Loading...
Site PlansGeorge 4G5'± ALONG THE 5H0E-E a �\G� 320. f. COVERED `•` BOAT LIFT \° DOCK �-- W � ", J\ V-2B OOP.:\ \ �. Iw Q. u \ ` l PROPOSED 52' SETBACK FOR STORMWATER DEVICE (GRASS PLANTER #7), REQUIRES A 48' VARIANCE George GRAPHIC SCALE 20 15 10 5 0 20 40 80 (IN FEET) 1 INCH = 20 FT. PROPOSED 69' SETBACK FOR V-2D STORMWATER DEVICE (GRASS PLANTER #9), REQUIRES A 31' VARIANCE Dock Deck 777 ---7 EP 50' SHORELINE 9'± to Shore Dock Dock FF- 325.00 -00 I 325 if l I /< 11 \ IN, 1 \ \ IN, \ l IIS4' SI' 'Typ \ \ La�a" I Q \\14600.5± S Feet 0.34± Ac as m -- IRF 10'*- to Shore �s 327.00 W \\0 N 0 TICK YAR���� r 0 Lands NIF of Panels Golde 8:1306 P218 226.1 5-5-15 a - RECEIVED J U N 16 2022 TOWN OF QUEENSBURY ZONING OFFICE WE7LAND AREA 1,019f SO. FT. F�! PF\ LANDS N/F OF O'KEEFE PROPOSED 10.0 FT. WETLAND SETBACK REQUIRES A 40.0 FT. AREA VARIANCE PROPOSED 57' SETBACK FOR STORMWATER DEVICE (GRASS PLANTER #8), V-2C REQUIRES A 43' VARIANCE WETLAND CaVTINUES 1Nv 322.50 \L ;;?!\ PROPOSED 74' SETBACK FOR j STORMWATER DEVICE (GRASS DEPRESSION #2), REQUIRES A 26' VARIANCE A;f Bench Mark RR 5plke In UPNG3 Elev. = 328. 4' V-2A 100' INFILTRATION DEVICE BUFFER SITE LOCATION MAP SCALE: 1" = 2000' SITE STATISTICS (MAIN HOUSE) EXISTING ZONING PARCEL AREA PROPOSED LAND USE BUILDING AREA BUILDING HEIGHT WR ZONE REQUIRED STANDARDS PERMEABILITY SETBACKS SHORELINE FRONT SIDE REAR EXISTING PERMEABILITY SETBACKS SHORELINE FRONT SIDE (WEST) REAR (EAST) PROPOSED PERMEABILITY SETBACKS SHORELINE FRONT SIDE (WEST) SIDE (EAST) WATER SERVICE SANITARY SERVICE **AREA VARIANCE GRANTED BY ZBA WR WATERFRONT RESIDENTIAL .91 ACRES (39,487 SF) RESIDENTIAL 8,670 SF 28.0 FEET 75% 50 FT 30 FT 20 FT 30 FT 79.8% 19.6 FT 53.6 FT 26.4 FT 63.2 FT 77.9% 46 FT & 35.0 FT** 36.0 FT 0 FT 20.0 FT PRIVATE DRAW FROM LAKE ON —SITE HOLDING TANK ON 3/23/2022 PROPOSED BUILDING AREAS FIRST FLOOR (INC. GARAGE) 5,060 SF FIRST FLOOR PORTE COCHERE 376 SF SECOND FLOOR 2,834 SF COVERED WALKWAY 400 SF TOTAL 8,670 SF LOT AREA 39,487 SF FLOOR AREA RATIO (22% MAX) 22% **AREA VARIANCE GRANTED BY ZBA ON 3/23/2022 VARIANCE TABLE ZONING REGULATION REQUIRED PROPOSED VARIANCE REQUESTED SHORELINE (WETLAND) SETBACK 50 FT 10 FT 40 FT INFILTRATION DEVICE SETBACK 100 FT 74 FT 26 FT INFILTRATION DEVICE SETBACK 100 FT 52 FT 48 FT INFILTRATION DEVICE SETBACK 100 FT 57 FT 43 FT INFILTRATION DEVICE SETBACK 100 FT 69 FT 31 FT OTHER VARIANCES GRANTED BY ZBA ON 3/23/2022 N N T.. N � O N LOL �p } N Q O:) Z Q 0 � w � F J W cw VG a a. z� Z W< W Y W O } UJ � w Q m Z U) U J Q W H \ °- YW� O Q Quo aL O Z ZWLij z QZ� m Q z> o ��� DRAWN BY EHK CHECK BY Gy EDP PROJECT NUMBER XXX 7NE ALTERATION OF 7NESE DOCUMENTS IN ANY WAY, UNLESS DONE UNDER THE DIRECT SUPERVISION OF A CDIR'ARABL£ PROFESSIONAL. (TIE.) ENGNEFR FO4 AN ENO'NEER, LANDSCAPE ARCTR7ECT FOR A LANDSCAPE ARCW7ECT OR SIMYEM FOR A SURY£Y IS A VIOLATION OF THE NEW YORK STATE EDUCA71ON LAW ANDIM REGULATIONS AND /S A Cuss A' MLSOEMEANO4 REVISION I DATE BY' ADD WETLAND INFORMATION 5-23-22 GV 1"=20' SHEET TITLE: VARIANCE PLAN H EET: 1 of 1 f Ln A LTD LU LU 0 Cu CD 39 3 A W IL 1 z J 0_ W U z ¢ i LJ LL d a Iv A A I In ti w 3 m 2 i 0 3 Y K o_ r ¢ Da r m 0 z w W C3 z W ¢ 3 IY MAIN HOUSE WEST RESIDENCE APPLICANT/ OWNER: BR TT AND PAM LA WEST 106 BAY PARKWAY TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK JANUARY 18,2022 SITE LOCATION MAP SCALE: 1" = 2000' SITE STATISTICS (MAIN HOUSE) EXISTING ZONING WR WATERFRONT RESIDENTIAL PARCEL AREA .91 ACRES (39,487 SF) PROPOSED LAND USE RESIDENTIAL BUILDING AREA 8,670 SF BUILDING HEIGHT 28.0 FEET WR ZONE REQUIRED STANDARDS PERMEABILITY 75% SETBACKS SHORELINE 50 FT FRONT 30 FT SIDE 20 FT REAR 30 FT EXISTING PERMEABILITY 79.8% SETBACKS SHORELINE 19.6 FT FRONT 53.6 FT SIDE (WEST) 26.4 FT REAR (EAST) 63.2 FT PROPOSED PERMEABILITY 77.9% SETBACKS SHORELINE 46 FT & 35.0 FT FRONT 36.0 FT SIDE (WEST) 0 FT SIDE (EAST) 20.0 FT WATER SERVICE PRIVATE DRAW FROM LAKE SANITARY SERVICE ON -SITE HOLDING TANK PROPOSED BUILDING AREAS FIRST FLOOR (INC. GARAGE) 5,060 SF FIRST FLOOR PORTE COCHERE 376 SF SECOND FLOOR 2,834 SF COVERED WALKWAY 400 SF TOTAL 8,670 SF LOT AREA 39,487 SF FLOOR AREA RATIO (22% MAX) 22% APPLICANT NAME AND ADDRESS: BRETT AND PAMELA WEST 4651 GULF SHORE BLVD N UNIT 104 NAPLES FL 34103 RECEIVED J U N 10 2022 TOWN OF QUEENSBURY ZONING OFFICE SHEET INDEX: SHEET SHEET TITLE NUMBER 1 COVER SHEET 2 EXISTING CONDITIONS 3 REMOVALS PLAN 4 SITE PLAN 5 GRADING AND UTILITY PLAN 6 PLANTING PLAN 7 EROSION AND SEDIMENT CONTROL PLAN 8 SITE DETAILS NYSDEC CONSTRUCTION CERTIFICATION NOTE: THE CONSTRUCTION OF THE SANITARY SEWERS DEPICTED ON THESE PLANS SHALL BE UNDER THE SUPERVISION OF A PERSON OR FIRM QUALIFIED TO PRACTICE PROFESSIONAL ENGINEERING IN THE STATE OF NEW YORK UNDER THE EDUCATION LAW OF THE STATE OF NEW YORK. WITHIN THIRTY (30) DAY FOLLOWING THE COMPLETION OF THEE CONSTRUCTION THE ENGINEER SHALL CERTIFY TO THE DEPARTMENT OF ENVIRONMENTAL CONSERVATION AND TO THE OWNER THAT THE CONSTRUCTED FACILITIES HAVE BEEN CONSTRUCTED UNDER THE SUPERVISION AND THE WORK HAS BEEN FULLY COMPLETED IN ACCORDANCE WITH THE APPROVED ENGINEERING REPORT AND PLANS. THE PROJECT DEVELOPER MUST RECEIVE WRITTEN ACCEPTANCE OF SUCH CERTIFICATION FROM THE DEPARTMENT PRIOR TO PLACING THE FACILITIES IN SERVICE. RECORD OF SUBMITTALS DATE BY 1 , N C1 �w� ■ 9 Z N M Ti C e f N N T- N ' O 1 N LID �i co } N Q za o� a W w � J wW u� Z� w� Z U) 00 0 } wZ �W mZ W�Q U }cn} Q W J W I- � O Q Q0o _ ZWW a a LL >-0W < _ >Z z R cQ G > � 0 0 Q � H Y EHK Y rDR GV JECT NUMBER XXX RAMON OF THESE DOCUMNIS IN ANY WAY,DONE UNDER INE DIRECT SUPM14MON OF A COWARABLE M FESSMAL. (LE.) ENGINEER FOR AN ENGINEER, LANDSCAPE AROMIECT FOR A L.WOSCAPE ARL7N7ECT OR SURVEYOR FOR A SURVEYOR IS A NOL.AALAN OF 7NE NEW YURK STATE EDUCAR N/ LAW AND/OR REGULATIONS AND IS A !LASS A' ADSDE7MEANOR. REVISION DATE BY ADD WETLAND INFORMATION 5-23-22 GV � I SCALE: AS NOTED SHEET TITLE: COVER SHEET SHEET: 1 of 8 (U IT N CM N LU fU CD LU Lb 0 m V) w 3 I H U I 0 w w Ln Li a, 0 a i L3 3 a I n i rn w 3 m 0 0 3 Y Q d r Q Pa z w w ZD C5 z w 3 LY DOCK SOIL DATA: 4!�- 0 THE FOLLOWING TEST PITS WERE PERFORMED ON DECEMBER 3, 2021 AND WERE OBSERVED BY ENVIRONMENTAL DESIGN PARTNERSHIP, LLP: TP41 (ELEV.=324.50) 0" — 9" TOP SOIL, ROOTS 9" — 21 " FINE LOAMY SAND, FREE, BROWN 21" — 32" FINE SILTY LOAM WET, GRA Y WATER ® 24" (ELEV.=320.50) TP�2 (ELEV.=323.75) 0" — 6" TOP SOIL 6" — 28 FINE SILTY LOAM, BROWN 28" — 41 " FINE SILTY CLAY, WET, BROWN MODELING ® 28" (ELEV.=321.42) WA TER ® 36" TPJQ (ELEV.=323.00) 0" — 4" TOP SOIL 4" — 24" FINE LOAMY SAND, BROWN, FREEABLE 24" — 46" FINE LOAMY CLAY, GRA Y, WET MODELING ® 30" (ELEV.=320.50) WATER ® 42" TP�4 (ELEV.=326.50) 0" — 6" TOP SOIL 6" — 32 FINE LOAMY SAND, TAN, FREEABLE 32 — 51" FINE SILTY LOAM, GRAY, WET MODELING ® 36" (ELEV.=323.50) TPJ5 (ELEV.=326.50) 0" — 2" TOP SOIL 2" — 3" PAVEMENT REMAINS 3" — 27" MEDIUM SAND, TAN COBBLES THROUGHOUT.5"-2" 27" — 58" FINE SILTY LOAM, GRA Y, WET WATER ® 54" (ELEV.=322.00) THE FOLLOWING INFILTRATION TESTS WERE PERFORMED ON DECEMBER 3, 2021 AND WERE OBSERVED BY ENVIRONMENTAL DESIGN PARTNERSHIP, LLP: LW SOIL STABILIZATION RATE=21 IN./ HR. L&2 SOIL STABILIZATION RATE=5 IN./ HR. I T#-3 SOIL STABILIZATION RATE=55 IN./ HR. Lake George 465'± ALONG THE SHORE 51 0. — P \� z � cove 3 RED TP # ti BOAT LIFT �'...... ti ✓ � I L AREA PATIO w� 39, 487+ sq. ft. 0.91_ acres 24, 0 J 0 METAL \ \ \ _ In COVER ` CO) ca \ IL I \ L- I Lake George 9'# to Shore 101t to Shore Lands M/F of Pamela Golde B:1306 P218 22G. 1 5-5-15 WETLAND AREA — 1,019t SO, FT. GRAPHIC SCALE 20 15 10 5 0 20 40 (IN FEET) 1 INCH = 20 FT. Lands NI F of Brett West & Pamela Wes B:3009 P:38 22G. 15-1-17 80 4 if r N O N � O N L0 O �p } N N Q O� Z Q 0 � V/ G w x J uj w V� Zo w Z < C m o w� } Z �w w U }�z Q U J W aY w 5 O Q Q0o w z ZWz a O Z� 2 3: co0Q O O DRAWN BY EHK CHECK BY GV EDP PROJECT NUMBER XXX THE ALTERATION OF THESE DOCUYIENTS IN ANY WAY, UNLESS DOME UNDER THE DIRECT SUPERVISION OF A COMMARABLE PRG'ESSgVAL. (LE) ENONEER FOR AN ENONEER, LANDSCAPE ARCINTECT FOR A LANDSCAPE ARCHITECT OR SURVEYOR FOR A R RVEYOR IS A VIUCA770N OF THE NEW YOW STATE EDUCATION LAW MAID/014 REM"77ONS AND IS A MASS A' JgSJEME Uyp4 REVISION DATE BY ADD WETLAND INFORMATION 5-23-22 GV i c c c c c c 1 L L ' 1 a C �l G f L J L \\ j to SCALE: ill 20' L' F U v 3 a SHEET TITLE: EXISTING i a CONDITIONS 3 a a a PC SHEET: V, z w 2of8 w QJ z w a 3 rY DOCK Ab George 7 20 \Nr SHED TO BE REMOVED, CONCRETE PADS TO BE LEFT IN PLACE. coN77NUES CONTRACTOR TO USE CAUTION AND P�p(� NOT ALLOW DERBIES OR 4G51± ALONG THE 5HORE SEDIMENT TO ENTER WETLAND. WETLAND AREA a 1,019t SQ. FT ���� F o 7zo/ �" LANDS N/P OF O'KEEFE 14 3 COVERED ( `-` '\ \ / `• pAT LIFT \ REMOVE EXISTING PAVEMENT, MISC. CONCRETE AND DEMOUSH EXISTING BUILDINGS. ALL DEBRIS / \ , \ \✓r \ , ._\_ INV. 4 PVC zF SHALL BE DISPOSED OF OFFSITE ✓' \f \ \ter' \ / \ ` \� `,i `,; �✓ \ \ \ iirT PVC ,\ LL �\ Ia \ r' \✓\-� \ r \,r J \ po \ METAL COVER \ / .\ \ / , ✓'✓' \ r r a :\ x ✓ \ \ ��\. r % - ✓v /Y\ WETLAND v' r \. \ r , \ r' , \ \ k CONTINUES ,,, < 4€. lLJ ` �s.:Y'�' '.r^' \ ! \ \,yam' \ •' \ / \ \. ,,,.,. ,,.. \ .. �\ \r'' ` ✓ \:r fir' �✓ \ \,r - ,✓ '\ ✓ \ / \ j ! \.! / \ 2 \ \ \ \ / uu \ . Y\ , v \ \ \ , \ \ INV 322.50 7. \ \ter \\,/ \ .✓\,•' \ v `\r'\.sQf�-i `' \ '\/✓ / r \ IP� r -Sk ter•. \- ec�,\ \r \,.. .\✓ \ r .; \ / \ / ✓ \/ \vim \ ✓ \\/ A� Lake \4 Dock / /,, r ,r rater 41 r George Utilityp"' CI 9' t to Shore Bench Mark RR Spike In UP NG 3 Dock I �" L t 5ITW Deck Doc l \ Are)@ � \I 14600.5t Feet I <y 0.34t Ackes \ \� l � ` Lands N/F of 1 � 51% Pamela Golde I _ B:1306 P218 A N\ ` `� _„iN ✓ ;, 226.15-5-15 t � 101± to Shore INV 323.92 Lands N/F of Brett West & Pamela B:3009 P:38 22G.15-1-17 REMOVALS PLAN LEGEND: DENOTES EXISTING PAVEMENT, MISC. '...•••• 1 CONCRETE, SIGNAGE, CURBING, AND BUILDING TO BE REMOVED. DENOTES UNDERGROUND FEATURE TO BE REMOVED GRAPHIC SCALE 20 15 10 5 0 20 40 80 (IN FEET) 1 INCH = 20 FT. N N N ,o N LO (6 } N Q 0 ZQ rA v/ >W J WW u� z� Z Lu < � Y � W � co O Lu� z Dw co z W U } U) cn < z Zt WZ Q Q QaO 2 U) a U. z ?Wz azO � Q � CO oQ o 0 ��- 3: DRAWN BY EHK CHECK BY GV EDP PROJECT NUMBER XXX THE AL7ERAMW OF nIESE DOCUAAEN7S AN ANY WAY. UNLESS DONE UNDER 77E DIRECT SUPERWWON OF A COMPARABLE PROFESSIONAL, (1.E.) ENGINEER FOR AN ENGINEER, LANDSCAPE ARCM7ECT FOR A LANDSCAPE ARCM7ECT OR SURVEYOR FOR A SURVEYOR, IS A WMA71ON OF ME NEW YORK STALE EDUC4770N LAW AND/OR REGULA77ONS AND IS A GI.ASS A' ANSDENEANOR REVISION DATE BY ADD WETUWD INFORMATION I 5-23-22 GV f 0 OD (U (U o CU N 0 C 3 7 3 w 3 I f w I CD 0 / w w / VI c a a SCALE: a 1"=20' A LO 3 a I to i w 3 00 SHEET TITLE: 0 �D 0 REMOVALS PLAN r a o_ r w SHEET: PCI 3of8 C6 z w w C3 z w Of a 3 rY George 4G51± ALONG THE 511ORE _ _ a LIGHTING NOTE: Pa �� ALL LIGHTING TO BE DOWN / CAST RESIDENTIAL LIGHTING FIXTURES. ROOF LEADER (TYP.) COVERED :ice.` A ` BOAT LIFT DOCK F : .-d rr' 50' SHORELINE ' { =` �'1" &Ul 31 •�VF \ Jo 325.00 EXISTING TREES AND SHRUBS ALONG J SHORELINE TO REMAIN r� , I ( N CD Lake Dock \ 326 '17 George � 410 1SF R?;,` 9, t to Shore I \ \ N, 321•� IN, 102 Dock :Pr .,:.,•.* :=:::'}}`i Deck GRAPHIC SCALE 20 15 10 5 O 20 40 80 (IN FEET) 1 INCH = 20 FT. Dock 5Lg Typ. Lld IN J \ Are`a \I 14600.5± S4Fee \ 0. 34t Act es \ 11\ \ 0 60 i Val 101*- to Shore 7 20 WETLAND CONTINUES ALL DRIVEWAYS, WALKS AND - WETLAND AREA g 1,019t SO. FT. PATIOS TO BE CONSTRUCTED PERMEABLE CONCRETE/BRICK PAVERS ND5 N/F OF O'KEEFE PROPOSED 10 FT WETLAND SETBACK REQUIRES A 40 FT AREA VARIANCE .Y} X'00� YARSm jky' — S� _ —F-== Mht. P, \ %N, i O I�r __�T 11 O Lands N/F of Panels Golde 8:1306 P218 22G.15-5-15 PROPOSED HOLDING TANKS WETLAND CONTINUES TYPICAL GRASS DEPRESSION AREA � 1N1�322.80 PROPOSED 20 FT. WIDE ACCESS EASEMENT I Bench Mark RR 5plke In UP NG 3 Elev. = 328. 4' PROPOSED 410 SF LOT LINE ADJUSTMENT IPF1 o 1 SITE LOCATION MAP SCALE: 1 " = 2000' SITE STATISTICS (MAIN HOUSE) EXISTING ZONING WR WATERFRONT RESIDENTIAL PARCEL AREA .91 ACRES (39,487 SF) PROPOSED LAND USE RESIDENTIAL BUILDING AREA 8,670 SF BUILDING HEIGHT 28.0 FEET WR ZONE REQUIRED STANDARDS PERMEABILITY 75% SETBACKS SHORELINE 50 FT FRONT 30 FT SIDE 20 FT REAR 30 FT EXISTING PERMEABILITY 79.8% SETBACKS SHORELINE 19.6 FT FRONT 53.6 FT SIDE (WEST) 26.4 FT REAR (EAST) 63.2 FT PROPOSED PERMEABILITY 77.9% SETBACKS SHORELINE (LAKE) 46 FT & 35.0 FT SHORELINE (WETLAND) 10 FT FRONT 36.0 FT SIDE (WEST) 0 FT SIDE (EAST) 20.0 FT WATER SERVICE PRIVATE DRAW FROM LAKE SANITARY SERVICE ON —SITE HOLDING TANK PROPOSED BUILDING AREAS FIRST FLOOR (INC. GARAGE) 5,060 SF FIRST FLOOR PORTE COCHERE 376 SF SECOND FLOOR 2,834 SF COVERED WALKWAY 400 SF TOTAL 8,670 SF LOT AREA 39,487 SF FLOOR AREA RATIO (22% MAX) 22% VARIANCE TABLE ZONING REGULAMON REQUIRED PROPOSED VARIANCE REQUESTED SHORELINE (WETLAND) SETBACK 50 FT 10 FT 40 FT INFILTRATION DEVICE SETBACK 100 FT 74 FT 26 FT INFILTRATION DEVICE SETBACK 100 FT 52 FT 48 FT INFILTRATION DEVICE SETBACK 100 FT 57 FT 43 FT INFILTRATION DEVICE SETBACK 100 FT 69 FT 31 FT OTHER VARIANCES GRANTED BY ZBA ON 3/23/2022 N N N o N T (0 } N Q ZQ Q >W X > I— J Lu ui VG � Z z Q U O } Lu } � W Q m z W Q U J W 0 Yw � O = Q Qo o o (. LL z uj W Q0w — Q z m�� Or o 0 Q r DRAWN BY EHK CHECK BY GV EDP PROJECT NUMBER XXX Of ALTERATION OF DREW DOCUMENTS IN ANY WA1 (#LESS DONE UNDER THE DIRECT SUPERNS'ON OF , COMPARABLE PROFESSIONAL, (LE) ENGNEER FOR AI EN00NEER, LANDSCAPE ARCHITECT FOR A LANDSCAPI ARCHITECT OR SURWYUR FOR A SVRYEYOR, IS A NOLATIM OF THE NEW YLXIK STATE EDUCATION LAW AND/01 REGIAA77ONS AND IS A CLASS A' ABSDENEANOR. REVISION DATE I B) ADD WETLAND INFORMATION 5-23-22 1 GV LE: 1"=20' EET TITLE: IS H EET: SITE PLAN v v m LU LU 0 LU as 0 3 m w 3 I z J 0_ 1 In 0 w w Ln N d 0 Iv A L3 I V) w 3 co 0 I 0 } a 3 ]C Of a 0- r as Of mo w N z w w Z) L3 z w 3 Of DpCK Lake George PROPOSED 4" SDR-35 INV. OUT=321.35' WITH RIP RAP 4651± ALONG THE 5MORE .7777 FU D 4" SDR535 5.4'x5.4' STONE RESERVOIR 1" HDPEWATER SERVICE / EXTEND 4' DOWN MINIMUM PROPOSED 4" SDR-35 WITH CONNECTION TO OR BELOW FROST LAYER UNDER DRAIN LAKE WATER ry, WHICHEVER IS GREATER INV.=321.50' eaJ RED COVE .� T GRASS PLANTER #1 BOAT LIB - (SEE DETAIL) •ate 2.4'x2.4' STONE RESERVOIR �• _� EXTEND 4' DOWN MINIMUM �•_•�•� OR BELOW FROST LAYER �•�•� WHICHEVER IS GREATER o/ ►W n-�•• •s• O GRASS PLANTER I7° 0O \ J e €K L \` 9 } W \ `\ PERMEABLE PAVER . PATIO y� � 3 4. 3.4'x3.4' STONE RESERVOIR EXTEND 4' DOWN MINIMUM OR BELOW FROST LAYER �. WHICHEVER IS GREATER �-' [GRASS \\ PLANTER #2 I (SEE DETAIL) 1 I I DRIP EDGES #1 AND #2 (SEE DETAIL). 1 LakeBOTTOM OF STONE=324 08' PERMEABLE PAVER PATIO GRASS PLANTER #4 (SEE DETAIL) ARIANCE REQUEST THIS PLAN AND SUPPORTING APPLICATION TO THE TOWN OF QUEENSBURY BOARD OF HEALTH PROVIDES THE DOCUMENTATION FOR THE REQUEST OF A VARIANCE FROM THE ORDINANCE REQUIREMENTS OF CHAPTER 136: SEWERS AND SEWAGE DISPOSAL. V-1: REQUEST FOR THE USE OF HOLDING TANKS SECTION 136-11 NOTES: 2� 4 BEDROOM HOUSE REQUIRES APPROXIMATE LOCATION OF HOLDING TANK CAPACITY OF P NEIGHBORING SEPTIC TANK 4,000 GALLONS. AND PUMP TANK EXISTING TREES AND LOWER WETLAND VEGETATION TO REMAIN coNnNUE � OVERFLOW WIER EL=323 40 o\ WETLAND AREA 1, 019f SQ. FT. LOWEST EXISTING ADJACENT GRADE=323.00 es HIGHEST POINT OF STRUCTURE=361.00 LIK : STRUCTURE HEIGHT=38' APPROXIMATE LOCATION OF ,� E •P FE NEIGHBORING HOUSE 0 GRASS PLANTER #3 (SEE DETAIL) ' 4 3.3'x3.3' STONE RESERVOIR EXTEND 4' DOWN MINIMUM POSSIBLE LOCATION OF OR BELOW FROST LAYER WHICHEVER IS GREATER NEIGHBORING LEACH FIELD GRASS PLANTER #8 (SEE DETAIL) -?, r GRASS PLANTER #9 ' • .` ,r; r (SEE DETAIL) FG 1.25' WIDE x 1.25' DEEP STONE DRIP EDGE PROPOSED 4" SDR-35 UNDER DRAIN INV.=321.50' W£TLAN GRASS DEPRESSION #1 CON S \ 1—322.50 \ AT 4 FT MIN \ \ .50 EXTEND A 2' WIDE x 7.25' LONG c SECTION OF STONE DOWN A MINIMUM X 2-2,000 GAL OF 4' BELOW GRADE, OR BELOW FROST, \ \ CONCRETE HOLDING WHICHEVER IS GREATER 1 ) I s26 " TANK, SEE DETAIL OVERFLOW WIER 4.2'x4.2' STONE RESERVOIR EL EXTEND 4' DOWN MINIMUMGeorgeOR BELOW FROST LAYER ` yr- tN� WHICHEVER IS GREATER \\ r I 1 GRASS DEPRESSION #2 I — � 4.2'x4.2' STONE RESERVOIR EXTEND 4' DOWN MINIMUM OR BELOW FROST LAYER WHICHEVER IS GREATER PERMEABLE PAVER 9' t to Shore \ \ \ �� 32'�.QO DRIVEWAY Bench Mark I rill RR 5p1ke In UPNG3 Elev. = 325. 4' DockIFF i wi"':F: iO Tyt 1 � \ Deck sstleTyp. Ll Dock' \ \ IT#3 \I 14600.5± S4Feet \ 0.34± Ackes 'd2 \\ \ \> o \ \ ..... Lands N/F of 1 / Pamela Golde MY B:1306 P218 W N _ao fi 226. 1 5-5- 1 5 IRF 10't to Shore INV . z Is- N �- N ' O N LO r � N Q O� z z 0 � a. U W x J w W Z� z W� Y o m Lu z Dw Z W 0° U QU)� z D 3Wz 0 Q Qo0 2 � a IJ_ }oz Z Lu z Q z0� Q (0 0 O F, - 3: DRAWN BY EHK CHECK BY GV EDP PROJECT NUMBER XXX 7W ALTERATION OF THESE DOCUMENTS M ANY WAY UNLESS DONE UNDER THE DIRECT SUPERNSION OF A COMPARABLE PROFESSIONAL. (/.E.) ENGINEER FOR AN ENGINEER, LANDSCAPE ARCN7ECT FOP A LANDSCAPE ARCHITECT OR SURVEYOR FOR A SURI£Y02 IS A NttA7701J OF 7HE NEW YORK STATE EDUCATION LAW AND/OR R£GI/UDONS AND IS A CLASS A' WSOEMEANO . REVISION DATE BY ADD WETLAND INFORMATION 5-23-22 GV ill =20' HEET TITLE: GRADING AND UTILITY PLAN GRAPHIC SCALE 20 15 10 5 0 20 40 80 (IN FEET) 1 INCH = 20 FT. H EET: 5of8 I I"') z c KEY COMMON BOTANICAL SIZE NO. REMARKS An SHADBLOW AMELANCIER 6'- 7' FT. 1 B&B. MULTI -STEM l� SERVICEBERRY CANADENSIS AR RED ACER 3.0"-3.5" CAL. 1 B&B MAPLE RUBRUM AC` SUGAR ACER 3. 0"-5.5" CAL. 1 B&B J MAPLE SACCHARUM SWEET CLETHRA 24"-30" HT. 5 CG C/fr l`1 PEPPERBUSH ALNIFOL/A CC` RED OSIER CORNUS 30"-36" HT. 6 CG J DOGWOOD SERICEA BLUE FLAG IRIS 12"-18" HT. 84 Ca 24" O.C. R IRIS VERSICOLOR / COMMON ILEX 3'-4' HT. 7 B8'B V WNTERBERRY VERT/CILLATA COMMON JUN/PERUS 24 "-30" HT. 24 CG Jn l� JUNIPER COMMUN/S MDSCARLET RED MONARDA 12 "-18" HT 96 Ca 24" 0. C. BEE BALM D/DYMA MC' OSTRICH MATTEUCC/A 12"-18" HT. 96 CO. 24" O.C. J FERN STRYTH/OP7ER/S P F YELLOW P07E'N77LLA 18"-24" HT. 12 CG PO TEN TILLA FRUTICOSA PG WHI E PICEA 6'- 7' H T 5 B&B SPRUCE GLAUCA RR RUGOSA ROSA 30"-36" HT. 15 CG ROSE RUGOSA HIGHBUSH VACCINIUM 24"-30" HT. 4 CG VC BLUEBERRY CORYMBOSUM VD ARROWWOOD VIBURNUM 3'-4' HT. 6 B&B VIBURNUM DEN TA TUM H 0 I LO RUBBER GARDEN HOSE 12 GA. GALVANIZED WIRE TREE SHALL BEAR SAME RELATION TO FINISHED GRADE AS IT BORE TO PREVIOUS EXISTING GRADE 2" LAYER OF BARK MULCH POST � CUT AND REMOVE BURLAP FROM TOP j OF BALL SAUCER SHAPED UP FROM FINISHED GRADE 3'-0" lciim .r.. ......................rr..5..rrrr low [= TWICE DIA. OF ROOT TOPSOIL MIXTURE UNDISTURBED GRADE OR EARTH BERM MIXTURE NOTE: DETAIL ALSO APPLIES TO SHRUB INSTALLATION 3" MIN. (EXCLUDE STAKING PROCEDURES) CONIFEROUS TREE NOT TO SCALE 12" MIN. 18" 1"2 rrr..r ..... r.u.0 L1:7DIA. OF ROOT BALL TREE WRAPPING FASTENED NEAR TOP AND BOTTOM RUBBER GARDEN HOSE 12 GA. GALVANIZED WIRE CEDAR POST TREE SHALL BEAR SAME RELATION TO FINISH GRADE AS IT BORE TO PREVIOUS EXISTING GRADE 2" LAYER OF BARK MULCH DECIDUOUS TREE NUTOSMAX PLANTS LISTED IN THE PLANTING SCHEDULE CAN BE SUBSTITUTED FOR SIMILAR SPECIES OF THE SAME SIZE WITH THE APPROVAL OF THE OWNER/DEVELOPER AND/OR PROJECT LANDSCAPE ARCHITECT. SHOULD A SUBS77TU77ON BE OFFERED, THE DESIGN PROFESSIONAL SHALL BE NOTIFIED TO CONFIRM THAT THE SUBSTITUTED SPECIES ARE NOT REGULATED OR PROHIBITED SPECIES AS IDENTIFIED BY THE NYDEC PART 575 INVASIVE SPECIES REGULATIONS. ALL LAWN AREAS OF THE SITE SHALL RECEIVE A MINIMUM OF 4" OF TOPSOIL. ALL LANDSCAPE BEDS SHALL RECEIVE A MINIMUM OF 12" OF TOPSOIL. TOP SOIL SHALL HAVE; 2X -20X ORGANIC MATTER PH OF 6- Z 6X MAXIMUM PARTICLE SIZE 1.5" LAWN SEED MIX: SEED LAWN AREAS WITH GRASS SEED CONTAINING A MINIMUM 20X KENTUCKY BLUE GRASS, 20X FESCUE AND A MAXIMUM OF 20X ANNUAL RYE GRASS. SEED SHALL BE APPLIED AT A RATE OF 7-10 LBS PER 1,000 SF PLANTING BED PREPARATION NOTE: ALL PAVEMENT, AND GRAVEL BASE SHALL BE REMOVED FROM PROPOSED PLANTING BEDS AREAS. COMPACTED SUB BASE MATERIALS SHALL BE DECOMPACTED FOR A DEPTH OF 12". PLANTING BEDS SHALL BE FREE OF ROOTS TILLED TO A DEPTH 12". INCORPORATE 2" OF COMPOST INTO SOIL AND TOP DRESS WITH 3" OF HARDWOOD MULCH. GRAPHIC SCALE SAUCER SHAPED UP FROM FINISHED GRADE CUT AND REMOVED BURLAP FROM TOP j OF BALL TOPSOIL MIXTURE UNDISTURBED GRADE OR COMPACTED FILL PLANTING NOTES: 1. PLANTING CONTRACTOR SHALL VERIFY FINAL SELECTION OF PLANT MATERIALS WITH THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 2. ALL AREAS OF SITE WHICH ARE DISTURBED AND NOT LANDSCAPED, PAVED, SHALL BE TOPSOILED, SEEDED, AND MULCHED . (MULCH - STRAW, HYDROSEED MIX, OR BIODEGRADABLE NETTING.) MIXTURES TO BE APPLIED SHALL BE DETERMINED BY OWNER'S REPRESENTATIVES. TOPSOIL TO BE 4" MINIMUM. 3. EXISTING VEGETATION SHALL REMAIN UNDISTURBED WITHIN ALL AREAS OF SITE WHICH DO NOT REQUIRE GRADING. 4. ALL PLANTING BEDS TO RECEIVE 3" MINIMUM BARK MULCH WITH FILTER FABRIC WEED CONTROL OR EQUAL. 5. THIS PLAN IS FOR PLANTING PURPOSES ONLY. REFER TO SITE PLAN FOR DETAILED GRADING AND UTILITY INFORMATION. 6. GUARANTEE: A. FOR A PERIOD OF TWELVE MONTHS FROM THE DATE THAT THE WORK UNDER CONTRACT IS CERTIFIED AS COMPLETE, THE CONTRACTOR SHALL: B. REPLACEMENTS MADE WITHIN SIX MONTHS AFTER BEGINNING OF THE "GUARANTEE PERIOD" SHALL NOT EXTEND THE "GUARANTEE PERIOD" OF THESE PARTICULAR PLANTS; THOSE REPLACEMENTS MADE SIX MONTHS OR MORE AFTER THE BEGINNING OF THE "GUARANTEE PERIOD" SHALL BE MAINTAINED AND GUARANTEED FOR A PERIOD OF SIX MONTHS FROM THE TIME OF REPLACEMENT. APPLICABLE STANDARDS: "AMERICAN STANDARD FOR NURSERY STOCK" BY THE AMERICAN ASSOCIATION OF NURSERYMEN AND "STANDARDIZED PLANT NAMES" BY THE AMERICAN JOINT COMMITTEE ON HORTICULTURAL NOMENCLATURE, ARE A PART OF THIS SPECIFICATION. ALL PLANTS SHALL BE NURSERY GROWN, NOT GATHERED IN THE FIELD. 20 15 10 5 0 20 40 80 (IN FEET) INCH = 20 FT. 3 3 { I 3f .....,....,,, to E N f Fc f ' Z N i 0 i N LO Ui N Q O :) zQ o� ��//�� vJ ca G W X J Lu w V< 2 a Z� LLI z < } Lu� Z Dz W�U }�" U) J 01 QWH Z O cn< Q00 � aLL z ZWZ >- � LLJ QzQ� \ m 0 (D Q ��3 DRAWN BY EHK CHECK BY GV EDP PROJECT NUMBER XXX 7NE ALTERATION OF THESE DOCUMENTS IN ANY WAY. UNLESS DONE UNDER THE DIRECT SUP£RWSION OF A COMPARABLE PROFESSIONAL, (1.E) ENOWEER FDR AN ENGINEER, LANDSCAPE ARONIIECT FOR A LANDSCAPE ARC 17ECT OR SURVEYOR FOR A SURVEYOR. IS A WOLARON OF DIE NEW YORK STATE EDUCATION LAW AND/OR RECLILA71ONS AND IS A CLASS A* 49SO&WNVOR. REVISION DATE BY ADD WETLAND INFORMATION 5-23-22 GV 1 I f e, SCALE: ill 20' SHEET TITLE: PLANTING PLAN SHEET: 6 of 8 f v v v m 0 (U CU (U 0 0 3 rn 3 ti w 3 I z J n_ I m i w w w x ti i tn c C a a, a v A i LO 3 a i Ln w w 3 00 0 ID 0 EL r Q 3 ]C r as i r w 0 z w w z w 3 3. 4. MOUNTABLE BERM (OPTIONAU 50'-0" MIN. Lake CONSTRUCTION SPECIFICATIONS George STONE SIZE — USE 2' CRUSHED STONE, OR RECLAIMED OR RECYCLED CONCRETE EQUIVALENT. LENGTH — AS EFFECTIVE BUT NOT LESS THAN 50 FEET. THICKNESS — NOT LESS THAN SIX(6) INCHES. WIDTH — TWELVE (12) FOOT MINIMUM, BUT NOT LESS THAN THE FULL WIDTH AT POINTS WHERE INGRESS OR EGRESS OCCURS. TWENTY—FOUR (24) FOOT IF SINGLE ENTRANCE TO SITE. FILTER CLOTH — WILL BE PLACED OVER ENTIRE AREA PRIOR TO PLACING OF STONE. SURFACE WATER — ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES SHALL BE PIPED ACROSS THE ENTRANCE. IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. WASHING — WHEN NECESSARY, WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTRANCE ONTO PUBLIC RIGHT—OF—WAY. WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN AREA STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN APPROVED SEDIMENT TRAP OR SEDIMENT BASIN. ALL SEDIMENT SHALL BE PREVENTED FROM ENTERING ANY STORM DRAIN, DITCH OR WATERCOURSE THROUGH USE OF SAND BAGS, GRAVEL BOARDS OR OTHER APPROVED METHODS. MAINTENANCE — THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHTS —OF —WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DRIPPED, WASHED OR TRACKED ONTO PUBLIC RIGHTS —OF —WAY MUST BE REMOVED IMMEDIATELY. PERIODIC INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN. STABILIZED CONSTRUCTION ENTRANCE NOT TO SCALE v /\ /\ 10 MIL PLASTIC LINING a O Q O Q Q r LATH AND FLAGGING ON THREE SIDES CONSTRUCTION SPECIFICATIONS CONCRETE WASHOUT FACILITY SHALL BE LOCATED A MINIMUM OF FIFTY 1. FEET (501 FROM SENSITIVE AREAS. THE BASIN DIMENSIONS DEPICTED ABOVE ARE REQUIRED MINIMUMS. 2• CONCRETE WASHOUT FACILITY SHALL BE CONSTRUCTED AND 3. MAINTAINED IN SUFFICIENT QUANTITY AND SIZE TO CONTAIN ALL LIQUID AND CONCRETE WASTE ENERATED BY WASHOUT OPERATIONS. (APPROXIMATELY 60 GALLONS OF WASTE AND WATER PER TRUCK). 4• PLASTIC LINING MATERIAL SHALL BE A MINIMUM 10 MIN POLYETHYLENE SHEETING AND SHOULD BE FREE OF HOLES, TEARS, OR OTHER DEFECTS 5• THAT COMPROMISE THE IMPERMEABILITY OF THE MATERIAL. WASHOUT FACILITY MUST BE CLEANED, OR NEW FACILITIES MUST BE CONSTRUCTED AND READY FOR USE ONCE THE WASHOUT IS 75% FULL. LATH AND FLAGGING ON THREE SIDES Pi(swelmulln" MAINTENANCE AND CLEANING DO NOT DISCHARGE LIQUID OR SLURRY TO WATERWAYS, STORM DRAINS OR DIRECTLY ONTO GROUND DO NOT USE SANITARY SEWER WITHOUT LOCAL APPROVAL. PLACE A SECURE NON COLLAPSING, NON -WATER COLLECTING COVER OVER THE FACILITY PRIOR TO PREDICTED WET WEATHER TO PREVENT ACCUMULATION AND OVERFLOW. REMOVE AND DISPOSE OF HARDEN CONCRETE AND RETURN THE STRUCTURE TO A FUNCTIONAL STATE. INSPECT THE WASHOUT FACILITY FOR SIGNS OF WEAKENING OR DAMAGE AND REPAIR AS NESSESARY(RELINE THE STRUCTURE WITH NEW POLY SHEETING AFTER EACH CLEANING). CONCRETE WASHOUT FACILITY NOT TO SCALE (TEMPORARY BELOW GRADE) 4G51-i" ALONG ThE 5110RE 91t to Shore 10'± to Shore 20 SILT FENCE SPACING REQUIREMENTS SLOPE STEEPNESS SLOPE LENGTH/FENCE LENGTH (FT.) STANDARD REINFORCED SUPER <2X <50:1 300 / 1500 N / A N / A 2-10X 50:1 TO 10:1 125 / 1000 250 / 2000 300 / 2500 10-20X 10:1 TO 5:1 100 / 750 150 / 1000 200 / 1000 20-33X 5:1 TO 3:1 60 / 500 80 / 750 100 / 1000 33-50X 3:1 TO 2:1 40 / 250 70 / 350 100 / 500 >5OX >2:1 20 / 125 30 / 175 50 / 250 WETLAND AREA - 1,01A* SO. FT. LANDS N/F OF O'KEEFE SILT FENCE GENERAL NOTES: 1. SILT FENCE SHALL BE PLACED A MINIMUM OF 5 FT. FROM TOE OF SLOPE, 10 Fr. PREFERRED, TO PROVIDE ADEQUATE AREA FOR SEDIMENT STORAGE AND FACILITATE MAINTENANCE OF SEDIMENT CONTAINMENT AREA 2. POSTS MAY BE 1.25'x1.25" (MINIMUM) HARDWOOD, TYPICALLY. FOR WIRE MESH BACK USE 2'x2" NOM. HARDWOOD, OR STEEL 'T" OR 'U' POSTS (11b per If). SILT FENCE SHALL BE WOVEN GEOTEXTILE FABRIC(GEOTEX 2130 OR EQUAL). 3. SILT FENCE ASSEMBLIES MAY HAVE 4 FT. OR 6 Fr. POST SPACING, AND MAY OR MAY NOT HAVE MESH REINFORCEMENT. SENSITIVE AREAS TO BE PROTECTED MAY NEED TO BE REINFORCED BY USING HEAVY WIRE FENCING FOR ADDED SUPPORT TO PREVENT COLLAPSE. 4. THE BOTTOM EDGE OF SILT FENCE SHALL BE BURIED A MINIMUM OF 6' BELOW GROUND. THE'FENCE SHALL BE INSTALLED WITH THE POSTS ON THE DOWNSTREAM SIDE OF THE FABRIC. 5. MAXIMUM ALLOWABLE SLOPE LENGTHS CONTRIBUTING RUNOFF TO A SILT FENCE PLACED ON A SLOPE ARE: SLOPE MAXIMUM STEEPNESS LENGTH (f 2:1 25 3:1 50 4:1 75 5:1 OR FLATTER 100 6. MAXIMUM DRAINAGE AREA FOR OVERLAND FLOW TO A SILT FENCE SHALL NOT EXCEED Y4 ACRE PER 100 FEET OF FENCE, WITH MAXIMUM PONDING DEPTH OF 1.5 FEET BEHIND THE FENCE; AND EROSION WOULD OCCUR IN THE FORM OF SHEET EROSION; AND THERE IS NO CONCENTRATION OF WATER FLOWING TO THE BARRIER. 7. MEASURES SHALL BE INSPECTED EVERY SEVEN (7) CALENDAR DAYS, AFTER EACH RAINFALL OF .5' OR MORE WITHIN A 12 HOUR PERIOD, OR DAILY DURING PROLONGED RAINFALL. MEASURES SHALL BE CLEANED AND REPAIRED AS REQUIRED. 8. SEDIMENT SHALL BE REMOVED WHEN ACCUMULATION REACHES ONE—HALF OF THE MEASURE HEIGHT. SEDIMENT SHALL BE DISPOSED OF AS UNSUITABLE MATERIAL SILT FENCE 5' MIN (10' PREFERRED) --I rn \-HARDWOO[ POST UNDISTURBED SEDIMENT GROUND SLOPE ' ONTAINMENT AREA x a 1 ILT FENCE INSTALLATION NOTES: 1. GEOTEXTILE FABRIC AND WOVEN WIREMESH TO BE FASTENED SECURELY TO FENCE POSTS WITH WIRE TIES OR STAPLES. 2. FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES SPACES EVERY 24' AT TOP AND MID SECTION. 3. WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SWILL BE OVERLAPPED BY SIX INCHES, FOLDED AND STAPLED. 4. MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL REMOVED WHEN 'BULGES" DEVELOP IN THE SILT FENCE. NOT TO SCALE WOVEN WIRE MESH REINFORCEMENT (IF NECESSARY) MIN. 14 GAUGE WITH MAX. 6" OPENING PLAN AI _ 1.25" x 1.25" (2" x 2" NOM. FOR WIRE MESH BACK)* HARDWOOD POST * OR STEEL "T" OR "U" SECTION POSTS (1 lb/If MIN.) - WOVEN GEOTEXTILE FABRIC GEOEX 2130 (OR EQUAL) - SILT FENCE ASSEMBLY (SEE INSTALLATION NOES) SEDIMENT CONTAINMENT ARVA jj�l 5' MIN (10' PREFER ED) n TOE OF SLOPE RETAIN EXISTING VEGETATION, IF POSSIBLE EXCAVATE TRENCH, BURY SILT FENCE FABRIC AND BACKFILL/COMPACT EXCAVATED EARTH SECTION AIL UNDISTURBED o �t GROUND M N 1 f- ` QUEENSBURY EROSION CONTROL NOTES: r* \ 1) TEMPORARY EROSION CONTROL SHALL BE PROVIDED FOR ALL DISTURBED AREAS IN ACCORDANCE WITH THE NEW YORK STATE STANDARDS AND SPECIFICATIONS FOR EROSION AND SEDIMENT CONTROL. THE TEMPORARY . ' 0' / c+G EROSION CONTROL MEASURES SHALL BE MAINTAINED CONTINUOUSLY UNTIL PERMANENT CONTROL MEASURES ='' • L \� ARE IN SERVICE.. 1 Q 2) STAGING OF CONSTRUCTION TO FACILITATE EROSION CONTROL SHALL BE REQUIRED. ONLY THOSE AREAS T ; \ WHERE CONSTRUCTION IS ACTIVELY OCCURRING SHALL REMAIN OPEN AND UNVEGETATED. ALL AREAS THAT ARE \ M NOT WITHIN AN ACTIVE CONSTRUCTION AREA SHALL BE MULCHED AND STABILIZED OR SHALL BE MULCHED AND REVEGETATED. AN "ACTIVE CONSTRUCTION AREA" IS DEFINED AS ONE ON WHICH SUBSTANTIAL CONSTRUCTION ACTIVITY HAS OCCURRED WITHIN THE PAST SEVEN CALENDAR DAYS. TEMPORARY OR PERMANENT EROSION CONTROL MEASURES SHALL BE IMPLEMENTED WITHIN 10 DAYS FOLLOWING THE LAST / SUBSTANTIAL CONSTRUCTION ACTIVITY. 3) COMPLIANCE WITH THE FOLLOWING RESTRICTIONS SHALL BE REQUIRED: (A) NO VEGETATION SHALL BE FELLED INTO ANY LAKE, POND, RIVER, STREAM OR INTERMITTENT STREAM, AND, IF INADVERTENTLY FELLED INTO ONE OF THESE WATER BODIES, SHALL BE REMOVED IMMEDIATELY FROM THE WATER BODY. (B) FOR LAND WITH SLOPES GREATER THAN 15% OR WITHIN 500 FEET OF THE MEAN HIGH WATER MARK OF ANY LAKE, POND, RIVER, STREAM OR WETLAND, NO LAND AREA, INCLUDING AREAS STOCKPILED WITH L, _•;.j r� i -, EARTHEN MATERIALS, WHICH HAS BEEN CLEARED MAY BE MADE OR LEFT DEVOID OF GROWING VEGETATION *,+ t ityP''' FOR MORE THAN 24 HOURS WITHOUT A PROTECTIVE COVERING SECURELY PLACED OVER THE ENTIRE AREA "Yr1 t� i AND/OR EROSION CONTROL MEASURES PROPERLY INSTALLED. SrABLIZIED T j CI ENTRANCE AS PER (C) ANY WHOLLYECLEAREDOF NORF ROM WHICH THE NATURAL EMOVED BY DEVELOPMENT ACTIVITIES ATIVE COVER BE REVEGETA EDBEEN R WITHINLLY 10 DAYS FROM THE SUBSTANTIAL COMPLETION OF SUCH CLEARING AND CONSTRUCTION. ACCEPTABLE REVEGETATION SHALL CONSIST OF THE FOLLOWING: (C)1. RESEEDING WITH AN ANNUAL OR PERENNIAL COVER CROP ACCOMPANIED BY PLACEMENT OF STRAW MULCH OR ITS EQUIVALENT OF SUFFICIENT COVERAGE, BUT NOT LESS THAN 50% OF THE TOTAL Wit{ DISTURBED AREA, TO CONTROL EROSION UNTIL SUCH TIME AS THE COVER CROP IS ESTABLISHED OVER A 90% OF THE SEEDED AREA. (C)2. REPLANTING WITH NATIVE WOODY AND HERBACEOUS VEGETATION ACCOMPANIED BY PLACEMENT OF STRAW MULCH OR ITS EQUIVALENT OF SUFFICIENT COVERAGE TO CONTROL EROSION UNTIL THE PLANTINGS ARE ESTABLISHED AND ARE CAPABLE OF CONTROLLING EROSION. (.00 Bench Mark (C)3. ANY OTHER RECOGNIZED METHOD WHICH HAS BEEN REVIEWED AND APPROVED BY THE MUNICIPALITY AS SATISFYING THE INTENT OF THIS REQUIREMENT. ° RR Splke In (D) ANY AREA OF REVEGETATION MUST EXHIBIT SURVIVAL OF A MINIMUM OF 75% OF THE COVER CROP UP NG 3 THROUGHOUT THE YEAR IMMEDIATELY FOLLOWING REVEGETATION. REVEGETATION MUST BE REPEATED IN Elev. = 328. 4' SUCCESSIVE YEARS UNTIL THE MINIMUM SEVENTY -FIVE -PERCENT SURVIVAL FOR ONE YEAR IS ACHIEVED. (, (E) GROUND -CLEARING OR GRADING ACTIVITIES WHICH OCCUR DURING THE PERIOD OCTOBER 15 TO APRIL 15, DURING WHICH GERMINATION OF VEGETATION TYPICALLY WILL NOT TAKE PLACE, SHALL BE REQUIRED TO INCORPORATE EXTRA MEASURES DURING REVEGETATION IN ORDER TO REDUCE EROSION AND MAINTAIN r WATER QUALITY. THESE EXTRA MEASURES INCLUDE, BUT ARE NOT LIMITED TO, THE USE OF SCREEN MESH, O I NETTING, EXTRA MULCH AND SILTATION FENCES. �® .,` EROSION CONTROL A ND GRADING NOTES: 1) MINIMAL EROSION CONTROL DEVICES ARE ILLUSTRATED ON SITE PLAN IN A SCHEMATIC MANNER BASED ON NY 1 STATE GUIDELINES FOR EROSION AND SEDIMENT CONTROL. IT WILL BE NECESSARY TO ADJUST THE ACTUAL LOCATION AND QUANTITY OF EROSION CONTROL DEVICES DEPENDING UPON FIELD CONDITIONS. THE 1 CONTRACTOR SHALL BE RESPONSIBLE FOR IMPLEMENTING THESE MEASURES AS REQUIRED TO PROTECT THE SITE. �I 2) SLOPES SHALL TYPICALLY BE GRADED AT A MAXIMUM OF 3:1 (3 HORIZ. 1 VERT.) WITHIN ALL CUT OR FILL P AREAS, UNLESS OTHERWISE DESIGNATED ON PLANS. 3) SEED SHALL BE A COMMERCIALLY AVAILABLE MIXTURE OF PERENNIAL RYE AND UTILITY GRADE FESCUE. / PERCENTAGE OF PERENNIAL RYE SHALL NOT EXCEED 50%. 4) SEEDED AREAS SHALL BE FULLY COVERED WITH A LEAN STRAW OR MULCH MATERIAL. IF ORDERED BY THE ENGINEER OR MUNICIPALITY, A BIODEGRADABLE NETTING (E.G., EXCELSIOR BLANKET, COIR GEOTEXTILE) SHALL T., BE ANCHORED OVER SEEDED AREAS WHICH DEMONSTRATE "RILLING" OR OTHER EROSION PROCESSES. 5) TOPSOIL AND SEED SHALL BE REAPPLIED TO ANY AREAS WHICH FAIL TO ESTABLISH AS A RESULT OF INITIAL .' APPLICATION. 5) SILT FENCE BARRIERS SHALL BE PLACED WITHIN ALL AREAS OF EXPOSED SLOPES TO CONTROL SOIL EROSION DURING AND AFTER CONSTRUCTION. 7) ALL STORM OUTFALLS SHALL RECEIVE RIP RAP IMMEDIATELY UPON INSTALLATION (AS PER PLAN). B) EROSION CONTROL (ERO-MAT) OR APPROVED EQUAL, SHALL BE INSTALLED ON ALL 2:1 SLOPES: AN ORGANIC FIBER PROTECTIVE MAT, HALF INCH LAYER OF CHOPPED STRAW, KNITTED INTO A RUGGED MAT WITH A THIN NETTING OF PHOTODEGRADABLE POLYPROPYLENE. SECURE MAT TO SLOPE WITH 6" STEEL U-SHAPED STABLES, 2 STAPLES PER SQUARE YARD, OR AS PER MANUFACTERER'S INSTRUCTIONS. 9) STREAM REACHES ON -SITE AND DOWNSTREAM OF CONSTRUCTION SHALL NOT HAVE SUBSTANTIAL VISIBLE CONTRAST RELATIVE TO COLOR, TASTE, ODOR, TURBIDITY AND SEDIMENT DEPOSITION FROM THE REACHES UPSTREAM OF THE CONSTRUCTION ACTIVITY. Lands N/F of 10) VEHICULAR ACCESS POINTS SHALL BE MONITORED AND INSPECTED AT THE SAME FREQUENCY AS EROSION Pamela Golde CONTROL FEATURES TO INSURE THAT DEPOSITS OF SAND, SILT OR OTHER MATERIAL IS NOT BEING DEPOSITED ON PUBLIC ROADWAYS. IN THE EVENT ANY SIGNIFICANT DEPOSITS OCCUR THEY SHALL BE CLEANED UP B:1306 P218 IMMEDIATELY. 226. 15-5-15 GRAPHIC SCALE 20 15 10 5 0 20 40 80 (IN FEET) 1 INCH = 20 FT. 0-V uv Z� 04 r Is- N N Io N LO T_L N Q O Z 0 � U) L W Q Q wW u ^Q L.L z 0 Lu Z < L Cl) W 01 Lu � W m Z W�Q co Q U J W D � � Y W Z Q = Q QUO V ♦ a LL Z ?WZ QO Z(Y- 5 : O O Q � I- �: BY EHK IDRAWN CHECK BY GV EDP PROJECT NUMBER xxx THE ALTERATION OF THESE DOC M 04TS IN ANY WAY, LMESS DONE UNDER THE DIRECT SUPERWMON OF A CONWARABLE PROFESSIONAL, (I.E.) ENGNEER FOR AN ENpNEER, LANDSCAPE ARCH/7ECT FOR A LANDSCAPE ARCMTECT OR SURVEYOR FOR A SURFEM% IS A WOLA77O✓ OF THE NEW YORK STATE EDUC477ON LAW AND1174 REWULADONS AND IS A CLASS A" MISDEMEANOR. REVISION DATE BY ADD WETLAND INFORMATION 5-23-22 GV I ? j SCALE: 1"=20' SHEET TITLE: EROSION AND SEDIMENT CONTROL PLAN SHEET: 7 of 8 f v L9 CD v C3 0 (U Cu 0 (U Co CD 3 HOLDING TANK ALARM SYSTEM: TANK ALERT/ ALARM PANEL WITH ALS-800 SERIES LEVEL SENSOR SPECIFICATIONS: ALARMS AVAILABLE FOR HIGH OR LOW LIQUID LEVEL WARNING WATERPROOF, UL LISTED CABLE SPLICE KIT INCLUDED. VOLTAGE: PRIMARY 120V 60 Hz WITH 6 FT. LINE CORD. SECONDARY 12V 60 Hz. WATTS: 6.5 WATT ALARM CONDITION. ENCLOSURE: 6 in. x 4 in. x 2.5 in. (15.24cm x 10.16cm x 6.35c m) NEMA 1 METAL ENCLOSURE ELECTRICAL KNOCKOUTS FOR DIRECT WIRE OPTIONS ARE STANDARD ON THE ENCLOSURE. ALARM SWITCH CONNECTION TERMINAL: 1 AMP, 24 VAC. ALARM HORN: 87 DECIBELS AT 10 FT. ALARM FLOAT: S.J. ELECTRO SYSTEMS, INC. ALS-800 SERIES MULTI LEVEL SWITCH (LEVEL SENSOR) BUILT TO ORDER 1 /2" NPT STEM STAINLESS STEEL FLOATS (2) PART NUMBER A14569 J-BOX, TO FIT 1 /2" NPT MOUNTING STEM OPTIONS: AUXILIARY DRY CONTACTS FOR REMOTE ALARM HOOK-UP. ALARM PLACEMENT: ONE ALARM PER HOLDING TANK. ALARMS TO BE LOCATED WITHIN BUILDING INTERIOR PER ARCHITECT. NOTES 1. CONTRACTOR TO VERIFY LINE VOLTAGE AT SITE. 2. ALL ELECTRICAL WORK TO BE DONE IN FULL COMPLIANCE WITH THE CURRENT EDITION OF THE NATIONAL ELECTRICAL CODE. 3. THE CONTRACTOR IS RESPONSIBLE FOR FOLLOWING ALL APPLICABLE ELECTRIC AND PLUMBING CODES AT ALL TIMES DURING CONSTRUCTION. 4. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, GRADES, PIPE INVERTS AND ELEVATIONS AND REVIEW WITH ENGINEER PRIOR TO CONSTRUCTION. 5. CONTRACTOR TO COMPLY WITH ALL OSHA AND OTHER STATE AND LOCAL SAFETY REQUIREMENTS DURING CONSTRUCTION. HOLDING TANK NOTES: 1. INSTALLATION OF HOLDING TANKS INVOLVE ABANDONING AND PLUGGING OF EXISTING FLOOR DRAIN CONNECTIONS TO OUTSIDE DRAINAGE PIPING, ETC. AND THE FLOOR DRAINS TO HOLDING TANKS. REFER TO ARCHITECT'S PLANS FOR INFORMATION. 2. CONTRACTOR SHALL CONSULT WITH ARCHITECT AND ENVIRONMENTAL ENGINEER - PRIOR TO TANK INSTALLATION - IF FIELD CONDITIONS DIFFER FROM INFORMATION ON PLANS. ESTABLISHING HOLDING TANK ELEVATIONS: 1. TANK ELEVATIONS TO BE ESTABLISHED IN FIELD. 2. CONTRACTOR TO VERIFY FLOOR DRAIN OUTLET PIPE ELEVATION AND CALCULATE HOLDING TANK INLET INVERT BASED ON NECESSARY LENGTH OF RUN OF NEW DISCHARGE PIPING AT A MINIMUM SLOPE OF 2%. 3. HOLDING TANK INLET INVERT MUST HAVE THE SAME RELATIONSHIP TO THE TANKS INSIDE HEIGHT AS THAT SHOWN WITHIN THE DETAILS OF THIS SHEET. STORMWATER MANAGEMENT ELEVATIONS SMA#5 AREA SMA#8 A-1 (FT) 322.90 324.50 A-2 (FT) 6" „ 9 A-3 (FT) 323.40 325.25 DEPRESSION TO BE PLANTED OR SEEDED WITH APPROPRIATE GROUNDCOVER VEGETATION, BY OWNER - A-3 PONDING DEPTH I_ VARIES �lIIIT_:�A-2 BOTTOM OF GRASSED DEPRESSION III Il MAINTAIN 2' MIN. SHALL REMAIN UNCOMPACTED IN - - VERTICAL SEPARATION ORDER TO PROMOTE INFILTRATION. TO GROUNDWATER OR IMPERVIOUS LAYER. WINTER INFILTRATION AREA (FOR GRASSED WASHED UNIFORM STONE DEPRESSION #2 ONLY) 4 FT BELOW BOTTOM OR BELOW FROST, WHICHEVER 4" PERFORATED PVC IS GREATER SDR-35 UNDERDRAIN (ONLY FOR SMA#8) (GRASSED DEPRESSION #1) (SEE DETAIL) �i SHALLOW GRASSED DEPRESSION NOT TO SCALE #2 CLEAN CRUSHED OR ROUND STONE UJ in WRAP BOTTOM 4" OF STONE WITH NON -WOVEN _ GEOTEXTILE SUCH AS MIRAFI 160N OR EQUAL KEEP BOTTOM OF DRIP EDGE LEVEL AT 324.08' CENTER OF STONE TRENCH TO BE SLIGHTLY DEPRESSED UNCOMPACTED EXISTING EARTH DRIP EDGE NOT TO SCALE 2' WINTER INFILTRATION AREA WASHED UNIFORM STONE 4 FT BELOW BOTTOM OR BELOW MOST, WHICHEVER OVERFLOW WEIR (SEE PLAN & DETAIL) •Y •- -•-•• - • • • • • - - jsna�d, rsl z'd, �sl10 INLET PIPE HOLDINC NOT TO SCALE *TO BE MACHINED FOR BOLTING, 2 ® 180', STAINLESS STEEL. IMPORTANT: CORE FOR 35" ATTACHING WITH Y2"x3" LONG HEX HEAD STAINLESS STEEL ANCHOR BOLTS DRILLED INTO CONCRETE WALL. TANK WITH ALARM LEVEL DIAGRAM TANK MUST CONFORM TO NYS DEPT. OF CONSERVATION REGULATION FOR THIS USE. INTERIOR & SEAMS TO BE SEALED WATERTIGHT WITH OIL AND CHEMICAL RESISTANT MATERIALS, USING E-PDXY INDUSTRIES INC. SYSTEM. 10 6" I I 6" i' �On CONCRETE: 4000 PSI REINFORCEMENT: ASTM A615 - GRADE 60 ENTRAINED AIR: 5.0% - 9.0% MEETS ASTM C890 1 HOLDING TANK CONCRETE PLUGS TO BE REMOVED PER INSTALLATION OF GRADE RINGS AND LOCKING COVERS: HEAVY DUTY LOCKING MANHOLE FRAME AND COVER ON INLET AND OUTLET #1009* WITH FLOW SEAL COVERS BY CAMPBELL OR APPROVED EQUAL NOT TO SCALE V TIR+gAL MANTEL AIM SCHEDIU: ACRNTY faNtlui ENSURE TWAT PAVER AREA IS CLEAN OF MONTHLY DEBRIS ENSURE THAT AREA DEWATERS BETWEEN MONTHLY AND AFTER STORMS STORMS EHSULE THAT THE AREA IS CLEAN OF MONTHLY SEDIMENTS MOW UPLAND AND ADJACENT AREAS, AND S® AS NEEDED BARE ARES VACUUM SWEEP FRECUENTLY 70 KEEP SURFACE TYPICALLY 3 TO 4 TIMES A YEAR FREE OF SEDIMENTS INSPECT THE SURFACE FOR DETERIORATION OR ANNUAL SPALLING CONTRACTOR TO COORDINATE WITH OWNER ON PAVER BLOCK SELECTION 2'-0" I.D. CONC. GRADE RINGS, HT. AS REQUIRED 24" TAPERED HOLE & PLUG (TYP.) / / (n / otTj / Q z U K) 0_ J Q I I I I I I I I SHALLOW GRASSED PLANTER ELEVATIONS GRASS PLANTER #1 GRASS PLANTER #2 GRASS PLANTER #3 GRASS PLANTER #4 GRASS PLANTER #7 GRASS PLANTER #8 GRASS PLANTER #9 A-1 (FT) 324.25 324.25 324.95 325.00 324.25 324.95 325.00 A-2 (FT) 324.60 324.00 324.50 324.00 324.60 324.50 324.50 A-3 (FT) 325.00 325.00 325.70 325.75 325.00 325.70 325.75 A-4 (FT) 324.75 324.75 325.45 325.50 324.75 325.45 325.50 I I I I I I I TYPICAL DOWNSPOUT I I I AS PER ARCHITECT I I I I TYPICAL DOWNSPOUT I OUTLET INTO RAIN GARDEN I WITH STONE APRON I I I I I WHERE REQUIRED I I I I BASE ELEV="A-1" I I MULCH WITH LEAF I I COMPOST OR SHREDDED I I I I WOOD, AVOID WOOD CHIPS I ----- I ���������� INFILTRATION TO GROUND WATER I I I I IMPERMEABLE MEMBRANE L- (POLY OR PVC WATERPROOF r LINER) ON INTERIOR OF WALL AS PER ARCHITECT I L- - - - - - J s1 SHALLOW GRASSED P NOT TO SCALE TOWN OF OUEENSBURY-TOWN CODE CHAPTER 136-11 HOLDING TA SELECTED NATIVE PLANTS (SEE LAKE GEORGE NATIVE PLANTS FOR RAIN GARDENS) A. HOLDING TANKS ARE PROHIBITED UNLESS A VARIANCE IS GRANTED FOR A HOLDING TANK BY THE LOCAL BOARD OF HEALTH PURSUANT TO THE VARIANCE PROVISIONS AT §§136-18 TO 136-20 OF THIS CHAPTER.[AMENDED 5-5-1997 BY L.L. NO. 4-19971 B. IN THE EVENT THE LOCAL BOARD OF HEALTH GRANTS A VARIANCE AUTHORIZING USE OF A HOLDING TANK, THE DESIGN AND INSTALLATION OF THE HOLDING TANK AND ALARM SYSTEM SHALL COMPLY WITH THE FOLLOWING SPECIFICATIONS: [AMENDED 5-5-1997 BY L.L. NO. 4-1997] (1) THE HOLDING TANK SHALL BE A WATERTIGHT PRECAST CONCRETE SEPTIC TANK, WITHOUT OUTLETS, WITH A WATERTIGHT SEALANT MATERIAL FOR JOINTS BELOW THE MAXIMUM WATER LEVEL. THE TANK SHALL ALSO BE EQUIPPED WITH A TWO-PHASE ALARM SYSTEM. REFER TO FIGURES 2 AND 3 FOR THE DETAILS AND SPECIFICATIONS REQUIRED. EDITOR'S NOTE FIGURES 2 AND 3 ARE INCLUDED AT THE END OF THIS CHAPTER. (2) THE HOLDING TANK CAPACITY MUST BE EQUAL TO AT LEAST TWICE THE VOLUME OF WASTE GENERATED BETWEEN ANTICIPATED REMOVAL DATES. THE FOLLOWING TABLE GIVES THE MINIMUM SIZE OF HOLDING TANK REQUIRED AND IS BASED ON SEVEN DAYS BETWEEN ANTICIPATED REMOVAL DATES: REQUIRED MINIMUM HOLDING TANK CAPACITIES NUMBER OF BEDROOMS HOLDING TANK CAPACITY REQUIRED (GALLONS) 1 2,000 2 3,000 3 3,500 4 4,000 5 4,500 (1) THE HOLDING TANK MAY BE SUBJECT TO SEVERE FLOTATION FORCES IN AREAS OF HIGH GROUNDWATER. THUS, HIGH GROUNDWATER DETERMINATION, AS PROVIDED FOR IN APPENDIX F. EDITOR'S NOTE: APPENDIX F IS INCLUDED AT THE END OF THIS CHAPTER. IS REQUIRED WITH EACH APPLICATION SUBMITTAL. WHERE HIGH GROUNDWATER CONDITIONS EXIST, CALCULATIONS BY A REGISTERED ENGINEER ADDRESSING TANK FLOATATION AND MITIGATING MEASURES ARE REQUIRED. (4) HOLDING TANKS SHALL BE LOCATED ABOVE THE ONE -HUNDRED -YEAR FLOOD LEVEL. (5) HORIZONTAL SEPARATION DISTANCES FROM WASTEWATER SOURCES, AS PROVIDED FOR IN APPENDIX A, TABLE I, MUST BE MET. EDITOR'S NOTE: APPENDIX A. TABLE I, IS INCLUDED AT THE END OF THIS CHAPTER. THE SEPARATION DISTANCE REQUIRED FOR HOLDING TANKS SHALL BE THE SAME AS REQUIRED FOR SEPTIC TANKS. (6) HOLDING TANKS TO BE LOCATED UNDER DRIVEWAYS, ROADS, PARKING AREAS OR AREAS SUBJECT TO HEAVY LOADING SHALL BE DESIGNED TO WITHSTAND H-20 HIGHWAY LOADS. CERTIFICATION OF LOAD CAPACITY SHALL BE SUPPLIED BY THE TANK MANUFACTURER. (7) THE HOLDING TANK SHALL BE ACCESSIBLE FOR A PUMPING VEHICLE. EVIDENCE OF AGREEMENT WITH A LICENSED PROFESSIONAL HAULER FOR PUMP OUT AND DISPOSAL IS NECESSARY PRIOR TO APPROVAL OF INSTALLATION. TANK TO BE SET ON (8) THE STALLE OLING TANK SHALL BE REMOVED OR FILLED WITH AN INERT MATERIAL IF ABANDONED OR WIHEN PUBLIC SEWERS ARE D. 6" CLEAN SAND OR PEA GRAVEL (TYP.) INLET KNOCKOUTS PROVIDED FOR 6" PIPE ON THREE SIDES. OUTLET OPENING TO ACCOMMODATE 6" PIPE IF TANK COMES WITH OUTLET OPENING AND EXTRA INLET OPENINGS, SUCH OPENINGS MUST BE THOROUGHLY MORTARED CLOSED AND THOROUGHLY SEALED. • POROUS PAVERS AND ASSOCIATED SUBBASE SHOULD BE INSTALLED TOWARD THE END ON THE CONSTRUCTION PERIOD. UPSTEAM CONSTRUCTION SHOULD BE COMPLETED AND STABILIZED PRIOR TO CONNECTION TO POROUS PAVERS. • POROUS PAVER AREAS SHOULD BE CLEARLY MARRED PRIOR TO CONSTRUCTION TO AVOID ANY SOIL DISTURBANCE AND COMPACTION DURING CONSTRUCTION. • SUBSURFACE AREA SHOULD BE EWAVATED TO PROPER DEPTH. EXISTING SUBGRADE SHALL NOT BE COMPACTED OR SUBJECTED TO EXCESSIVE CONSTRUCTION EOUIPMENT• PRIOR TO PLACEMENT OF GEOTDfT1LE AND STONE BED. IF THE AREA HAS BEEN COMPACTED DUE TO DISTURBANCE AND CONSTRICTION EQUIPMENT LOADING DURING EARLIER STAGES OF CONSTRUCTION THE SUBSURFACE SHALL BE DECOMPACTED AND RESTORED I Y TILLING THE SOIL TO A DEPTH OF 12 INCHES BELOW THE BOTTOM OF THE STONE BED WITH A CAT -MOUNTED RIPPER, TRACTOR MOUNTED OW, OR TILLE2 • PLACE GEOTEXTILE AND STONE BED IMMEDIATELY UPON APPROVAL OF SUBGRADE PREPARATION. • FABRIC SHALL EXTEND AND BE SECURED AT LEAST 4 FEET OUTSIDE OF BED. THIS EDGE STRIP SHALL REMAIN IN PLACE UNTIL ALL BARE SOILS CONTIGUOUS TO THE BEDS ARE STABILIZED AND VEGETATED. CONCRETE PAVER BY TECHO BLOCK "PURE• OR EDGE RESTRAINT JOINT FILLWASHED EQUAL ON HOUSE AREA, OPEN CELL PAVER IN REQUIRED STORE XN- CABIACCONRDANCE INSTALL AND SPACE IN WITH MANUFACRIRESS SPEOFIC11TTON BEDDING LAYER: JV WASHED . -: a•: STONE (2" THICK) NON WOVEN GEOTEXTILE FABRIC FOUNDATION: ® le0 31V CRUSHED STONE (4- MAN) , ' WRAP STONE RESERVOIR WITH MIN. 3' SEPARATION TO BEDROCK OR GROUNDWATER p IO �X' N �® !! I o N pp 7 17 WOVEN GEOTEXTILE FABRIC SUCH AS AMOCO 2008 OR EQUAL RESERVOIR: 2-3- CRUSHED STONE (6- MIN) UNCOMPACTED SUBGRADE INFILTRATION RATE OF SOIL NEEDS TO BE DETERMINED PERMEABLE BLOCK PAVER SECTION NOT TO SCALE LOCKING ASESP�HAL71 � FORMILL MI L PNER) ER SHUTOFF 6" PONDING DEPTH TYPICAL RAIN GARDEN WALL AS PER ARCHITECT • RECOMMENDED SOIL MEDIA MIX TYPICAL FOR GRASSED PLANTERS: 85% SAND (LESS THAN 5% CLAY CONTENT) 10% SOIL FINES 5% ORGANIC MATTER MIX SHALL BE FREE OF STONE, ROOTS WOODY DEBRIS AND ANIMAL WASTE, WITH A SOIL P INDEX t LESS THAN 30. (PER CENTER FOR WATERSHED PROTECTION) SEE SITE PLAN FOR DIMENSIONS OF INDIVIDUAL GRASSED PLANTERS TOP OF WALL ELEV="A-3" TYPICAL RAIN GARDEN WEIR AS PER ARCHITECT WEIR ELEV="A-4" IMPERMEABLE MEMBRANE (POLY OR PVC WATERPROOF LINER) ON INTERIOR OF WALL AS PER ARCHITECT FILL SOIL PER NOTES WINTER INFILTRATION AREA WASHED UNIFORM STONE 4 FT BELOW BOTTOM OR BELOW FROST, WHICHEVER IS GREATER FILTER FABRIC TYPICAL FINISH GRADE ELEV="A-2" CENT TO BUILDIN (9) THE ALARM SYSTEM SEQUENCE OF OPERATIONS IS AS FOLLOWS: WHEN THE LEVEL OF THE HOLDING TANK REACHES 50% OF THE USABLE LEVEL IN THE TANK, THE YELLOW LIGHT WALL INDICATE "TANK HIGH LEVEL." WHEN THE LEVEL OF THE HOLDING TANK REACHES 100% OF THE USABLE LEVEL IN THE TANK, THE BUZZER WILL SOUND, THE RED LIGHT WILL FLASH TO SHUTOFF SO LENOID INDICATE "TANK D 0 LEVEL" AND THE SOLEN D VALVE IN THE MAIN WATER LINE WILL ENERGIZE AND CLO SE TO PREVENT ANY MORE WATER FROM ENTERING THE RESIDENCE. THE PUSHBUTTON WILL BE USED TO SILENCE THE BUZZER. THE SYSTEM WILL RESET AFTER THE HOLDING TANK IS PUMPED DOWN TO BELOW THE ACTUATION LEVEL OF THE LEVEL SWITCHES. (10) FLOAT SWITCHES SHALL BE DIRECT ACTING, NORMALLY OPEN, SUSPENDED, WITH BUILT-IN WEIGHT WHICH ACTUATES WHEN THE LONGITUDINAL AXIS OF THE FLOAT IS HORIZONTAL AND DEACTUATES WHEN THE LIQUID LEVEL FALLS ONE INCH BELOW THE ACTUATION LEVEL. THE FLOAT SWITCH SHALL OPERATE AT 120 VOLTS ALTERNATING CURRENT WITH A PILOT DUTY OF 4.5 AMPERES MINIMUM. THE CONTACT SHALL BE NORMALLY OPEN, I.E., IT SHALL CLOSE WHEN THE FLOAT RISES ABOVE THE ACTUATION LEVEL. THE FLOAT SHALL BE CHEMICAL -RESISTANT POLYPROPYLENE CASING WITH A FIRMLY BONDED ELECTRICAL CABLE PROTRUDING. ONE END OF THE CABLE SHALL BE PERMANENTLY CONNECTED TO THE ENCLOSED MERCURY SWITCH, AND THE ENTIRE ASSEMBLY ENCAPSULATED TO FORM A COMPLETELY WATERTIGHT AND IMPACT -RESISTANT UNIT, GOULD TYPE A2-3 OR EQUIVALENT. (11) THE FLOAT SWITCH WIRING SHALL BE TERMINATED IN A NEMA 4X JUNCTION BOX MOUNTED INSIDE THE HOLDING TANK. ALL WIRING FROM THE FLOAT SWATCH JUNCTION BOX TO THE LEVEL ALARM SYSTEM PANEL SHALL BE INSTALLED UNDERGROUND IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE AND ALL STATE AND LOCAL CODES. WIRING SHALL BE 3#12AWG, TYPE THW OR THWN, CONDUCTORS IN A ONE HALF -INCH PVC CONDUIT. ONE LEVEL SWITCH SHALL BE ACTUATED WHEN THE TANK IS AT 50% OF THE USABLE CAPACITY TO INDICATE A HIGH LEVEL. THE SECOND LEVEL SWITCH SHALL BE ACTUATED WHEN THE TANK IS AT 100% OF THE USABLE CAPACITY TO INDICATE A SHUT OFF LEVEL. (12) THE CONTROL RELAYS SHALL BE GENERAL PURPOSE, 120 VOLTS ALTERNATING CURRENT, WITH CONTACTS RATED FOR FIVE AMPERES CONTINUOUS. THE NUMBER AND TYPE OF CONTACTS SHALL BE AS SHOWN, SQUARE "D" 8501, TYPE RS-14, OR EQUIVALENT. A RELAY SOCKET TO MATCH THE CONTROL RELAY FURNISHED SHALL BE PROVIDED. (13) THE ALARM LIGHTS SHALL BE 120 VOLTS ALTERNATING CURRENT PILOT LIGHTS WITH A DOMED PLASTIC LENS. THE "TANK HIGH LEVEL" LIGHT LENS SHALL BE YELLOW, SQUARE "D" KP1Y9 TYPE K OR EQUIVALENT. THE "TANK SHUTOFF LEVEL" LIGHT SHALL BE SUPPLIED WITH A FLASHER AND A RED LENS, SQUARE "D" KPF1R9 TYPE K OR EQUIVALENT. (14) THE BUZZER SHALL BE 120 VOLTS ALTERNATING CURRENT, HEAVY DUTY, ADJUSTABLE VOLUME EDWARDS ADAPTABUZZER, TYPE 340A-N5 OR EQUIVALENT. (15) A NORMALLY OPEN, 120 VOLTS ALTERNATING CURRENT, NONILLUMINATED PUSHBUTTON SHALL BE PROVIDED. THE PUSHBUTTON SHALL HAVE A FULL GUARD. SQUARE "D" KR1UH5 TYPE K OR EQUIVALENT. (16) THE RELAYS AND RELAY SOCKETS SHALL BE MOUNTED IN A GENERAL PURPOSE NEMA 1 ENCLOSURE. THE ALARM LIGHTS, BUZZER AND THE BUZZER SILENCE PUSHBUTTON SHALL BE MOUNTED ON THE FRONT OF THE ENCLOSURE. ALL NECESSARY MATERIALS SHALL BE PROVIDED, I.E., TERMINAL BLOCKS, CONNECTORS, ETC., TO MOUNT AND CONNECT ALL DEVICES. THIS ENCLOSURE SHALL BE PROVIDED WITH A NAMEPLATE WITH THE FOLLOWING DESCRIPTION "HOLDING TANK LEVEL ALARM SYSTEM." PLASTIC LAMINATED NAMEPLATES, WHITE THROUGH TO BLACK CORE, SHALL BE PROVIDED OVER EACH DEVICE. THE NAMEPLATE DESCRIPTION SHALL BE AS INDICATED ON THE SCHEMATIC. ALL WIRING IN THE HOLDING TANK LEVEL ALARM SYSTEM CONTROL PANEL SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. A COPY OF THE SCHEMATIC AND SEQUENCE OF OPERATION SHALL REMAIN WITH CONTROL PANEL. THE ENCLOSURE SHALL BE MOUNTED IN A SUITABLE LOCATION IN THE RESIDENCE. (17) THE SOLENOID VALVE SHALL BE A NORMALLY OPEN (ENERGIZE -TO -CLOSE) VALVE, 120 VOLTS ALTERNATING CURRENT AND SHALL BE INSTALLED IN THE RESIDENCE INCOMING MAIN WATER LINE. THE SIZE OF THE VALVE ORIFICE SHALL CORRESPOND WITH THE PIPE DIAMETER OF THE WATERLINE. WIRING TO THE SOLENOID SHALL BE SIZED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE. (18) ALL HOLDING TANKS MUST BE INSTALLED BELOW FINISHED GRADE OF THE SITE WITHIN A FIFTY -FOOT RADIUS OF THE INSTALLATION. THIS SECTION IS INTENDED TO PREVENT THE OCCURRENCE OF MOUNDING IN THE AREA OF THE TANK.[AMENDED 7-6-1998 BY L.L. NO. 4-1998] C. OTHER APPLICABLE PROVISIONS CONTAINED IN THIS PART 1 SHALL APPLY IN ADDITION TO THE ABOVE. TANK NOTES: 1. THE PROPOSED TANK CONFIGURATION SHALL CONSIST OF 2 - 2000 GALLON PRECAST CONCRETE TANKS. 2. THE TANKS AS SPECIFIED SHALL BE WATERTIGHT. THE TANK LOCATION COULD BE SUBJECT TO GROUNDWATER CONDITIONS. EXTERIOR SEALANT COATING SHALL BE USED, AS NEEDED, TO ASSURE THAT NO INFILTRATION (OR EXFILTRATION WHEN NO SEASONAL GROUNDWATER IS PRESENT) OCCURS. 3. TANKS SUBJECT TO SEASONAL GROUNDWATER CONDITIONS COULD ALSO HAVE THE POTENTIAL FOR 'TANK FLOATATION'. THE CONTRACTOR, UPON CONSULTATION WITH THE ENGINEER, SHALL TAKE MEASURES NECESSARY TO ELIMINATE THE RISK OF FLOATATION OF THE TANKS. I• .0 ALL JOINTS BELO BITUMINOUS LIQUID LEVEL TO BE WATERTIGHT AND INTERIOR COAT 774E SLOPE OF 774E INLET PIPE LEAKAGE TESTED KOP 300M TANK HIGH BETIMEEN 774E RESADEN77AL PRIOR TO BACKFILL ING OR EQUAL t LEVEL FLOAT UNIT AND THE HOLDING TANK TO BE 1/4- PER FT. 6- TO 12" LAYER PEA GRAVEL OR CRUSHED STONE SECTION VIEW BEDDING LAYER m OUTSIDE TANK SIZE MAX LIQUID DEPTH "A• TANK DIMENSIONS-B-X-C- "O• -1- HEIGHT 2000 GAL 3'-9- 7'-0' X 13'-0' 4'-•" 4'-9- W-11- HOLDING TANK LAYOUT NOT TO SCALE • • • - •- 0 • - •1 1. KEY MATTING AT ALL EDGES IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS PLAN VIEW 2' "R =III=III=III=III=III=III=III- - PERFORATED NOT TO SCALE BACKFILL TRENCH WITH SANDY 'ZOIL FREE OF DEBRIS, FOREIGN ATERIAL, BOULDERS ETC. AND I -SITU INFILTRATION RATE ON HE ORDER OF 1 INCH/HOUR. PITCH BOTTOM TO UNDER DRAIN UNDISTURBED SOIL SDR-35 PERFORATED ..,JEER DRAIN INV.=321.50' UNDER DRAIN 10 4 Z� N N N N ' O I N LO t N N Q CI z Q 0 � a. rr^^C vJ G W X LuCW J uG < a Z0 UJ z a a� m 0 uj �w z Q m z W C_) >- cn W J Q W Z LU O Q Q 0 2 a '� ZWW z 0 azof Z m 3: 0� O ��� DRAWN BY EHK CHECK BY GV EDP PROJECT NUMBER XXX THE ALTERATION OF TRH DOCUUMV75 IN ANY WAY, UNLESS DONE UNDER IRE DIRECT SIAPERNSION OF A COMPARABLE PROFES9gVN. (LE.) ENGINEER FOR AN ENGINEER, LANDSCAPE AROYI7ECT FOR A LANDSCAPE ARCHI7ECT OR SURYEYDR FOR A SURL£YOII: IS A HOLA770N OF THE NEW YORK STATE EDUCA710V LAW AND/OR RCGULA77ONS AND IS A CLASS A• MISDEMEANOR. REVISION DATE BY ADD WETLAND INFORMATION 5-23-22 GV } i i i fI SCALE: AS NOTED SHEET TITLE: SITE DETAILS SHEET: 8 of 8