Loading...
2012-180 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20120180-3 8765 Tax Map No: 302.6-1-2 f "�' 7N WED Permission is hereby granted to: SHIYONG QfU For property located at: 697 GLEN ST In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: SHIYONG QIU z Comm Alt $20,000.00 Owner Address: 697 Glen ST Total Value $20,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications Commercial Alterations 380 s.f.,Bathroom to be ADA compliant Hello.Nails Building Permit Renewed April 22,2019 Building Permit Renewed June 17,2020 $ 350.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday, June 25,2021 (If a longer period.is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the,Town of Queensbury; Monday, June 25,2012 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)_761-8201 Community Development- Building & Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20120180-3 8765 Tax Map No: 302.6-1-2 Permission is hereby granted to: SHIYONG QIU For property located at: 697 GLEN ST In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tyne of Construction Owner Name: SHIYONG QW z Comm Alt $20,000.00 Owner Address: 697 Glen ST Total Value $20,000.00 Queensbury,NY 12804 Contractor or.Builder's Name/Address Electrical Inspection Agency Plans&Specifications Commercial Alterations 380 s.f.,Bathroom to be ADA compliant Hello Nails Building Permit Renewed April 22,2019 $ 250.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Thursday,June 25,2020 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; /J Monday, June 25,2012 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement owe TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20120180-38765 ► ENEWER Tax Map No: 302.6-1-2 Permission is hereby granted to: Shigung Qui For property located at: 697 GLEN ST In the Town of Queensbury,to construct or place at the-above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction . Owner Name: . Shigung Qui z Comm Alt $20,000.00 Owner Address: 697 GLEN ST Total Value $20,000:00 Queensbury,NY 12804 Contractor or Builder's Name/.Address Electrical Inspection Agency Plans&Specifications Commercial Alterations 380 s.f.,Bathroom to be ADA compliant Hello Nails $ 50.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Tuesday,June 25,2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Qu sbury befqftthe xpir n. te. Dated at the T of sb ; y,June 25,2012 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement d TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: P20120180-3 8765 Tax Map No: 302.6-1-2. Permission is hereby granted to: Shigung Qui For property located at: 697 GLEN ST In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Shigung Qui z Comm Alt $20,000.00 Owner Address: 697 GLEN ST Total Value $20,006.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications Commercial Alt.-Hello Nails Permit renewed on 5/8/2017 $0.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Monday,June 25,2018. (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town-of Queensbury before the expiration date.) Dated at the Town of Queensbury; Mon da , un 25,2012 SIGNED BY: for the Town of Queensbury. Direct wilding&Code Enf •cement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: CC-000246-2016 - IP 2012 - 1 E50 Tax Map No: 302.6-1-2" Permission is hereby granted to:. SHIYONG QIU REN � . For property located at: 697 GLEN ST In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: SHIYONG QIU Retail-Mercantile-Alteration $0.00 Owner Address: 697 Glen ST Total Value $0.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency REVISE® Plans&Specifications Commercial Alterati ons 380 s.f.on lst floor 'Hello Nails' Bathroom to be ADA compliant $ 0.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Sunday,June 25,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town Quee ury; �Mo d y, ,2012 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902- (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: P20120180 Application Number: A20120180 Tax Map No: 523400-302-006-0001-002-000-0000 Permission is hereby granted to: MINGLING XIE For property located at: 697 GLEN. St in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: QIU SHIYONG Commercial Alteration $20,000.00 XIE MINGLING Total Value 697 GLEN St $20,000.00 QUEENSBURY NY 12804-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2012-180 Comm. Alteration 380 sf on 1st Flr -HELLO NAILS Bathroom to be.ADA compliant $76.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,June 25,2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration.date.) Dated at the To f.Q 0 o ne 25,2012 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20120180 Application Number: A20120180 Tax Map No: 523400-302-006-0001-002-000-0000 Permission is hereby granted to: MINGLING XIE For property located at: 697 GLEN St in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: QIU SHIYONG Commercial Alteration $20,000.00 XIE MINGLING Total Value 697 GLEN St $20,000.00 QUEENSBURY NY 12804-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2012-180 Comm. Alteration 380 sf on 1st Flr -HELLO NAILS Bathroom to be ADA compliant $76.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,June 25,2015 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o eensbury MO a June 25,2012 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20120180 Application Number: A20120180 Tax Map No: 523400-302-006-0001-002-000-0000 Permission is hereby granted to: jVIINGJING XIE For property located at: 697 GLEN St in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building-Codes and the Queensbury Zoning Ordinance. Twe of Construction Value Owner Address: QIU SHIYONG Commercial Alteration $20,000.00 XIE MINGLING 697 GLEN St Total Value $20,000.00 QUEENSBURY NY 12804-0000 Contractor or Builder's Name/Address Electrical Inspection Agency V 0 Plans&Specifications 2012-180 Comm. Alteration 380 sf on 1st Flr -HELLO NAILS Bathroom to be ADA compliant $76.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,June 25,2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of,QuIuensbury; jondav,J ne 25,2012 �(! f SIGNED BY \ for the Town of Queensbury. Director of Building&Code nforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20120180 Application Number: A20120180 Tax Map No: 523400-302-006-0001-002-000-0000 Permission is hereby granted to: MINGJING XIE For property located at: 697 GLEN St in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. T_vye of Construction Value Owner Address: QIU SHIYONG Commercial Alteration $20,000.00 XIE MINGLING Total Value $20,000.00 697 GLEN St QUEENSBURY NY 12804-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2012-180 Comm. Alteration 380 sf on 1st Flr -HELLO NAILS Bathroom to be ADA compliant $76.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,June 25,2013 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of ueens ury; on ,2012 7 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement l� bu� �t IS .. . - - OFFICE USE ONLY CG »I � �,Io.__.. 1—�_- . FI ire;A TAX MAP NO. �� �'� -- --PERMIT NO. �l `I W' G1 ` FEES: PERMIT_ r _ O (If applicable) ; APR 1.9 =2012 ; TOWN OF QUEENSBURY PRINCIPAL STRUCT E. APPLICATION FOR ZONING A PROt AIkDI&CBUILD7NG PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICAN i�0/BUILDER:. " i n 0 X � OWNER: kikiG`f l (ria C= ADDRESS: leec��hc� r ADDRESS: PHONE NOS q7 711/ - 9,56—. I�y PHONE NOS. 7 -72(- c! CONTACT PERSON FOR BUILDING &CODES COMPLIANCE.: . 6n P AS \�pT_� ONE: LOCATION OF PROPERTY: HAS THERE BE A S E PLAN REVIEW;VARIANCE OR SUB DIVISION'APPROVAL? YES ❑ NO � ���ot� IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL: to 61hi PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT APPLY TO YOUR z o PROJECT 0 W O OJ cc -' O = _ W � J h C� Z CJ F- � O I— � w — z Q ¢ rq Nc) Ou_ F- u_ a20S SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS TOWNHOUSE BUSINESS OFFICE `S� � s� f ye RETAIL- MERCANTILE )C S O h I,n ^� Gt"rr-&, FACTORY OR INDUSTRIAL ATTACHED ----- _—- - -—--- - -- —_— - - f jf is GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINEel,L(J CLI II ESTIMATED CONSTRUCTION COST: DD FUEL TYPE: HEAT TYPE: *HOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? I PROPOSED USE OF BUILDING OR ADDITION: i [L �kb 1 a() ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? "P!ease complete a separate Application for°Fuel Burning Appliances&Chimneys"availabfe in office I .acknowledge<.no construction activities shall be commenced prior to issuance of a valid permit... ;certify that° th'e application; plans, and supporting materials are a true. and complete statement/de'scrip.tion of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulatioris-. I 'acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. have read,an a ee-to the ab Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems)' Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointmpCit) Permission is hereby granted to the above This application / proposed action described Applicant to erect or .alter the .building herein is found to,be in accordance with the described herein in accordance with said ; zoning Laws of the Town of Queensbury.. Application: BUILDING & C DES PROVAL ; ZONING APPROVAL i X ry/'L DAT , DATE . QUESTIONS? CALL 761-8256 OR EMAIL codes(a,)gueensbury.net Office Use Only.- VISIT OUR WEBSITE FOR MORE INFORMATION Operating Permit Issued: Yes o www.gueensbury.net_ Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special,Conditions: Town of Queensbury* Community Development Office* 742 Bay Road,'Queensbury NY 12804 v INSPECTION • 'KSHEET (COMFIN,011038-2021) Town of Queensbury- Building and Codes- Fire Marshal 742 Bay Road-(518)761-8256 Building (518)761-8206 Fire Marshal Case Number: P20120180-38765 Case Module: Permit Inspection Date: Mon Jun 7,2021 Inspection Status: Passed Inspector: O'Brien,John Inspection Type: Commercial Final Inspection Job Address: 697 GLEN ST Parcel Number: 302.6-1-2 QUEENSBURY Contact Type Company Name Name Primary Owner Happy Nails QIU, SHIYONG Applicant Happy Nails QIU, SHIYONG Granted Permission Happy Nails QIU, SHIYONG Checklist Item Status Building Inspector Notes Passed 5/5/21 Commercial Final Inspection Not Approved Remaining Items: - Install lever handle hardware on all entry and passage doors. - Hot water tank relief valve downspouts need to be within 6"of floor. - Install 36" long grab bar on rear wall. - Instal full length mirror next to sink. -Handicapped sink needs to be open underneath. Remove drawers and create a sloped cover for exposed plumbing trap. - Install handicapped bathroom sign on wall latch side of door. - Provide a 34" high max table at checkout counter. - Provide Final Electrical Inspection - Install cover plates on all switches, receptacles and junction boxes. -Complete all Fire Marshal's Items 617/21 Commercial Final Inspection Not Approved Remaining Items: - Install blank plates in open circuit breakers of electrical panel box. -Complete remaining fire marshal items. 6/7/21 Commercial Final Inspection Approved -Ok to issue Certificate of Occupancy Jun 07,2021 Page(1) INSPECTION • - (COMFIN-011038-2021) Checklist Item Status Chimney/B Vent/Direct Vent Location Passed Plumbing Vent Through Roof/Roof complete Passed Doors 36 inch wLever Hand Panic Hardware, if req Passed - Install lever handle hardware on all entry and passage doors. Exits At Grade Or Platform 36 (w)x 44 (1) Passed Gas Shut-off Exposed &Regulator(18)Above Grade Passed Floor Bathroom Watertight Other Floors Okay Passed Relief Valve ,Heat Trap/Water Temp 110 deg or less Passed -Hot water tank relief valve downspouts need to be within 6"of floor. Gas Furnace Shut Off Passed HVAC Vent Terminal 10'from Lot Line&Openings Passed H/C toilet flush handle on open side Passed H/C side&rear grab bars 36" above floor Passed Jun 07,2021 Page(2) INSPECTION •R • Checklist Item Status H/C grab bar:42" side, 12"from center Passed H/C 18" minimum vertical grab bar Passed H/C vertical grab bar 39"from floor and corner Passed H/C rear grab bar 36"with 24"to open side Passed - Install 36" long grab bar on rear wall H/C mirrors 40" above floor Passed - Instal full length mirror next to sink. H/C sinks 34"above floor Passed -Handicapped sink needs to be open underneath. Remove drawers and create a sloped cover for exposed plumbing trap. Handicapped Bath/Parking Lot Signage Passed - Install handicapped bathroom sign on wall latch side of door Low flow toilet 1.3 gal/flushing cycle-showerhead/faucet Passed Universal Symbol of Access displayed -on all H/C signs Passed Public Toilet Room Handicapped Accessible Passed Handicapped Service Counters 34 inch Passed - Provide a 34" high max table at checkout counter. Jun 07,2021 Page(3) INSPECTION • ' • e Checklist Item Status Final Electrical/Flex Gas Piping Bonded Passed - Provide Final Electrical Inspection - Install cover plates on all switches, receptacles and junction boxes. Occupancy sensor lighting control Passed Bldg Num or Tenant Address on Bld or Drive Passed Bldg Access All Sides 20ft Drivable Surface Passed OK to Issue C/O Passed 5/5/21 Commercial Final Inspection Not Approved Remaining Items: - Install lever handle hardware on all entry and passage doors. - Hot water tank relief valve downspouts need to be within 6" of floor. - Install 36" long grab bar on rear wall. - Instal full length mirror next to sink. -Handicapped sink needs to be open underneath. Remove drawers and create a sloped cover for exposed plumbing trap. - Install handicapped bathroom sign on wall latch side of door. - Provide a 34" high max table at checkout counter. - Provide Final Electrical Inspection - Install cover plates'on all switches, receptacles and junction boxes. -Complete all Fire Marshal's Items 6/7/21 Commercial Final Inspection Not Approved Remaining Items: - Install blank plates in open circuit breakers of electrical panel box. - Complete remaining fire marshal items. 6/7/21 Commercial Final Inspection Approved -Ok to issue Certificate of Occupancy i i rien,John, Jun 07,2021 Page(4) MIDDLE DEPARTMENT INSPECTION AGENCY,. INC. �i le—lilaes that the electrical wiring to the, electrical equipment listed below has been examined and is approved as .J 'l being in accord with the,,National Electrical Code, applicable governmental, utility and Agency rules in effect on the date j e noted below and is issued subject to the following conditions. Owner: Mingjing Xie Date: 06/06/2013 Occupant: I Location: tj Hello Nails l. 697 Upper Glen Street Occupancy: Nail, Warren'Co:NY J- Nail.Salon ; i Applicant: siHello Nails Inc _ JUL 25 2013 � 266 Congress Street Saratoga Springs, NY 12866, } C '1 No. !f 318014151.6iA 62EL`, ;' ` i i ' j S{ Equipment: =' � . i� 11 Switches; 32 - Receptacles; 46 Fixtures; 1--20pAmp ,Receptacle Washer, 1 Vent Fan,,2 - Exit/Emergency t j Combos f k P tit-a+,l�( f c -1 'f I t 71 - �j ,v v'�- � - �.r F � _ � is>'- t •� This certificate applies to.the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only,to the use,occupancy and above and the installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a change in the use,occupancy or ownership inspection. No warranty is expressed or implied as to,the mechanical safety,effi- of the property indicated above,this certificate shall be immediately null and void. �l ciency or.fithess of the equipment for any particular purpose. This certificate shall In the event that this certificate.becomes invalid based upon the above conditions, be valid for a period of one year.from.the above noted date. Should the electrical this certificate,may be revalidated upon reinspection by Middle Department system to which this certificate applies be altered in any way,including but not limit- Inspection Agency, Inc. An application for inspection must be submitted to Middle t� ed to,the introduction of additional electrical equipment and/or the-replacement of Department.Inspection Agency, Inc. to initiate the inspection and revalidation any of the components installed as of the above noted date,this certificate shall be process. A fee will be charged for this service. S ✓ t vp 1_�U_(_SAAUy Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection requ st a ed: Queensbury Building &Code Enforcement Arrive: 1 am/ m Depart: c m m 742 Bay Road, Queensbury, NY 12804 Inspecto s Initials: a NAME: Q c I ' PERMIT LOCATION: Vfckrem S1 DATE: COMMENTS: Y N NA Chimney/°B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6°in 10'or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Balusters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"1 Treads I Vestibules For Exit doors>3000 s .ft. All Doors 36 in.w/Lever dandles/Panic Hardware, if required V Exits At Grade Or Platform 36 w x 44'(1)/Canopy(I/Canopy or Equiv. Gas Valve Shut-off Exposed&Reqgulator 18° Above Grade Floor Bathroom WaftKtight/Other Floors Okka Y� Relief Valve,Heat Trap/Water Temp.I 1 O Degrees Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Sup&for Occu ncy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %doors > 10%> 1000 sq.ft. $/Hour Corridor Doors&Closers Firewalis/Fire Separation,2 Hour, 3 Hour Complete/Fire �� Dampers/Fire Doors ✓� Ceilino Fire Stopping, 3,000 sq.it.Wood Frame �G?Q- Attic Access 30"x 20'x 30° h ,Crawl Space Access 18°x 24' Smoke Vents Or Fan, if required Elevator Operation and Si na e/Shaft Sealed Handlcapp2g Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot S' na e ` Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 in.,Checkout 36" Handicapped Ramp/Handrails Contln6ous112 in.Beyond[Bow sides Active Listening System and Sin a Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required �. c Final Survey, New Structure/Flood Plain certification,ifK As-built Septic System Layout R uired or On File �� Q Building Number or Tenant Address on Building or Driveway 4° Water Fountain or Cooler Building Access All Sides by 20'/Driveable Surface 20'wide \Aoro�;�`dklv�> Okay To Issue Temp.or Permanent CIO Okay To Issue C/C � � ��— LABuilding&Codas Forms\Building&CodesUnspecfion Fonrrs\Commercial Final Inspection ReporLdoc Revised January 7,2008 �oi �- Rough Plumbing / Insulation Inspecti n Report Office No. (518) 761-8256 Date Inspecti st ed: Queensbury Building &Code Enforcement Arrive. "a a part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's n NAME: PERM! #�: ► �-1 LOCATION: — L o INSPE T ON: i 2�=ZIL I? TYPE OF STRUCTURE: Y N N/A Rou h Plumbing /Nail Plates Plunbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout evey 100 feet l change of direction Pressure Test /Vent Air ft Mio . above hi hest connection for 15 minutes re re Test Water p Pi Air - 50 . .I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection .-L requ e Queensbury Building Code Enforcement An ive: 7" , am m n _am pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: — PE �: V — t�J LOCATION: INS CT ON: `z--'A —t 7- TYPE OF STRUCTURE: Y N N/A r - Plates �Z F --MU—Mbing Vent7varnsin Place L 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum '( Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tywek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation /Hot Water Piping Insulation Vent unheated s aces Duct work sealed ro erl / a e COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 C Rough Plumbing / Insulation Inspection RepSC Office No. 518 761-8256 347 19 Date Inspection=ree Queensbury Building &Code Enforcement Arriv 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: P MIT#: LOCATI N: INSPECT ON: PE OF STRUCTURE: N NIA --- it lat—_ 0 cE� 3 � PlumbingVent/Vents in Place �T 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent D or/Window Sealed No Insulation) uct/Hot Water Piping Insulation If r wired unheated s aces Duct work sealed properly/No duct to�e COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005,revised January 7,2008 FIRE MARSHAL'S OFFICE Town of Queensbury 742 Bay Road, Queensbury, NY 12804 "Home of Natural Beauty ... A Good. Place to Live " PLAN REVIEW Hello Nails 2012- 180 5/11/2012 The following comments are based on plan review: 1) Fire extinguisher locations to be discussed 2) Exit and EL,s to be verified with a function test.. All exit signs must be compliant with battery backup feature. 3) Locks /latches to comply w/FC1008 4) Provide a layout.of 2nd floor for review. The FM office does not have a registry for apartments on floor 2, or conducted inspections for smoke and CO detector compliance. 5) Clothes dryers must be vented directly to the exterior Note: This review is for a Nail Salon only. Any changes to a different classification or use such as food service will require a new application and review. Michael J Palmer Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.net Fire Marshal 's Office • Phone: 518-761-8206 Fax: 518-745-4437 ,ftremarshal®queensbunf.net • zvzvzu.queensbury.net RUCINSKI HALL ARCHITECTURE ���No; Ronald Richard Rucinski Ethan Peter Hall 134 Dix Avenue �JG Glens Falls NY 12801 Voice 518 741-0268 Fax 518 741-0274 FILE COPY Email ephall@nycap.rr.com Transmittal To: John O'Brien—Town of Queensbury—Code Enforcement Officer From: Ethan Hall Date: 14 December, 2020 Re: 697 Upper Glen Street—Nail Salon — HVAC Plans— Elson Qui John, Attached please find two (2) copies of signed Mechanical plans for the above referenced project location. These are to address the make-up air and exhaust requirements for the proposed nail salon at the existing facility. If there are any questions or if you need anything further please let me know. Regards, Ethan P. Hall Architect YA697 Upper Glen St Nail SalonWransmittal 14 Dec 2020.doc LANDS N/F OF JHON C. BERGERON 338/208 LOT 7 ASNALT FARMG MAP REFERENCE: MAP OF A RESURVEY OF A PORTION OF LOT 1 IVA MAE FOSTER WILLIS SUBDIVISION, OWNED BY BILLIEN CORPORATION DATED: 2/16/1967 REVISED: 4/05/1967 BY: JOHN B. VAN DUSEN MAP OF A SURVEY MADE FOR RAYMOND & ROBERT ROHNE DATE: 6/24/1985 REVISED: 7/24/1985 BY: VAN DUSEN & STEVES LANDS N/F OF BLAKE REALTY, INC. 1436/179 LOT 2 ADJOMS BULDNG lio 24 WmTE PW ,N44°11'00"E . 125.81 LOT 1 AREA 8,409.55 sq. ft. i 0.19 acres 127.10 S44°05'OG J 3.05 LANDS N/F OF THE RWK&R COMPANY, INC. 1442/127 LEGEND r = LAMP POLE O rF = IRON PIPE FOUND OIRF = IRON ROD FOUND 0 = MAN HOLE o—=o = WOOD/VINYL FENCE LINE METAL FENCE LINE POWER POLE �FAYETT gTREET � NN � W W ° ASPMALT PARKNG _ q E• "� w 4.39 Ovalt UNt N cV N 0 N cG O O j'� Scate 1'=20' L Z.�. ,S' �i „""'" ' „�"'°" °",°a, m" i1M mWwo A WW.& W A Map of a Survey made for ma-on�R � wnAnoR os m�a r� ar at m©r Ygtlt srAu ®uanox u� ' m OONLs lROm W&V ra, OF M 8OW M" S --1 Steves s K m9 ��W 'CERMIC C NEMM tM9�V V i0Q AOCOIOANEf MA1N 1f[ STEVE JACKOWSKI Land Surveyors W 11RYEY MNi P1VAR®M UIMDOffD AN Q 30 UR MR LAW VANAHML ON ADOM By aE NN Vm smic A9SO am W rRGPmm4L OLY WD 9WtY61lORl. SAO �nFloi►aoNc Ru1t E1iY GHEET I OF 1° RL' PER6011 I�MIOI 11E 511RICY i /'lllrAll� AID Queensbury, New York 12804 OR W /YW! 100 M VU Ow r/Wl^ sd1iRRR71fAL AWNf.'Y AD ►MNS WWW � WMIL AD To as mm m a as �n ma w' Town of Queeniebury, Warren County, New York - . . JAGKOWSM G1742 169 Haviland Road N0. DATE � DESCRIPTION DWG.. No. 06004 (51i 792-8474 New York Lie. No. 50135 - 30 2.06 —1-- 2 /102— 2— 2 . 4- o 0 0 0 J LL -d' 0 o t �9 b 4•-2xlo _ _. FLUSH G I P-P-EA- -FLUSH GII2UEp�, 7 /8" l3LIC-tgu� D121WALL- .8 3�4" kn tr 44 5/8rr F IRt� tt�lG /2" beYWALL 123/4 3'�i' STUDS +14" my. / i 2.Y4' WALL r- - r N 1K Sm YC'1 O.H D OO_R. I yg' WALL HT. yet I t � 13o1��t2 0 0 I i _ 6'-5.�4° CLEAu PUT <1 z xI _- q 'L hl-o 41-3 M .o, 1 All 2.-S/4 All M,o,, btuys CLG,r- I I ry! 7 HT. I NT 1 L -:W J210 I (L 28 ��. I 1 cn iM 5L111/gir N,o o iI _N a -la N @) 1 I 21' - 4 /2 x 15L OYS I I _ _ ff - io" To TILE r Q 3 j+ -� v i i _i, a! u1/� � WA'TE12 WITH MET SP m � N a 2- ' /yq 3 3'- 5 _00 M � +918" O.S.-It P05T ±.91- 5��4 K I I-85/a 2°- a N , ��ppp (1'-10 TO TILE CLG) 2Q v l� m 5 5 V4 A `16 12� 6�/8 12L 4" - poSTS ---:V,t,F, . SL 2S/4 1-0 it L t: CL.G.). ro' Iv 2'-I'/4 M 2i 4„ RpISEO Moor-, `I ra'r8 N IC,ti 0 t` 5� 9 4� Oy2 0 3o C' a. - a, i ±11 06" O.S.-k POST al-04" 4--4- POSTS i t_IIL55�B" posT-o,5, V. I.F, (VERIFi LN PIEL'V) ' r ' 2a'-to'/2,x 14'-9 10lx. CLCa, N T�� ; (8� 3 To TILE GLG) BSA - IEMMAIII NOTE :.�OV.BLi` 5�e" : T`f FE- K V1ZjWALL 1 ' P_ CEILING At4D ,Wwd 07� W/ LLS..O F l=1 E_(=H IbO/4 W Mw. .. . j�1J 1' 0Y4 I''--o%4 L `I'n - I5�3y2_ 3� 7� w _ Fxi 3�i NW +c,l 6" t' q-1-©n 311s 1,+ 4" ± �o►''� M ECHO N (CAL +l a Waxl l`ICa , FaGI AL 14' 4 K &Lo" . ftILL I N 9-1 1 gin; Q ,., 2 e !(sLoP�Ny (L 2- GLC•ar � UNISEX SfICLVCS 2- Z�l BATH �EM Et2Gt:1.IGY d- m LIGHTS__ QNCA MOVE WATM 9LE LYRICAL, c I SL6�o �� 1• I. rl. . - 3y ° 6- I ye"Y2p I! 42 3yi -...._ Jr -p ;. Z>tG 1 in,"O . C, Stu P. Wr4LL. Wl21C/p -M-r D. SILL PC.ATk IV t 8 !,`13�4 r POST 12'-4" - POST 5 -0-7 V fig. P65T _ NA(L. SALON E. L. Zell ? A x 3�DLOy2 /Si O r, ro 14 6w <TILE CEIU4G) -MPLACE . EXIST14G -S-Zx6 vsrs WITH NEW 5Y4 X 5)V' LVL paSTS Y. 4 WIQ14 JX6 WALL WlGA'P 'f RTR 2x ro 130'C'1'D M Pt-hTE �IOL°13/°.� Y..LF 8t-4�q" 'L4 V.I.F ± 10�-53�8' V,1,F. 1 NEW 2X4 STUD WALLS @ SIDES AS SHOWN W/ 31 B TOWN OF GUEENSBURY BUILDING DEPARTMENT Based on our limited examination, compliance with our comme its shall not be construed as indicating the pla;?s Ind specifications are in fuq ca:'Tx1J;anCE WO the Building Codes of New vori% ate. a O -'FILL I" 83�4" �A! J! i +0 if - nj m „-; O cb Z 10 M N C O � O CO) !J .� O LL o!f N Q �= m N N E o •°-� o ch�co0 O + C E REQUIRED ON AL L PASSAGE DOORS WHETHER INTERIOR OR EXTERIOR DOORS Fill P rOPY TOWN OF QUEENSBURY BUILDING & S PT. Reviewed By:.._JI Date:.., Z�r1 t 41, Chapter 6. Plumbing Elements and Facilities between 39 inches (990 mm) and 41 inches (1040 mm) from the rear wall. EXCEPTIONS: 1. In Type A and Type B units, the vertical grab bar component is not required. 2. In a Type B unit, when a side wall is not available for a 42-inch (1065 mm) grab bar, the sidewall grab bar shall be per- mitted to be 18 inches (455 mm) mini- mum in length, located 12 inches (305 mm) maximum from the rear wall and extending 30 inches (760 mm) minimum from the rear wall. 990 -1040 54 in E 12 max 1370 °D 305 42 min Fig. 604.5.1 Side Wall Grab Bar for Water Closet 604.5.2 Rear Wall Grab Bars. The rear wall grab bar shall be 36 inches (915 mm) minimum in length, and extend from the centerline of the water closet 12 inches (305 mm) minimum on the side closest to the wall, and 24 inches (610 mm) minimum on the transfer side. EXCEPTIONS: 1. The rear grab bar shall be permitted to be 24 inches (610 mm) minimum in length, centered on the water closet, where wall space does not permit a grab bar 36 inches' (915 mm) minimum in length due to the location of a recessed fixture adjacent to the water closet. 2. In a Type A or Type B unit, the rear grab bar shall be permitted to be 24 inches (610 mm) minimum in length, centered on the water closet, where wall space does not permit a grab bar 36 inches (915 mm) minimum in length. 3. Where an administrative authority requires flush controls for flush valves to ICC/ANSI A117.1-2003 be located in a position that conflicts with the location of the rear grab bar, that grab bar shall be permitted to be split or shifted to the open side of the toilet area. 36 min e 915 12 min 24 min L 305 610 � b LO rn� o co U �cAl 1 71 Fig. 604.5.2 Rear Wall Grab Bar for Water Closet GENERAL NOTES: A. :PP-OVIAE LOW. PROF(LE 5tLL , F#4vI,4►C 14AP_VWA4RE_ _ A N D C LOSER S 2 EKI T 'DOORS, .2, PROV19E L.EVM HANZ�L. ' �+AJZ'PWARE7 ►4T ALL L ILITE211021 V001asl P!:'tZ CODE. S. ?WViVE Ar11Z STA C(e-5 �=CR ALL ULQIER,-THC-- e-A15 'FLOM151k4a 7)PA11J PIPES, PM Cove. 4. PRov IDS F-M t=12013 ACC ►-ta RTS i Aoop H 5 pm Cove. EaUIFMM- T U&ME W H We-' A FIRST CI_A,5S C14AIZ 30 x 51 x 6o 15. - l5 P00f5LE W Act L TMLE I6 K 15x 30 3 -G DpV.6LE 511416 I � M 1455AGt �'3E� 2i x '1'i x 27 3 _ E A C-C E 560Z',( C,41i? T 14 x I4 x 22 4 _ F SIDE TJ4BLe 11 X. 15'x 20 3 COZIM4 G,4CT IG x I5x 21 . 3 _H 1EECSTTION PESe IS x 66x45 I I L7E5 k 30 K Glo x 30 � " S rEc�IN tG Iptt1 5TOOL l �+ x 18 x . C6 16. V_ dusQgMM[ CRAIP, 26 x 20 K t6 8 L PUSICEPTI©W (�AAIR 16 k 1,8 x 16 1 M CouCH 32x60x I6 2 _m Ei�JD TArIbLE' 15 x.24x .16 3 iNFOp_.,,m AT tON.__. `___SET__ F CX.15Tt WG DRAIN PIPE r �i i NI t _ Y &I _I' N t r%W FLUHrb1W _-m 6rac►c A S R=,o ` to %TK F(6AI� s N N 48 TREATMENT MECHANICALS q q q q q q q q 2'-4j" 1'-7" TYPICAL C 1 /4" = 1'-0" PEDICURE CHAIR LAYOUT 1 /4" = 1'-0" ATION (FR UP CLOSET UTILITIES EMPLOYEE II TREATMENT TOILET TREATMENT OVERALL NAIL SALO 1 /4" = V-0" I I I I PEDICURE STA IONS I WAITING AREA MANICURE STATIONS MECHANICAL VENTILATION REQUIREMENTS RECEPTION MECHANICAL VENTILATION SHALL BE PROVIDED IN ACCORDANCE WITH THE REQUIREMENTS OF NYS MECHANICAL CODE SECTION MC-403 FOR NAIL SALON WITH THE FOLLOWING REQUIREMENTS; 25 PEOPLE PER 1000 SQ. FT. OF NET OCCUPIABLE FLOOR AREA = 1,382 SQ. FT. = 36 PEOPLE FRESH AIR RATE REQUIRED = 20 CFM PER PERSON = 691 CFM FRESH AIR RATE REQUIRED = 0.12 CFM PER SQ. FT. = 166 CFM EXHAUST AIRFLOW RATE = 0.6 CFM PER SQ. FT. = 830 CFM IN ADDITION EACH MANICURE AND PEDICURE STATION SHALL BE PROVIDED WITH A SOURCE CAPTURE SYSTEM CAPABLE OF EXHAUSTING NOT LESS THAN 50 CFM PER STATION. EXHAUST INLETS SHALL BE LOCATED IN ACCORDANCE WITH SECTION MC502.20. WHERE ONE OR MORE REQUIRED SOURCE CAPTURE SYSTEMS OPERATE CONTINUOUSLY DURING OCCUPANCY, THE EXHAUST RATE FROM SUCH SYSTEMS SHALL BE PERMITTED TO BE APPLIED TO THE EXHAUST FLOW RATE REQUIRED BY TABLE MC403.3.1.1 FOR THE NAIL SALON. EXHAUST FAN EF--1 � EXHAUST FOR NAIL SALON TO BE CALCULATED IN ACCORDANCE WITH THE MECHANICAL CODE SECTION MC403.3 AS FOLLOWS; EXHAUST AIRFLOW RATE = 0.6 CFM PER SQ. FT. = 830 CFM EXHAUST FAN SHALL BE GREENHECK MODEL VG120 INLINE EXHAUST FAN INCLUDING EXTERIOR LOUVER MOUNTED NEAR THE SUSPENDED CEILING OF THE SALON ABOVE THE PEDICURE CHAIRS ON THE OUTSIDE WALL OF THE BUILDING. START UP OF THE EXHAUST FAN WILL ACTIVATE THE MAKE UP AIR UNIT. ALL EXPOSED DUCTWORK WITHIN THE SALON WILL BE UNINSULATED SPIRAL DUCT ALL EXHAUST DUCTWORK TO BE INSTALLED IN THE DUCT ENCLOSURES ON BOTH SIDES OF THE SALON ROUND DUCT AND WILL BE UNINSULATED. EACH MANICURE TABLE WILL BE CONNECTED TO THIS DUCT ABOVE THE FLOOR LEVEL. BUILDING HEAT AND ABC BUILDING HEAT AND VENTILATION WILL BE PROVIDED BY EXISTING EQUIPMENT LOCATED IN MECHANICAL ROOM GENERAL NOTES BUILDING PLANS FOR THIS PROJECT HAVE BEEN PROVIDED BY THE BUILDING OWNER. ALL HVAC WORK TO BE COORDINATED WITH THE BUILDING GENERAL CONTRACTOR. ANY CONFLICTS BETWEEN THE ACTUAL FIELD CONDITIONS AND THESE DESIGN DRAWINGS SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR, THE BUILDING OWNER AND THE MECHANICAL INSTALLER. THE MECHANICAL REQUIREMENTS FOR THE TENANT FIT -UP ARE AS DESCRIBED ON THIS DRAWING AND SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE NEW YORK STATE MECHANICAL CODE. MAU-1 (MAKE-UP AIR MAKE-UP AIR TO BE SUPPLIED IN ACCORDANCE WITH MECHANICAL CODE SECTION MC403.3 AS FOLLOWS; OCCUPANCY REQUIRES 857 CFM FRESH AIR MAKE UP AIR TO BE PROVIDED BY (3) LENNOX LIFE -BREATH MODEL LFB-267 MAX. OR EQUIVALENT. FRESH AIR TO BE TEMPERED AT THE FURNACE UNITS BY CONNECTING TO THE RETURN AIR DUCTWORK PRIOR TO BEING SUPPLIED TO THE SPACE, FOR BOTH HEAT AND AIR CONDITIONING CONDITIONS. 4 2 0 2 4 8 GRAPHIC SCALE 1 /4" = 1'-0" FILE COPY TOWN OF QUEENSBURY BUILDING DEPARTMENT Based on our limited examination, compliance with our comments shall not be construed ons rue ons c an indicating the plans and s full compliance with the Wuling Codes of New York State. LO 1 [---L_ i l-ri 1(C11-S THE SEAL BELOW IS AN ORIGINAL SEAL AND IS IN RED INK. ONLY SEALS IN RED INK SHALL BE CONSIDERED TRUE ORIGINALS No.1 DESCRIPTION I DATE REVISIONS 0 N W LL N Q 3 N w v } F Zia U=z W a oow cr w N _ 2 z aJN rUr' L i 0 Q 0 Q U_z0 3 J �oz w0F � it O N c r U L W oa 2'V 00 OOstL_ c0 r owof 0 N p NN O ww �} d'�t'�j OZ} CQt� �Z rr� 5zz UV -� Q_ > to x 0� 00 t L� lf7 N Q Z Ix _a F Q Q v co C a F- C U x D:W MCA >LLW WORK IS TO BE AS SHOWN & NOTED AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, TRADE ASSOCIATION PUBLISHED RECOMMENDATIONS AND GENERALLY ACCEPTED LOCAL CONSTRUCTION INDUSTRY PRACTICES. o 00 � O z c • 0 � P w/r/m" CAD FILE NAME ACAD\NORTHERN ENT.\SW WL SALON\HVAC-1 SCALE AS NOTED DRAWN BY DRAWING TITLE HVAC DUCTWORK & EQUIPMENT PLAN DRAWING No. HVAC-1