2002-341 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518)761-8256
CERTIFICATE
OF COMPLIANCE
Permit Number: P20020341 Date Issued: Monday,August 09,-2004
This is,to certify that work requested to be done as shown by Permit Number P20020341
has been completed. -
Tax Map Number: 523400-290-017-0001-016-000-0000
Location: 16 MASTERS COMMON SOUTH
Owner: RALPH DE WITT
Applicant: RALPH DE WITT
This structure may be occupied as a:
By Order of Town Board
Deck „ TOWN OF QUEENSBURY
"i
Director of Building&Code Enforcement
' TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building& Codes (518) 761-8256 r
BUILDING PERMIT
Permit Number: P20020341 Application Number: A20020341
Tax Map No: 523400-200-017-0601-016-000-0000
Permission is hereby granted to: RALPH DE WITT
For property located at: 16 MASTERS COMMON SOUTH
in the Town of Queensbury, to construct or place
at,the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of ConstructionValue
Owner Address: RALPH DE WITT Deck 300.00
16 MASTER COMMONS SOUTH Total Value 300.00
QUEENSBURY,NY 12804'0000
Contractor or Builder's Name j Address Electrical Inspection Agency
DANA CROSS
65 COUNTY ROUTE 43
ARGYLE,NY
Plans &Specifications
2002-341
168 SQ FT DECK AS PER PLOT PLAN SPECIFICATIONS
$40.00 PERMIT FEE PAID—THIS PERMIT EXPIRES: Tuesday,.May 13,2003
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer I,
of the Town of Queensbury before the expiration date.)
Dated a e wa p
ue nsb Monday,May 13,2002
SIGNED B - for the Town of Queensbury.
mY
Director of Building&Code Enforcement
TOWN OF QUEENSBURY Fee Paid -)Y 0 0
BUILDING & CODES DEPARTMENT Permit #
APPLICATION FOR: PORCHES-DECKS- o �=s L
DOCKS & BOATHOUSES Est. Cost,
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. PLEASE ANSWER ALL OF THE FOLLOWING:
The undersigned hereby applies for a Building Permit to do the following work which will be
done in accordance with the description, plans and specifications submitted, and such special
conditions as may he indicated on the pernri t. 'TWO Sf7'S OF S"rRUC1*URAL PLANS SIIALL BL•" SUBMf I TE
WITIf T111S APPLICATION.
Owner of Property:
P.Q. Address �)rlgma l �' `�'' Phone # � `lam" �✓ /�
Property Location ; -°} _ ,,E -VN. cz� - ��{ � Tax Map # L-4 L 7—,2-
Subdivision Name (If applicable)
PERSON RESPONSIBLE FOR SUPERVISION OF WORK AS REGARDS TO BUILDING CODES: 1
Name: Address Phone#
BUILDING SPECIFICATIONS:
Type of work to be done: Porch Deck Dock Boathouse (Circle one)
Size of Structure to be built (square footage): �`gSj W
Foundation Material : Width T-h-ickness >
Depth of Footing, below grade:
Size of Posts or Studs: (_/ ` x � f x 4 Long
Size of Floor Joists: 2--f x x / r Span
Decking or_Flooring Material : 6214-t- X .C,;:, F%
Now will Porch or Deck be fastened to 'building? ��'�,
hno'\ e,-Z_<. l
If Roof Will Be Instal ed, Answer Following rI.�Y 0 2 2002
g Questions: ,Size of Posts or Studs: x x LongTOLWiINIOirF QL1_-��Q'LR y
Roof Rafters: x aciarg Span
Roof Trusses (pre-engineered s a•e'ing): Span-
Type of Roof: Sloped Flat Shed 0 h r (Circle one)
Material of Roof:
ZONING INFORMATION:
TWO PLOT PLANS MUST BE PREPARED AND SUBMITTED, drawn reasonably to scale and attached
hereto, show ng ' c car y a i st ncZ1y all [iulTi(1r1gs, whether existing or proposed land
indicate all: set back dimensions from property lines. Show location of water supply and
location and configuration of septic disposal area.
Size of Property: ft. x ft.
Existing building(s): Size ft. x ft.
Size ft. x ft.
Use of Existing building(s):
Proposed structure, distance from property line:
:Front yard ft. Rear yard ft.
Side yards ft. and - ft.
If on corner, setback from sld' e street: ft.
DECLARATION
To the best of my knowledge and belief the statements. contained in this application,
together with the plans and specifications submitted, are a true and complete statement:
of all proposed work to be done on the described premises and that all provisions of the
Building Code, the Zoning Ordinance, and all other laws pertaining t•o the ,proposed work
shall be complied with, whether speciFied or not, and that such work is authorized1by the
owner.
DATE: SfiGNAfURE-
4 w er, Owners Agenc cl' ect Contractor
l REVIEWED BY CODE ENFORCEMENT OFFICER, DATE t`Z�'� SIGNATURE
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No.(518)761-8256 Arrive: 91f amtpm epart: am/pm
Date Inspection request received: _ Inspector's Initials:
NAME: � �?� � PERMIT#:
LOCATION: DATE:
TYPE OF STRUCTURE:
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6"
Roof Complete/Exterior Finish Complete
Guard 30 in.or more @ stairs,decks,patios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in. or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum ''/z"
Gypsum
Grade away from foundation 6 in.with 10€t.
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft.or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: / Battery backup:
Carbon Monoxide Detector
Bathroom Fans, if.no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/1/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, 1 s . ft.-150 s .ft.vents
Building No./Address visible from road
Final Electrical
Site'Plan /Variance re uiredl
Final Survey Plot Plan U
As Built Septic System/Sewer Dept,Inspection Sticker
Flood Plain CertificatiopEjL459uired
Okay to issue C/C Cr C/ ern orar •/Permanent
L:\PamW\Building&Codes\Inspection Forms\Res.Final Insp.form 2.docLast printed 2/12/04
D_
I%Xsidential Final Inspection
Office No. (518) 761-8256 Date Inspection requ t e ive
req S re
u
P
Queensbury Building&Code Enforcement Arrive: D art: Q a
Is
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials
NAME: P
LD P MIT#:
TT
LOCATION: TE:
TYPE OF STRUCTURE:
Comments
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof
Roof Complete
Guard 30 in. or more @ stairs,decks,patios
Guard at stairwell at 34 in.or more
Guard at deck porches 36 in. or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 3
Platform at all exterior doors
or'r
I Interior Handrails stair or more risers
Interior
Grade away from founcFa7tion 6 in. with 10--ft,
Grade
Handrail
Handrail Termination at Newell Post or Wall
r
8 inch
clearance
8 inch clearance to sill plate
Gas Valve shut-off exposed./regulator.18"above grade
Gas Furnace shut-off within 30.ft. or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water eater operating
Low water sbut=oHboiler
Relief Valves installed
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glaziU
:I—
,�Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: _ / Every Bedroom:
Outside every bedroom area:
Inter Connected: / Battery backup:
Bathroom Fans,if no window
Carbon Monoxide detector
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement.1,000 sf
Ejaergena egress below grade
Basement stairs closed rise>4 inches
'/4hour fire door/door closer
.-Garage fireproofing
Duct work Sealed properly
Attic access 30 in.x 24 in,x 30 in.(ht.)In accessible area
a
Crawl§paces 18"x24"access, I sq.ft.-150 sEg.ft.vents
Building No./Address visible'from road
Final Electrical
Site Plan /.Variance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept. Inspection Sticker
Flood Plain Certification, if required
Okayto issue C/C(Cert.Of Compliance)
Okay to issue Temporary C 0(Cert. Of Occupancy)
Okay to issue Permanent C 0(Cert, Of Occupancy)
L:\SueHemingway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003
Residential Final Inspection
Office No. (518)761-8256 Date Inspection re. r ived: 3 fn,416 Y
Queensbury Building&Code Enforcement Arrive: ' k: m
742 Bay Rd., Queensbury,NY 12804 Inspector's Initi s:
NAME: L TWT#:
LOCATION: ATE:
TYPE OF STRUCTURE:
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof
Roof Complete
Guard 30 in. or more @ stairs,decks,patios
Guard at stairwell at 34 in.or more
Guard at deck,porches 36 in.or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
8 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft. or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
-Low water shut-off boiler
Relief Valve(s)installed
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing
Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: Battey backup:
Bathroom Fans,if no window
Carbon Monoxide detector
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
3/4hour fire door/door closer
Garage fireproofing
Duct work Sealed properly
Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, I sq. ft.-150 sq. ft.vents
Building No./Address visible from road
Final Electrical
Site Plan /Variance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept,Inspection Sticker
Flood Plain Certification,if required
Okay to issue C/C(Cert. Of Compliance)
Okay to issue Temporary C/0(Cert. Of Occiipancy)
Okay to issue Permanent C/0(Cert. Of Occupancy)
I.:\SueHeminDvaylBLiilding.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003
RESIDENTIAL FINAL INSPECTION REPORT
Office No.(518)761-8256 Date inspection request received:
Building&Code Enforcement inspection
Dept. of Community Development Arrivew-IGOM Depart
Town of Queensbury Inspector's
742 Bay Road �o �
Queensbury,New ork'12804
NANE ti
LOCATION DATE
TYPE OF STRUCTURE
NIA YES NO COMMENTS
Chimney HeightPT"Vent/Direct Vent Location
Fresh Air Intake
Plumb Vent through roof
Roof Complete
Exterior Finish Complete
Interior/Exterior Railings 30"to 36"
Exterior Handrails,balconies,landing 18 in.or more
Interior Handrails stairs both sides 3 or more risers
Grade 2%away from foundation
8"clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Ve� -T-C:) -V-C�F c5V-)�)EC4
Gas Furnace shut-off within 30 feet or within line of site
OilFurnace shut-off at entrance to furnace area
Furnacefflot Water Heater operating
Relief Valve(s)installed
Headroom,6 ft.6 in.on stairs
Basement stairs,6 ft.4 in.
Handrail exterior stairs both sides more than 3 risers
Interior privacy/trim/doors/main entrance 36"_
Floor Finish
BatbroomT.itchen watertight�__
Interior Handrails Balconies/Landing 18 in.or more
Railing across window in stairwells
Smoke Detectors:
every level
every bedroom
outside every bedroom
inter connected
Bathroom fans
Plumbing fixtures
Foundation insulation
3/4 hour fire door/door closer
Garage fireproofing
Garage penetrations sealed
Furnace in separate room protected(in garage)
Light ventilation per room
Safety glazing 18"or less from floor
Final Electrical
Site Plan/Variance required
Final Survey Plot Plan
As Built Septic System layout required A
Okay to issue C/C(Certif.of Compliance
Okay to issue temp.C/O(Certif of Occupancy)_
Okay to issue permanent C/O(Certif,of Occupancy)__j_