fire Marshal's Office 742 Bay Road �J Queensbury, IVY 12804 LPhone 7,61w8205 Fax{518) 745-4437 Fire Marshal's Inspection Report � Request G Received: --- ---Permit# Q�_ !�� INSPECTION O'N: �� Name: �p AM GPM AIrIYI'IME Location: PPR VED N/A YES NO COMMENTS EXITS -_- AISLE WIDTHS EXIT SIGNS y NORMAL - BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHERS �� pp� C? FIDE ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE.SUPPRESSION SYSTEM HOOD INSTALLATION � i ✓��� � � �I INTERIOR FINISHES STORAGE L, COMPRESSED GAS - �' �1't/� � c-� I?jA4 J CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING �L��" ������ }} �1✓ I' � �� UNITS CLEARANCE TO ELECTRICAL REQUIRED SIGNAGE EMERGENCY PLAN -- MAXIMUM OCCUPANCY SIGN CHIMNEY MASONRY TROUGH IN FINAIw 00 CHIMNEY FACTORY BUILT ROUGH IN FINAL WOOD STOVE' (ROUGH IN _ am, iJ z VENTED GAS FINAL Lt Fbil APPLIANCE _ROUGH IN FINAL row �a FIREPLACE � t1 MASONRY ROUGH IN OK THIS ®AT .O FOR CO NOT OK FINAL FIREPLACE r FACTORY BUILT TROUGH IN INSPEC1`EI9 BY FINAL COMDEV/CHRISJNVORD/LETTERS2001/FIREMARSHALINS PECTIONREPORT11022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY Town of Q,ueensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone(518)761-8205 Fax(518) 745-4437 Fire Marshal's Inspection Report Request � SCHEDULE Received. Permit# off t(�1 INSPECTION ON: Name: ��� �,�}P�`�l �� o aC1AM PM ANYTIME Location: V y--LI Aft APPROVED N/A YES NO COMMENTS EXITS AISLE WIDTHS EXIT SIGNS-NORMAL ,`� D� •�� (u�� jrJ a51 ,� - BATTERY EMERGENCY LIGHTING xF2,f '.�jGLL`7`J'tQ FIRE.EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM HOOD INSTALLATION INTERIOR FINISHES toe, STORAGE COMPRESSED GAS S CLEARANCE TO SPRINKLERSCLEA RANGE TO HEATINGHEATINGUNIT CLEARANCE TO ELECTRICAL ! 9 REQUIRED SIGNAGE ° EMERGENCY PLAN V,0 MAXIMUM OCCUPANCY SIGN CHIMNEY MASONRY ROUGHIN FINAL CHIMNEY FACTORY BUILT ROUGH IN WOOD FINAL 15 u? f—e " STOVE ROUGH IN �WIlllll j� F �i VENTED GAS APPLIANCE ROUGH IN FINAL FIREPLACE MASONRY ROUGH IN _ OK THIS :%;3S,0R CO NOT Old FINAL FIREPLACE Q FACTORY BUILT ROUGH IN INSPEC ED BY FINAL COMDEVICHRIs IWORnILETTERs oo11FIREMARSHAuNSPECTIONREPORT11022001 YELLOW--OCCUPANT COPY WHITE--BUILDING DEPARTMENT OPY Commercial Final Inspection Report Office No.: (518)761-8256 Date Inspection reque cei Queensbury Building&Code Enforcement Arrive: P /-- Dep rt: a reque Vceiv -'0 a p wez�� 742 Bay Road,Que_nsbuM NY 12804 Inspector's Init' r c;21 NAME: PERMI LOCATION: DATE: 2—' COMMENTS: Y N NA Chimney/"B"Vent Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in.Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 711/Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv._ Gas Valve Shut-off Exposed&Regulator(18")Above Grade ton Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure I hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil'Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), I V2doors > 10%> 1000 sq. ft. 3/4Hour Corridor Doors&Closers Firewalls 1 Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers Fire Doors Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Sieage/Shaft Sealed Handicap2ed Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond V, Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required c,- Final Survey,New.Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20'wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\Build1ng&Codes\Commercial Final Inspection Report.doc Framing /Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: Q4L) am/pm Depart, am/pm 742 Bay Road,Queensbury,NY 1.2804 Inspector's Initials: NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE:" Z- 01 N NIA COMMENTS Kraming Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 3 6 in. or more Headroom 6 ft. 8 in. Notches/Holes Bearing Walls Metal Strapping for Notches Top Plate I V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min, Garage Fire Separation House side V2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\FramiTig Firestopping Inspection Report.doc January 28,2003 Rough Plumbing Insulation Inspection Report Office No. (518) 761-8256 Date Inspection requ eceived: Arrive: Depart: aT/r, Queensbury Building&Code Enforcement p 742 Bay Road,Queensbury,NY 12804 Inspector's Ini Is: e�Arr ive:Inspection Inspector's NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: *f N N/A PVC: R-1,R-2,R-3,R-4 Drain Vents Cast Iron,Copper Drain/Vent/Comm. Plumbin ent/Vents in Place )iWg—h Plumbing/Nail Plates _-T Head or Air Supply Test Drain and Vents 5 PSI or 10 ft.above highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper,CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check -Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly CONTIMENTS: L:\SueHemingway\Building.Codes.Inspection,FORMS\Rough Plumbing Insulation Report.doc January 28,2003 BY THIS NOTICE OF DEFECT THE NEW YORK BOARD OF FIRE UNDERWRITERS BUREAU OF ELECTRICITY 40 FULTON STREET - NEW YORK, NY 10038 on the application of upon premises of AL ROSS ELEC.CO. TRACTOR SUPPLY COMP. 4 WALNUT LANE EAST PRICE RITE PLAZA SCHENECTADY,NY 12309 QUEENSBURY, NY 12804 Application Number: 1192062 Located at PRICERIMPLAZA --QT)-EENSBURY`,-NY-128047- Section: - Block: Lot: Building Permit Number: Regrets to advise that the electrical installation of the stated premises is not in compliance with requirements of the reference standard as set forth below: Item Location Description Reference Std. outlets/conductors 1st Floor concealed unable to see to do cover inspection C/ This notice of defect is issued by: WALTER SONNTAG on the 2nd day of February, 2004. A239 QUEENSBURY,TN TOWN OF QUEENSBURY 74213AY ST. QUEENSBURY,N.Y. 12804 Paoe 1 of 1 Framing /Firestopping Inspection Report Office No. (518)761-8256 Date Inspection re es r cei d: Queensbury Building&Code Enforcement Arrive: a p epart: , X — a 742 Bay Road,Queensbury,NY 12804 Inspector's Initia s: NAME: PERMIT#: LOCATION: uA-7-L\ INSPECT ON: —7 -�f�q TYPE OF STRUCTURE: Y N 'N/A COMMENTS Framing V111, Jack Studs Headers Bracing/Brid ging Joist hangers s Jack Posts/Main Beams Exterior sheeting nailed properly 7 F ,6T-RUJ�---50 .12"O.C. 6 Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2.(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour Fire wall.2, 3,4 hour Firestopping Penetration scaled 16 inch insulation in cavity min. Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7'sf above/below grade 5.0 sf grade L:\SueHemingway\Building,Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 .BRTMHANIMCA.N, 4 British American Boutavard,Laftm,MY.12110 (518)78"OW Fax(518)786-WDI Fax, To From: George Olsen Companr Phone: -7 1 - 8 2-53 Date: 2 ; 4�1 R �e: CC: Comments: cc .. s IN12 S Nl fib .sw+ k V 'd 1H *ON d013A3Q UAV HS111H Ad60:Z[ MZ *� '83j qF&RA ISTING DOOR iIz NEW 6= `x T Ir VER.OPENING HM DOOR AND FRAMETt W/INSUL YI p OFFICE PARTITIONS: 0 5 5 Er STUDS 0 16'-0.r_ *✓ OFFIE 5/T TYPE,x GYP. BD.' ® FROM FLOOR TO 17-0".A,FA 4d-4' OFFICE CELING: 3 5/8716ga. JOISTS 0 24'O.Q 51T GYP. BD. TOP DECK. Stt�IS�PTEN�IDyE}D��ALU,CW..�0�yB'-l4p'iF.F. E-2 {NO Sf qE ON CEILING} ZSM TO a POSTED STOCK ROOM FLOOR PLAN. sir.><w y PWCE �'t�`EiKE SLY KEY PLAN _ S DOLLAR-ME DRAYVIN6 TRLE . • - FIBV'ISM STOCK ROOM OUEEmuffy aum�s�RY NEW YORK BRITISH AMERiCAN CONSTRUCTION ' SERVICES L.L.C. 4 BRMSH AMERICAN BLVD.,COLONIF�'NEW-YORK' ' PRalFCT NO.: - f)AlVECBRUARY 1 20041 4RWINr NO.: $K Z/Z 'd lE 'ON dolh34 flAV HSIIIH AdOI :Zl MZ '931 BRY A C. 4 Srihsh American SaWavard.LadwiL NY 12110 (618)786- WO Fax(618)78"001 4C AV To. au �`� {v'` From: George olsen Company. �cev�sLoc m, Date: 1 �2 . 12e: cfrx=iJJata� cn• ��- ' C�3-9G3CC Comments_ _ 4144 co-A &^v wi �. cw Gic ,rev* 7X e%" - Z/� 'd I9Z '0N, 013A.3O UWd, HSIlI S_ M.W.OG MZ 'Z Ah )t CLOSE EXISTING DOOR & NEW 6-O" 9-OVER OPENING HM DOOR AND FRAME 1L AMTY W/1NSUL o2 �a5 OFFICE.PAR`IONS! OP 4FF1C 3 $/8"STUDS $16°O.C. 205 5/8°TYPE X GYP, 9D. FROM FLOOR TO 12'-V A.F.F. OFFICE CEILING, 3 545,logo. JoIBIS 0 18°'0.0. 1/9 PLYWOOD TOP SUSPENDED ACT CM 0 Vr A. (NO STORAGE ON GUN;) $0 TO,DE pom STOCK ROOM 1 • 2D2 FLOOR PLAN 1 � 5K1 te i DJJ RITE ` TREE SUPPLY KEY PLAN SK DOLLAR TREE DRAW,NO TM4, REVISED STOCK:ROOM QUEENSSURY ❑UCENSBURY' SCALE 1/16'-R1'-0" NEW mw BR1TfSf-I AMERICAN CONSTRUCTION SERVICES L.L.C. 4 BRMSH AMERICAN BLVD. COLDNIF, NEW YORK PROdEcC NO.. — DAIFFEBRWRY 2. 20041 DRAWING NW $ 1 :2 o; a'b QaA unit OvIr F mNotio uismoVidd is uo i ov j-\AungSN;iho\ougTN1Sb;Hid q\59NTelt 78—d\ :J �/Z 'd ti96 'ON dO13n30 N3NV Hflil�B 00:01 Mz 'Z '833 Framing /Firestopping Inspection Report Office No. (518)761-8256 Date.-Inspection re ues iv Queensbury Building&Code Enforcement Arrive:Date-Inspection ALI'X_)(am 742 Bay Road,Queensbury,NY 12804 Inspector's Initia s: NAME: PERMIT#: -7=3 LOCATION: V!-XK__V-_ 7-,A-7—A INSPECT ON: I --Z-7--n:� TYPE OF STRUCTURE: Y N N/A COMMENTS A Framing V- P—:T Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft, floor trusses ������ ` ��� ������C Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall z Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\FramingFirestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (S 18)761-8256 Date Inspection r90: Queensbury Building&Code Enforcement Arrive: a Depart: ` �t� a pm 742 Bay Rd., Queensbury,NY 12804 Inspectors Initial (03- 3 NAME: 'Pr LOCATION: INSPECT ON: - -- 1� TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump. Footing Drain Stone: 12 inch width 6 inches above footing 1 6 mil poly for wet areas under slab Backfill Approval umbing Under Slab '• � [ PVC/Cast/.Copper 1 Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. i L:ISueHemingway\BuiIding.Codes.Inspection.FORMS\Foundation Inspection Report doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection req 4 recei : _ Queensbury Building&Code Enforcement Arrive: pm Depart: _Djm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initia s; NAME: fRMrr#: _ LOCATION: i - - INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation!Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump. Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab , Backfill 'pproval P tubing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:GSueHemingway\BuiIding.Codes.Inspection.FORMSToundation Inspection Report.doc January 28,2003 Framing 1 Firestopping Inspection Report I I—9 Office No. (518)761-8256 Date Inspection re eceiv Queensbury Building&Code Enforcement Arrive: , . D rt: -&)l� a��l � 742 Bay Road,Queensbury,NY 12804 Inspector's itial 03-90 NAME: PERMIT#: LOCATION: INSPECT ON: —CR-: Co TYPE OF STRUCTURE: Y N AIA COMMENTS raming Jack Studs/,Headers Ac Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 3 6 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft,or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2incb or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in. (W) 5.7.sf above below grade 5.0 sf grade LASuelferningway\13 uilding.Codes.Inspection.FORMSTraming Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No, (518)761-8256 Date Inspection re est ceiv Queensbury Building&Code Enforcement Arrive: p e rt: .o a 742 Bay Rd., Queensbury,NY 12804 Inspector's Initi ERNff#:NAME: CO) LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump, Footing Drain Stone: 12 inch width 6 inches above footing 6 mil of for wet areas under slab Backfill Approval <�—Pl6mTbing`7n'der Slab--- PVC/Cast/Copper Foundation Insulation Interior Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Suellemingway\Building.Codes.Inspection.FORMS\roundation Inspection Report-doo January 28,2003 TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY. 12804-5902 Mer'arandum To: Dave Hahn From: MJ Palmer Date: 12/23/2003 Re: Tractor Supply Plan Review Permit#2003-963 • Add(2)smoke detectors,one in each bathroom • Need as builts for sprinkler system • Need letter from sprinkler contractor,indicating system complies with NFPA 13 • HVAC shutdown must be tied into fire alarm panel • Fire extinguisher locations to be determined with contractor H:1Memo.docpahuer12232003tractorsupplyreviewH:lMemo.doc TOWN OF QUEENSBURY-COMMUNITY DEVELOPMENT DEPARTMENT ?Q3 "" BRITISH ,A.MERICAN 4 British American Boulevard, Latham, NY 12110 (518) 786-6000 Fax(518)786-6001 November 20, 2003 Construction of exterior fenced yard and interior renovations including relocation and reconstruction of four restrooms,reduction of the Dollar Tree space and increase of vacant space to accommodate fit-up for tractor supply company. V BY THIS CERTIFICATE OF COMPLIANCE THE 5 5NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 5 BUREAU OF ELECTRICITY 5 5 40 FULTON STREET — NEW YORK, NY 10038 5 5 5 �ti� 5 Upon the application of CERTIFIES THAT upon premises owned by 5 AL ROSS ELEC.CO. TRACTOR SUPPLY COMP. 4 WALNUT LANE EAST PRICE RITE PLAZA 5 SCHENECTADY, NY 12309, QUEENSBURY, NY 12804 5 5 5 Located at PRICE-RITE PLAZA QUEENSBURY, 1141Y 12a04 5 Application Number: 1192062 Certificate Number: 1192062 5 5 Section: Block: Lot: Building Permit: BDC: A239 5 Described as a Commercial occupancy,wherein the premises electrical system consisting of 5 electrical devices and wiring,described below, located in/on the premises at: 5 First Floor, 5 5 5 5 was inspected in accordance with the National Electrical Code and the detail of the installation,as set forth below,was found to be in compliance therewith on the 3rd Day of March,2004. 5 5 Name QTY Rate Rlin Circuit Type 5 Alarm and Emergency Equipment 5 5 Combo Exit and Emergency Light 3 0 5 Emergency Light 7 0 5 Appliances and Accessories Exhaust Fan 1 0 F.H.P. rj 5 Furnace = 5 .0 Electric Heater Unit 1 5 KW Water Heater 1 2 KW 5 Panels 1 200 18 5 Wiring and Devices Receptacle 25 0 General Purpose Fixture 68 0 m.h. Fixture 12 0 Fluorescent Outlet 68 0 Fixture 5 Switch 6 0 General Purposd7-,.--,: Receptacle 5 0 GFCI seal 0 0 1 of 1 5 This certificate may not be altered in anyway and is validated only by the presence of a raised seal at the location indicated. ff IVQfflPLf d3UUi2PLj-r3Pr PLPCJ'r3p _P 0MOMMOOMPLIUMPOPIPLINEPRIUMPRIEd 0 LJ*L3PLj-QJ"L3j"ffl'i:',li�2�][11PL PjLPffijL3fflPLPLPCjjj: :.I �E.��'1' Z"QJ&PL PL PC J 7r3 L PL PC J DRAFT COPY (3/21/03) CHECKLIST NYS BUILDINGICODE(BC) Building: NYS FIRE CODE (FC) NYS PLUMBING CODE(PC) Location: NYS MECHANICAL CODE (MC) NYS FUEL GAS-CODE(FGC) Date: NYS ENERGY CODE(ECC) Reviewer: Publication Date: May 2002 COMMERCIAL& MULTIPLE DWELLING OCCUPANCIES No, Topic Code Page Required Actual Section No. or Allowed 1 Jurisdiction BC-101.2 2 Flood Plain BC-1603.1..6 285 3 Separated or Non-Separated BC-302.3 18 Occupancies* 4 Occupancy BC-302 17 5- Type of Construction BC-Table 601 81 6 No. of Sleeping Units/Level BC-202 14& No. of Units—Total 31 No. of Occupants BC-Table 1003.2.2.2 201 7 Covered Malls BC-402 33 HI-Rise (75' Rule) BC-403 86' Atriums BC-404 37 8 Basement Definition BC-502.1 71 (See page 8 of this check list) Legend: NR= Not Required ISIS= Not Shown NA.= Not Applicable Note: Non-separated occupancies impose the most restrictive requirements JAM Page 1 of 10 No. Topic Code Page Required Actual Section No. or Allowed 9. Heights& Building Areas Maximum Tabular Area BC-Table 503 72 Maximum Tabular Height BC Table 503 72 Maximum Stories BC-Table 503 72 Mezzanines BC-505 73 10. Sprinkler System (water) BC-903 168 Basement Sprinkler 'BC-;903.2.10.1 170 Water Source Sprinkler BC-903.3.5 172 Water Source Site FG-508.1 31 11. Frontage&Sprinkler Credits Area Modifications (cald.) BC-506 74 Height Modifications BC-504 73 12. Height&Area Summary: HYArea HtIArea Tabular Area BC-Table 503 72 Frontage Credit BC-506 '74 Sprinkler Credit BC-506.3 75 Total Allowable Area Max Aggregate Area BC-503.3 73 (Allowable Area/Fir. x No. of Stories up to 3 maximum) 13. Fire Apparatus Road FC-503.1 29 (150'rule) ,IQ 4 _EC WE-5- 3 14. Exterior Walls Distance Separation* BC-Table 602 82 .Exterior Wall Openings BC-Table 704.8 87 Parapets BC-704.11 88 Exterior Wall Coverings' RC-Table 1405.2 267 Exterior Wall Finishes BC-Table 1406.2 261 Combustible Distance separations are doubled if fire fighting water is not available (FC-508.1.3). NOTES; JAM Page 2 of 10 • C No. Topic Code Page Required Actual Section No. - or Allowed 15. Fire Rated Construction Incidental Use Areas BC-Table 302.1.1 17 Accessory Occupancy BC-302.2 18 Mixed Occupancy BC-Table 302.3.3 19 Control Areas BC-414.2 52 Fire Walls BC-705 89 Fire Barrier BC-706 91 Shaft Enclosure BC-707 92 Fire Partition(Tenant Sep.) BC-708 95 Smoke Barriers BC-709 96 Opening Protectives BC Table 714:2 101 Fire Blocking BC-716 107 Draft Stopping BC=716.3 108 16. Space- 4 L c a.)4 � 4'ji he- ae* 2 Min. Rm. Dimensions BC-1207.1 251 Min. Ceiling Height BC-1207.2 251 17. Ventilation (Nat. or Mech.) BC-1202.1 249 18. Light(Nat. or Mech.) BC-1204.1 250 19. Exits ` "-> JA''td !°c /,t.2.1 �l8 Occupancy Load BC Table 1003.2.2.2 201 One Exit Permitted BC Table1005.2.2 224 Stair Enclosure BC-1005.3.2 224 Emergency Egress BC-1009.1. 235 Distance of Travel BC Table 1-004.2.4 220 Aisle Width BC-1004.3.1.1 221 Corridor Width BC-1004.3.2.2 221 Capacity of Exits(ca/c.)- BC-Table 1003.2.3 202 Corridor Wall Fire.Rating BC-Table1004.3.2.1 %222 Corridor Dead End BC-1004.3.2.3 222 Door Width BC-1003.3.1.1. 208 Door Swing BC-1003.3.1.2 208 Panic Hardware BC-1003.3.1.9 213 20. Riser BC-1003.3.3.3 213 Tread BC-1003.3.3.3 213 Width BC-1008.3.3.1 213 Headroom BC-1003.3.3.2 213 Vertical Rise BC-1003.3.3.E 215 Handrails BC-1003.13.11 215 i'�1au use 12- C 3 C lc�3.3,3� a1S JAM Page 3 of 10 No Topic Code Page Required Actual Section No. or Allowed 21. Structural Snovw�oading—Ground BC Fig 1608.2 296 Snow Loading—Roof(talc.). ASCE-7-98 Drifting Snow BC-1608.7 295 Ponding BC-1608.3.5 295 Floor Loading BC Table 1607A 291 Balcony Loading BC-Table 1607.1 291 Wind Loading (talc.) BC-1609 297 Roof Walls Windows Seismic Loading (talc.) BC-1614 315 Foundation Depth BC-1805.2 398 . 22. Interior Finishes BC-Table 803.4 161 23. Swimming Pools BC-3109 629 24. Sun Rooms BC Appendix 1 693 lectrical it Lights or Signs BC-1003.2.10 203 it C_3rEergency Lights BC-1003.2.11.2 204 mergency Power BC-2702 611 General Lighting-Exits-Stairs -B.C-1003.2.11 204 Oki 26. HC ACCESS '""Exempt Buildings BC-1 104.4 238 Parking BC-Table 1106.1 - 239 Route BC-1 104.1 . 238 Entrance BC-1 105.1 239 i of Sleeping Rooms BC-Table-11 07.6.1.1 241 #of Dwelling Units BC-1 107.6.2 241 Toilet Facilities BC-1 109.2 244 Service Counters BC-1 109.12.3 246 Areas of Refuge BC-1003.2.13.5 207 Signage Supplemental HC Req'mts Appendix E 681 27. INSPECTIONS BC-1704 379 Notes: 2 pis JAM Page 4 of 10 No. Topic Code Page Required Actual Section No. or Allowed Fire Protection,Eguipment Centrql Station Monitoring FC-901.9 52 r1446- Sprinkler Systems FC-963 55 Other Extingushing Syst FC-904 59 Kitchen Hood Extinguisher FC-609.8 41 Standpipe Systems FC-905 62 Fire Extingushers FC-906 64 Fire Alarm Systems &SD FC-907.2 66 c Fire Alarm Boxes+'Z Wef FC-907.4.1 9O?-9 72;73 Smoke Detection FC-907.2.10 68 Hi-Rise Fire Safety FC-907.2.12 69 Visible Alarms FC-Table 907.10.1.2 73, Smoke Control FC-909 75 Smoke Vents FC-910 82 Fire Pumps FC-913 85 29. Plumbing Code Fixture Count PC-Table 403.1 21 1A Seouc, S;,k Water Supply Service Pipe Size PC-603 33 Fixture Pipe Size PC-603.1 33 Pipe Material PC-Table 605.4 36 Labor Law Art. 1 O-A UFPBC-904.6 - 12,340 Pipe Insulation See Energy Code Backflow Prevention PC-Table 608.1 41 Sprinkler System PC-608.16.4 44 Lawn Irrigation PC-608.16.5 44 Pipe Freezing PG-305.6 14 Sanitary Drainage Drain Pipe Size PC-Table 709.1 54 Drain Pipe Material PC-702 -47 Labor Law Art. 10-A UFPBC-904.6 12,340 Vent Size PG-Table 910.4 63 Pipe Hangers PC4able 308.5 17 Air Admittance Valves I PG-917 F 67 1 Notes: JAM Page 5 of 10 No. Topic Code Page Required Actual Section No. or Allowed 30. .Mechanical Code Ventilation Rates MC-Table 403.3 24 Propane Below Grade MC-502.8.1 0.1 31 Dryer Exhaust mc-504 33 Kitchen Exhaust -MC-506 34 Kitchen Hoods MC-507 37 Kitchen Make-Up Air MC-508 39 Chimney Termination MC-Table 511.2 41 Air Plenums MC-602 47 Fire&Smoke Dampers MC-607.5.1 52 Combustion Air ' -MC-701 55 Confined Spaces-Def. MC-202 5 31. Fuel Gas.Code Appliance Location FGC-303 18 Combustion Air FGC-304 19 Clearance to Gombust. FGC-Table 308.2 25 Pipe Material FGC-403 46 Shut Off Valves FGC-409 53 Chimney Termination FGC-FIg. 503.5.4 63 Gas Vent Termination FGC-Fig. 503.6.6 65 Exit Terminal Location FGC-503.8 68 Clothes Dryer Exhaust FGC-613 96 Unvented Room Heaters FGC-620 99 32. Energy Code Prescriptive Method ECCC-Table 602.1(1) 50 High Truss Credit ECCC-602.1.2 51 Pipe Insulation-Heating ECCC-Table 503.3.3.1 44 Duct Insulation-Heating ECCC-Table 503.3.3.3 45 Pipe Insulation-Hot Water ECCCTable 504.2 47. HWH Heat Trap ECCC-504.7 . 47 COMcheck Computer Software Compliance Report Required Notes: JAM 01) Page 6 of 10 LIST OF CALCULATIONS THAT MAY BE REQUIRED FOR A COMPLETE CODE REVIEW. 1. Area Iperease Based Upon Frontage And Sprinkler Increase.. Frontage'Increase: ' If= 1 06(F/P-0.26)W= Answer in % 30 Note: If" 75%when 4 sides accessible&water available Allowable Area: A.=kb,.+Abox�l +Lkw"xl =Answer in Square Feet (BC—Pg. 74) 100 100 2. Exit Capacity Calculations (Table 1003.2.3)(BC-Pg. 202) (Occupancy Load for Exit)x(Egress Width per Occupant) (Required Width) 3. Snow Loading Calculations. (ASCE 7-98)(Eq. 7-1)(p-g-69)&(Eq. 7-2)(pg-70) (ASCE =American Society of Civil Engineers) Pf= 0.7CCtIPg= Flat Roof Snow Load Where: Pf= Flat Roof Snow Load (Calculated Above,Answer in#per SF) C.=Exposure Factor (BC-Table 1608.3.1)(Pg. 297) Ct=Thermal Factor (13C Table 1608.3.2)(Pg.297) 1 = Importance Factor (BC-Table 1604.5)(Pg. 287) P9= Ground Snow.Load (BC Fig. 1608.2)(Pg. 296) P$=QPf=Sloped-Roof Snow Load Where: Ps = Sloped-Roof Snow Load C,= Roof Slope Factor (ASCE 7-98)(Pg. 70) 4. Wind loading calculations. (Refer to Chapter 6 of ASCE 7-98) 5. Seismic Calculations. (See page 10 of this list) 6. COMCheck calculations (For verification of compliance with the Energy Code) JAM Page 7 of 10 8. GRADE.PLANE: A reference plane representing the average of finished ground level adjoining the building at exterior walls.Where the finished ground level slopes away from the exterior walls,the reference plane shall be established by the lowest points within the area between the building and the lot line or,where the lot line is more than 6 feet from the building, between the building and a point 6 feet from the building. 9. MEZZANINE: An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than 113rd of the area-of the room or space in which the level or levels are located. (Mezzanine area does not contribute to the building area or the, height in stories but does contribute to the fire area, aggregate area), 10. SMOKE BARRIER: A continuous membrane, either vertical or horizontal, such as a wall,- floor, or ceiling assembly, that is designed and constructed to restrict the movement of smoke. (Required to have a 1 hr. fire rating). 11. STORY ABOVE GRADE PLANE: Any story-having its finished floor surface entirely above grade plane, except that a basement shall be considered as a story above grade plane where - the finished surface of the floor above the basement is: 1. More than 6 feet above grade plane or 2. More than 6 feet above the finished ground level for more than 50%of the total building perimeter or 3. More than 12 feet-above the finished ground level at any point. JAM Page 9 of 10