SOLAR-0075-2022 -�. Office Use Only
oa
l Permit#: aL.A L_dW
Permit Fee:$
742 Bay Road,Queensbury,NY 12804
P:518-761-8256.www.oueensbury.net Invoice#: �kJ
Flood Zone? Y Reviewed Byl `
SOLAR PANEL PERMIT APPLICATION
SITE INFORMATION:
Project Location: 18 Linden Ave, Queensbury, NY 12804
Tax Map ID#: 302.14-2-65 Subdivision Name:
PROJECT INFORMATION:
Residential: Commercial Other:
x Single Family
Multi-Family
Are the solar panels? x Purchased Leased
Estimated cost of construction: $ 33,145
Total System Capacity Rating (sum of all panels):
Solar PV System: 11.16 kW DC
Select System Configuration: D E C E OW r'
x Supply side connection with micro inverters
Supply side connection with DC optimizers FEB 2 8 2022
Supply side connection with string inverter TOWN OF QUEENSBURY
BUILDING&CODES
Load side connection with DC optimizers
Load side connection with micro inverters
Load side connection with string inverter
Solar Panel Application Revised January 2021
DECLARATION:
1. I acknowledge-that no construction shall be commenced prior to the issuance of a valid permit and will be
completed within a 12 month period.Any changes to the approved plans prior to/during construction will
require the submittal of,amended plans,additional reviews and re-approval.
2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of
Queensbury.After 1 year from the initial application date, 100%of the fee is retained.
3. ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees
and department approval.
4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or
description of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local
building laws and ordinances, and in conformance with local zoning regulations.
5. A third-party electrical inspection will be completed at which time the Town of Queensbury's Building and Codes
Enforcement department will be contacted to complete an inspection of the final installation of the solar panels.
Please sign below to affirm that all answers are correct and that you have met all of the conditions and
requirements to submit a unified solar permit.
I have read and agree to the above:
A.A49 Feb 25, 2022
Thomas Harve7lFeb 25,202213:41 EST)
Homeowner's Signature .� �, Date
Solar Co. Representative Signature Date
Solar Panel Application Revised January 2021
CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL
• Property Owner(s):
Name(s):
Thomas Harvey
Mailing Address,C%S/Z: 18 Linden Ave, ueens ury,
Cell Phone:_( 518 ) 745-5494 Land Line:_( )
Email: tharvey1956@yahoo.com.
• Solar Contractor:
Workers' Comp documentation must be submitted with this application
Business Name: Solar Liberty Energy Systems
Contact Name: Heather Anton
Mailing Address, C/S/Z: 6500 Sheridan Dr,.Ste 120, Buffalo, NY 14221
Cell Phone: ( ) Land Line:_(716 ) 634-3780
Email: heafher.anton so ar I e y.com
6 Electrical Contractor:
Workers' Comp documentation must be submitted with this application
Business Name: Solar Liberty Energy Systems
Contact Name: Heather Anton
Mailing Address,C/S/Z: 6500 Sheridan Dr, Ste 120, Buffalo, NY 14221
Cell Phone: ( ) Land Line:_( 716. ) 634-3780
Email: heatFier.a-n so ar I e y.com
Contact Person for Compliance in regards to this project: Heather Anton
Cell Phone: ( _) Land Line: 716 ) -
3780
Email: heather.anton@solarlibertvcom
Solar Panel Application Revised January 2021
Solar Panel Plan Review
J�JAII wiring in conduit
18" from ridgeline and valleys
jr4Two T foot access ways from ground to ridge one side of roof
Rapid shutdown shown
l roof commercial in compliance with section 1203.4 of fire code
Labeling of conduit and panels
Battery storage in attached garages and Utility Closets separation 'h" on wall and 5/8" on
ceiling if living space above
A4 Battery storage on exterior walls located a minimum 3 feet from doors and windows.
W16 (Individual battery storage system units shall have a maximum rating of 20 kWh.
/,The aggregate rating shall not exceed:
,40 kWh within utility closets and storage or utility spaces
�80 kWh in attached or detached garages and detached accessory structures
73.80 kWh on exterior walls.
___/ 4.80 kWh outdoors on the ground access isles required
MlArHeat detector interconnected to the smoke alarm in building
i�kRooms and areas containing battery storage systems 5/8" Type X, installed on the walls
and ceiling of the room
r
ALIndoor installations exhaust ventilation required for other than lithium-ion
Bollards for impact protection
Revised 1/24/2022
TOWN OF QUEENI SSURY
M1 3ULDING & CODE' ` CPT- Finger Lakes Engineering,PC
2536 State Route 21
_�
---- , ,eviewed 6
'2---Z Canandaigua,NY 14424
EKGIH�ER111� Date'.
office (585)394-3867
Antho ranetti-P cell (585)396-3438
Heather Anton R1490
Associate Project Manager Sheet 1 of 1
Solar Liberty FEB 2 Z�2? February 17,2022
6500 Sheridan Drive Suite 12
Buffalo,NY 14221 TpvNN p� QUBE�ISBURY DF1
BUIL DINGSSLE COPY
RE: Thomas Harvey, 18 Linden venue, Queensbury,NY 12804
Dear Heather, O � p=j O
O r N
Per your request we conducted a Preliminary Structural Condition Assessment that a M
included an on-site visit on 2/10/22, an observational examination of the existing roof o fp
structure, and a review of any drawings,blueprints, or sketches that were available. rt D iN
PV solar panels are proposed for two areas of the roof of this home as summarized c 3
below. The panels are mounted on rails which are attached to the roof with an anchored o I
deck base system installed per manufacturer's specifications and recommendations. rp
� D
I found that the roof structure, as noted on Site Plan PV-S 1,can satisfactorily withstand �p
the additional loads as proposed and will also meet the applicable standards included in
RCNYS 2020 and ASCE 7-16. V
My analysis indicates that the areas of the existing roof,where the additional weight is to N
be located, and only as it applies to Solar Liberty specified equipment and their tributary O
areas, are capable of supporting a total load of at least 57 psf. N
In 2016 the roofing was replaced,was a tear off, and a single layer of asphalt shingle
roofing was added to the existing plywood sheathing.
The maximum existing total load on these areas of the roof is estimated to be 49 psf
(DL=10,LL=39) leaving an available capacity of at least 8 psf. The average weight of
the proposed solar panels and framework is less than 4 psf.
Therefore,the roof framing in these areas will not be overstressed by the installation of
the solar panels and framework.
r
Thank you for the opportunity to be of service, sincerely. OF NEh }'
R? Rti.6O�P_
cr
Anthony R Yannotti Zap 083631
q�F QUEENSBURYFESSIONP�
BGU1ILDIGNG DEPARTMENT
Based on our e
RnPA
FingerLakesEngineering.com
with our commentss d shall not be construe as 1-800-255-8779
indicatng the plans and specifications are in
full compliance with the Building Codes of
New York State.
NOTES: 1.EQUIPMENT LOCATION TO BE FIELD VERIFIED PV SYSTEM SUMMARY
1 N - Ceneml Notee
COMPLIANCE WITH APPROPRIATE STATE AND LOCAL CODES TO BE
VERIFIED,BY AUTHORITY HAVING JURISDICTION - TH6wSTALIAALLBE I PV
:_, TOTAL STC DC SYSTEM SIZE 11.16 kW � LEGEND SYSTEM SHALLBEIN
�.
ACCORDANCE WITH TIE MOST
•, . .� „ - - SOLAR MODULE MODEL SUNPOWERAC a SOt MODULE RECENT NATIONAL ELECTRIC
AND BNG CODES AND
STANDARDSIAS MENDED BY
SOLAR MODULE STC DC RATING 360 W � INVERTER JURISDICTION
SOLAR MODULE INFO 81.3°x 41.2'x 1.8',45.5 Ibs O EASYTO READ METER
'a -• DISC ACCOMBINERBOX
- - - ;'a �„� _ - -.;' I SOLAR MODULE COUNT 31
O -
�, ���•� �• RACKING SYSTEM SUNPOWER INVISIMOUNT UTILITY METER
�n AC_y
RS1.. r qy pSC DISCONNECT
- V PITCH OF ARRAY 8:12
9 Modules _ MNN MAIN BREAKER PANEL
262', ❑. .`= - INVERTER MODEL INTEGRATED MICROINVERTERS _ ELECTRICALTRENCH
22' 77 ---
LC
"I .
ARRAYAZIMUTH 262° ® VENT!NOAND PATHWAYS
- ELECTRICAL STAMP AREA
. _ � ` EAVE HEIGHT 12',22' -
INTERCONNECTION VOLTAGE 240WI(D '
•454 -- - SOLAR ARRAY PERIMETER 161'-10- a
y• / '.) _ _
PV SYSTEM OVERVIEW.
• .:-hY a eW W— I m
�I"dam• �"%','.�',�',"`' � 1R '!..
SOIARUSERTY"
pfp ] 1��1'•
/ ,,;�<,: •► 1 1 6500 Sheridan Drive
01 SDae 120
Buffalo,NY 14221
866-BD-RENEW
o; PI/Installation
Prolesslonal
RS2 :
,22 Modules - q.
262a I_ - !� 1�{ �Cr Harvey Residence
1 { 18 Linden Avenue
221 Oueensbury New York 12804
SITEP.IAN&E UIPMENT
41 p -:saa3�r.,' r AS NOTED PV-S1
16*
, ..4 -
General Notes
INTEGRATED MICROINVERTER PVS6 Sun power
cATV Array Details
(2-WIRE)SYSTEM.TRANSITION TO P ....................1............................... Modem Panel Manufacturer.Sunpower
THNM-2AT NEAREST Ja OR GUTTER Monitoring System
1 2 11 (TYP.) (z)ttte Awc TWIs7ED PaR Panel Model:X22-360 W
I (2)#6 AWG THWN-2
I (1)08 AWG NEUT. 120/240V Panel Count:31
-------- 08 AWG CU GND 1 /3W SERVICE
(1)V EMT/LFMC COND.
i ENTRANCE Array Layout:10M x 2S
11Mx1S
i I Inverter Details
l
10A I
Inverter Model:Built In
I 4 oly:31
II
' I Peak Output Power. 320 W
1 2 10
cFOI O DOOR NF BOA DECO O i Nominal Output Current:1.31 A
°�� t� J Line-to-Line Voltage:240V/1�
UT
TO ACT AS 690.12(C)INTIATION 3
DEVICE i ' System Rating
a De x
M M a a Peak Output Power.9.92 kVA
MBJ I i Nominal Output Current:40.6A
it
• � i i Une-to-Line Voltage:240V/10
O 1 2 lO (2)#B AWG THWN-220A '
(1)IVa AWG NEUT. ' I
(1)#8AWGCUGND
EMT/LFMC COND.
214A This document is proprietary
re x m to Solar Liberty Energy
Systems,Inc.Do not copy or
I I redistribute without prior
• • • Lt L2 N 150A i consent from Solar Liberty
• • •
' I Energy Systems.
GND TO RACK CENTRAL JUNCTIONBOX /(6)#IOAWGTHWN-2
(1)#10 AWG CU GND
(1)1'EMT COND.
CTs I IFC Droving
M&I SUPPLYSIDE TAP p Prerminory Drawing IL13/2I
MDP NOTES: 16DA1240v No. Rovieton/I•eue Data
Q Array#1-31 x Sun power 360W Solar Panels,w/integrated microinverters.Aria is on West RREVER To Confirm grounding is adequate,and that water SOLARIIBEFUT
P eg Y SPLICE TO pipe is not the sole means of GEC
side of house.Homerun to originate at junction between upper and lower roofs.Run conduit EXISTING GEC 6500 Sheridan Drive
down back of house to the right of the deck and enter basement where SE cable goes in. Suite 120
Q 120/240V MLO AC Combiner.100A,do not exceed busbar rating. Buffalo,NY 14221
OSupply Side Tap required AC Fused Disconnect Switch,60A,240V,1-PH/3-WRE,Served with Project Nam•and Addn-
60A fuses.SquareD H222NRB,or Approved Equivalent.Plenty of space to right of MDP for PV Harve Residence
equipment.Mount RSD Initiation device outside near utility meter.Follow SE cable path. LABEL 20 (x3)-Combiner and both AC Disco 18 Linden Avenue
O Utility owned and installed bi-directional energy meter.Utility meter located on North West comer SOLAR PV AC DISCONNECT ueensbury New York 12804
of house,and SE cable runs under deck to MDP location.Meter can not properly secured to RATED AC VOLTAGE 240V
house,check Integrity and inform customer of possible changeout. RATED AC AMPS aD.6A ` swc
SUNPOWER AC PV MODULE SYSTEM DOES NOT REQUIRE A �12/13/2021 12/13/2021
GEC PER THEIR INSTALLATION MANUAL. as NOTED —PV-E1
Willi 0
LARLIBIG Y
THE P0J6n'E @F ENERGY IN'DEREN61EMCF.
Thomas Harvey
18 Linden Avenue, Oumenebury, NY128U4
02/ 082O22
TonyYannotU
Customer Information TOWN OF QUEENSBURY
Homeowner Name Thomas Harvey Email thamoy1856@yohoo.00m
Homeowner Address 10 Linden Avenue,Ouoonobury. Project Number
NY120O4
Project Manager Assigned Heather Anton
Assessment Date 02/10/2022
Outbound Notes
Electrician Name TonyYannooi
Email Route Code Route Code:BomhooLV1
Customers Primary Contact (518)745'5494
Number
Installation 0otaUe
Type ofSystem Roof Mount Engineering Notes Required? No
Structural Report Attached? vou Does desired installation Yes
match Site Plan?
Roof Repairs Necessary? No
|e Trenching Required for No
Are Roof Dimensions No Install?
Required?
Wet Stamp Necessary? No Interconnection Method Supply Side Tap
Photo:Interconnection Point 000pix
Electric Information
Main Disconnect? No Main Panel Condition Good
|e there o Sub Panel Present? No Electric Notes The utility meter enclosure ionot
connected very well with the
Utility Service Cable Condition Good outside of the house.The
oor�000ab|oio�hoon|y�hing
KReinService Panel Main 150ompn Breaker Size holding itto the side of the house
o,the cedar siding
Balance of System Locations Included ioa picture ofthe
&Notem grounding ata copper pipe atthe
water service.
|did not see a second ground at
the utility meter
Bill of Material Notes none
i f
Array Information
Photo:Array 1 Coduit Path See drawing(picture)of Is there an Array 2? No
proposed path.
Service cable runs under the
deck from the utility meter
Also roof dimensions included-
see pix
Smoke&CO Detectors
Are there smoke detectors Yes Is there a smoke/CO detector Yes
present in all bedrooms? present in basemet area of
home?
Is the detector hard-wired? No
Is the detector hard-wired? No
Is there at least 1 smoke/CO Yes
detector located outside of Is there at least one smoke/CO Yes
and within 15 feet of each detector present on each level
bedroom? of the home containing a gas
Is the detector hard-wired? No appliance?
Is the detector hard-wired? No
Additional Site Information
Lift Access Available if No Continuous Internet Access Yes
Necessary? Point Available
Special Requests Type of Internet Access Point Both Wi-Fi&Hard wired
/Requirements by Customer Available?
Panel Upgrade(Y/N) No
Page 2 of 8 Report Created:02/17/2022
Customer Information/Photo of Customer Address Installation Details/Structural Report Attached?
f ".•
Tony Yannotti Tony Yannotti
Loc:43.3195,-73.669 Loc:43.3194,-73.6694
Installation Details/Photo:Interconnection Point installation Details/Photo:Interconnection Point
- , fit`• — � ��� �1 � I is
S
Tony Yannotli Tony Yannotti
Page 3 of 8
Report Created:0 211 7/2 0 2 2
� a N
Al
Six
IT
rr
iff /III St♦. � 'r'F-' f� -IZ-II f�Y �����/T�,y."' e S 'r S'ld
/S�11�1 � (� ram+ •t\ ( "T.iJ ..
I)
Electric Information/Utility Service Cable Condition Electric Information/Utility Service Cable Condition
t•':� � � �",±mac,Was
--- s
itr••� w}, '
[II
........... .......
Q -
�rr�• r Id � .
Tony Yannotti Tony Yannotti
Electric Information/Utility Service Cable Condition Electric Information/Main Service Panel Main Breaker Size
?� �r i r
Tony Yannotti Tony Yannotti
Page 5 of 8 Report Created:02/17/2022
\oe i Ph°to:in�er�r VOcatio°
EtectfictnfOrR'at
veted
• °:Main geN`ce Panet VopO
At
tormatton 1 phot � .s
Etectrieta , .... `
coctntO
rmatioe
Yaa�pn` Ete
1onY
U ctt0 i r
lGeeecato
r+
o i Pppt°-Addittona\ }: � ;. .. �.�� •.r..;�,�."ti �
E\e_trtctn
i:f•�-•�� i!: is '� ,�,
.' l l ... • _ •'a: art,
�,anpott�
(OM
FtePpdCreated•Oyt712�22
1pnY Ya��ptb
Page 6 pt 6
Electric Information!Electric Notes Electric Information!Balance of System Locations&Notes
k ~
1
} III, ➢
i
Tony Yannotti Tony Yannotti
Electric Information/Balance of System Locations&Notes Array Information/Photo:Array 1 Codult Path
i
i
1
9
1
4 N
\ t
Tony Yannotti Tony Yannotti
Page 7 of 8 Report Created:02/17/2022
Array Information/Photo:Array 1 Coduit Path Array Information/Photo:Array 1 Codult Path
tll'i1 it}.'�,• I`I�V ,;: ', � ; InLY,as - s' - - 4 _r_
47
1
Tony Yannotti Tony Yannotti
Loc:43.3194,-73.6695
Page 8 of 8 Report Created:02/17/2022