Loading...
2002-168 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-,Building&Codes (518)761-8256 TI CED FICATE OPOCCUPANCY Permit Numbei: P20020168 "Date Issued: .' Thursday,March-31,2005 This is;to;certify that work requested to be done as shown by Permit Number P2002016$ hasbeen completed. Tax Map Number; 523400-239-008-0001-008-000-0.000 Location: .32 BRAYTON Rd Owner: TIMOTHY COUGHTRY Applicant TIMOTHY COUGHTRY This structure may be occupied as a: By.Order of-Town Board: Residential Alteration TOWN OF QUEENSBURY Director of Building&Code`Enforcement TOWN OF QUEENSBURY 742 Bay Road,.Queensbury,NY 12804-5902 (518)761-8201 Community Development Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number-. P20020168 Application Number: A20020168 Tax Map No: 523400-239-008-0001-008-000-0000 Permission ishereby granted to: TIMOTHY COUGHTRY For property located.'at. 32 BRAYTON Rd in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot.plans and other information hereto filed and approved and in,compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: TIMOTHY COUGHTRY Residential Alteration 28,000.00 4382 WESTERN Tpke Total Value 28,000.00 ALTAMONT,NY 12009 Contractor of Builder's Name Address Electrical Inspection Agency INSPECTOR. THE 543 EASTLINE Rd BALLSTON SPA,NY.NY 12020 Plans &Specifications 2002-168: North Cabin 760 SQ FT RESIDENTIAL ALTERATION AS,PER APPLICATION $76.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday,April 17,2003 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To Queens iy; -W7 nWday,April 17,2002 Pu SIGNED BY A. for the Town of Queensbury. %forcement Director of Building Code Building Permit Application Town of Queensbury-Dept of Community Development,742 Bay Road,Queensbury,NY (518)761-8256 At A permit must be obtained before beginning construction. Permit File N(6-00 No inspection will be made until applicant has received a Fee Paid $ valid building permit. .All applicants' spaces p Fee Paid $ l application must be completed and must app a om ey I�" EDie-wed By: application form. MAR 1 5 20 S Applicant:"%i-7 G©c.--E ice.;z r 1yllAp O�CAB�0 �6. G'c cJ6 i Address: •J ,d e c�� t✓ .`;i»�✓ i Phone Phone#( � Property Location: Lot Number: / House Numbers Subdivision Name: Tax Map Number �3f�.—T R_ ❑ New Building: residence /commercial Estimated Market Value of Construction:$ E �� a Addition: residence/ commercial if an Addition,what will use of new addition be? .Alteration: residenc / commercial t ❑ No change to exterior size: residence/com'1 ❑ Other work(describe ) Check OccupaucyInformation 1" Floor 2- Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet e ly e -7 7 X❑ Two anvil dwe ling ❑ 1 Townhouse ❑ Multifamily dwelling #of units ❑ Office ❑ Mercantile ❑ Manufacturing ❑ 1 car detached garage- ❑ 2 car detached garage ❑Y 3 car detached garage 11V n nc ❑ `-1 car attached garage ❑ 2 car attached garage ❑ 3 car attached garage ❑ Storage building- commercial N3N�S sir What is the proposed height of the structure. feet inches t Will any second-hand or ungraded lumber be used? If so,for what? Type of Heating System: electric/ oil / gas wood /forced hot air/ baseboard/other: Number of.Fireplaces to be installed Number of Woodstoves to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder Plumber Mason - Electrician r Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that 1/we shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being lssued,as requested by the Zoning Administrator or Director of Building and Codes,an As Built Survey by a licensed"surveyor;drawn to scale,showing actual location of all new construction. Signature:_\ ����" _> owner,owner's agent,architect,contractor ENERGY CODE COMPLIANCE A PLICATION TOWN OF QUEENSBURY, WARREN COUNTY 9000 HEATING DEGREE DAYS 41.0 5 Compliance I ethods: PART 5 Acceptable Practice MethodQIJII 0PQ4j_ 1&2 Family Dwellings (only) f:AR--."'-Z_4'N0CqL1 y PART 6* Thermal Rating - Component Trade 1&2 Family Dwellings;. Multi-Family - Dwellings (3 stories or less) PART 4* Design by Component Performance , Commercial Buildings-Hi, Rise Residential *Requires submission of worksheets APPLICANT'S- NAME: PROPERTY LOCATION: � &AH 7VtJ PART `5 METHOD OF COMPLIANCE BY ACCEPTABLE -PRLTICE: 1 . Gross Fioorl-.Area "�%0_76osquare feet 2 . Type of: Heat Electric Oil Gas W440ther 3 . Is building mechanically cooled? Yes No 4 . Percentage of area of windows and doors Over 17% i Under 17% 5 . R-VALUES FOR INSULATION GIVEN BELOW MUST CORRESPOND TO R,LVALUES AS SHOWN ON PLANS SUBMITTED: a. Roof RI b. Exterior walls RI 1.9 C. Glazed areas RI d. Exterior do6rs R e. Floors over unheated spaces R J&& jV f. Edge of slab on grade (heated building) R g. Basement/cellar walls (above grade) h. Basement/cellar walls (below grade) R i. Heating/cooling-ducts-piping in unheated space R 6 . Service,; (domestic) hot water heating device Conforms to.'minimum efficiency-per •.code Yes No TEMPERATURE :CONTROL MAXIMUM SETTING 1400 WILL NOT BE EXCEEDED Applicant's Signature Date Phone Number INSPECTOR'S!, REMARKS: Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(5 18)761-8256 Arrive: —a!1Vj D art: am/pm Date Inspection request received: Inspector's Initials NAME. PERMIT#: 0 LO LOCATION: DATE: TYPE OF KRUCTUR Comments Y N NIA Chimney Ht./"B",Vent/Direct Vent Location Fresh Air Intake -�� �/' / 3 inch Plumb Vent through roof minimum 6" V CO Roof Complete/Exterior Finish Complete Guard 30 in.or more(a7 stairs,decks,patios Guard at stairwell at 34 in.or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum 1/2" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazin /Window in stairwells safety glazing Interior Smoke Detectors: Every level: — / Every Bedroom: Outside every bedrbom area: Inter Connected: — / Battery backup: Carbon Monoxide Detector Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Seated properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"accqss, I sq. ft.-150 sq.ft.vents Building No./Addrjsslyisi le fr_qim road Final Electrical t) Site Plan /Variance r6quited Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/0[Temporary/Permanent L:1PamW\I3uiIdinjz&Codes\Inspection Forms\Res.Final Insp.form 2.docLast printed 2/12/04 Residential Final Inspection Office No. (5 T8)761-8256 Date Inspection request received: — Queensbury Building&Code Enforcement Arrive: am/p epart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials; NAME: An, ft, PERMIT#: LOCATION: r4 DATE: TYPE OF STRUCTURE: e s Y -N N/A ChimneyHt./"B"Vent/Direct Vent Locatio Fresh Air Intake 44 t ,? — _76 7� 3 inch Plumb Vent through roof /�_ •� Com' Roof Complete Guard 30 in.or,mo're @ stairs,decks,patios Guard at stairwell at 34 in. or more —- -- Guard at deck,porches 36 in.or more -- Exterior Finish Complete Interior/Exterior Railiri s 34 in.to 38 in. �� Platform at all exterior doors ! ,, Interior Handrails stairs 2 or more risers U' vW Grade away from foundation 6 in.with 10 ft. lb�t-�q (W) Handrail Termination at Newell Post or Wall C.pi 1 8 inch clearance to sill plate UU Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30,ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating -Low water shutoff boiler Relief Valve(s)installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight ` -Safety glazing Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: ' / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures / Foundation insulation i L .`- (j Floor truss,draft stopping finished basement 1,000 sf � Emergency egress below grade Basement stairs closed rise>4 inches � � 3/4 hour fire door/door closer Garage fire roofm ' Duct work Sealed properly ��irryl Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces IS"x 24"access, I s ,ft.-150 s .ft.vents I3uildin No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification,if required Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C/,O(Cert. Of Occupancy) Okay to issue Permanent C/O(Cert:Of Occupancy) L:iSueHeming%vay�Building.Codes.Inspectioii.FORMSIRes.Final Insp.form 2.doc edited January 28,2003 office Use qcv GENERAL INSPECTION REPORT �� ✓ S t, , Inspector: Town of Queensbury � , Ready at time: ' Dept. of Community Development Request received. Meet:�&Building Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE 3tO am/pm: DEPART am/pm Notes: (518) 761-8256 : Inspector's Initials J NAME: PERMIT# � LOCATION: SPECT ON_(date): 04— 0 TYPE OF STRUCTURE: .RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is respons' le r providing protection fro freezi g for 48 hours following th place ent of the concrete. Materials for this purpose on it Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing 1 Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place f Rough Plumbing Heating Rough-hi Insulation Foundation Walls Interior: R- Foundation Walls Exterior R- Floors R Walls R- Ceiling R- Duct work or piping in Bated spaces R- Pro er Vent,Attic V aming G.. Jack Studs/Headers t Bracing/Bridging /USS��� Joist Hangers C//`t Jack Posts/Main Beam �� Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping L:\SueHemingway\Building.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doe Office Use GENERAL, INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: ' Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, AT 12804 ARRIVE /X/d am/pm: DEPART am/pm Notes: (518) 761-8256 Inspector's Initials -fo - big NAME: PERMIT# LOCATION: INSPECT ON(date): � T TYPE OF STRUCTURE: LAY )n RECHECK. N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place, Foundation/D amppro offing Backfill Approval Plumbing Under Slab Plumbin,g-VentlVents in Place ' Rough, lumbing He g Rough-In ulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R Walls R Ceiling R- Duct work or piping in unheated spaces R- PrWi6r Vent,Attic Vent Al) 6G' ranting `t' Jack Studs/Headers AracingBridging , •/ f ,� Joist Hangers J`i�� Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour ' Penetration Sealed Fire Wall 2,3,4 hour Firestopping L:\SueHemingway\Building.Codes.Inspection.FORMS\GENERAI,INSPECTION REPORT.doc Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, AT 12804 ARR1VEZ6',4't1 am/pm: DEPART am/pm Notes: (518) 761-8256 Inspector's Initials NAME: PERMIT# ..Cg 0 LOCATION: INSPECT ON(date): TYPE OF STRUCTURE RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours f6l1owi the p cement of the concrete. Materials for this purp se on site site Foundation/Wallpour— Reinforcement in P Pce Foundation/Dampproo g Backfill Approval Plumbing Under S 111 b Plumbing Vent/Ven lace�_�!� Rough Plumbing Heating Rough-In_ Insulation Foundation Walls'ntcn r R- Foundation Walls Exten r R- Floors tR- Walls Ceiling Duct work or piping in cated,spaces R- 4 Pr er Vent,Attic Vent im /ami7ng T., Jack Studs/Headers g Bracing/Bridgin lae-1, v4 11-19 - Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour 4dw "api fr ear/ Firestoppmg_ L:\SueHemingway\Building.Codes.Inspection.FORrVIS\GENERAI,INSPECTION 1EPORT.do, PAVEMENT 00 1�y� s R ® LOT NUMSER MC4 MAP ROIRENCE #1 t l .i is / ti `'�' Lands-N/P L 823 P t58 shed atone &concrete watt l\ 6 shed jp RQ ' L215 P. one Tax ID #11-1-20I-oo an 34 3' g Parcel Area � b°z1` 'h cellar 1 18,2671 s.f. ama Camp' .rood �.. 0.42f acres o, deck / 17. ' / I o / / ... ... aL J 1/2 stframe covered ory _...�,. porCh .- .193.79 stone hr,..- ... w �.�..- IPF f a P.Qa LX6 P.139 . Lands N/F 1 ;' Weber _ !