Loading...
2011-385 (2)son FRONT TOWN OF QUEENSBURY BUILDINC, OtARTMENT Based on our lirnifed t=xarriination, compliancy with our commpnt,,., not be construed a- indicating thr. r*lvs i specifications are in full 00MPli8r;cc- t�;r Building Codes of New Yorit, St., -AM. LF COPY - 2 0 -Ai IN LEFT re E C E 0 V E AUG 0 3 2011 T WN OF EENSBURY BUILDINQUG & CODES RIGHT k7h 24 Window & Door Schedule IF WVWV SCHEWA_E IS CHANMM VMA I%fT,AM EGRM MUST X RECALCULATED ROOM UNIT RA. QTY. CLR. 11M LIGHT VENT U-FACTEIR GARAGE 244DH3050 3' 0' x 5'0' 2 6.1 10.5 6.1 .31 GARAGE 244])H3050 (T) 3' 0' x 5'0' 1 &1 10.5 6.1 .31 GARAGE 3/0 9 LT.DOOR 3' 21/2' x 6' 10 112' 2' 20 5.6 4.1 .31 3'-6' IE 3 1 40' 18'-9' I I I I 9'-9' '-3' 10'-9' '-3' 9'-9' 5'-7' 20'-6' 3'-6' 1 GENERAL NOTES TOP OF FOUNDATION MUST BE MIN. OF 8' ABOVE GRADE GRADE MUST SLOPE 6' IN 10' FROM ALL SIDE. OF BUILDING SAFETY GLASS TO BE PROVIDED IF ONE PANE IS MORE THAN 9 SQ. FT. GLASS IS 18' OR LESS FROM FLOOR GLASS 1S WITHIN 5' OF TUB, SHOWER AND STAIRS ATTIC ACCESS 30'X22' ICE AND WATER BARRIER COVERING 24' HORIZONTALLY FROM ❑UTSIDE EDGE OF EXTERI❑R WALLS ALL STAIRS SHALL HAVE CLOSED RISERS AND BE EQUIPPED WITH HANDRAIL PLACED 34' TO 38' ABOVE N❑SING FRAMING NOTES m ALL FRAMING LUMBER MUST BE #2 AND BETTER SPF KD OR BETTER. ALL SHEATHING MUST BE APA RATED ALL STUDS, J❑IST, & RAFTERS 16' O.C. UNLESS OTHER WISE STATED. TRUSSES SPACED ACCORDING TO MANUFACTURES SPECIFICATIONS. m ALL LUMBER IN CONTACT WITH CONCRETE OR GRADE MUST BE TREATED. w ALL ❑PENINGS WIDER THAN 410' MUST BE SUPPORTED BY 2 JACK STUDS ON EACH SIDE. EXTERI❑R WALLS WILL BE 2X6 AND INTERI❑R WALLS WILL BE 2X4 UNLESS STATED ❑THERWISE. F❑UNDATI❑N NOTES * ALL CONCRETE MUST REACH 3000 PSI AT 28 DAYS FOR SLABS WALLS. m ALL F❑❑TINGS AND PIERS MUST BE ON UNDISTURBED S❑IL 48' BELOW GRADE OR BELOW LOCAL FROST DEPTH. m FOOTINGS AND PIER SIZE BASED ON 2500 PSF BARING CAPACITY. F❑UNDATI❑N MUST BE DAMP PROOFED OR WATER PROOFED TO TOP OF FOOTING. m UNLESS ❑THERWISE NOTED SLABS WILL BE 4' THICK WITH 6'X6' WELDED FABRIC, PLACED ON TOP OF 6 MIL POLY OVER 6' OF COMPACTED GRANULAR FILL. * ALL F❑❑TINGS WILL HAVE 3 PCS. OF #4 REBAR AT BOTTOM. #4 REBAR TO DOWEL FO❑TING TO WALL 72' O.C. 112' ANCHOR BOLTS MUST BE PLACED 48' O.C. AND WITH IN 12' OF ANY CORNER AND A MIN. OF 7' IN THE WALL, JND d p WIND SEISMIC DESIGN CATEGORY SUBJECT TO DAMAGE FROM WINTER DESIGN TEMP ICE SHIELD UNDERPAYMENT REQUIRED FLOOD HAZARD'S SPEED(mph) WEATHERING FROST LIN DEPTH TERMITE DECAY 90 C Severe 48' Slight to Slight to -10 24' No Moderate Moderate osb h cups 2 rows of Ice 6 water, 15 lb. t, 3a yr. shl'ngles and continuos ridge vent I proper vent 2x6 sub facsla, wood fascia with continuos vented soffit 2x6 16' o c., 3' osb, with 1 row of blocking and siding conc. frost wall, np roof to footing :ont. footing with 3 rows )f M4 rebar DESIGN LOADS FLOOR LIVE LOAD ----------- 40 PSF FLOOR DEAD LOAD ----------- 10 PSF Structure should be reviewed by a licensed engineer. All existing supports to be verified by builder. Designer is not responsible any structural calculations, or alteration made on site. All Measurements to be field verified by builder. Elevations appearance may change do to field verification. Builder responsible for all code compliance and materials being used to manufacture specif ications Do scale prints.